Background

The detection of gastroesophageal reflux (GERD) via pH testing is the key component of the evaluation of patients considered for antireflux surgery. Two common pH testing systems exist, a multichannel, intraluminal impedance-pH monitoring (MII-pH) catheter, and wireless (Bravo®) capsule; however, discrepancies between the two systems exist. In patients with atypical symptoms, MII-pH catheter is often used preferentially. We aimed to elucidate the magnitude of this discrepancy and to assess the diagnostic value of MII-pH and the Bravo wireless capsule in a population of patients with mixed respiratory and typical symptoms.

Methods

The study population consisted of 66 patients tested with MII-pH and Bravo pH testing within 90 days between July 2009 and 2013. All patients presented with laryngo-pharyngo-respiratory (LPR) symptoms. Patient demographics, symptomatology, manometric and endoscopic findings, and pH monitoring parameters were analyzed. Patients were divided into four comparison groups: both pH tests positive, MII-pH negative/Bravo positive, MII-pH positive/Bravo negative, and both pH tests negative.

Results

Nearly half of the patients (44 %) had discordant pH test results. Of these, 90 % (26/29) had a negative MII-pH but positive Bravo study. In this group, the difference in the DeMeester score was large, a median of 29.3. These patients had a higher BMI (28.5 vs. 26.1, p = 0.0357), were more likely to complain of heartburn (50 vs. 23 %, p = 0.0110), to have a hiatal hernia, (85 vs. 53 %, p = 0.0075) and a structurally defective lower esophageal sphincter (LES, 85 vs. 58 %, p = 0.0208).

