Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 2/2013

01.02.2013 | Experimental study

Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction

verfasst von: María Prado, Belén Martín-Castilla, Alejandro Espejo-Reina, José Miguel Serrano-Fernández, Ana Pérez-Blanca, Francisco Ezquerro

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 2/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

In anterior cruciate ligament reconstruction with looped soft-tissue grafts, an interference screw is frequently used for tibial fixation. This study compared three alternatives thought to improve the initial mechanical properties of direct bioabsorbable interference screw fixation: suturing the graft to close the loop, adding a supplementary staple, or increasing the oversize of the screw diameter relative to the bone tunnel from 1 to 2 mm.

Methods

Twenty-eight porcine tibiae and porcine flexor digitorum profundus tendons were randomized into four testing groups: a base fixation using 10-mm-diameter screw with open-looped graft, base fixation supplemented by an extracortical staple, base fixation but closing the looped graft by suturing its ends, and base fixation but using an 11-mm screw. Graft and bone tunnel diameters were 9 mm in all specimens. Constructs were subjected to cyclic tensile load and finally pulled to failure to determine their structural properties.

Results

The main mode of failure in all groups was pull-out of tendon strands after slippage past the screw. The sutured graft group displayed significantly lower residual displacement (mean value reduction: 47–67 %) and higher yield load (mean value increase: 38–54 %) than any alternative tested. No other statistical differences were found.

