Abstract

Purpose

To assess whether a fixed contrast media (CM) injection duration improves the magnitude and inter-patient variability in hepatic enhancement over a fixed injection rate.

Methods

Outpatients who underwent portovenous phase abdominal CT (fixed duration, February–November 2018; fixed rate, January–July 2020) with 1.22 mL/kg iohexol 350 were included. Subjects with liver, kidney or heart disease were excluded. The number of subjects and injection protocols were as follows: fixed duration arm, 56 women, 60 men, 35 s injection duration; fixed rate arm, 66 women, 62 men, 3 mL/s injection rate. Liver attenuation measurements were obtained from regions of interest on pre- and post-contrast images. Mean hepatic enhancement (MHE) and MHE normalized to iodine dose (MHE/I) were compared (unpaired t-tests and F-tests).

Results

There was no statistically significant difference in age, weight, body mass index or CM dosing (p > 0.05). Enhancement indices were significantly lower in the fixed rate group as compared to the fixed duration group, as follows: MHE, 50.0 ± 12 vs. 54.8 ± 11 HU (p = 0.001); and MHE/I, 1.53 ± 0.43 vs. 1.66 ± 0.51 HU/g, (p = 0.04). However, there was no significant difference in the variances of MHE (p = 0.51) and MHE/I (p = 0.08).

