Skip to main content
Erschienen in: Acta Neurochirurgica 5/2016

Open Access 19.03.2016 | Clinical Article - Vascular

Clinical experience with navigated 3D ultrasound angiography (power Doppler) in microsurgical treatment of brain arteriovenous malformations

verfasst von: Geirmund Unsgård, Vidar Rao, Ole Solheim, Frank Lindseth

Erschienen in: Acta Neurochirurgica | Ausgabe 5/2016

Abstract

Introduction

We have previously described a method that has the potential to improve surgery of arteriovenous malformations (AVMs). In the present paper, we present our clinical results.

Materials and methods

Of 78 patients referred for AVMs to our University Hospital from our geographical catchment region from 2005 through 2013, 31 patients were operated on with microsurgical technique. 3D MR angiography (MRA) with neuronavigation was used for planning. Navigated 3D ultrasound angiography (USA) was used to identify and clip feeders in the initial phase of the operation. None of our patients was embolized preoperatively as part of the surgical procedure. The niduses were extirpated based on the 3D USA. After extirpation, controls were done with 3D USA to verify that the AVMs were completely removed. The Spetzler three-tier classification of the patients was: A: 21, B: 6, C: 4.

Results

Sixty-eight feeders were identified on preoperative MRA and DSA and 67 feeders were identified and clipped by guidance of intraoperative 3D USA. Six feeders identified preoperatively were missed by 3D USA, while five preoperatively unknown feeders were found and clipped. The overall average bleeding was 440 ml. There was a significant reduction in average bleeding in the last 15 operations compared to the first 16 (340 vs. 559 ml, p = 0.019). We had no serious morbidity (GOS 3 or less). New deficits due to surgery were two patients with quadrantanopia (one class B and one class C), the latter (C) also acquired epilepsy. One patient (class A) acquired a hardly noticeable paresis in two fingers. One hundred percent angiographic cure was achieved in all patients, as evaluated by postoperative DSA.

Conclusions

Navigated intraoperative 3D USA is a useful tool to identify and clip AVM feeders. Microsurgical extirpation assisted by navigated 3D USA is an effective and safe method for removing AVMs.

Introduction

The reported results from the various interventions for brain AVMs are heterogeneous [13]. In spite of the large number of publications about embolization and Gamma Knife treatment of AVMs in recent years, the most efficient treatment in terms of radiological cure still is microsurgical extirpation. According to a meta-analysis from 2000 to 2011, successful brain AVM obliteration was achieved in 96 % after microsurgery, 38 % after stereotactic radiosurgery, and 13 % after embolization [13]. Gamma Knife therapy is often preferable in deep-seated lesions with difficult locations because the AVM can be occluded with less risk of complications than with microsurgical treatment [3]. Embolization has, because of the low occlusion rate, mostly been used in combination with surgery to reduce the challenge for the surgeon. Many AVMs, especially those with Spetzler three-tier class A (Spetzler/Martin grade I and II), are treated by microsurgery only [10]. AVM surgery is challenging. We have used ultrasound technology to assist in the resection of these difficult lesions with the intention to reduce the harm to the patients. In 2005, we published a paper describing the feasibility of using a navigation system with stereoscopic display of the vessels and 3D ultrasound angiography (USA) to identify and occlude feeding vessels in the initial phase of the operation [12]. In the present paper, we summarize our clinical experience with this technology.