Conclusions

Suturing a soft-tissue graft to form a closed loop enhanced the initial mechanical properties of tibial fixation with a bioabsorbable interference screw in anterior cruciate ligament reconstructions using a porcine model, and thus, this may be an efficient means to help in reducing post-operative laxity and early clinical failure. No mechanical improvement was observed for an open-looped tendon graft by adding an extracortical staple to supplement the screw fixation or by increasing the oversize of the screw to tunnel diameter from 1 to 2 mm.
Literatur
1.
Zurück zum Zitat Adam F, Pape D, Schiel K, Steimer O, Kohn D, Rupp S (2004) Biomechanical properties of patellar and hamstring graft tibial fixate on techniques in anterior cruciate ligament reconstruction: experimental study with roentgen stereometric analysis. Am J Sports Med 32:71–78PubMedCrossRef Adam F, Pape D, Schiel K, Steimer O, Kohn D, Rupp S (2004) Biomechanical properties of patellar and hamstring graft tibial fixate on techniques in anterior cruciate ligament reconstruction: experimental study with roentgen stereometric analysis. Am J Sports Med 32:71–78PubMedCrossRef
2.
Zurück zum Zitat Brand JC Jr, Pienkowski D, Steenlage E, Hamilton D, Johnson DL, Caborn DNM (2000) Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am J Sports Med 28:705–710PubMed Brand JC Jr, Pienkowski D, Steenlage E, Hamilton D, Johnson DL, Caborn DNM (2000) Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am J Sports Med 28:705–710PubMed
3.
Zurück zum Zitat Bravman J, Ishak C, Gelber J, Namkoong S, Jazrawi L, Kummer FJ (2006) The interaction between the whipstitch sutures of multi-strand ACL grafts and interference screw fixation. Bull Hosp Jt Dis 63:156–157PubMed Bravman J, Ishak C, Gelber J, Namkoong S, Jazrawi L, Kummer FJ (2006) The interaction between the whipstitch sutures of multi-strand ACL grafts and interference screw fixation. Bull Hosp Jt Dis 63:156–157PubMed
4.
Zurück zum Zitat Caborn DNM, Nyland J, Selby J, Tetik O (2003) Biomechanical testing of hamstring graft tibial tunnel fixation with bioabsorbable interference screws. Arthroscopy 19:991–996PubMedCrossRef Caborn DNM, Nyland J, Selby J, Tetik O (2003) Biomechanical testing of hamstring graft tibial tunnel fixation with bioabsorbable interference screws. Arthroscopy 19:991–996PubMedCrossRef
5.
Zurück zum Zitat Chang HC, Nyland J, Nawab A, Burden R, Caborn DN (2005) Biomechanical comparison of the bioabsorbable RetroScrew system, BioScrew XtraLok with stress equalization tensioner, and 35-mm Delta Screws for tibialis anterior graft-tibial tunnel fixation in porcine tibiae. Am J Sports Med 33:1057–1064PubMedCrossRef Chang HC, Nyland J, Nawab A, Burden R, Caborn DN (2005) Biomechanical comparison of the bioabsorbable RetroScrew system, BioScrew XtraLok with stress equalization tensioner, and 35-mm Delta Screws for tibialis anterior graft-tibial tunnel fixation in porcine tibiae. Am J Sports Med 33:1057–1064PubMedCrossRef
6.
Zurück zum Zitat Charlick DA, Caborn DN (2000) Alternative soft tissue graft preparation technique for cruciate ligament reconstruction. Arthroscopy 6:E20 Charlick DA, Caborn DN (2000) Alternative soft tissue graft preparation technique for cruciate ligament reconstruction. Arthroscopy 6:E20
7.
Zurück zum Zitat Espejo-Baena A, Ezquerro F, Pérez de la Blanca A, Serrano-Fernández J, Nadal F, Montañez-Heredia E (2006) Comparison of initial mechanical properties of 4 hamstring graft femoral fixation systems using nonpermanent hardware for anterior cruciate ligament reconstruction: an in vitro animal study. Arthroscopy 22:433–440PubMedCrossRef Espejo-Baena A, Ezquerro F, Pérez de la Blanca A, Serrano-Fernández J, Nadal F, Montañez-Heredia E (2006) Comparison of initial mechanical properties of 4 hamstring graft femoral fixation systems using nonpermanent hardware for anterior cruciate ligament reconstruction: an in vitro animal study. Arthroscopy 22:433–440PubMedCrossRef
8.
Zurück zum Zitat Giurea M, Zorilla P, Amis AA, Aichroth P (1999) Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med 27:621–625PubMed Giurea M, Zorilla P, Amis AA, Aichroth P (1999) Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med 27:621–625PubMed
9.
