Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 8/2017

29.04.2017 | Cornea

Comparison of Descemet stripping under continuous air flow, manual air injection and balanced salt solution for DMEK: a pilot study

verfasst von: I. E. Gabbay, I. Bahar, Y. Nahum, E. Livny

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 8/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

Descemet’s membrane endothelial keratoplasty (DMEK) involves removal of the recipient’s Descemet membrane (DM) prior to transplanting the donor’s DM. When using balanced salt solution (BSS) or ophthalmic viscosurgical devices (OVDs), visualization of the host’s DM during its stripping may be inadequate and may result in Descemet remnants and could lead to sub-optimal surgical results. Previous articles described excellent visualization when utilizing air injection but this requires repeated air injection into the anterior chamber (AC). We present a pilot study that compares different techniques under which DM stripping can be performed: with continuous automated air infusion, with manual air infusion, and with BSS.

Methods

We retrospectively compared video footage of DM stripping with BSS, with continuous air and with manual injection of air into the AC to determine DM stripping duration and the number of times the surgeon had to insert and retrieve a surgical instrument from the AC.

Results

Thirty videos of 10 consecutive cases of the three DM stripping techniques were evaluated. DM stripping duration was 3.26 (±1.32), 3.92 (±1.2) and 12.9 (±3.98) minutes for BSS, continuous air flow, and manual air injection, respectively. Frequency of instrument retrieval (FIR) was 3.6 (±1.71), 1.5 (±0.71) and 15.1 (±3.28) for BSS, continuous air flow, and manual air injection, respectively. Continuous air flow and BSS were both statistically different than manual air injection into the AC (p < 0.05), but did not differ from one another statistically.