Materials and methods

Patients

Norway has a socialized and regionalized health care system where all patients with neurosurgical diseases in a defined geographical catchment region are referred to the serving university hospital. In the period from 2005 through 2013, 78 patients with AVMs were referred to our neurosurgical department. Before deciding the treatment, patients and their closest family were thoroughly informed about the different treatment modalities. Thirty-three patients with small AVMs in deep-seated locations were referred to Gamma Knife treatment. Thirty-one were treated with a microsurgical operation. Fourteen were not offered treatment because of high risk (S/M grade V), high age, and significant co-morbidity or due to patient preferences.
The incidence of microsurgically operated AVMs in our region, with 700,000 inhabitants, is accordingly around 0.5 per 100,000 per year. The annual incidence rate of diagnosed AVMs is 1.2 per 100,000.
All patients underwent both DSA and MRA as part of the diagnostic work up. Some of the patients with AVMs in eloquent areas also underwent fMRI and/or MR tractography. In all operations, we used navigated 3D USA, as described earlier [12]. The Regional Ethical Committee approved the study, and the patients signed an informed consent form. The operated patients were all untreated except for two. One had at a previous occasion been treated with embolization three times together with Gamma Knife treatment. Another had been treated with Gamma Knife. Both were referred to surgery due to treatment failure. None of the 31 operated patients was embolized preoperatively as part of the surgical procedure. Demographics and the results for the operated patients are shown in Tables 1 and 2. The patients were, before surgery, graded according to the Spetzler/Martin system. In this paper we will use the Spetzler three-tier classification, where S/M grade I and II is combined to a class A, S/M grade III equals class B, and S/M grade IV and V is combined to a class C [10]. The classifications of the patients were: 21 class A (8 S/M grade I and 13 S/M grade II), six class B, and four class C (S/M grade IV). The causes for diagnostic investigations were headache/dizziness/fatigue – 12 cases, ICH – eight cases, epilepsy – six cases, neurological deficits – two cases, no symptoms related to the AVM – three cases. In 16 of the 31 cases the AVM were located in eloquent parts of the brain.
Table 1
Grading, eloquence, and intraoperative events
Spetzler three-tier class (10)
Patients (n)
Sex (male/female)
Age (years)
Feeders visualized preoperative (#)
Feeders clipped before resection (#)
Duration of operation (min)
Perop. bleeding (ml)
Eloquent n (%)
A (I/II)
21
9/12
41.5
43
40
303
379
7 (33)
B (III)
6
4/2
46.3
15
20
355
391
5 (83)
C (IV)
4
2/2
56.8
10
7
443
837
4 (100)
Total
31
15/16
44.4
68
67
331
440
16 (52)
Table 2
Preoperative symptoms and postoperative outcome
Spetzler three-tier class (10)
Patients (n)
Preop. symptoms n (symptoms)
Postop. complications n (complications)
Status 3 days postop. n (symptoms)
Status 3 months postop. n (patients)
A I/II
21
Asymptomatic 3 Headaches/Dizziness 8
Hemianopia 3
ICH 6
Epileptic seizure 4
Hemiparesis 2
Paresthesia 1
None 15
PE 1
Hematoma 2
Pneumonia 3
Epileptic seizure 2
UTI 1
Normal 14
Paresis 3
Aphasia 3
Ataxia 1
Hemianopia 2
Normal 18
Unchanged deficit 2
New deficit 1 (feeling of less control in two fingers)
B III
6
Headaches/Dizziness/Fatigue 4
ICH 1
Epileptic seizure 1 Hemiparesis 1
None 5
UTI 1
Normal 3
Aphasia 2
Hemianopia 1
Normal 4
Unchanged deficit 1
New deficit 1 (lower quadrantanopia)
C IV
4
Headaches/Dizziness/Fatigue 3
ICH 1
Epileptic seizure 1
None 2
Epileptic seizure 2
Paresis 1
Ataxia 1
Hemianopia 2
Normal 2
Unchanged deficit 1
New deficit 1 (lower quadrantanopia and epilepsy)
Total
31
    
ICH intracerebral hematoma, PE pulmonary embolism, UTI urinary tract infection
New deficit includes both neurological deficit and epilepsy

Navigation equipment

The preoperative 3D MRA was imported into the ultrasound-based intraoperative imaging system SonoWand (Sonowand A/S, Trondheim, Norway). Power Doppler-based 3D USA was obtained during the procedure. Until 2009 we used version 1.4 of the SonoWand system as described in a previous paper [12]. After that we have used the SonoWand Invite system. In the Invite version, there is no stereoscopic module available, so in addition we used the research system Custus X, which provided rendering of both 3D MRA and 3D USA. Since 2012 we have used navigated microscope and a targeting function (Fig. 1). The target point is set by a navigator (rotation sensitive pointer) with offset. With the navigated microscope, a plane with the visual line (center of the microscope vision down to focus point) and a plane perpendicular to this plane through the target point appear as navigated cross sections on the navigation monitor (tip view). A dotted line extending the visual line indicates the distance from the focus point of the microscope to the target point.

