Skip to main content
Erschienen in: Surgical Endoscopy 12/2017

18.05.2017

Comparison of the multichannel intraluminal impedance pH and conventional pH for measuring esophageal acid exposure: a propensity score-matched analysis

verfasst von: Masato Hoshino, Nobuo Omura, Fumiaki Yano, Kazuto Tsuboi, Se Ryung Yamamoto, Shunsuke Akimoto, Takahiro Masuda, Hideyuki Kashiwagi, Katsuhiko Yanaga

Erschienen in: Surgical Endoscopy | Ausgabe 12/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

The modalities for evaluating acid reflux in medical care for gastroesophageal reflux disease (GERD) include conventional pH (C-pH), wireless pH (Bravo®) and multichannel intraluminal impedance pH (MII-pH), which have been reported to vary with respect to the duration of acid reflux. In this study, we examined the difference between the acid reflux in C-pH and MII-pH among patients with GERD.

Methods

Prior to initial laparoscopic fundoplication carried out on 297 cases from December 1994 to April 2016, an upper gastrointestinal endoscopy and C-pH or MII-pH were conducted. A propensity score-matched analysis was carried out about five factors including age, sex, BMI, the extent of reflux esophagitis (Los Angeles classification), and the presence of hiatal hernia (HH), ultimately leading to the creation of a C-pH group (81 cases) and MII-pH group (81 cases) as the subjects.

Results

Concerning pH < 4 holding time (18.9 vs. 7.3%, p < 0.001), DeMeester score (58.5 vs. 24.4, p < 0.001), and the number of times reflux continued for longer than 5 min (8.8 vs. 4.1 times/day, p = 0.002), the C-pH group had significantly higher values for each, while the positive rate of acid reflux (Positive pH) was significantly higher in the C-pH group (p < 0.001), at 80% in the C-pH group and 42% in the MII-pH group. In terms of the correlation between the extent of reflux esophagitis and pH < 4 holding time, a moderate level of positive correlation was seen in both the C-pH group and MII-pH group (r of each = 0.427, r = 0.408); moreover, regardless of the presence of HH, the holding time was significantly higher in the C-pH group than the MII-pH group (p of each <0.001, p = 0.040).