Conclusion

A fixed CM injection duration yields a greater magnitude in hepatic enhancement indices than a fixed injection rate. Inter-patient variability in hepatic enhancement indices do not significantly differ between the two injection protocols.
Literatur
4.
Zurück zum Zitat Davenport MS, Parikh KR, Mayo-Smith WW, Israel GM, Brown RK, Ellis JH (2017) Effect of Fixed-Volume and Weight-Based Dosing Regimens on the Cost and Volume of Administered Iodinated Contrast Material at Abdominal CT. Journal of the American College of Radiology : JACR 14 (3):359–370. https://doi.org/10.1016/j.jacr.2016.09.001 Davenport MS, Parikh KR, Mayo-Smith WW, Israel GM, Brown RK, Ellis JH (2017) Effect of Fixed-Volume and Weight-Based Dosing Regimens on the Cost and Volume of Administered Iodinated Contrast Material at Abdominal CT. Journal of the American College of Radiology : JACR 14 (3):359–370. https://​doi.​org/​10.​1016/​j.​jacr.​2016.​09.​001
6.
Zurück zum Zitat Awai K, Kanematsu M, Kim T, Ichikawa T, Nakamura Y, Nakamoto A, Yoshioka K, Mochizuki T, Matsunaga N, Yamashita Y (2016) The Optimal Body Size Index with Which to Determine Iodine Dose for Hepatic Dynamic CT: A Prospective Multicenter Study. Radiology 278 (3):773–781. https://doi.org/10.1148/radiol.2015142941 Awai K, Kanematsu M, Kim T, Ichikawa T, Nakamura Y, Nakamoto A, Yoshioka K, Mochizuki T, Matsunaga N, Yamashita Y (2016) The Optimal Body Size Index with Which to Determine Iodine Dose for Hepatic Dynamic CT: A Prospective Multicenter Study. Radiology 278 (3):773–781. https://​doi.​org/​10.​1148/​radiol.​2015142941
7.
Zurück zum Zitat Kondo H, Kanematsu M, Goshima S, Tomita Y, Kim MJ, Moriyama N, Onozuka M, Shiratori Y, Bae KT (2010) Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume. Radiology 254 (1):163–169. https://doi.org/10.1148/radiol.09090369 Kondo H, Kanematsu M, Goshima S, Tomita Y, Kim MJ, Moriyama N, Onozuka M, Shiratori Y, Bae KT (2010) Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume. Radiology 254 (1):163–169. https://​doi.​org/​10.​1148/​radiol.​09090369
8.
Zurück zum Zitat Kondo H, Kanematsu M, Goshima S, Tomita Y, Miyoshi T, Hatcho A, Moriyama N, Onozuka M, Shiratori Y, Bae KT (2008) Abdominal multidetector CT in patients with varying body fat percentages: estimation of optimal contrast material dose. Radiology 249 (3):872–877. https://doi.org/10.1148/radiol.2492080033 Kondo H, Kanematsu M, Goshima S, Tomita Y, Miyoshi T, Hatcho A, Moriyama N, Onozuka M, Shiratori Y, Bae KT (2008) Abdominal multidetector CT in patients with varying body fat percentages: estimation of optimal contrast material dose. Radiology 249 (3):872–877. https://​doi.​org/​10.​1148/​radiol.​2492080033
9.
Zurück zum Zitat Kondo H, Kanematsu M, Goshima S, Watanabe H, Kawada H, Moriyama N, Bae KT (2013) Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight? European radiology 23 (7):1855–1861. https://doi.org/10.1007/s00330-013-2808-z Kondo H, Kanematsu M, Goshima S, Watanabe H, Kawada H, Moriyama N, Bae KT (2013) Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight? European radiology 23 (7):1855–1861. https://​doi.​org/​10.​1007/​s00330-013-2808-z
10.
11.
12.
Zurück zum Zitat Rengo M, Caruso D, De Cecco CN, Lucchesi P, Bellini D, Maceroni MM, Ferrari R, Paolantonio P, Iafrate F, Carbone I, Vecchietti F, Laghi A (2012) High concentration (400 mgI/mL) versus low concentration (320 mgI/mL) iodinated contrast media in multi detector computed tomography of the liver: a randomized, single centre, non-inferiority study. European journal of radiology 81 (11):3096–3101. https://doi.org/10.1016/j.ejrad.2012.05.017 Rengo M, Caruso D, De Cecco CN, Lucchesi P, Bellini D, Maceroni MM, Ferrari R, Paolantonio P, Iafrate F, Carbone I, Vecchietti F, Laghi A (2012) High concentration (400 mgI/mL) versus low concentration (320 mgI/mL) iodinated contrast media in multi detector computed tomography of the liver: a randomized, single centre, non-inferiority study. European journal of radiology 81 (11):3096–3101. https://​doi.​org/​10.​1016/​j.​ejrad.​2012.​05.​017
13.
Zurück zum Zitat Matoba M, Kitadate M, Kondou T, Yokota H, Tonami H (2009) Depiction of hypervascular hepatocellular carcinoma with 64-MDCT: comparison of moderate- and high-concentration contrast material with and without saline flush. AJR American journal of roentgenology 193 (3):738–744. https://doi.org/10.2214/AJR.08.2028 Matoba M, Kitadate M, Kondou T, Yokota H, Tonami H (2009) Depiction of hypervascular hepatocellular carcinoma with 64-MDCT: comparison of moderate- and high-concentration contrast material with and without saline flush. AJR American journal of roentgenology 193 (3):738–744. https://​doi.​org/​10.​2214/​AJR.​08.​2028
14.
Zurück zum Zitat Marin D, Nelson RC, Guerrisi A, Barnhart H, Schindera ST, Passariello R, Catalano C (2011) 64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement. European radiology 21 (9):1938–1947. https://doi.org/10.1007/s00330-011-2139-x Marin D, Nelson RC, Guerrisi A, Barnhart H, Schindera ST, Passariello R, Catalano C (2011) 64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement. European radiology 21 (9):1938–1947. https://​doi.​org/​10.​1007/​s00330-011-2139-x
15.
Zurück zum Zitat Bae KT, Heiken JP (2005) Scan and contrast administration principles of MDCT. European radiology 15 Suppl 5:E46–59 Bae KT, Heiken JP (2005) Scan and contrast administration principles of MDCT. European radiology 15 Suppl 5:E46–59
16.
Zurück zum Zitat Wald C, Russo MW, Heimbach JK, Hussain HK, Pomfret EA, Bruix J (2013) New OPTN/UNOS policy for liver transplant allocation: standardization of liver imaging, diagnosis, classification, and reporting of hepatocellular carcinoma. Radiology 266 (2):376–382. https://doi.org/10.1148/radiol.12121698 Wald C, Russo MW, Heimbach JK, Hussain HK, Pomfret EA, Bruix J (2013) New OPTN/UNOS policy for liver transplant allocation: standardization of liver imaging, diagnosis, classification, and reporting of hepatocellular carcinoma. Radiology 266 (2):376–382. https://​doi.​org/​10.​1148/​radiol.​12121698
17.
Zurück zum Zitat Kambadakone AR, Fung A, Gupta RT, Hope TA, Fowler KJ, Lyshchik A, Ganesan K, Yaghmai V, Guimaraes AR, Sahani DV, Miller FH (2018) LI-RADS technical requirements for CT, MRI, and contrast-enhanced ultrasound. Abdom Radiol (NY) 43 (1):56–74. https://doi.org/10.1007/s00261-017-1325-y Kambadakone AR, Fung A, Gupta RT, Hope TA, Fowler KJ, Lyshchik A, Ganesan K, Yaghmai V, Guimaraes AR, Sahani DV, Miller FH (2018) LI-RADS technical requirements for CT, MRI, and contrast-enhanced ultrasound. Abdom Radiol (NY) 43 (1):56–74. https://​doi.​org/​10.​1007/​s00261-017-1325-y
20.
Zurück zum Zitat Awai K, Hori S (2003) Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT. European radiology 13 (9):2155–2160. https://doi.org/10.1007/s00330-003-1904-x Awai K, Hori S (2003) Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT. European radiology 13 (9):2155–2160. https://​doi.​org/​10.​1007/​s00330-003-1904-x
21.
25.
Zurück zum Zitat Park HJ, Son JH, Kim T-B, Kang MK, Han K, Kim EH, Kim AY, Park SH Relationship between Lower Dose and Injection Speed of Iodinated Contrast Material for CT and Acute Hypersensitivity Reactions: An Observational Study. Radiology 0 (0):190829. https://doi.org/10.1148/radiol.2019190829 Park HJ, Son JH, Kim T-B, Kang MK, Han K, Kim EH, Kim AY, Park SH Relationship between Lower Dose and Injection Speed of Iodinated Contrast Material for CT and Acute Hypersensitivity Reactions: An Observational Study. Radiology 0 (0):190829. https://​doi.​org/​10.​1148/​radiol.​2019190829
Metadaten
Titel
Contrast media injection protocol for portovenous phase abdominal CT: does a fixed injection duration improve hepatic enhancement over a fixed injection rate?
verfasst von
Andreu F. Costa
Kris Peet
Publikationsdatum
02.01.2021
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 6/2021
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-020-02919-3

Weitere Artikel der Ausgabe 6/2021

Abdominal Radiology 6/2021 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.