The procedure

As the first step during surgeries, the 3D MRA were imported into the navigation system and registered to the head of the patient. Based on the 3D MRA, the head was adjusted to facilitate a horizontal position of the craniotomy, which is associated with less brain shift during surgery and is better for obtaining good ultrasound 3D image recordings [11]. The stereoscopic display or the 3D MRA rendering was used for updating the surgeon on the angiographic architecture of the AVM. It was also used for detailed planning of where to occlude the different feeders (Fig. 2). After the craniotomy, a 3D USA volume was recorded by moving the appropriate probe with optical tracking over the area of interest. The image volumes were usually displayed in dual anyplane, the upper plane being a cross section steered either by a rotation-sensitive navigator or a microscope, and the lower plane being a cross section perpendicular to the upper plane along the extension line of the navigator or the centerline of the microscope view. A shift between 3D MRA and 3D USA was observed in most patients (Fig. 3). 3D MRA was used for facilitating interpretation of the 3D USA, but due to the shift/registration inaccuracy of the 3D MRA, the identification and clipping of the feeders were done based on the 3D USA data. As a tool for identification of the feeders, we either used a navigator or the navigated microscope. In cases with navigated microscope, the target point was set with a navigator (with offset) at the planned point for clipping of the feeder (Fig. 4). The upper row is the same cross section as in dual anyplane. After having set the target point, the lower row shows a plane perpendicular to the visual line of the microscope (“tip view”). After clipping of the feeders, a new 3D USA was acquired to look for and eventually clip additional feeders. After resection of the nidus, a final 3D USA was acquired as a resection control.

Results

Identification and clipping of feeders

In the 31 patients, a total of 68 feeders were identified from preoperative DSA and 3D MRA. From 3D USA recordings, 67 feeders were also identified and subsequently clipped but not always the same feeders that had been identified on the preoperative images. A concordance between 3D MRA/DSA and 3D USA was found for 62 feeders (91 %). Six feeders identified in the preoperative MRA/DSA were missed by 3D USA. In one patient, as many as four very thin feeders were visualized in preoperative DSA/MRA that we were unable to identify in the 3D USA images. That patient had, at a previous occasion, been treated with embolization three times together with Gamma Knife treatment. On the other hand, 3D USA identified five feeders that were not seen in MRA/DSA, four of them in the 2nd 3D USA recorded after the initial clipping.

Resection of the AVMs

After clipping of all the identified feeders, a new 3D USA recording showed in some cases large reduction of power Doppler signals in the nidus indicating low flow (Figs. 5 and 6). In those cases, it was very easy to resect the AVMs with very little blood loss. In many cases, there was still considerable flow after clipping, though much reduced as evaluated by the turgor of the AVM nidus and the 3D power Doppler signal in the nidus. This remnant flow was presumably due to small feeding vessels (perforators) that were not identified and clipped in the early phase of the operation.
3D USA was also helpful in defining the borders of the AVM during extirpation. In cases where the power Doppler signal after clipping was reduced to nearly nothing in the nidus, the 3D USA acquired before the clipping of the feeders was used for accurate resection of the nidus (Fig. 6).
The average peroperative bleeding for all cases was 440 ml. For the 10 class B and C cases, the average bleeding was 579 ml. For the first 16 patients, including 2 class B and 3 class C cases, the average bleeding was 559 ml, and in the last 15 cases including 4 class B and one class C, the average bleeding was 340 ml (p = 0.019 by the Mann–Whitney U test). This may indicate some improvement during the development of the technology.
At the end of the resection, a new 3D USA acquisition confirmed that the AVM was completely removed in all the cases (Fig. 6).

