Compatibility of temporary pacemaker myocardial pacing leads with magnetic resonance imaging: an ex vivo tissue study

verfasst von: Alexander Pfeil, Stefanie Drobnik, Reinhard Rzanny, Anas Aboud, Joachim Böttcher, Peter Schmidt, Christian Ortmann, Gita Mall, Khosro Hekmat, Bernhard Brehm, Juergen Reichenbach, Thomas E. Mayer, Gunter Wolf, Andreas Hansch

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 2/2012

Einloggen, um Zugang zu erhalten

Abstract

The presence of temporary myocardial pacing leads is considered a safety contraindication for magnetic resonance imaging (MRI). The aim of this ex vivo tissue study was to measure the heating effects at the tip of the leads using proton magnetic resonance spectroscopy (1HMRS) thermometry. The tissue effects were verified by histological analyses. Pig hearts with implanted temporary pacemaker myocardial pacing leads were examined by whole-body MRI at 1.5 Tesla. The tests were performed either by a sequence with high specific absorption rate (SAR) or by standard clinical sequences with lower SAR. Temperature changes were detected via 1HMRS thermometry, by monitoring the frequency difference between water protons and the reference signals of N-methyl protons of creatine/phosphocreatine (Cr/PCr) and trimethylamine (TMA). Histology was performed using several staining techniques. Standard low-SAR and high-SAR sequences did not cause significant temperature increases in the myocardial tissue surrounding the implanted leads. There were no histopathological signs of thermal damage around the tips of the leads in any of the hearts or in a control implanted heart not subjected to MRI. The present data suggest that temporary pacemaker myocardial pacing leads may be compatible with MR scanning at 1.5 Tesla. However, further in vivo studies and carefully monitored patient studies are needed before final safety recommendations can be made.
Literatur
1.
Zurück zum Zitat Newman MF, Mathew JP, Grocott HP, Mackensen GB, Monk T, Welsh-Bohmer KA, Blumenthal JA, Laskowitz DT, Mark DB (2006) Central nervous system injury associated with cardiac surgery. Lancet 368(9536):694–703PubMedCrossRef Newman MF, Mathew JP, Grocott HP, Mackensen GB, Monk T, Welsh-Bohmer KA, Blumenthal JA, Laskowitz DT, Mark DB (2006) Central nervous system injury associated with cardiac surgery. Lancet 368(9536):694–703PubMedCrossRef
2.
Zurück zum Zitat Grocott HP, Yoshitani K (2007) Neuroprotection during cardiac surgery. J Anesth 21(3):367–377PubMedCrossRef Grocott HP, Yoshitani K (2007) Neuroprotection during cardiac surgery. J Anesth 21(3):367–377PubMedCrossRef
3.
Zurück zum Zitat Roach GW, Kanchuger M, Mangano CM, Newman M, Nussmeier N, Wolman R, Aggarwal A, Marschall K, Graham SH, Ley C (1996) Adverse cerebral outcomes after coronary bypass surgery. Multicenter Study of Perioperative Ischemia Research Group and the Ischemia Research and Education Foundation Investigators. N Engl J Med 335(25):1857–1863PubMedCrossRef Roach GW, Kanchuger M, Mangano CM, Newman M, Nussmeier N, Wolman R, Aggarwal A, Marschall K, Graham SH, Ley C (1996) Adverse cerebral outcomes after coronary bypass surgery. Multicenter Study of Perioperative Ischemia Research Group and the Ischemia Research and Education Foundation Investigators. N Engl J Med 335(25):1857–1863PubMedCrossRef
4.
Zurück zum Zitat Levine GN, Gomes AS, Arai AE, Bluemke DA, Flamm SD, Kanal E, Manning WJ, Martin ET, Smith JM, Wilke N, Shellock FS (2007) Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation 116(24):2878–2891PubMedCrossRef Levine GN, Gomes AS, Arai AE, Bluemke DA, Flamm SD, Kanal E, Manning WJ, Martin ET, Smith JM, Wilke N, Shellock FS (2007) Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation 116(24):2878–2891PubMedCrossRef