Conclusion

While the values of each parameter regarding acid reflux are calculated as lower in MII-pH than in C-pH, there is no difference in the evaluation of the pathology between the two modalities.
Literatur
1.
Zurück zum Zitat Johnson LF, Demeester TR (1974) Twenty-four-hour pH monitoring of the distal esophagus. A quantitative measure of gastroesophageal reflux. Am J Gastroenterol 62(4):325–332PubMed Johnson LF, Demeester TR (1974) Twenty-four-hour pH monitoring of the distal esophagus. A quantitative measure of gastroesophageal reflux. Am J Gastroenterol 62(4):325–332PubMed
2.
Zurück zum Zitat Hirano I (2006) Review article: modern technology in the diagnosis of gastro-oesophageal reflux disease—Bilitec, intraluminal impedance and Bravo capsule pH monitoring. Aliment Pharmacol Ther 23(Suppl 1):12–24CrossRefPubMed Hirano I (2006) Review article: modern technology in the diagnosis of gastro-oesophageal reflux disease—Bilitec, intraluminal impedance and Bravo capsule pH monitoring. Aliment Pharmacol Ther 23(Suppl 1):12–24CrossRefPubMed
3.
Zurück zum Zitat Wise JL, Murray JA (2007) Utilising multichannel intraluminal impedance for diagnosing GERD: a review. Dis Esophagus 20(2):83–88CrossRefPubMed Wise JL, Murray JA (2007) Utilising multichannel intraluminal impedance for diagnosing GERD: a review. Dis Esophagus 20(2):83–88CrossRefPubMed
4.
Zurück zum Zitat Mishima I, Adachi K, Arima N, Amano K, Takashima T, Moritani M, Furuta K, Kinoshita Y (2005) Prevalence of endoscopically negative and positive gastroesophageal reflux disease in the Japanese. Scand J Gastroenterol 40(9):1005–1009CrossRefPubMed Mishima I, Adachi K, Arima N, Amano K, Takashima T, Moritani M, Furuta K, Kinoshita Y (2005) Prevalence of endoscopically negative and positive gastroesophageal reflux disease in the Japanese. Scand J Gastroenterol 40(9):1005–1009CrossRefPubMed
5.
Zurück zum Zitat Shay S, Tutuian R, Sifrim D, Vela M, Wise J, Balaji N, Zhang X, Adhami T, Murray J, Peters J, Castell D (2004) Twenty-four hour ambulatory simultaneous impedance and pH monitoring: a multicenter report of normal values from 60 healthy volunteers. Am J Gastroenterol 99(6):1037–1043CrossRefPubMed Shay S, Tutuian R, Sifrim D, Vela M, Wise J, Balaji N, Zhang X, Adhami T, Murray J, Peters J, Castell D (2004) Twenty-four hour ambulatory simultaneous impedance and pH monitoring: a multicenter report of normal values from 60 healthy volunteers. Am J Gastroenterol 99(6):1037–1043CrossRefPubMed
6.
Zurück zum Zitat Xiao YL, Lin JK, Cheung TK, Wong NY, Yang L, Hung IF, Wong BC, Chen MH (2009) Normal values of 24-hour combined esophageal multichannel intraluminal impedance and pH monitoring in the Chinese population. Digestion 79(2):109–114CrossRefPubMed Xiao YL, Lin JK, Cheung TK, Wong NY, Yang L, Hung IF, Wong BC, Chen MH (2009) Normal values of 24-hour combined esophageal multichannel intraluminal impedance and pH monitoring in the Chinese population. Digestion 79(2):109–114CrossRefPubMed
7.
Zurück zum Zitat Han MS, Lada MJ, Nieman DR, Tschoner A, Peyre CG, Jones CE, Watson TJ, Peters JH (2015) 24-h multichannel intraluminal impedance-pH monitoring may be an inadequate test for detecting gastroesophageal reflux in patients with mixed typical and atypical symptoms. Surg Endosc 29(7):1700–1708CrossRefPubMed Han MS, Lada MJ, Nieman DR, Tschoner A, Peyre CG, Jones CE, Watson TJ, Peters JH (2015) 24-h multichannel intraluminal impedance-pH monitoring may be an inadequate test for detecting gastroesophageal reflux in patients with mixed typical and atypical symptoms. Surg Endosc 29(7):1700–1708CrossRefPubMed
8.
Zurück zum Zitat Yano F, Omura N, Tsuboi K, Hoshino M, Yamamoto SR, Akimoto S, Masuda T, Mitsumori N, Kashiwagi H, Yanaga K (2017) Standard values of 24-h multichannel intraluminal impedance-pH monitoring for the Japanese. Esophagus 14(1):91–96CrossRef Yano F, Omura N, Tsuboi K, Hoshino M, Yamamoto SR, Akimoto S, Masuda T, Mitsumori N, Kashiwagi H, Yanaga K (2017) Standard values of 24-h multichannel intraluminal impedance-pH monitoring for the Japanese. Esophagus 14(1):91–96CrossRef
9.
Zurück zum Zitat Ndebia EJ, Sammon AM, Umapathy E, Iputo JE (2016) Normal values of 24-hour ambulatory esophageal impedance-pH monitoring in a rural South African cohort of healthy participants. Dis Esophagus 29(4):385–391CrossRefPubMed Ndebia EJ, Sammon AM, Umapathy E, Iputo JE (2016) Normal values of 24-hour ambulatory esophageal impedance-pH monitoring in a rural South African cohort of healthy participants. Dis Esophagus 29(4):385–391CrossRefPubMed
10.
Zurück zum Zitat Lord RV, DeMeester SR, Peters JH, Hagen JA, Elyssnia D, Sheth CT, DeMeester TR (2009) Hiatal hernia, lower esophageal sphincter incompetence, and effectiveness of Nissen fundoplication in the spectrum of gastroesophageal reflux disease. J Gastrointest Surg 13(4):602–610CrossRefPubMed Lord RV, DeMeester SR, Peters JH, Hagen JA, Elyssnia D, Sheth CT, DeMeester TR (2009) Hiatal hernia, lower esophageal sphincter incompetence, and effectiveness of Nissen fundoplication in the spectrum of gastroesophageal reflux disease. J Gastrointest Surg 13(4):602–610CrossRefPubMed
11.