Outcome

The outcomes are summarized in Table 2. Postoperatively, four patients had early and transient epileptic seizures that were handled without the need for long-term antiepileptic medication. One patients had pulmonary embolisms, two had a postoperative surgical site hemorrhage, and three had postoperative pulmonary or urinary tract infections. None of the patients were reoperated and all these postoperative adverse events were handled without permanent loss of functions or health.
As for permanent neurological deficits (after 3 months) two patients had acquired a homonym quadrantanopia as a consequence of the operation. One was a class B and the other was a class C patient. The latter also acquired epilepsy 2 months after the operation. One patient with a class A AVM in the precentral gyrus by the hand knob had no evident paresis after 3 months, but still he had a feeling of reduced fine motor control in two fingers. One patient with a class A AVM that had been treated with Gamma Knife radiosurgery 4 years earlier had no deficit 3 months after the operation, but 10 months after the operation she had an epileptic seizure. One patient with a large ICH at presentation had a hemiparesis that was temporarily worsened after the operation. At control 3 months later he was back to his preoperative status.
All patients underwent DSAs 3 months after the operation. No residual AVM and normalization of the vasculature were confirmed in all cases.

Discussion

The technique of operating AVMs with early clipping of feeders based on neuronavigation was reported many years ago [8]. However, the identification of the feeders based on navigation in preoperative MR angiograms can be difficult because of the registration error and the brain shift. We have in a previous article demonstrated the concept of using navigated 3D US angiography to identify both superficial and deep feeders [12]. The present consecutive case series is a follow-up of our clinical results.
In a medium-sized neurosurgical unit, AVM operations are uncommon, with limited possibilities for neurosurgeons to obtain experience with these challenging patients. Therefore, every development that can make this operation easier should be acknowledged.
One technique that has been used for some time in AVM surgery is indocyanine green angiography. We have no experience with this modality but according to a recent paper from one of the most merited groups in AVM surgery, it does not improve the clinical outcome and it seems to have shortcomings in deep AVMs [14].
Our concept is somewhat different to the usual way of operating AVMs and can be summed up as follows: Navigated 3D MRA is registered to the patient’s head and rendered for planning of the craniotomy and where to clip the different feeding vessels. DSA is used in the preoperative work-up to confirm the 3D MRA findings of feeders and draining veins. The 3D USA can be recorded both before and after opening of the dura. The identification of the feeding vessels should be done based on the latter image volume, because there is often a small shift between navigated 3D USA acquired before and after opening of the dura. Before even touching the nidus, feeding vessels are identified, localized, and clipped. The identification of feeders based on 3D USA is reliable. Only six of 68 feeders identified on preoperative DSA/MRA were missed. Four of these feeders were in one patient that earlier had been treated three times with embolization and also have had Gamma Knife treatment. The feeders in this patient were tiny and hard to recognize also in the MRA volume. The strength of the method is that even very deep-seated feeders can be reached and identified with precise transcortical dissection by navigated 3D USA before starting the dissection of the nidus. Navigation towards the feeders is facilitated by navigated microscope. By moving the microscope to a position where the navigated centerline of the microscope hit the target point of the feeder, a precise dissection through the brain and identification of the feeder can be done by using the crosshairs of the microscope.
When all the feeders have been clipped, a second 3D USA volume is acquired to recognize residual flow in the nidus and possibly unidentified feeders. This second 3D USA after clipping and before starting the resection was done routinely only in the last 15 cases. In four cases, additional feeding vessels not identified in the preoperative work-up were discovered and clipped. Presumably, the vessels were discovered because the major part of the flow was eliminated from the nidus.