5.
Zurück zum Zitat Rezai AR, Phillips M, Baker KB, Sharan AD, Nyenhuis J, Tkach J, Henderson J, Shellock FG (2004) Neurostimulation system used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations. Invest Radiol 39(5):300–303PubMedCrossRef Rezai AR, Phillips M, Baker KB, Sharan AD, Nyenhuis J, Tkach J, Henderson J, Shellock FG (2004) Neurostimulation system used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations. Invest Radiol 39(5):300–303PubMedCrossRef
6.
Zurück zum Zitat Shellock FG, Crues JV (2004) MR procedures: biologic effects, safety, and patient care. Radiology 232(3):635–652PubMedCrossRef Shellock FG, Crues JV (2004) MR procedures: biologic effects, safety, and patient care. Radiology 232(3):635–652PubMedCrossRef
7.
Zurück zum Zitat Achenbach S, Moshage W, Diem B, Bieberle T, Schibgilla V, Bachmann K (1997) Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. Am Heart J 134(3):467–473PubMedCrossRef Achenbach S, Moshage W, Diem B, Bieberle T, Schibgilla V, Bachmann K (1997) Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. Am Heart J 134(3):467–473PubMedCrossRef
8.
Zurück zum Zitat Gimbel J (2001) Implantable pacemaker and defibrillator safety in the MR environment: new thoughts for the new millennium. In: Special Cross-Specialty Categorical Course in Diagnostic Radiology: Practical MR Safety Considerations for Physicians, Physicists, and Technologists. Radiological Society of North America, Oak Lawn, pp 69–76 Gimbel J (2001) Implantable pacemaker and defibrillator safety in the MR environment: new thoughts for the new millennium. In: Special Cross-Specialty Categorical Course in Diagnostic Radiology: Practical MR Safety Considerations for Physicians, Physicists, and Technologists. Radiological Society of North America, Oak Lawn, pp 69–76
9.
Zurück zum Zitat Duru F, Luechinger R, Scheidegger MB, Luscher TF, Boesiger P, Candinas R (2001) Pacing in magnetic resonance imaging environment: clinical and technical considerations on compatibility. Eur Heart J 22(2):113–124PubMedCrossRef Duru F, Luechinger R, Scheidegger MB, Luscher TF, Boesiger P, Candinas R (2001) Pacing in magnetic resonance imaging environment: clinical and technical considerations on compatibility. Eur Heart J 22(2):113–124PubMedCrossRef
10.
Zurück zum Zitat Luechinger R, Duru F, Scheidegger MB, Boesiger P, Candinas R (2001) Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs. Pacing Clin Electrophysiol 24(2):199–205PubMedCrossRef Luechinger R, Duru F, Scheidegger MB, Boesiger P, Candinas R (2001) Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs. Pacing Clin Electrophysiol 24(2):199–205PubMedCrossRef
11.
Zurück zum Zitat Pavlicek W, Geisinger M, Castle L, Borkowski GP, Meaney TF, Bream BL, Gallagher JH (1983) The effects of nuclear magnetic resonance on patients with cardiac pacemakers. Radiology 147(1):149–153PubMed Pavlicek W, Geisinger M, Castle L, Borkowski GP, Meaney TF, Bream BL, Gallagher JH (1983) The effects of nuclear magnetic resonance on patients with cardiac pacemakers. Radiology 147(1):149–153PubMed
12.
Zurück zum Zitat Hayes DL, Holmes DR Jr, Gray JE (1987) Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers. J Am Coll Cardiol 10(4):782–786PubMedCrossRef Hayes DL, Holmes DR Jr, Gray JE (1987) Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers. J Am Coll Cardiol 10(4):782–786PubMedCrossRef
13.
