Skip to main content
Erschienen in: Journal of Digital Imaging 5/2019

28.02.2019

CT-Based 3D Printing of the Glenoid Prior to Shoulder Arthroplasty: Bony Morphology and Model Evaluation

verfasst von: Kenneth C. Wang, Anja Jones, Shivkumar Kambhampati, Mohit N. Gilotra, Peter C. Liacouras, Satre Stuelke, Brian Shiu, Natalie Leong, S. Ashfaq Hasan, Eliot L. Siegel

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 5/2019

Einloggen, um Zugang zu erhalten

Abstract

To demonstrate the 3D printed appearance of glenoid morphologies relevant to shoulder replacement surgery and to evaluate the benefits of printed models of the glenoid with regard to surgical planning. A retrospective review of patients referred for shoulder CT was performed, leading to a cohort of nine patients without arthroplasty hardware and exhibiting glenoid changes relevant to shoulder arthroplasty planning. Thin slice CT images were used to create both humerus-subtracted volume renderings of the glenoid, as well as 3D surface models of the glenoid, and 11 printed models were created. Volume renderings, surface models, and printed models were reviewed by a musculoskeletal radiologist for accuracy. Four fellowship-trained orthopaedic surgeons specializing in shoulder surgery reviewed each case individually as follows: First, the source CT images were reviewed, and a score for the clarity of the bony morphologies relevant to shoulder arthroplasty surgery was given. The volume rendering was reviewed, and the clarity was again scored. Finally, the printed model was reviewed, and the clarity again scored. Each printed model was also scored for morphologic complexity, expected usefulness of the printed model, and physical properties of the model. Mann–Whitney–Wilcoxon signed rank tests of the clarity scores were calculated, and the Spearman’s ρ correlation coefficient between complexity and usefulness scores was computed. Printed models demonstrated a range of glenoid bony changes including osteophytes, glenoid bone loss, retroversion, and biconcavity. Surgeons rated the glenoid morphology as more clear after review of humerus-subtracted volume rendering, compared with review of the source CT images (p = 0.00903). Clarity was also better with 3D printed models compared to CT (p = 0.00903) and better with 3D printed models compared to humerus-subtracted volume rendering (p = 0. 00879). The expected usefulness of printed models demonstrated a positive correlation with morphologic complexity, with Spearman’s ρ 0.73 (p = 0.0108). 3D printing of the glenoid based on pre-operative CT provides a physical representation of patient anatomy. Printed models enabled shoulder surgeons to appreciate glenoid bony morphology more clearly compared to review of CT images or humerus-subtracted volume renderings. These models were more useful as glenoid complexity increased.
Literatur
1.
Zurück zum Zitat Horton K, Fishman E: Pictorial essay: Multidetector CT angiography of pancreatic carcinoma: Part i, evaluation of arterial involvement. Am J Roentgenol. 178:827–831, 2002CrossRef Horton K, Fishman E: Pictorial essay: Multidetector CT angiography of pancreatic carcinoma: Part i, evaluation of arterial involvement. Am J Roentgenol. 178:827–831, 2002CrossRef
2.
Zurück zum Zitat Beebe H, Kritpracha B: Computed tomography scanning for endograft planning: Evolving toward three-dimensional, single source imaging. Sem Vasc Surg. 17:126–134, 2004CrossRef Beebe H, Kritpracha B: Computed tomography scanning for endograft planning: Evolving toward three-dimensional, single source imaging. Sem Vasc Surg. 17:126–134, 2004CrossRef