In most cases, the turgor and the power Doppler activity in the nidus was strongly reduced after clipping, but in a few cases, there was still cumbersome bleeding due to small feeders that could not be properly identified neither from the preoperative MR angiographies, DSAs, nor in the intraoperative 3D US angiograms. A navigated resection was done guided by the 3D USA volume of the nidus acquired before start of the clipping of feeders [6].
Resection control with 3D USA after removal of the nidus was done in all cases to confirm complete removal of the AVM. No intraoperative or postoperative DSA was done until the DSA control 3 months after the surgery.
One limitation of the technology is the lack of information about the direction of blood flow in the power Doppler angiography. A method has been developed for mapping angle-corrected velocities and flow direction to the 3D geometry of the vessels [4, 5], but it has not been available in the operation theatre for the cases presented in this study. Thus, the identification of feeders vs. veins has been based on the angioarchitecture and the comparing of intraoperative 3D USA to the preoperative 3D MRA. This way of identifying feeders vs. veins was reliable in this material, because we never misinterpreted the nature of the vessels. But it claims some concern from the surgeon. Our method for mapping flow direction to the 3D geometry of the 3D USA is now available in the operation theatre, and will be used for future AVM operations.
The planning and clipping procedure added some extra time to the fist phase of the operation. The average operation time is 320 min for all operations and 274 min for the last 15 operations, which by some will be considered long. On the other hand, operation time was not an issue in this series, which also involved some other research tasks not reviewed in this paper.
We did not use preoperative embolization for any of our patients. One of the patients had been unsuccessfully embolized years earlier at another hospital. Our assumption is that what can be gained with preoperative embolization in terms of making the extirpation of the nidus easier can be achieved by navigated intraoperative clipping of the feeding vessels without the extra risks associated with embolization. Moreover, incompletely embolized vessels may be a problem during subsequent surgery [3]. There may be cases where large, deep-seated feeding vessels are better handled with preoperative embolization, but in our cohort there were no such cases. There would certainly be a possibility to combine the two techniques since it is unlikely that the embolization of a deep feeder would interfere much with the image quality of the power Doppler angiography.
In only 25 % of our patients the AVMs were diagnosed because of hemorrhage. The way of handling unruptured AVMs is controversial. Studies have indicated that patients with unruptured AVMs can be handled with conservative, medical management instead of interventional therapy [1, 7]. These results have been criticized[2], and a recent paper from a group with a large experience in AVM surgery concludes that surgery should be regarded as the first-line or gold-standard therapy for the majority of low-grade (class A) AVMs [9]. An unknown factor is the quality of life for a patient harboring an AVM with a bleeding potential. Thus, surgical resection seems to be an optimal handling also of patients with unruptured AVMs, as long as we are able to keep the complication rate at a low level.
In a recent paper, serious procedural complications in AVM surgery were defined as GOS equal or less than 3 after 30 days [3]. Using that definition, none of our patients experienced serious procedural complications.
Considering neurological deficits, the only acquired deficit in the class A or low-grade AVM patients was one patient with an AVM in the precentral gyrus that had a feeling of reduced fine motor control of two fingers evaluated 3 months after the operation. It had no influence on his daily activity and can hardly be registered as morbidity. In a recent publication, a summation of the results of 12 published series showed a morbidity for low-grade AVMs of 2.2 % [9]. The numbers of class B (6) and C (4) patients are too small for a reasonable evaluation. One class B patient acquired quadrantanopia and one class C patient acquired both a quadrantanopia and epilepsy. The quadrantanopia seemed to be of little concern to these patients, but unfortunately we do not have quality-of-life data.
The effectiveness of the treatment is excellent since postoperative DSAs confirmed no residual AVM in any of the patients. The 100 % radiological cure is probably facilitated by active use of 3D US angiography during the operations.