Zurück zum Zitat Halewood C, Hirschmann MT, Newman S, Hleihil J, Chaimski G, Amis AA (2011) The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro. Knee Surg Sports Traumatol Arthrosc 19:559–567PubMedCrossRef Halewood C, Hirschmann MT, Newman S, Hleihil J, Chaimski G, Amis AA (2011) The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro. Knee Surg Sports Traumatol Arthrosc 19:559–567PubMedCrossRef
10.
Zurück zum Zitat Hamner DL, Brown CH Jr, Steiner ME, Hecker AT, Hayes WC (1999) Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg Am 81:549–557PubMed Hamner DL, Brown CH Jr, Steiner ME, Hecker AT, Hayes WC (1999) Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg Am 81:549–557PubMed
11.
Zurück zum Zitat Harvey A, Thomas NP, Amis AA (2005) Fixation of the graft in reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br 87-B:593–603CrossRef Harvey A, Thomas NP, Amis AA (2005) Fixation of the graft in reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br 87-B:593–603CrossRef
12.
Zurück zum Zitat Herrera A, Martínez F, Iglesias D, Cegoñino J, Ibarz E, Gracia L (2010) Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study. BMC Musculoskelet Disord 11:139–146PubMedCrossRef Herrera A, Martínez F, Iglesias D, Cegoñino J, Ibarz E, Gracia L (2010) Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study. BMC Musculoskelet Disord 11:139–146PubMedCrossRef
13.
Zurück zum Zitat Hill PF, Russell VJ, Salmon LJ, Pinczewski LA (2005) The influence of supplementary tibial fixation on laxity measurements after anterior cruciate ligament reconstruction with hamstring tendons in female patients. Am J Sports Med 33:94–101PubMedCrossRef Hill PF, Russell VJ, Salmon LJ, Pinczewski LA (2005) The influence of supplementary tibial fixation on laxity measurements after anterior cruciate ligament reconstruction with hamstring tendons in female patients. Am J Sports Med 33:94–101PubMedCrossRef
14.
Zurück zum Zitat Johnson D (2005) Anterior cruciate reconstruction using hamstring graft fixed with bioscrews and augmented with the endopearl. Tech Orthop 20:264–271CrossRef Johnson D (2005) Anterior cruciate reconstruction using hamstring graft fixed with bioscrews and augmented with the endopearl. Tech Orthop 20:264–271CrossRef
15.
Zurück zum Zitat Kamelger FS, Onder U, Schmoelz W, Tecklenburg K, Arora R, Fink C (2009) Suspensory fixation of grafts in anterior cruciate ligament reconstruction: a biomechanical comparison of 3 implants. Arthroscopy 25:767–776PubMedCrossRef Kamelger FS, Onder U, Schmoelz W, Tecklenburg K, Arora R, Fink C (2009) Suspensory fixation of grafts in anterior cruciate ligament reconstruction: a biomechanical comparison of 3 implants. Arthroscopy 25:767–776PubMedCrossRef
16.
Zurück zum Zitat Kitamura N, Yasuda K, Yamanaka M, Tohyama H (2003) Biomechanical comparisons of three posterior cruciate ligament reconstruction procedures with load-controlled and displacement-controlled cyclic tests. Am J Sports Med 31:907–914PubMed Kitamura N, Yasuda K, Yamanaka M, Tohyama H (2003) Biomechanical comparisons of three posterior cruciate ligament reconstruction procedures with load-controlled and displacement-controlled cyclic tests. Am J Sports Med 31:907–914PubMed
17.
Zurück zum Zitat Kousa P, Järvinen TLN, Vihavainen M, Kannus P, Järvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction: Part II: tibial site. Am J Sports Med 31:182–188PubMed Kousa P, Järvinen TLN, Vihavainen M, Kannus P, Järvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction: Part II: tibial site. Am J Sports Med 31:182–188PubMed
18.
Zurück zum Zitat Krackow KA, Thomas SC, Jones LC (1988) Ligament-tendon fixation: analysis of a new stitch and comparison with standard techniques. Orthopedics 11:909–917PubMed Krackow KA, Thomas SC, Jones LC (1988) Ligament-tendon fixation: analysis of a new stitch and comparison with standard techniques. Orthopedics 11:909–917PubMed
19.
Zurück zum Zitat Kudo T, Tohyama H, Minami A, Yasuda K (2005) The effect of cyclic loading on the biomechanical characteristics of the femur-graft-tibia complex after anterior cruciate ligament reconstruction using Bone Mulch screw/WasherLoc fixation. Clin Biomech 20:414–420CrossRef Kudo T, Tohyama H, Minami A, Yasuda K (2005) The effect of cyclic loading on the biomechanical characteristics of the femur-graft-tibia complex after anterior cruciate ligament reconstruction using Bone Mulch screw/WasherLoc fixation. Clin Biomech 20:414–420CrossRef