3.
Zurück zum Zitat Radtke A, Sotiropoulos G, Molmenti E et al.: Computer-assisted surgery planning for complex liver resections. When it is helpful? A single-center experience over an 8-year period. Ann Surg. 252:876–883, 2010CrossRefPubMed Radtke A, Sotiropoulos G, Molmenti E et al.: Computer-assisted surgery planning for complex liver resections. When it is helpful? A single-center experience over an 8-year period. Ann Surg. 252:876–883, 2010CrossRefPubMed
4.
Zurück zum Zitat Schienfeld M, Dym A, Spektor M, Avery L, Dym R, Amanatullah D: Acetabular fractures: What radiologists should know and how 3D CT can aid classification. RadioGraphics. 35:555–577, 2015CrossRef Schienfeld M, Dym A, Spektor M, Avery L, Dym R, Amanatullah D: Acetabular fractures: What radiologists should know and how 3D CT can aid classification. RadioGraphics. 35:555–577, 2015CrossRef
5.
Zurück zum Zitat Kim M, Hangsen A, Wink O, Quaife R, Carroll J: Rapid prototyping: A new tool in understanding and treating structural heart disease. Circulation. 117:2388–2394, 2008CrossRefPubMed Kim M, Hangsen A, Wink O, Quaife R, Carroll J: Rapid prototyping: A new tool in understanding and treating structural heart disease. Circulation. 117:2388–2394, 2008CrossRefPubMed
6.
Zurück zum Zitat Bibb R, Eggbeer D, Evans P: Rapid prototyping technologies in soft tissue facial prosthetics: Current state of the art. Rapid Prototyping Journal. 16:130–137, 2010CrossRef Bibb R, Eggbeer D, Evans P: Rapid prototyping technologies in soft tissue facial prosthetics: Current state of the art. Rapid Prototyping Journal. 16:130–137, 2010CrossRef
7.
Zurück zum Zitat Mitsouras D, Liacouras P, Imanzadeh A, Giannopoulos AA, Cai T, Kumamaru KK, George E, Wake N, Caterson EJ, Pomahac B, Ho VB, Grant GT, Rybicki FJ: Medical 3D printing for the radiologist. RadioGraphics. 35:1965–1988, 2015CrossRefPubMedPubMedCentral Mitsouras D, Liacouras P, Imanzadeh A, Giannopoulos AA, Cai T, Kumamaru KK, George E, Wake N, Caterson EJ, Pomahac B, Ho VB, Grant GT, Rybicki FJ: Medical 3D printing for the radiologist. RadioGraphics. 35:1965–1988, 2015CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Wake N, Rude T, Kang S et al.: 3D printed renal cancer models derived from MRI data: Application in pre-surgical planning. Abdom Radiol. 42:1501–1509, 2017CrossRef Wake N, Rude T, Kang S et al.: 3D printed renal cancer models derived from MRI data: Application in pre-surgical planning. Abdom Radiol. 42:1501–1509, 2017CrossRef
9.
Zurück zum Zitat Norris T, Iannotti J: Functional outcome after shoulder arthroplasty for primary osteoarthritis: A multicenter study. J Shoulder Elbow Surg. 11:130–135, 2002CrossRefPubMed Norris T, Iannotti J: Functional outcome after shoulder arthroplasty for primary osteoarthritis: A multicenter study. J Shoulder Elbow Surg. 11:130–135, 2002CrossRefPubMed
10.
Zurück zum Zitat Strauss E, Roche C, Flurin P, Wright T, Zuckerman J: The glenoid in shoulder arthroplasty. J Shoulder Elbow Surg. 18:819–833, 2009CrossRefPubMed Strauss E, Roche C, Flurin P, Wright T, Zuckerman J: The glenoid in shoulder arthroplasty. J Shoulder Elbow Surg. 18:819–833, 2009CrossRefPubMed
11.
Zurück zum Zitat Matsen, III F, Bicknell R, Lippitt S: Shoulder arthroplasty: The socket perspective. J Shoulder Elbow Surg. 16:241S–247S, 2007CrossRef Matsen, III F, Bicknell R, Lippitt S: Shoulder arthroplasty: The socket perspective. J Shoulder Elbow Surg. 16:241S–247S, 2007CrossRef