Conclusions

Navigated intraoperative 3D USA is a helpful tool to identify, localize, and clip AVM feeders. Good clinical and excellent radiological results can be obtained by microsurgical extirpation assisted by navigated intraoperative 3D US angiography.

Compliance with ethical standards

Funding

National Competence Services for Ultrasound and Image-guided Therapy funded by the Norwegian Health Department.

Conflict of interest

All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest, or non-financial interest in the subject matter or materials discussed in this manuscript.
The Regional Ethical Committee approved the study, and the patients have signed an informed consent
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Neurologie & Psychiatrie

Kombi-Abonnement

Mit e.Med Neurologie & Psychiatrie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Weitere Produktempfehlungen anzeigen
Literatur
1.
Zurück zum Zitat Al-Shahi Salman R, White PM, Counsell CE, du Plessis J, van Beijnum J, Josephson CB, Wilkinson T, Wedderburn CJ, Chandy Z, St George EJ, Sellar RJ, Warlow CP (2014) Outcome after conservative management or intervention for unruptured brain arteriovenous malformations. JAMA 311:1661–1669CrossRefPubMed Al-Shahi Salman R, White PM, Counsell CE, du Plessis J, van Beijnum J, Josephson CB, Wilkinson T, Wedderburn CJ, Chandy Z, St George EJ, Sellar RJ, Warlow CP (2014) Outcome after conservative management or intervention for unruptured brain arteriovenous malformations. JAMA 311:1661–1669CrossRefPubMed
2.
Zurück zum Zitat Bambakidis NC, Cockroft K, Connolly ES, Amin-Hanjani S, Morcos J, Meyers PM, Alexander MJ, Friedlander RM (2013) Preliminary results of the ARUBA study. Neurosurgery 73:E379–E381CrossRefPubMed Bambakidis NC, Cockroft K, Connolly ES, Amin-Hanjani S, Morcos J, Meyers PM, Alexander MJ, Friedlander RM (2013) Preliminary results of the ARUBA study. Neurosurgery 73:E379–E381CrossRefPubMed
3.
Zurück zum Zitat Bradac O, Charvat F, Benes V (2013) Treatment for brain arteriovenous malformation in the 1998–2011 period and review of the literature. Acta Neurochir 155:199–209CrossRefPubMed Bradac O, Charvat F, Benes V (2013) Treatment for brain arteriovenous malformation in the 1998–2011 period and review of the literature. Acta Neurochir 155:199–209CrossRefPubMed
4.
Zurück zum Zitat Iversen DH, Lindseth F, Unsgaard G, Torp H, Lovstakken L (2013) Model-based correction of velocity measurements in navigated 3-D ultrasound imaging during neurosurgical interventions. IEEE Trans Med Imaging 32:1622–1631CrossRefPubMed Iversen DH, Lindseth F, Unsgaard G, Torp H, Lovstakken L (2013) Model-based correction of velocity measurements in navigated 3-D ultrasound imaging during neurosurgical interventions. IEEE Trans Med Imaging 32:1622–1631CrossRefPubMed
5.
Zurück zum Zitat Lindseth F, Lovstakken L, Rygh OM, Tangen GA, Torp H, Unsgaard G (2009) Blood flow imaging: an angle-independent ultrasound modality for intraoperative assessment of flow dynamics in neurovascular surgery. Neurosurgery 65:149–157, discussion 157PubMed Lindseth F, Lovstakken L, Rygh OM, Tangen GA, Torp H, Unsgaard G (2009) Blood flow imaging: an angle-independent ultrasound modality for intraoperative assessment of flow dynamics in neurovascular surgery. Neurosurgery 65:149–157, discussion 157PubMed
6.
Zurück zum Zitat Mathiesen T, Peredo I, Edner G, Kihlstrom L, Svensson M, Ulfarsson E, Andersson T (2007) Neuronavigation for arteriovenous malformation surgery by intraoperative three-dimensional ultrasound angiography. Neurosurgery 60:345–350, discussion 350–341CrossRefPubMed Mathiesen T, Peredo I, Edner G, Kihlstrom L, Svensson M, Ulfarsson E, Andersson T (2007) Neuronavigation for arteriovenous malformation surgery by intraoperative three-dimensional ultrasound angiography. Neurosurgery 60:345–350, discussion 350–341CrossRefPubMed
7.
