Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 10/2013

01.10.2013 | Glaucoma

Corneal biomechanics predict the outcome of selective laser trabeculoplasty in medically uncontrolled glaucoma

verfasst von: Christoph Hirneiß, K. Sekura, U. Brandlhuber, A. Kampik, M. Kernt

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 10/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate the predictive value of clinical parameters, including biomechanical properties on the outcome of selective laser trabeculoplasty (SLT) in medically uncontrolled open angle glaucoma (OAG).

Methods

Sixty-eight eyes from 68 patients with OAG and IOP insufficiently regulated by topical medications were enrolled. Patients’ follow-up occurred 6 and 12 months after the procedure. The recorded parameters intraocular pressure (IOP), angle characteristics, central corneal thickness (CCT) and biomechanical properties of the eyes, including corneal hysteresis CH and corneal resistance factor CRF measured with the Ocular Responses Analyzer (ORA, Reichert Ophthalmic Instruments) were tested on their predictive value of SLT-induced IOP lowering effect using correlation analyses and regression models.

Results

Mean IOP reduction 12 months after SLT was 4.2 ± 5.7 mmHg (23.2 %, from baseline 18.1 ± 5.2 mmHg). The preoperative IOP correlated significantly with IOP reduction (maximum Spearman’s correlation r = 0.75, p < 0.001). In linear regression analysis, the corneal biomechanical properties (CH and CRF) together with the baseline IOP revealed good modelling for the IOP lowering effect of SLT (R2 = 0.64, respectively).