12.
Zurück zum Zitat Boileau P, Sinnerton R, Chuinard C, Walch G: Arthroplasty of the shoulder. J Bone Joint Surg. 88:562–575, 2006CrossRef Boileau P, Sinnerton R, Chuinard C, Walch G: Arthroplasty of the shoulder. J Bone Joint Surg. 88:562–575, 2006CrossRef
13.
Zurück zum Zitat Matsen, III F: The ream and run: Not for every patient, every surgeon or every problem. International Orthopaedics. 39:255–261, 2015CrossRefPubMed Matsen, III F: The ream and run: Not for every patient, every surgeon or every problem. International Orthopaedics. 39:255–261, 2015CrossRefPubMed
14.
Zurück zum Zitat Edwards T: CORR insights: Can the ream and run procedure improve glenohumeral relationships and function shoulders with the arthritic triad? Clin Orthop Relat Res. 473:2097–2098, 2015CrossRefPubMedPubMedCentral Edwards T: CORR insights: Can the ream and run procedure improve glenohumeral relationships and function shoulders with the arthritic triad? Clin Orthop Relat Res. 473:2097–2098, 2015CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Frankle M, Siegal S, Pupello D, Saleem A, Mighell M, Vasey M: The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients. J Bone Joint Surg. 87:1697–1705, 2005PubMed Frankle M, Siegal S, Pupello D, Saleem A, Mighell M, Vasey M: The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients. J Bone Joint Surg. 87:1697–1705, 2005PubMed
16.
Zurück zum Zitat Boileau P, Watkinson D, Hatzidakis A, Balg F. Grammont reverse prosthesis: Design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14:147S–161S, S147, S161. Boileau P, Watkinson D, Hatzidakis A, Balg F. Grammont reverse prosthesis: Design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14:147S–161S, S147, S161.
17.
Zurück zum Zitat Roberts C, Ekelund A, Renfree K, Liu P, Chew F: Radiologic assessment of reverse shoulder arthroplasty. RadioGraphics. 27:223–235, 2007CrossRefPubMed Roberts C, Ekelund A, Renfree K, Liu P, Chew F: Radiologic assessment of reverse shoulder arthroplasty. RadioGraphics. 27:223–235, 2007CrossRefPubMed
18.
Zurück zum Zitat Farshad M, Gerber C: Reverse total shoulder arthroplasty—From the most to the least common complication. International Orthopaedics. 34:1075–1082, 2010CrossRefPubMedPubMedCentral Farshad M, Gerber C: Reverse total shoulder arthroplasty—From the most to the least common complication. International Orthopaedics. 34:1075–1082, 2010CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Thompson T, Greenspoon J, Hanypsiak B, Lederman E: Reverse total shoulder arthroplasty: A comprehensive review of biomechanics, surgical technique, and potential complications. Curr Orthop Pract. 25:580–588, 2014CrossRef Thompson T, Greenspoon J, Hanypsiak B, Lederman E: Reverse total shoulder arthroplasty: A comprehensive review of biomechanics, surgical technique, and potential complications. Curr Orthop Pract. 25:580–588, 2014CrossRef
20.
Zurück zum Zitat Simon P, Gupta A, Pappou I, Hussey MM, Santoni BG, Inoue N, Frankle MA: Glenoid subchondral bone density distribution in male total shoulder arthroplasty subjects with eccentric and concentric wear. J Shoulder Elbow Surg. 24:416–424, 2015CrossRefPubMed Simon P, Gupta A, Pappou I, Hussey MM, Santoni BG, Inoue N, Frankle MA: Glenoid subchondral bone density distribution in male total shoulder arthroplasty subjects with eccentric and concentric wear. J Shoulder Elbow Surg. 24:416–424, 2015CrossRefPubMed
21.