Zurück zum Zitat Holmes DR Jr, Hayes DL, Gray JE, Merideth J (1986) The effects of magnetic resonance imaging on implantable pulse generators. Pacing Clin Electrophysiol 9(3):360–370PubMedCrossRef Holmes DR Jr, Hayes DL, Gray JE, Merideth J (1986) The effects of magnetic resonance imaging on implantable pulse generators. Pacing Clin Electrophysiol 9(3):360–370PubMedCrossRef
14.
Zurück zum Zitat Fontaine JM, Mohamed FB, Gottlieb C, Callans DJ, Marchlinski FE (1998) Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging. Pacing Clin Electrophysiol 21(6):1336–1339PubMedCrossRef Fontaine JM, Mohamed FB, Gottlieb C, Callans DJ, Marchlinski FE (1998) Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging. Pacing Clin Electrophysiol 21(6):1336–1339PubMedCrossRef
15.
Zurück zum Zitat Fetter J, Aram G, Holmes DR Jr, Gray JE, Hayes DL (1984) The effects of nuclear magnetic resonance imagers on external and implantable pulse generators. Pacing Clin Electrophysiol 7(4):720–727PubMedCrossRef Fetter J, Aram G, Holmes DR Jr, Gray JE, Hayes DL (1984) The effects of nuclear magnetic resonance imagers on external and implantable pulse generators. Pacing Clin Electrophysiol 7(4):720–727PubMedCrossRef
16.
Zurück zum Zitat Erlebacher JA, Cahill PT, Pannizzo F, Knowles RJ (1986) Effect of magnetic resonance imaging on DDD pacemakers. Am J Cardiol 57(6):437–440PubMedCrossRef Erlebacher JA, Cahill PT, Pannizzo F, Knowles RJ (1986) Effect of magnetic resonance imaging on DDD pacemakers. Am J Cardiol 57(6):437–440PubMedCrossRef
17.
Zurück zum Zitat Gimbel JR, Johnson D, Levine PA, Wilkoff BL (1996) Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers. Pacing Clin Electrophysiol 19(6):913–919PubMedCrossRef Gimbel JR, Johnson D, Levine PA, Wilkoff BL (1996) Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers. Pacing Clin Electrophysiol 19(6):913–919PubMedCrossRef
18.
Zurück zum Zitat Nitz WR, Brinker G, Diehl D, Frese G (2005) Specific absorption rate as a poor indicator of magnetic resonance-related implant heating. Invest Radiol 40(12):773–776PubMedCrossRef Nitz WR, Brinker G, Diehl D, Frese G (2005) Specific absorption rate as a poor indicator of magnetic resonance-related implant heating. Invest Radiol 40(12):773–776PubMedCrossRef
19.
Zurück zum Zitat Shellock FG, Cosendai G, Park SM, Nyenhuis JA (2004) Implantable microstimulator: magnetic resonance safety at 1.5 Tesla. Invest Radiol 39(10):591–599PubMedCrossRef Shellock FG, Cosendai G, Park SM, Nyenhuis JA (2004) Implantable microstimulator: magnetic resonance safety at 1.5 Tesla. Invest Radiol 39(10):591–599PubMedCrossRef
20.
Zurück zum Zitat Kuroda K, Oshio K, Chung AH, Hynynen K, Jolesz FA (1997) Temperature mapping using the water proton chemical shift: a chemical shift selective phase mapping method. Magn Reson Med 38(5):845–851PubMedCrossRef Kuroda K, Oshio K, Chung AH, Hynynen K, Jolesz FA (1997) Temperature mapping using the water proton chemical shift: a chemical shift selective phase mapping method. Magn Reson Med 38(5):845–851PubMedCrossRef
21.
Zurück zum Zitat Cady EB, D’Souza PC, Penrice J, Lorek A (1995) The estimation of local brain temperature by in vivo 1H magnetic resonance spectroscopy. Magn Reson Med 33(6):862–867PubMedCrossRef Cady EB, D’Souza PC, Penrice J, Lorek A (1995) The estimation of local brain temperature by in vivo 1H magnetic resonance spectroscopy. Magn Reson Med 33(6):862–867PubMedCrossRef
22.
Zurück zum Zitat Hitzig BM, Perng WC, Burt T, Okunieff P, Johnson DC (1994) 1H-NMR measurement of fractional dissociation of imidazole in intact animals. Am J Physiol 266(3 Pt 2):R1008–R1015PubMed Hitzig BM, Perng WC, Burt T, Okunieff P, Johnson DC (1994) 1H-NMR measurement of fractional dissociation of imidazole in intact animals. Am J Physiol 266(3 Pt 2):R1008–R1015PubMed