Conclusions

In addition to the baseline IOP biomechanical properties (CH and CRF) are significant predictors of SLT induced IOP lowering effect in medically uncontrolled OAG.
Literatur
1.
Zurück zum Zitat Quigley HA, Broman AT (2006) The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol 90:262–267PubMedCrossRef Quigley HA, Broman AT (2006) The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol 90:262–267PubMedCrossRef
2.
Zurück zum Zitat Krasnov M (1972) Laser puncture of the anterior chamber angle in glaucoma (a preliminary report) [in Russian]. Vestn Oftalmol 3:27–31. Krasnov M (1972) Laser puncture of the anterior chamber angle in glaucoma (a preliminary report) [in Russian]. Vestn Oftalmol 3:27–31.
3.
Zurück zum Zitat Latina MA, Park C (1995) Selective targeting of trabecular meshwork cells: in vitro studies of pulsed and CW laser interactions. Exp Eye Res 60:359–371PubMedCrossRef Latina MA, Park C (1995) Selective targeting of trabecular meshwork cells: in vitro studies of pulsed and CW laser interactions. Exp Eye Res 60:359–371PubMedCrossRef
4.
Zurück zum Zitat Bovell AM, Damji KF, Hodge WG, Rock WJ, Buhrmann RR, Pan YI (2011) Long term effects on the lowering of intraocular pressure: selective laser or argon laser trabeculoplasty? Can J Ophthalmol 46:408–413PubMed Bovell AM, Damji KF, Hodge WG, Rock WJ, Buhrmann RR, Pan YI (2011) Long term effects on the lowering of intraocular pressure: selective laser or argon laser trabeculoplasty? Can J Ophthalmol 46:408–413PubMed
5.
Zurück zum Zitat Liu Y, Birt CM (2012) Argon versus selective laser trabeculoplasty in younger patients: 2-year results. J Glaucoma 21:112–115PubMed Liu Y, Birt CM (2012) Argon versus selective laser trabeculoplasty in younger patients: 2-year results. J Glaucoma 21:112–115PubMed
6.
Zurück zum Zitat Kramer TR, Noecker RJ (2001) Comparison of the morphologic changes after selective laser trabeculoplasty and argon laser trabeculoplasty in human eye bank eyes. Ophthalmology 10:773–779CrossRef Kramer TR, Noecker RJ (2001) Comparison of the morphologic changes after selective laser trabeculoplasty and argon laser trabeculoplasty in human eye bank eyes. Ophthalmology 10:773–779CrossRef
7.
Zurück zum Zitat Samples JR, Singh K, Lin SC, Francis BA, Hodapp E, Jampel HD, Smith SD (2011) Laser trabeculoplasty for open-angle Glaucoma A report by the american academy of ophthalmology. Ophthalmology 118:2296–2302PubMedCrossRef Samples JR, Singh K, Lin SC, Francis BA, Hodapp E, Jampel HD, Smith SD (2011) Laser trabeculoplasty for open-angle Glaucoma A report by the american academy of ophthalmology. Ophthalmology 118:2296–2302PubMedCrossRef
8.
Zurück zum Zitat Katz LJ, Steinmann WC, Kabir A, Molineaux J, Wizov SS, Marcellino G (2012) Selective laser trabeculoplasty versus medical therapy as initial treatment of glaucoma: a prospective, randomized trial. J Glaucoma 21:460–468PubMedCrossRef Katz LJ, Steinmann WC, Kabir A, Molineaux J, Wizov SS, Marcellino G (2012) Selective laser trabeculoplasty versus medical therapy as initial treatment of glaucoma: a prospective, randomized trial. J Glaucoma 21:460–468PubMedCrossRef
9.
Zurück zum Zitat Ayala M, Chen E (2011) Predictive factors of success in selective laser trabeculoplasty (SLT) treatment. Clin Ophthalmol 5:573–576PubMedCrossRef Ayala M, Chen E (2011) Predictive factors of success in selective laser trabeculoplasty (SLT) treatment. Clin Ophthalmol 5:573–576PubMedCrossRef
10.
Zurück zum Zitat Tzimis V, Tze L, Ganesh J, Muhsen S, Kiss A, Kranemann C, Birt CM (2011) Laser trabeculoplasty: an investigation into factors that might influence outcomes. Can J Ophthalmol 46:305–309PubMed Tzimis V, Tze L, Ganesh J, Muhsen S, Kiss A, Kranemann C, Birt CM (2011) Laser trabeculoplasty: an investigation into factors that might influence outcomes. Can J Ophthalmol 46:305–309PubMed
11.
Zurück zum Zitat Bruen R, Lesk MR, Harasymowycz P (2012) Baseline factors predictive of SLT response: a prospective study. J Ophthalmol 2012:642869PubMed Bruen R, Lesk MR, Harasymowycz P (2012) Baseline factors predictive of SLT response: a prospective study. J Ophthalmol 2012:642869PubMed
12.
Zurück zum Zitat De Moraes CV, Hill V, Tello C, Liebmann JM, Ritch R (2012) Lower corneal hysteresis is associated with more rapid glaucomatous visual field progression. J Glaucoma 21:209–213PubMedCrossRef De Moraes CV, Hill V, Tello C, Liebmann JM, Ritch R (2012) Lower corneal hysteresis is associated with more rapid glaucomatous visual field progression. J Glaucoma 21:209–213PubMedCrossRef