Zurück zum Zitat Knowles N, Athwal G, Keener J, Ferreira L: Regional bone density variations in osteoarthritic glenoids: A comparison of symmetric to asymmetric (type B2) erosion patterns. J Shoulder Elbow Surg 24:425–432, 2015CrossRefPubMed Knowles N, Athwal G, Keener J, Ferreira L: Regional bone density variations in osteoarthritic glenoids: A comparison of symmetric to asymmetric (type B2) erosion patterns. J Shoulder Elbow Surg 24:425–432, 2015CrossRefPubMed
22.
Zurück zum Zitat Scalise J, Codsi M, Bryan J, Iannotti J: The three-dimensional glenoid vault model can estimate normal glenoid version in osteoarthritis. J Shoulder Elbow Surg. 17:487–491, 2008CrossRefPubMed Scalise J, Codsi M, Bryan J, Iannotti J: The three-dimensional glenoid vault model can estimate normal glenoid version in osteoarthritis. J Shoulder Elbow Surg. 17:487–491, 2008CrossRefPubMed
23.
Zurück zum Zitat Friedman R, Hawthorne K, Genez B: The use of computerized tomography in the measurement of glenoid version. J Bone Joint Surg. 74:1032–1037, 1992CrossRefPubMed Friedman R, Hawthorne K, Genez B: The use of computerized tomography in the measurement of glenoid version. J Bone Joint Surg. 74:1032–1037, 1992CrossRefPubMed
24.
Zurück zum Zitat Churchill R, Brems J, Kotschi H: Glenoid size, inclination, and version: An anatomic study. J Shoulder Elbow Surg. 10:327–332, 2001CrossRefPubMed Churchill R, Brems J, Kotschi H: Glenoid size, inclination, and version: An anatomic study. J Shoulder Elbow Surg. 10:327–332, 2001CrossRefPubMed
25.
Zurück zum Zitat Inui H, Sugamoto K, Miyamoto T, Machida A, Hashimoto J, Nobuhara K: Evaluation of the three-dimensional glenoid structure using MRI. J Anat. 199:323–328, 2001CrossRefPubMedPubMedCentral Inui H, Sugamoto K, Miyamoto T, Machida A, Hashimoto J, Nobuhara K: Evaluation of the three-dimensional glenoid structure using MRI. J Anat. 199:323–328, 2001CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Steinmann S, Cofield R: Bone grafting for glenoid deficiency in total shoulder replacement. J Shoulder Elbow Surg. 9:361–367, 2000CrossRefPubMed Steinmann S, Cofield R: Bone grafting for glenoid deficiency in total shoulder replacement. J Shoulder Elbow Surg. 9:361–367, 2000CrossRefPubMed
28.
Zurück zum Zitat Friedman T, Michalski M, Goodman T, Brown J: 3D printing from diagnostic images: A radiologist’s primer with an emphasis on musculoskeletal imaging—Putting the 3D printing of pathology into the hands of every physician. Skeletal Radiol. 45:307–321, 2016CrossRefPubMed Friedman T, Michalski M, Goodman T, Brown J: 3D printing from diagnostic images: A radiologist’s primer with an emphasis on musculoskeletal imaging—Putting the 3D printing of pathology into the hands of every physician. Skeletal Radiol. 45:307–321, 2016CrossRefPubMed
29.
Zurück zum Zitat Riesenkampff E, Rietdorf U, Wolf I, Schnackenburg B, Ewert P, Huebler M, Alexi-Meskishvili V, Anderson RH, Engel N, Meinzer HP, Hetzer R, Berger F, Kuehne T: The practical clinical value of three-dimensional models of complex congenitally malformed hearts. J Thoracic Cardiovasc Surg. 138:571–580, 2009CrossRef Riesenkampff E, Rietdorf U, Wolf I, Schnackenburg B, Ewert P, Huebler M, Alexi-Meskishvili V, Anderson RH, Engel N, Meinzer HP, Hetzer R, Berger F, Kuehne T: The practical clinical value of three-dimensional models of complex congenitally malformed hearts. J Thoracic Cardiovasc Surg. 138:571–580, 2009CrossRef
30.