Zurück zum Zitat Pandolfino JE, Schreiner MA, Lee TJ, Zhang Q, Boniquit C, Kahrilas PJ (2005) Comparison of the Bravo wireless and Digitrapper catheter-based pH monitoring systems for measuring esophageal acid exposure. Am J Gastroenterol 100(7):1466–1476CrossRefPubMed Pandolfino JE, Schreiner MA, Lee TJ, Zhang Q, Boniquit C, Kahrilas PJ (2005) Comparison of the Bravo wireless and Digitrapper catheter-based pH monitoring systems for measuring esophageal acid exposure. Am J Gastroenterol 100(7):1466–1476CrossRefPubMed
12.
Zurück zum Zitat Hila A, Agrawal A, Castell DO (2007) Combined multichannel intraluminal impedance and pH esophageal testing compared to pH alone for diagnosing both acid and weakly acidic gastroesophageal reflux. Clin Gastroenterol Hepatol 5(2):172–177CrossRefPubMed Hila A, Agrawal A, Castell DO (2007) Combined multichannel intraluminal impedance and pH esophageal testing compared to pH alone for diagnosing both acid and weakly acidic gastroesophageal reflux. Clin Gastroenterol Hepatol 5(2):172–177CrossRefPubMed
13.
Zurück zum Zitat Ott DJ, Glauser SJ, Ledbetter MS, Chen MY, Koufman JA, Gelfand DW (1995) Association of hiatal hernia and gastroesophageal reflux: correlation between presence and size of hiatal hernia and 24-hour pH monitoring of the esophagus. AJR Am J Roentgenol 165(3):557–559CrossRefPubMed Ott DJ, Glauser SJ, Ledbetter MS, Chen MY, Koufman JA, Gelfand DW (1995) Association of hiatal hernia and gastroesophageal reflux: correlation between presence and size of hiatal hernia and 24-hour pH monitoring of the esophagus. AJR Am J Roentgenol 165(3):557–559CrossRefPubMed
14.
Zurück zum Zitat Patti MG, Goldberg HI, Arcerito M, Bortolasi L, Tong J, Way LW (1996) Hiatal hernia size affects lower esophageal sphincter function, esophageal acid exposure, and the degree of mucosal injury. Am J Surg 171(1):182–186CrossRefPubMed Patti MG, Goldberg HI, Arcerito M, Bortolasi L, Tong J, Way LW (1996) Hiatal hernia size affects lower esophageal sphincter function, esophageal acid exposure, and the degree of mucosal injury. Am J Surg 171(1):182–186CrossRefPubMed
15.
Zurück zum Zitat Jones MP, Sloan SS, Rabine JC, Ebert CC, Huang CF, Kahrilas PJ (2001) Hiatal hernia size is the dominant determinant of esophagitis presence and severity in gastroesophageal reflux disease. Am J Gastroenterol 96(6):1711–1717CrossRefPubMed Jones MP, Sloan SS, Rabine JC, Ebert CC, Huang CF, Kahrilas PJ (2001) Hiatal hernia size is the dominant determinant of esophagitis presence and severity in gastroesophageal reflux disease. Am J Gastroenterol 96(6):1711–1717CrossRefPubMed
16.
Zurück zum Zitat Emerenziani S, Habib FI, Ribolsi M, Caviglia R, Guarino MP, Petitti T, Cicala M (2006) Effect of hiatal hernia on proximal oesophageal acid clearance in gastro-oesophageal reflux disease patients. Aliment Pharmacol Ther 23(6):751–757CrossRefPubMed Emerenziani S, Habib FI, Ribolsi M, Caviglia R, Guarino MP, Petitti T, Cicala M (2006) Effect of hiatal hernia on proximal oesophageal acid clearance in gastro-oesophageal reflux disease patients. Aliment Pharmacol Ther 23(6):751–757CrossRefPubMed
17.
Zurück zum Zitat Lundell LR, Dent J, Bennett JR, Blum AL, Armstrong D, Galmiche JP, Johnson F, Hongo M, Richter JE, Spechler SJ, Tytgat GN, Wallin L (1999) Endoscopic assessment of oesophagitis: clinical and functional correlates and further validation of the Los Angeles classification. Gut 45(2):172–180CrossRefPubMedPubMedCentral Lundell LR, Dent J, Bennett JR, Blum AL, Armstrong D, Galmiche JP, Johnson F, Hongo M, Richter JE, Spechler SJ, Tytgat GN, Wallin L (1999) Endoscopic assessment of oesophagitis: clinical and functional correlates and further validation of the Los Angeles classification. Gut 45(2):172–180CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Miwa H, Yokoyama T, Hori K, Sakagami T, Oshima T, Tomita T, Fujiwara Y, Saita H, Itou T, Ogawa H, Nakamura Y, Kishi K, Murayama Y, Hayashi E, Kobayashi K, Tano N, Matsushita K, Kawamoto H, Sawada Y, Ohkawa A, Arai E, Nagao K, Hamamoto N, Sugiyasu Y, Sugimoto K, Hara H, Tanimura M, Honda Y, Isozaki K, Noda S, Kubota S, Himeno S (2008) Interobserver agreement in endoscopic evaluation of reflux esophagitis using a modified Los Angeles classification incorporating grades N and M: a validation study in a cohort of Japanese endoscopists. Dis Esophagus 21(4):355–363CrossRefPubMed Miwa H, Yokoyama T, Hori K, Sakagami T, Oshima T, Tomita T, Fujiwara Y, Saita H, Itou T, Ogawa H, Nakamura Y, Kishi K, Murayama Y, Hayashi E, Kobayashi K, Tano N, Matsushita K, Kawamoto H, Sawada Y, Ohkawa A, Arai E, Nagao K, Hamamoto N, Sugiyasu Y, Sugimoto K, Hara H, Tanimura M, Honda Y, Isozaki K, Noda S, Kubota S, Himeno S (2008) Interobserver agreement in endoscopic evaluation of reflux esophagitis using a modified Los Angeles classification incorporating grades N and M: a validation study in a cohort of Japanese endoscopists. Dis Esophagus 21(4):355–363CrossRefPubMed
Metadaten
Titel
Comparison of the multichannel intraluminal impedance pH and conventional pH for measuring esophageal acid exposure: a propensity score-matched analysis
verfasst von
Masato Hoshino
Nobuo Omura
Fumiaki Yano
Kazuto Tsuboi
Se Ryung Yamamoto
Shunsuke Akimoto
Takahiro Masuda
Hideyuki Kashiwagi
Katsuhiko Yanaga
Publikationsdatum
18.05.2017
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 12/2017
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-017-5595-9