20.
Zurück zum Zitat Lahav A, Burks RT (2005) Evaluation of the failed ACL reconstruction. Sports Med Arthrosc Rev 13:8–16CrossRef Lahav A, Burks RT (2005) Evaluation of the failed ACL reconstruction. Sports Med Arthrosc Rev 13:8–16CrossRef
21.
Zurück zum Zitat Lee JJ, Otarodifard K, Jun BJ, McGarry MH, Hatch GF III, Lee TQ (2011) Is supplementary fixation necessary in anterior cruciate ligament reconstructions? Am J Sports Med 39:360PubMedCrossRef Lee JJ, Otarodifard K, Jun BJ, McGarry MH, Hatch GF III, Lee TQ (2011) Is supplementary fixation necessary in anterior cruciate ligament reconstructions? Am J Sports Med 39:360PubMedCrossRef
22.
Zurück zum Zitat Lim CT, Tan K, Chuan AK (2009) Clinical stability and outcome of supplementing tibial fixation with a staple for ACL reconstruction using hamstring tendons. Curr Orthop Pract 20:660–664CrossRef Lim CT, Tan K, Chuan AK (2009) Clinical stability and outcome of supplementing tibial fixation with a staple for ACL reconstruction using hamstring tendons. Curr Orthop Pract 20:660–664CrossRef
23.
Zurück zum Zitat Magen HE, Howell SM, Hull ML (1999) Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27:35–43PubMed Magen HE, Howell SM, Hull ML (1999) Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27:35–43PubMed
24.
Zurück zum Zitat Meuffels DE, Docter PT, van Dongen RA, Kleinrensink G, Verhaar JAN, Reijman M (2010) Stiffer fixation of the tibial double-tunnel anterior cruciate ligament complex versus the single tunnel: a biomechanical study. Arthroscopy 26:S35–S40PubMedCrossRef Meuffels DE, Docter PT, van Dongen RA, Kleinrensink G, Verhaar JAN, Reijman M (2010) Stiffer fixation of the tibial double-tunnel anterior cruciate ligament complex versus the single tunnel: a biomechanical study. Arthroscopy 26:S35–S40PubMedCrossRef
25.
Zurück zum Zitat Micucci CJ, Frank DA, Kompel J, Muffly M, Demeo PJ, Altman GT (2010) The effect of interference screw diameter on fixation of soft-tissue grafts in anterior cruciate ligament reconstruction. Arthroscopy 26:1105–1110PubMedCrossRef Micucci CJ, Frank DA, Kompel J, Muffly M, Demeo PJ, Altman GT (2010) The effect of interference screw diameter on fixation of soft-tissue grafts in anterior cruciate ligament reconstruction. Arthroscopy 26:1105–1110PubMedCrossRef
26.
Zurück zum Zitat Miyata K, Yasuda K, Kondo E, Nakano H, Kimura S, Hara N (2000) Biomechanical comparisons of anterior cruciate ligament: reconstruction procedures with flexor tendon graft. J Orthop Sci 5:585–592PubMedCrossRef Miyata K, Yasuda K, Kondo E, Nakano H, Kimura S, Hara N (2000) Biomechanical comparisons of anterior cruciate ligament: reconstruction procedures with flexor tendon graft. J Orthop Sci 5:585–592PubMedCrossRef
27.
Zurück zum Zitat Monaco E, Labianca L, Speranza A, Agro AM, Camillieri G, D’arrigo C, Ferretti A (2010) Biomechanical evaluation of different anterior cruciate ligament fixation techniques for hamstring graft. J Orthop Sci 15:125–131PubMedCrossRef Monaco E, Labianca L, Speranza A, Agro AM, Camillieri G, D’arrigo C, Ferretti A (2010) Biomechanical evaluation of different anterior cruciate ligament fixation techniques for hamstring graft. J Orthop Sci 15:125–131PubMedCrossRef
28.
Zurück zum Zitat Morris MW, Williams JL, Thake AJ, Lang Y, Brown JN (2004) Optimal screw diameter for interference fixation in a bone tunnel: a porcine model. Knee Surg Sports Traumatol Arthrosc 12:486–489PubMedCrossRef Morris MW, Williams JL, Thake AJ, Lang Y, Brown JN (2004) Optimal screw diameter for interference fixation in a bone tunnel: a porcine model. Knee Surg Sports Traumatol Arthrosc 12:486–489PubMedCrossRef
29.
Zurück zum Zitat Nagarkatti DG, McKeon BP, Donahue BS, Fulkerson JP (2001) Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29:67–71PubMed Nagarkatti DG, McKeon BP, Donahue BS, Fulkerson JP (2001) Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29:67–71PubMed
30.
Zurück zum Zitat Namkoong S, Heywood CS, Bravman JT, Ieyasa K, Kummer FJ, Meislin RJ (2006) The effect of interference screw diameter on soft tissue graft fixation. Bull Hosp Jt Dis 63:153–155PubMed Namkoong S, Heywood CS, Bravman JT, Ieyasa K, Kummer FJ, Meislin RJ (2006) The effect of interference screw diameter on soft tissue graft fixation. Bull Hosp Jt Dis 63:153–155PubMed