23.
Zurück zum Zitat MacFall JR, Prescott DM, Charles HC, Samulski TV (1996) 1H MRI phase thermometry in vivo in canine brain, muscle, and tumor tissue. Med Phys 23(10):1775–1782PubMedCrossRef MacFall JR, Prescott DM, Charles HC, Samulski TV (1996) 1H MRI phase thermometry in vivo in canine brain, muscle, and tumor tissue. Med Phys 23(10):1775–1782PubMedCrossRef
24.
Zurück zum Zitat van den Boogaart A, van Ormondt D, Pijnappel WW, de Beer R, Ala-Korpela M (1994) Removal of the water resonance from1H-magnetic resonance spectra. In: McWhirter JG (ed) Mathematics in signal processing III. Clarendon Press, Oxford, pp 175–195 van den Boogaart A, van Ormondt D, Pijnappel WW, de Beer R, Ala-Korpela M (1994) Removal of the water resonance from1H-magnetic resonance spectra. In: McWhirter JG (ed) Mathematics in signal processing III. Clarendon Press, Oxford, pp 175–195
25.
Zurück zum Zitat Watts AM, Tyler MP, Perry ME, Roberts AH, McGrouther DA (2001) Burn depth and its histological measurement. Burns 27(2):154–160PubMedCrossRef Watts AM, Tyler MP, Perry ME, Roberts AH, McGrouther DA (2001) Burn depth and its histological measurement. Burns 27(2):154–160PubMedCrossRef
26.
Zurück zum Zitat Haller H (2009) Verbrennungstiefe und Ausmaß. In: Kamolz LP, Herndon DN, Jeschke MG (eds) Verbrennungen. Springer, Wien, pp 159–160CrossRef Haller H (2009) Verbrennungstiefe und Ausmaß. In: Kamolz LP, Herndon DN, Jeschke MG (eds) Verbrennungen. Springer, Wien, pp 159–160CrossRef
27.
Zurück zum Zitat Peters RD, Hinks RS, Henkelman RM (1998) Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry. Magn Reson Med 40(3):454–459PubMedCrossRef Peters RD, Hinks RS, Henkelman RM (1998) Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry. Magn Reson Med 40(3):454–459PubMedCrossRef
28.
Zurück zum Zitat Kuroda K, Mulkern RV, Oshio K, Panych LP, Nakai T, Moriya T, Okuda S, Hynynen K, Jolesz FA (2000) Temperature mapping using the water proton chemical shift: self-referenced method with echo-planar spectroscopic imaging. Magn Reson Med 43(2):220–225PubMedCrossRef Kuroda K, Mulkern RV, Oshio K, Panych LP, Nakai T, Moriya T, Okuda S, Hynynen K, Jolesz FA (2000) Temperature mapping using the water proton chemical shift: self-referenced method with echo-planar spectroscopic imaging. Magn Reson Med 43(2):220–225PubMedCrossRef
29.
Zurück zum Zitat Zhu M, Bashir A, Ackerman JJ, Yablonskiy DA (2008) Improved calibration technique for in vivo proton MRS thermometry for brain temperature measurement. Magn Reson Med 60(3):536–541PubMedCrossRef Zhu M, Bashir A, Ackerman JJ, Yablonskiy DA (2008) Improved calibration technique for in vivo proton MRS thermometry for brain temperature measurement. Magn Reson Med 60(3):536–541PubMedCrossRef
30.
Zurück zum Zitat Mulkern RV, Chung AH, Jolesz FA, Hynynen K (1997) Temperature monitoring of ultrasonically heated muscle with RARE chemical shift imaging. Med Phys 24(12):1899–1906PubMedCrossRef Mulkern RV, Chung AH, Jolesz FA, Hynynen K (1997) Temperature monitoring of ultrasonically heated muscle with RARE chemical shift imaging. Med Phys 24(12):1899–1906PubMedCrossRef
31.
Zurück zum Zitat Kuroda K, Suzuki Y, Ishihara Y, Okamoto K (1996) Temperature mapping using water proton chemical shift obtained with 3D-MRSI: feasibility in vivo. Magn Reson Med 35(1):20–29PubMedCrossRef Kuroda K, Suzuki Y, Ishihara Y, Okamoto K (1996) Temperature mapping using water proton chemical shift obtained with 3D-MRSI: feasibility in vivo. Magn Reson Med 35(1):20–29PubMedCrossRef