Conclusions

In patients with LPR symptoms, we found a high prevalence of discordant esophageal pH results, most commonly a negative MII-pH catheter and positive Bravo. As these patients exhibited characteristics consistent with GERD (heartburn, defective LES, hiatal hernia), the Bravo results are likely true. A 24-h MII-pH catheter study may be inadequate to diagnose GERD in this patient population.
Literatur
1.
Zurück zum Zitat Hirano I, Richter JE (2007) ACG practice guidelines: esophageal reflux testing. Am J Gastroenterol 102(3):668–685PubMedCrossRef Hirano I, Richter JE (2007) ACG practice guidelines: esophageal reflux testing. Am J Gastroenterol 102(3):668–685PubMedCrossRef
2.
Zurück zum Zitat Campos GM et al (1999) Multivariate analysis of factors predicting outcome after laparoscopic Nissen fundoplication. J Gastrointest Surg 3(3):292–300PubMedCrossRef Campos GM et al (1999) Multivariate analysis of factors predicting outcome after laparoscopic Nissen fundoplication. J Gastrointest Surg 3(3):292–300PubMedCrossRef
3.
Zurück zum Zitat Franzen T, Grahn LT (2002) Reliability of 24-hour oesophageal pH monitoring under standardized conditions. Scand J Gastroenterol 37(1):6–8PubMedCrossRef Franzen T, Grahn LT (2002) Reliability of 24-hour oesophageal pH monitoring under standardized conditions. Scand J Gastroenterol 37(1):6–8PubMedCrossRef
4.
Zurück zum Zitat Weber C, Davis CS, Fisichella PM (2011) Current applications of evolving methodologies in gastroesophageal reflux disease testing. Dig Liver Dis 43(5):353–357PubMedCrossRef Weber C, Davis CS, Fisichella PM (2011) Current applications of evolving methodologies in gastroesophageal reflux disease testing. Dig Liver Dis 43(5):353–357PubMedCrossRef
5.
Zurück zum Zitat Ayazi S et al (2011) Day-to-day discrepancy in Bravo pH monitoring is related to the degree of deterioration of the lower esophageal sphincter and severity of reflux disease. Surg Endosc 25(7):2219–2223PubMedCentralPubMedCrossRef Ayazi S et al (2011) Day-to-day discrepancy in Bravo pH monitoring is related to the degree of deterioration of the lower esophageal sphincter and severity of reflux disease. Surg Endosc 25(7):2219–2223PubMedCentralPubMedCrossRef
6.
Zurück zum Zitat Pandolfino JE et al (2005) Comparison of the Bravo wireless and Digitrapper catheter-based pH monitoring systems for measuring esophageal acid exposure. Am J Gastroenterol 100(7):1466–1476PubMedCrossRef Pandolfino JE et al (2005) Comparison of the Bravo wireless and Digitrapper catheter-based pH monitoring systems for measuring esophageal acid exposure. Am J Gastroenterol 100(7):1466–1476PubMedCrossRef
7.
Zurück zum Zitat Pandolfino JE et al (2005) Acid reflux event detection using the Bravo wireless versus the Slimline catheter pH systems: why are the numbers so different? Gut 54(12):1687–1692PubMedCentralPubMedCrossRef Pandolfino JE et al (2005) Acid reflux event detection using the Bravo wireless versus the Slimline catheter pH systems: why are the numbers so different? Gut 54(12):1687–1692PubMedCentralPubMedCrossRef
8.
Zurück zum Zitat Hakanson BS et al (2009) Comparison of wireless 48-h (Bravo) versus traditional ambulatory 24-h esophageal pH monitoring. Scand J Gastroenterol 44(3):276–283PubMedCrossRef Hakanson BS et al (2009) Comparison of wireless 48-h (Bravo) versus traditional ambulatory 24-h esophageal pH monitoring. Scand J Gastroenterol 44(3):276–283PubMedCrossRef
9.
Zurück zum Zitat McCollough M et al (2004) Proximal sensor data from routine dual-sensor esophageal pH monitoring is often inaccurate. Dig Dis Sci 49(10):1607–1611PubMedCrossRef McCollough M et al (2004) Proximal sensor data from routine dual-sensor esophageal pH monitoring is often inaccurate. Dig Dis Sci 49(10):1607–1611PubMedCrossRef
10.
Zurück zum Zitat Vaezi MF, Schroeder PL, Richter JE (1997) Reproducibility of proximal probe pH parameters in 24-hour ambulatory esophageal pH monitoring. Am J Gastroenterol 92(5):825–829PubMed Vaezi MF, Schroeder PL, Richter JE (1997) Reproducibility of proximal probe pH parameters in 24-hour ambulatory esophageal pH monitoring. Am J Gastroenterol 92(5):825–829PubMed
11.
Zurück zum Zitat Ayazi S et al (2009) Bravo catheter-free pH monitoring: normal values, concordance, optimal diagnostic thresholds, and accuracy. Clin Gastroenterol Hepatol 7(1):60–67PubMedCrossRef Ayazi S et al (2009) Bravo catheter-free pH monitoring: normal values, concordance, optimal diagnostic thresholds, and accuracy. Clin Gastroenterol Hepatol 7(1):60–67PubMedCrossRef
12.
Zurück zum Zitat Kim TH et al (2008) Pepsin detection in the sputum/saliva for the diagnosis of gastroesophageal reflux disease in patients with clinically suspected atypical gastroesophageal reflux disease symptoms. Digestion 77(3–4):201–206PubMedCrossRef Kim TH et al (2008) Pepsin detection in the sputum/saliva for the diagnosis of gastroesophageal reflux disease in patients with clinically suspected atypical gastroesophageal reflux disease symptoms. Digestion 77(3–4):201–206PubMedCrossRef
13.