Conclusion

DM stripping during posterior lamellar surgery is imperative for favorable post-operative results and prevention of complications. Performing this step under air in the AC contributes to better visualization and an efficient surgery.
Literatur
2.
Zurück zum Zitat Dapena I, Moutsouris K, Droutsas K, Ham L, van Dijk K (1960) Melles GRJ (2011) standardized “no-touch” technique for descemet membrane endothelial keratoplasty. Arch Ophthalmol Chic Ill 129:88–94. doi:10.1001/archophthalmol.2010.334 Dapena I, Moutsouris K, Droutsas K, Ham L, van Dijk K (1960) Melles GRJ (2011) standardized “no-touch” technique for descemet membrane endothelial keratoplasty. Arch Ophthalmol Chic Ill 129:88–94. doi:10.​1001/​archophthalmol.​2010.​334
4.
Zurück zum Zitat Rodríguez-Calvo-de-Mora M, Quilendrino R, Ham L, Liarakos VS, van Dijk K, Baydoun L, Dapena I, Oellerich S, Melles GRJ (2015) Clinical outcome of 500 consecutive cases undergoing Descemet’s membrane endothelial keratoplasty. Ophthalmology 122:464–470. doi:10.1016/j.ophtha.2014.09.004 CrossRefPubMed Rodríguez-Calvo-de-Mora M, Quilendrino R, Ham L, Liarakos VS, van Dijk K, Baydoun L, Dapena I, Oellerich S, Melles GRJ (2015) Clinical outcome of 500 consecutive cases undergoing Descemet’s membrane endothelial keratoplasty. Ophthalmology 122:464–470. doi:10.​1016/​j.​ophtha.​2014.​09.​004 CrossRefPubMed
5.
Zurück zum Zitat Bhandari V, Reddy JK, Relekar K, Prabhu V (2015) Descemet’s stripping automated endothelial Keratoplasty versus Descemet’s membrane endothelial Keratoplasty in the fellow eye for Fuchs endothelial dystrophy: a retrospective study. Biomed Res Int 2015:750567. doi:10.1155/2015/750567 CrossRefPubMedPubMedCentral Bhandari V, Reddy JK, Relekar K, Prabhu V (2015) Descemet’s stripping automated endothelial Keratoplasty versus Descemet’s membrane endothelial Keratoplasty in the fellow eye for Fuchs endothelial dystrophy: a retrospective study. Biomed Res Int 2015:750567. doi:10.​1155/​2015/​750567 CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Heinzelmann S, Böhringer D, Eberwein P, Reinhard T, Maier P (2016) Outcomes of Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty from a single centre study. Graefes Arch Clin Exp Ophthalmol. doi:10.1007/s00417-015-3248-z Heinzelmann S, Böhringer D, Eberwein P, Reinhard T, Maier P (2016) Outcomes of Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty from a single centre study. Graefes Arch Clin Exp Ophthalmol. doi:10.​1007/​s00417-015-3248-z
8.
Zurück zum Zitat Groeneveld-van Beek EA, Lie JT, van der Wees J, Bruinsma M, Melles GRJ (2013) Standardized “no-touch” donor tissue preparation for DALK and DMEK: harvesting undamaged anterior and posterior transplants from the same donor cornea. Acta Ophthalmol 91:145–150. doi:10.1111/j.1755-3768.2012.02462.x CrossRefPubMed Groeneveld-van Beek EA, Lie JT, van der Wees J, Bruinsma M, Melles GRJ (2013) Standardized “no-touch” donor tissue preparation for DALK and DMEK: harvesting undamaged anterior and posterior transplants from the same donor cornea. Acta Ophthalmol 91:145–150. doi:10.​1111/​j.​1755-3768.​2012.​02462.​x CrossRefPubMed
10.
Zurück zum Zitat Livny E, Parker JS, van der Kaaij M, Haasdijk ED, van der Wees J, Bruinsma M, Melles GRJ (2014) Postmortem ultrastructural analysis of a cornea transplanted with Descemet membrane endothelial keratoplasty. Cornea 33:790–794. doi:10.1097/ICO.0000000000000156 CrossRefPubMed Livny E, Parker JS, van der Kaaij M, Haasdijk ED, van der Wees J, Bruinsma M, Melles GRJ (2014) Postmortem ultrastructural analysis of a cornea transplanted with Descemet membrane endothelial keratoplasty. Cornea 33:790–794. doi:10.​1097/​ICO.​0000000000000156​ CrossRefPubMed
11.
Zurück zum Zitat Cabrerizo J, Livny E, Musa FU, Leeuwenburgh P, van Dijk K, Melles GRJ (2014) Changes in color vision and contrast sensitivity after descemet membrane endothelial keratoplasty for fuchs endothelial dystrophy. Cornea 33:1010–1015. doi:10.1097/ICO.0000000000000216 CrossRefPubMed Cabrerizo J, Livny E, Musa FU, Leeuwenburgh P, van Dijk K, Melles GRJ (2014) Changes in color vision and contrast sensitivity after descemet membrane endothelial keratoplasty for fuchs endothelial dystrophy. Cornea 33:1010–1015. doi:10.​1097/​ICO.​0000000000000216​ CrossRefPubMed