32.
Zurück zum Zitat Sommer T, Vahlhaus C, Lauck G, von Smekal A, Reinke M, Hofer U, Block W, Traber F, Schneider C, Gieseke J, Jung W, Schild H (2000) MR imaging and cardiac pacemakers: in vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology 215(3):869–879PubMed Sommer T, Vahlhaus C, Lauck G, von Smekal A, Reinke M, Hofer U, Block W, Traber F, Schneider C, Gieseke J, Jung W, Schild H (2000) MR imaging and cardiac pacemakers: in vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology 215(3):869–879PubMed
33.
Zurück zum Zitat Shellock FG, Shellock VJ (1998) Cardiovascular catheters and accessories: ex vivo testing of ferromagnetism, heating, and artifacts associated with MRI. J Magn Reson Imaging 8(6):1338–1342PubMedCrossRef Shellock FG, Shellock VJ (1998) Cardiovascular catheters and accessories: ex vivo testing of ferromagnetism, heating, and artifacts associated with MRI. J Magn Reson Imaging 8(6):1338–1342PubMedCrossRef
34.
Zurück zum Zitat Finelli DA, Rezai AR, Ruggieri PM, Tkach JA, Nyenhuis JA, Hrdlicka G, Sharan A, Gonzalez-Martinez J, Stypulkowski PH, Shellock FG (2002) MR imaging-related heating of deep brain stimulation electrodes: in vitro study. AJNR Am J Neuroradiol 23(10):1795–1802PubMed Finelli DA, Rezai AR, Ruggieri PM, Tkach JA, Nyenhuis JA, Hrdlicka G, Sharan A, Gonzalez-Martinez J, Stypulkowski PH, Shellock FG (2002) MR imaging-related heating of deep brain stimulation electrodes: in vitro study. AJNR Am J Neuroradiol 23(10):1795–1802PubMed
35.
Zurück zum Zitat Mattei E, Triventi M, Calcagnini G, Censi F, Kainz W, Mendoza G, Bassen HI, Bartolini P (2008) Complexity of MRI induced heating on metallic leads: experimental measurements of 374 configurations. Biomed Eng Online 7:11PubMedCrossRef Mattei E, Triventi M, Calcagnini G, Censi F, Kainz W, Mendoza G, Bassen HI, Bartolini P (2008) Complexity of MRI induced heating on metallic leads: experimental measurements of 374 configurations. Biomed Eng Online 7:11PubMedCrossRef
Metadaten
Titel
Compatibility of temporary pacemaker myocardial pacing leads with magnetic resonance imaging: an ex vivo tissue study
verfasst von
Alexander Pfeil
Stefanie Drobnik
Reinhard Rzanny
Anas Aboud
Joachim Böttcher
Peter Schmidt
Christian Ortmann
Gita Mall
Khosro Hekmat
Bernhard Brehm
Juergen Reichenbach
Thomas E. Mayer
Gunter Wolf
Andreas Hansch
Publikationsdatum
01.02.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 2/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9800-y

Weitere Artikel der Ausgabe 2/2012

The International Journal of Cardiovascular Imaging 2/2012 Zur Ausgabe

Schadet Ärger den Gefäßen?

14.05.2024 Arteriosklerose Nachrichten

In einer Studie aus New York wirkte sich Ärger kurzfristig deutlich negativ auf die Endothelfunktion gesunder Probanden aus. Möglicherweise hat dies Einfluss auf die kardiovaskuläre Gesundheit.

Intervallfasten zur Regeneration des Herzmuskels?

14.05.2024 Herzinfarkt Nachrichten

Die Nahrungsaufnahme auf wenige Stunden am Tag zu beschränken, hat möglicherweise einen günstigen Einfluss auf die Prognose nach akutem ST-Hebungsinfarkt. Darauf deutet eine Studie an der Uniklinik in Halle an der Saale hin.

Shunt-Therapie bei Herzinsuffizienz: Kein Anzug, der allen passt

13.05.2024 Chronische Herzinsuffizienz Nachrichten

Die Anlage eines interatrialen Shunts zur Reduktion des linksatrialen Drucks ist ein neuer Therapieansatz bei Herzinsuffizienz. Viele Patienten sprechen darauf an, andere jedoch nicht. 

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.