Zurück zum Zitat Pandolfino JE et al (2003) Ambulatory esophageal pH monitoring using a wireless system. Am J Gastroenterol 98(4):740–749PubMedCrossRef Pandolfino JE et al (2003) Ambulatory esophageal pH monitoring using a wireless system. Am J Gastroenterol 98(4):740–749PubMedCrossRef
14.
Zurück zum Zitat Scarpulla G et al (2007) The impact of prolonged pH measurements on the diagnosis of gastroesophageal reflux disease: 4-day wireless pH studies. Am J Gastroenterol 102(12):2642–2647PubMedCrossRef Scarpulla G et al (2007) The impact of prolonged pH measurements on the diagnosis of gastroesophageal reflux disease: 4-day wireless pH studies. Am J Gastroenterol 102(12):2642–2647PubMedCrossRef
15.
Zurück zum Zitat Ahlawat SK et al (2006) Day-to-day variability in acid reflux patterns using the BRAVO pH monitoring system. J Clin Gastroenterol 40(1):20–24PubMedCrossRef Ahlawat SK et al (2006) Day-to-day variability in acid reflux patterns using the BRAVO pH monitoring system. J Clin Gastroenterol 40(1):20–24PubMedCrossRef
16.
Zurück zum Zitat Grigolon A et al (2011) Diagnostic yield of 96-h wireless pH monitoring and usefulness in patients’ management. Scand J Gastroenterol 46(5):522–530PubMedCrossRef Grigolon A et al (2011) Diagnostic yield of 96-h wireless pH monitoring and usefulness in patients’ management. Scand J Gastroenterol 46(5):522–530PubMedCrossRef
17.
Zurück zum Zitat des Varannes SB et al (2005) Simultaneous recordings of oesophageal acid exposure with conventional pH monitoring and a wireless system (Bravo). Gut 54(12):1682–1686PubMedCentralPubMedCrossRef des Varannes SB et al (2005) Simultaneous recordings of oesophageal acid exposure with conventional pH monitoring and a wireless system (Bravo). Gut 54(12):1682–1686PubMedCentralPubMedCrossRef
18.
Zurück zum Zitat Williams RB et al (1999) Esophagopharyngeal acid regurgitation: dual pH monitoring criteria for its detection and insights into mechanisms. Gastroenterology 117(5):1051–1061PubMedCrossRef Williams RB et al (1999) Esophagopharyngeal acid regurgitation: dual pH monitoring criteria for its detection and insights into mechanisms. Gastroenterology 117(5):1051–1061PubMedCrossRef
19.
Zurück zum Zitat Pandolfino JE, Kwiatek MA (2008) Use and utility of the Bravo pH capsule. J Clin Gastroenterol 42(5):571–578PubMedCrossRef Pandolfino JE, Kwiatek MA (2008) Use and utility of the Bravo pH capsule. J Clin Gastroenterol 42(5):571–578PubMedCrossRef
20.
Zurück zum Zitat Brown SR et al (2011) Clinical outcomes of atypical extra-esophageal reflux symptoms following laparoscopic antireflux surgery. Surg Endosc 25(12):3852–3858PubMedCrossRef Brown SR et al (2011) Clinical outcomes of atypical extra-esophageal reflux symptoms following laparoscopic antireflux surgery. Surg Endosc 25(12):3852–3858PubMedCrossRef
21.
Zurück zum Zitat Hamdy E et al (2009) Response of atypical symptoms of GERD to antireflux surgery. Hepatogastroenterology 56(90):403–406PubMed Hamdy E et al (2009) Response of atypical symptoms of GERD to antireflux surgery. Hepatogastroenterology 56(90):403–406PubMed
22.
Zurück zum Zitat Farrell TM et al (2001) Response of atypical symptoms of gastro-oesophageal reflux to antireflux surgery. Br J Surg 88(12):1649–1652PubMedCrossRef Farrell TM et al (2001) Response of atypical symptoms of gastro-oesophageal reflux to antireflux surgery. Br J Surg 88(12):1649–1652PubMedCrossRef
23.
Zurück zum Zitat Johnson WE et al (1996) Outcome of respiratory symptoms after antireflux surgery on patients with gastroesophageal reflux disease. Arch Surg 131(5):489–492PubMedCrossRef Johnson WE et al (1996) Outcome of respiratory symptoms after antireflux surgery on patients with gastroesophageal reflux disease. Arch Surg 131(5):489–492PubMedCrossRef
Metadaten
Titel
24-h multichannel intraluminal impedance-pH monitoring may be an inadequate test for detecting gastroesophageal reflux in patients with mixed typical and atypical symptoms
verfasst von
Michelle S. Han
Michal J. Lada
Dylan R. Nieman
Andreas Tschoner
Christian G. Peyre
Carolyn E. Jones
Thomas J. Watson
Jeffrey H. Peters
Publikationsdatum
01.07.2015
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 7/2015
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-014-3867-1

Weitere Artikel der Ausgabe 7/2015

Surgical Endoscopy 7/2015 Zur Ausgabe

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Deutlich weniger Infektionen: Wundprotektoren schützen!

08.05.2024 Postoperative Wundinfektion Nachrichten

Der Einsatz von Wundprotektoren bei offenen Eingriffen am unteren Gastrointestinaltrakt schützt vor Infektionen im Op.-Gebiet – und dient darüber hinaus der besseren Sicht. Das bestätigt mit großer Robustheit eine randomisierte Studie im Fachblatt JAMA Surgery.

Chirurginnen und Chirurgen sind stark suizidgefährdet

07.05.2024 Suizid Nachrichten

Der belastende Arbeitsalltag wirkt sich negativ auf die psychische Gesundheit der Angehörigen ärztlicher Berufsgruppen aus. Chirurginnen und Chirurgen bilden da keine Ausnahme, im Gegenteil.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.