Weitere Artikel der Ausgabe 12/2017

Surgical Endoscopy 12/2017 Zur Ausgabe

Deutlich weniger Infektionen: Wundprotektoren schützen!

08.05.2024 Postoperative Wundinfektion Nachrichten

Der Einsatz von Wundprotektoren bei offenen Eingriffen am unteren Gastrointestinaltrakt schützt vor Infektionen im Op.-Gebiet – und dient darüber hinaus der besseren Sicht. Das bestätigt mit großer Robustheit eine randomisierte Studie im Fachblatt JAMA Surgery.

Chirurginnen und Chirurgen sind stark suizidgefährdet

07.05.2024 Suizid Nachrichten

Der belastende Arbeitsalltag wirkt sich negativ auf die psychische Gesundheit der Angehörigen ärztlicher Berufsgruppen aus. Chirurginnen und Chirurgen bilden da keine Ausnahme, im Gegenteil.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Echinokokkose medikamentös behandeln oder operieren?

06.05.2024 DCK 2024 Kongressbericht

Die Therapie von Echinokokkosen sollte immer in spezialisierten Zentren erfolgen. Eine symptomlose Echinokokkose kann – egal ob von Hunde- oder Fuchsbandwurm ausgelöst – konservativ erfolgen. Wenn eine Op. nötig ist, kann es sinnvoll sein, vorher Zysten zu leeren und zu desinfizieren. 

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.