Zurück zum Zitat Matsumoto J, Morris J, Foley T et al.: Three-dimensional physical modeling: Application and experience at mayo clinic. RadioGraphics. 35:1989–2006, 2015CrossRefPubMed Matsumoto J, Morris J, Foley T et al.: Three-dimensional physical modeling: Application and experience at mayo clinic. RadioGraphics. 35:1989–2006, 2015CrossRefPubMed
31.
Zurück zum Zitat Rose A, Webster C, Harryson O, Formeister E, Rawal R, Iseli C: Pre-operative simulation of pediatric mastoid surgery with 3D-printed temporal bone models. Intl J Ped Otorhinolaryngology. 70:740–744, 2015CrossRef Rose A, Webster C, Harryson O, Formeister E, Rawal R, Iseli C: Pre-operative simulation of pediatric mastoid surgery with 3D-printed temporal bone models. Intl J Ped Otorhinolaryngology. 70:740–744, 2015CrossRef
32.
Zurück zum Zitat Gauci M, Boileau P, Baba M, Chaoui J, Walch G: Patient-specific glenoid guides provide accuracy and reproducibility in total shoulder arthroplasty. Bone Joint J. 98-B:1080–1085, 2016CrossRefPubMed Gauci M, Boileau P, Baba M, Chaoui J, Walch G: Patient-specific glenoid guides provide accuracy and reproducibility in total shoulder arthroplasty. Bone Joint J. 98-B:1080–1085, 2016CrossRefPubMed
33.
Zurück zum Zitat Podolsky D, Martin A, Whyne C, Massicotte E, Hardisty M, Ginsberg H: Exploring the role of 3-dimensional simulation in surgical training: Feedback from a pilot study. J Spinal Disord Tech. 23:e70–e74, 2010CrossRefPubMed Podolsky D, Martin A, Whyne C, Massicotte E, Hardisty M, Ginsberg H: Exploring the role of 3-dimensional simulation in surgical training: Feedback from a pilot study. J Spinal Disord Tech. 23:e70–e74, 2010CrossRefPubMed
34.
Zurück zum Zitat Waran V, Narayanan V, Karuppiah R, Owen S, Aziz T: Utility of multimaterial 3D printers in creating models with pathologica entities to enhance the training experience of neurosurgeons. J Neurosurg. 120:489–492, 2014CrossRefPubMed Waran V, Narayanan V, Karuppiah R, Owen S, Aziz T: Utility of multimaterial 3D printers in creating models with pathologica entities to enhance the training experience of neurosurgeons. J Neurosurg. 120:489–492, 2014CrossRefPubMed
35.
Zurück zum Zitat Waran V, Narayanan V, Karuppiah R, Pancharatnam D, Chandran H, Raman R, Rahman ZAA, Owen SLF, Aziz TZ: Injecting realism in surgical training—Initial simulation experience with custom 3D models. J Surg Edu. 71:193–197, 2014CrossRef Waran V, Narayanan V, Karuppiah R, Pancharatnam D, Chandran H, Raman R, Rahman ZAA, Owen SLF, Aziz TZ: Injecting realism in surgical training—Initial simulation experience with custom 3D models. J Surg Edu. 71:193–197, 2014CrossRef
36.
Zurück zum Zitat Bader C, Kolb D, Weaver JC, Sharma S, Hosny A, Costa J, Oxman N: Making data matter: Voxel printing for the digital fabrication of data across scales and domains. Sci Adv. 4:eaas8652, 2018CrossRefPubMedPubMedCentral Bader C, Kolb D, Weaver JC, Sharma S, Hosny A, Costa J, Oxman N: Making data matter: Voxel printing for the digital fabrication of data across scales and domains. Sci Adv. 4:eaas8652, 2018CrossRefPubMedPubMedCentral
Metadaten
Titel
CT-Based 3D Printing of the Glenoid Prior to Shoulder Arthroplasty: Bony Morphology and Model Evaluation
verfasst von
Kenneth C. Wang
Anja Jones
Shivkumar Kambhampati
Mohit N. Gilotra
Peter C. Liacouras
Satre Stuelke
Brian Shiu
Natalie Leong
S. Ashfaq Hasan
Eliot L. Siegel
Publikationsdatum
28.02.2019
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 5/2019
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-019-00177-4

Weitere Artikel der Ausgabe 5/2019

Journal of Digital Imaging 5/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.