Zurück zum Zitat Mohr JP, Parides MK, Stapf C, Moquete E, Moy CS, Overbey JR, Al-Shahi Salman R, Vicaut E, Young WL, Houdart E, Cordonnier C, Stefani MA, Hartmann A, von Kummer R, Biondi A, Berkefeld J, Klijn CJ, Harkness K, Libman R, Barreau X, Moskowitz AJ (2014) Medical management with or without interventional therapy for unruptured brain arteriovenous malformations (ARUBA): a multicentre, non-blinded, randomised trial. Lancet 383:614–621CrossRefPubMedPubMedCentral Mohr JP, Parides MK, Stapf C, Moquete E, Moy CS, Overbey JR, Al-Shahi Salman R, Vicaut E, Young WL, Houdart E, Cordonnier C, Stefani MA, Hartmann A, von Kummer R, Biondi A, Berkefeld J, Klijn CJ, Harkness K, Libman R, Barreau X, Moskowitz AJ (2014) Medical management with or without interventional therapy for unruptured brain arteriovenous malformations (ARUBA): a multicentre, non-blinded, randomised trial. Lancet 383:614–621CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Muacevic A, Steiger HJ (1999) Computer-assisted resection of cerebral arteriovenous malformations. Neurosurgery 45:1164–1170, discussion 1170–1161CrossRefPubMed Muacevic A, Steiger HJ (1999) Computer-assisted resection of cerebral arteriovenous malformations. Neurosurgery 45:1164–1170, discussion 1170–1161CrossRefPubMed
9.
Zurück zum Zitat Potts MB, Lau D, Abla AA, Kim H, Young WL, Lawton MT, Project UBAS (2015) Current surgical results with low-grade brain arteriovenous malformations. J Neurosurg 122:912–920CrossRefPubMedPubMedCentral Potts MB, Lau D, Abla AA, Kim H, Young WL, Lawton MT, Project UBAS (2015) Current surgical results with low-grade brain arteriovenous malformations. J Neurosurg 122:912–920CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Spetzler RF, Ponce FA (2011) A 3-tier classification of cerebral arteriovenous malformations. Clinical article. J Neurosurg 114:842–849CrossRefPubMed Spetzler RF, Ponce FA (2011) A 3-tier classification of cerebral arteriovenous malformations. Clinical article. J Neurosurg 114:842–849CrossRefPubMed
11.
Zurück zum Zitat Unsgard G, Solheim O, Lindseth F, Selbekk T (2011) Intra-operative imaging with 3D ultrasound in neurosurgery. Acta Neurochir Suppl 109:181–186CrossRefPubMed Unsgard G, Solheim O, Lindseth F, Selbekk T (2011) Intra-operative imaging with 3D ultrasound in neurosurgery. Acta Neurochir Suppl 109:181–186CrossRefPubMed
12.
Zurück zum Zitat Unsgaard G, Ommedal S, Rygh OM, Lindseth F (2005) Operation of arteriovenous malformations assisted by stereoscopic navigation-controlled display of preoperative magnetic resonance angiography and intraoperative ultrasound angiography. Neurosurgery 56:281–290, discussion 281–290CrossRefPubMed Unsgaard G, Ommedal S, Rygh OM, Lindseth F (2005) Operation of arteriovenous malformations assisted by stereoscopic navigation-controlled display of preoperative magnetic resonance angiography and intraoperative ultrasound angiography. Neurosurgery 56:281–290, discussion 281–290CrossRefPubMed
13.
Zurück zum Zitat van Beijnum J, van der Worp HB, Buis DR, Al-Shahi Salman R, Kappelle LJ, Rinkel GJ, van der Sprenkel JW, Vandertop WP, Algra A, Klijn CJ (2011) Treatment of brain arteriovenous malformations: a systematic review and meta-analysis. JAMA 306:2011–2019CrossRefPubMed van Beijnum J, van der Worp HB, Buis DR, Al-Shahi Salman R, Kappelle LJ, Rinkel GJ, van der Sprenkel JW, Vandertop WP, Algra A, Klijn CJ (2011) Treatment of brain arteriovenous malformations: a systematic review and meta-analysis. JAMA 306:2011–2019CrossRefPubMed
14.
Zurück zum Zitat Zaidi HA, Abla AA, Nakaji P, Chowdhry SA, Albuquerque FC, Spetzler RF (2014) Indocyanine green angiography in the surgical management of cerebral arteriovenous malformations: lessons learned in 130 consecutive cases. Neurosurgery 10(Suppl 2):246–251, discussion 251CrossRefPubMed Zaidi HA, Abla AA, Nakaji P, Chowdhry SA, Albuquerque FC, Spetzler RF (2014) Indocyanine green angiography in the surgical management of cerebral arteriovenous malformations: lessons learned in 130 consecutive cases. Neurosurgery 10(Suppl 2):246–251, discussion 251CrossRefPubMed
Metadaten
Titel
Clinical experience with navigated 3D ultrasound angiography (power Doppler) in microsurgical treatment of brain arteriovenous malformations
verfasst von
Geirmund Unsgård
Vidar Rao
Ole Solheim
Frank Lindseth
Publikationsdatum
19.03.2016
Verlag
Springer Vienna
Erschienen in
Acta Neurochirurgica / Ausgabe 5/2016
Print ISSN: 0001-6268
Elektronische ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-016-2750-3

Weitere Artikel der Ausgabe 5/2016

Acta Neurochirurgica 5/2016 Zur Ausgabe

Clinical Article - Brain Tumors

World Health Organization grade II meningiomas

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.