31.
Zurück zum Zitat Nurmi JT, Sievänen H, Kannus P, Järvinen M, Järvinen TLN (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32:765–771PubMedCrossRef Nurmi JT, Sievänen H, Kannus P, Järvinen M, Järvinen TLN (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32:765–771PubMedCrossRef
32.
Zurück zum Zitat Roy S, Fernhout M, Stanley R, McGee M, Carbone T, Field JR, Dobson P (2010) Tibial interference screw fixation in anterior cruciate ligament reconstruction with and without autograft bone augmentation. Arthroscopy 26:949–956PubMedCrossRef Roy S, Fernhout M, Stanley R, McGee M, Carbone T, Field JR, Dobson P (2010) Tibial interference screw fixation in anterior cruciate ligament reconstruction with and without autograft bone augmentation. Arthroscopy 26:949–956PubMedCrossRef
33.
Zurück zum Zitat Rupp S, Seil R, Schneider A, Kohn DM (1999) Ligament graft initial fixation strength using biodegradable interference screws. J Biomed Mater Res 48:70–74PubMedCrossRef Rupp S, Seil R, Schneider A, Kohn DM (1999) Ligament graft initial fixation strength using biodegradable interference screws. J Biomed Mater Res 48:70–74PubMedCrossRef
34.
Zurück zum Zitat Scheffler S, Sudkamp N, Gockenjan A, Hoffmann R, Weiler A (2002) Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy 18:304–315PubMedCrossRef Scheffler S, Sudkamp N, Gockenjan A, Hoffmann R, Weiler A (2002) Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy 18:304–315PubMedCrossRef
35.
Zurück zum Zitat Trump M, Palathinkal DM, Beaupre L, Otto D, Leung P, Amirfazli A (2011) In vitro biomechanical testing of anterior cruciate ligament reconstruction: Traditional versus physiologically relevant load analysis. Knee 18:193–201PubMedCrossRef Trump M, Palathinkal DM, Beaupre L, Otto D, Leung P, Amirfazli A (2011) In vitro biomechanical testing of anterior cruciate ligament reconstruction: Traditional versus physiologically relevant load analysis. Knee 18:193–201PubMedCrossRef
36.
Zurück zum Zitat Walsh MP, Wijdicks CA, Armitage BM, Westerhaus BD, Parker JB, Laprade RF (2009) The 1:1 versus the 2:2 tunnel-drilling technique: optimization of fixation strength and stiffness in an all-inside double-bundle anterior cruciate ligament reconstruction—a biomechanical study. Am J Sports Med 37:1539–1547PubMedCrossRef Walsh MP, Wijdicks CA, Armitage BM, Westerhaus BD, Parker JB, Laprade RF (2009) The 1:1 versus the 2:2 tunnel-drilling technique: optimization of fixation strength and stiffness in an all-inside double-bundle anterior cruciate ligament reconstruction—a biomechanical study. Am J Sports Med 37:1539–1547PubMedCrossRef
37.
Zurück zum Zitat Weiler A, Hoffmann RFG, Siepe CJ, Kolbeck SF, Südkamp NP (2000) The influence of screw geometry on hamstring tendon interference fit fixation. Am J Sports Med 28:356–359PubMed Weiler A, Hoffmann RFG, Siepe CJ, Kolbeck SF, Südkamp NP (2000) The influence of screw geometry on hamstring tendon interference fit fixation. Am J Sports Med 28:356–359PubMed
38.
Zurück zum Zitat Wijdicks CA, Brand EJ, Nuckley DJ, Johansen S, LaPrade RF, Engebretsen L (2010) Biomechanical evaluation of a medial knee reconstruction with comparison of bioabsorbable interference screw constructs and optimization with a cortical button. Knee Surg Sports Traumatol Arthrosc 18:1532–1541PubMedCrossRef Wijdicks CA, Brand EJ, Nuckley DJ, Johansen S, LaPrade RF, Engebretsen L (2010) Biomechanical evaluation of a medial knee reconstruction with comparison of bioabsorbable interference screw constructs and optimization with a cortical button. Knee Surg Sports Traumatol Arthrosc 18:1532–1541PubMedCrossRef
39.
Zurück zum Zitat Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws. Arthroscopy 22:1204–1210PubMedCrossRef Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws. Arthroscopy 22:1204–1210PubMedCrossRef
Metadaten
Titel
Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction
verfasst von
María Prado
Belén Martín-Castilla
Alejandro Espejo-Reina
José Miguel Serrano-Fernández
Ana Pérez-Blanca
Francisco Ezquerro
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 2/2013
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-1975-9

Weitere Artikel der Ausgabe 2/2013

Knee Surgery, Sports Traumatology, Arthroscopy 2/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.