12.
Zurück zum Zitat van Dijk K, Rodriguez-Calvo-de-Mora M, van Esch H, Frank L, Dapena I, Baydoun L, Oellerich S, Melles GRJ (2016) Two-year refractive outcomes after Descemet membrane endothelial Keratoplasty. Cornea. doi:10.1097/ICO.0000000000001022 van Dijk K, Rodriguez-Calvo-de-Mora M, van Esch H, Frank L, Dapena I, Baydoun L, Oellerich S, Melles GRJ (2016) Two-year refractive outcomes after Descemet membrane endothelial Keratoplasty. Cornea. doi:10.​1097/​ICO.​0000000000001022​
13.
Zurück zum Zitat Karimian F, Sadoughi M-M (2010) Air-assisted descemet stripping automated endothelial keratoplasty with posterior chamber fixation of an aphakic iris-claw lens. J Ophthalmic Vis Res 5:205–210PubMedPubMedCentral Karimian F, Sadoughi M-M (2010) Air-assisted descemet stripping automated endothelial keratoplasty with posterior chamber fixation of an aphakic iris-claw lens. J Ophthalmic Vis Res 5:205–210PubMedPubMedCentral
16.
Zurück zum Zitat Vira S, Shih CY, Ragusa N, Sheyman A, Feder R, Weisenthal RW, Rosenwasser GOD, Hannush SB, Udell IJ, Bouchard CS (2013) Textural interface opacity after descemet stripping automated endothelial keratoplasty: a report of 30 cases and possible etiology. Cornea 32:e54–e59. doi:10.1097/ICO.0b013e31826429d5 CrossRefPubMed Vira S, Shih CY, Ragusa N, Sheyman A, Feder R, Weisenthal RW, Rosenwasser GOD, Hannush SB, Udell IJ, Bouchard CS (2013) Textural interface opacity after descemet stripping automated endothelial keratoplasty: a report of 30 cases and possible etiology. Cornea 32:e54–e59. doi:10.​1097/​ICO.​0b013e31826429d5​ CrossRefPubMed
17.
Zurück zum Zitat Chhadva P, Cabot F, Ziebarth N, Kymionis GD, Yoo SH (2013) Persistent corneal opacity after descemet stripping automated endothelial keratoplasty suggesting inert material deposits into the interface. Cornea 32:1512–1513. doi:10.1097/ICO.0b013e3182a1bc49 CrossRefPubMed Chhadva P, Cabot F, Ziebarth N, Kymionis GD, Yoo SH (2013) Persistent corneal opacity after descemet stripping automated endothelial keratoplasty suggesting inert material deposits into the interface. Cornea 32:1512–1513. doi:10.​1097/​ICO.​0b013e3182a1bc49​ CrossRefPubMed
18.
Zurück zum Zitat Kobayashi A, Yokogawa H, Sugiyama K (2008) Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy--preliminary results and usefulness of double-glide donor insertion technique. Cornea 27(Suppl 1):S62–S69. doi:10.1097/ICO.0b013e31817f38e9 CrossRefPubMed Kobayashi A, Yokogawa H, Sugiyama K (2008) Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy--preliminary results and usefulness of double-glide donor insertion technique. Cornea 27(Suppl 1):S62–S69. doi:10.​1097/​ICO.​0b013e31817f38e9​ CrossRefPubMed
19.
Zurück zum Zitat Melles G, Dapena I (2014) How to get started with standardized “no-touch” descemet membrane endothelial keratoplasty (DMEK), 1. Aufl. Netherlands Institute for Innovative Ocular Surgery (NIIOS), Rotterdam Melles G, Dapena I (2014) How to get started with standardized “no-touch” descemet membrane endothelial keratoplasty (DMEK), 1. Aufl. Netherlands Institute for Innovative Ocular Surgery (NIIOS), Rotterdam
20.
Zurück zum Zitat Dapena I, Ham L, Moutsouris K, Melles GRJ (2010) Incidence of recipient Descemet membrane remnants at the donor-to-stromal interface after descemetorhexis in endothelial keratoplasty. Br J Ophthalmol 94:1689–1690. doi:10.1136/bjo.2010.186189 CrossRefPubMed Dapena I, Ham L, Moutsouris K, Melles GRJ (2010) Incidence of recipient Descemet membrane remnants at the donor-to-stromal interface after descemetorhexis in endothelial keratoplasty. Br J Ophthalmol 94:1689–1690. doi:10.​1136/​bjo.​2010.​186189 CrossRefPubMed
Metadaten
Titel
Comparison of Descemet stripping under continuous air flow, manual air injection and balanced salt solution for DMEK: a pilot study
verfasst von
I. E. Gabbay
I. Bahar
Y. Nahum
E. Livny
Publikationsdatum
29.04.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 8/2017
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-017-3675-0

Weitere Artikel der Ausgabe 8/2017

Graefe's Archive for Clinical and Experimental Ophthalmology 8/2017 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.