13.
Zurück zum Zitat Abitbol O, Bouden J, Doan S, Hoang-Xuan T, Gatinel D (2010) Corneal hysteresis measured with the Ocular Response Analyzer in normal and glaucomatous eyes. Acta Ophthalmol 88:116–119PubMedCrossRef Abitbol O, Bouden J, Doan S, Hoang-Xuan T, Gatinel D (2010) Corneal hysteresis measured with the Ocular Response Analyzer in normal and glaucomatous eyes. Acta Ophthalmol 88:116–119PubMedCrossRef
14.
Zurück zum Zitat Spaeth GL (1971) The normal development of the human anterior chamber angle: a new system of descriptive grading. Trans Ophthalmol Soc U K 91:709–739PubMed Spaeth GL (1971) The normal development of the human anterior chamber angle: a new system of descriptive grading. Trans Ophthalmol Soc U K 91:709–739PubMed
15.
Zurück zum Zitat Luce DA (2005) Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31:156–162PubMedCrossRef Luce DA (2005) Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31:156–162PubMedCrossRef
16.
Zurück zum Zitat Sullivan-Mee M, Billingsley SC, Patel AD, Halverson KD, Alldredge BR, Qualls C (2008) Ocular Response Analyzer in subjects with and without glaucoma. Optom Vis Sci 85:463–470PubMedCrossRef Sullivan-Mee M, Billingsley SC, Patel AD, Halverson KD, Alldredge BR, Qualls C (2008) Ocular Response Analyzer in subjects with and without glaucoma. Optom Vis Sci 85:463–470PubMedCrossRef
17.
Zurück zum Zitat Kirwan C, O’Malley D, O’Keefe M (2008) Corneal hysteresis and corneal resistance factor in keratoectasia: findings using the Reichert ocular response analyzer. Ophthalmologica 222:334–337PubMedCrossRef Kirwan C, O’Malley D, O’Keefe M (2008) Corneal hysteresis and corneal resistance factor in keratoectasia: findings using the Reichert ocular response analyzer. Ophthalmologica 222:334–337PubMedCrossRef
18.
Zurück zum Zitat Carbonaro F, Andrew T, Mackey DA, Spector TD, Hammond CJ (2008) The heritability of corneal hysteresis and ocular pulse amplitude: a twin study. Ophthalmology 115:1545–1549PubMedCrossRef Carbonaro F, Andrew T, Mackey DA, Spector TD, Hammond CJ (2008) The heritability of corneal hysteresis and ocular pulse amplitude: a twin study. Ophthalmology 115:1545–1549PubMedCrossRef
19.
Zurück zum Zitat Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I (2007) Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci 48:3026–3031PubMedCrossRef Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I (2007) Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci 48:3026–3031PubMedCrossRef
20.
Zurück zum Zitat Ortiz D, Pinero D, Shabayek MH, Arnalich-Montiel F, Alio JL (2007) Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg 33:1371–1375PubMedCrossRef Ortiz D, Pinero D, Shabayek MH, Arnalich-Montiel F, Alio JL (2007) Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg 33:1371–1375PubMedCrossRef
21.
Zurück zum Zitat Kirwan C, O’Keefe M, Lanigan B (2006) Corneal hysteresis and intraocular pressure measurement in children using the reichert ocular response analyzer. Am J Ophthalmol 142:990–992PubMedCrossRef Kirwan C, O’Keefe M, Lanigan B (2006) Corneal hysteresis and intraocular pressure measurement in children using the reichert ocular response analyzer. Am J Ophthalmol 142:990–992PubMedCrossRef
22.
Zurück zum Zitat Sporl E, Terai N, Haustein M, Bohm AG, Raiskup-Wolf F, Pillunat LE (2009) Biomechanical condition of the cornea as a new indicator for pathological and structural changes. Ophthalmologe 106:512–520PubMedCrossRef Sporl E, Terai N, Haustein M, Bohm AG, Raiskup-Wolf F, Pillunat LE (2009) Biomechanical condition of the cornea as a new indicator for pathological and structural changes. Ophthalmologe 106:512–520PubMedCrossRef
23.
Zurück zum Zitat Hirneiss C, Neubauer AS, Yu A, Kampik A, Kernt M (2011) Corneal biomechanics measured with the ocular response analyser in patients with unilateral open-angle glaucoma. Acta Ophthalmol 2011(89):e189–e192CrossRef Hirneiss C, Neubauer AS, Yu A, Kampik A, Kernt M (2011) Corneal biomechanics measured with the ocular response analyser in patients with unilateral open-angle glaucoma. Acta Ophthalmol 2011(89):e189–e192CrossRef
24.
Zurück zum Zitat Prasad N, Murthy S, Dagianis JJ, Latina MA (2009) A comparison of the intervisit intraocular pressure fluctuation after 180 and 360 degrees of selective laser trabeculoplasty (SLT) as a primary therapy in primary open angle glaucoma and ocular hypertension. J Glaucoma 18:157–160PubMedCrossRef Prasad N, Murthy S, Dagianis JJ, Latina MA (2009) A comparison of the intervisit intraocular pressure fluctuation after 180 and 360 degrees of selective laser trabeculoplasty (SLT) as a primary therapy in primary open angle glaucoma and ocular hypertension. J Glaucoma 18:157–160PubMedCrossRef
25.
Zurück zum Zitat Nagar M, Luhishi E, Shah N (2009) Intraocular pressure control and fluctuation: the effect of treatment with selective laser trabeculoplasty. Br J Ophthalmol 93:497–501PubMedCrossRef Nagar M, Luhishi E, Shah N (2009) Intraocular pressure control and fluctuation: the effect of treatment with selective laser trabeculoplasty. Br J Ophthalmol 93:497–501PubMedCrossRef
26.
Zurück zum Zitat Hodge WG, Damji KF, Rock W, Buhrmann R, Bovell AM, Pan Y (2005) Baseline IOP predicts selective laser trabeculoplasty success at 1 year post-treatment: results from a randomised clinical trial. Br J Ophthalmol 89:1157–1160PubMedCrossRef Hodge WG, Damji KF, Rock W, Buhrmann R, Bovell AM, Pan Y (2005) Baseline IOP predicts selective laser trabeculoplasty success at 1 year post-treatment: results from a randomised clinical trial. Br J Ophthalmol 89:1157–1160PubMedCrossRef
27.
Zurück zum Zitat Koucheki B, Hashemi H (2012) Selective laser trabeculoplasty in the treatment of open-angle glaucoma. J Glaucoma 21:65–70PubMedCrossRef Koucheki B, Hashemi H (2012) Selective laser trabeculoplasty in the treatment of open-angle glaucoma. J Glaucoma 21:65–70PubMedCrossRef
28.
Zurück zum Zitat Shazly TA, Latina MA, Dagianis JJ, Chitturi S (2012) Effect of central corneal thickness on the long-term outcome of selective laser trabeculoplasty as primary treatment for ocular hypertension. Cornea 31:883–886PubMedCrossRef Shazly TA, Latina MA, Dagianis JJ, Chitturi S (2012) Effect of central corneal thickness on the long-term outcome of selective laser trabeculoplasty as primary treatment for ocular hypertension. Cornea 31:883–886PubMedCrossRef
29.
Zurück zum Zitat Martow E, Hutnik CM, Mao A (2011) SLT and adjunctive medical therapy: a prediction rule analysis. J Glaucoma 20:266–270PubMedCrossRef Martow E, Hutnik CM, Mao A (2011) SLT and adjunctive medical therapy: a prediction rule analysis. J Glaucoma 20:266–270PubMedCrossRef
30.
Zurück zum Zitat Hirn C, Zweifel SA, Toteberg-Harms M, Funk J (2012) Effectiveness of selective laser trabeculoplasty in patients with insufficient control of intraocular pressure despite maximum tolerated medical therapy. Ophthalmologe 109:683–690PubMedCrossRef Hirn C, Zweifel SA, Toteberg-Harms M, Funk J (2012) Effectiveness of selective laser trabeculoplasty in patients with insufficient control of intraocular pressure despite maximum tolerated medical therapy. Ophthalmologe 109:683–690PubMedCrossRef
31.
Zurück zum Zitat Wells AP, Garway-Heath DF, Poostchi A, Wong T, Chan KC, Sachdev N (2008) Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients. Invest Ophthalmol Vis Sci 49:3262–3268PubMedCrossRef Wells AP, Garway-Heath DF, Poostchi A, Wong T, Chan KC, Sachdev N (2008) Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients. Invest Ophthalmol Vis Sci 49:3262–3268PubMedCrossRef
32.
Zurück zum Zitat Last JA, Pan T, Ding Y, Reilly CM, Keller K, Acott TS, Fautsch MP, Murphy CJ, Russell P (2011) Elastic modulus determination of normal and glaucomatous human trabecular meshwork. Invest Ophthalmol Vis Sci 52:2147–2152PubMedCrossRef Last JA, Pan T, Ding Y, Reilly CM, Keller K, Acott TS, Fautsch MP, Murphy CJ, Russell P (2011) Elastic modulus determination of normal and glaucomatous human trabecular meshwork. Invest Ophthalmol Vis Sci 52:2147–2152PubMedCrossRef
33.
Zurück zum Zitat Liu J, Roberts CJ (2005) Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg 31:146–155PubMedCrossRef Liu J, Roberts CJ (2005) Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg 31:146–155PubMedCrossRef
Metadaten
Titel
Corneal biomechanics predict the outcome of selective laser trabeculoplasty in medically uncontrolled glaucoma
verfasst von
Christoph Hirneiß
K. Sekura
U. Brandlhuber
A. Kampik
M. Kernt
Publikationsdatum
01.10.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 10/2013
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-013-2416-2

Weitere Artikel der Ausgabe 10/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 10/2013 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.