Skip to main content
Erschienen in: Journal of Cardiothoracic Surgery 1/2020

Open Access 01.12.2020 | Research article

Development of an effective method utilizing fibrin glue to repair pleural defects in an ex-vivo pig model

verfasst von: Nobuyuki Kondo, Yoshitaka Takegawa, Masaki Hashimoto, Seiji Matsumoto, Shiro Oka, Seiki Hasegawa

Erschienen in: Journal of Cardiothoracic Surgery | Ausgabe 1/2020

Abstract

Background

The present study aimed to use an ex-vivo model to investigate whether a new method involving the use of fibrin glue and a polyglycolic acid (PGA) sheet under ventilation enhances the sealing effect after repair of the pleural defect.

Methods

Ex-vivo pig lungs were used in this study. We investigated the maximum pressure tolerance of pleural defects repaired using three methods: 1, directly spraying fibrin glue over a PGA sheet; 2, spreading fibrinogen on the site then sealing with a PGA sheet and spraying with fibrin glue; and 3, spreading fibrinogen while maintaining ventilation then sealing with a PGA sheet and spraying with fibrin glue.

Results

The maximum tolerable pressures were as follows (mean ± standard deviation, cmH2O): Method 1, 37.1 ± 13.6, Method 2, 71.4 ± 27.7, Method 3, 111.5 ± 8.8. Histological findings explained the difference in tolerable pressure at the repaired site between methods. Microscopic findings of lungs repaired using Method 3 indicated that the fibrinogen penetrated into deeper tissues to act as an anchor.

Conclusions

Fibrin glue sealing under ventilation increases the anchoring effect of repairing air leakages due to pleural defect in an ex-vivo model. This method may have clinical application. For example, it may be useful to reduce severe air leakage in patients who undergo lung-sparing surgery for a pleural tumor.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
PGA
Polyglycolic acid
VA
Ventilation-anchoring

Background

Air leakage remains a major complication of pulmonary surgery which can lead to prolonged drainage and severe complications such as empyema [1]. Fibrin sealant, in combination with bioabsorbable mesh, can be used to create a good seal following pulmonary surgery, and this combination is routinely used in clinics [24]. Recently, a new adhesive with the potential to replace blood products such as fibrin glue has shown promise in animal experiments [5].
In our clinical experience of pleurectomy/decortication (P/D) for pleural mesothelioma, we discovered that this combined technique is insufficient to control air leakage. All of the visceral pleura is removed during P/D surgery, meaning that conventional methods cannot control air leakage sufficiently, and long-term postoperative thoracic drainage, pleurodesis, and re-operation may be required. More efficient methods are needed in order to repair air leakage after pleural resection such as P/D; for which, the use of fibrin glue and polyglycolic acid (PGA) sheets shows potential [6, 7].
Several different techniques involving fibrin glue and PGA sheets have been reported [3, 810]. Some studies have demonstrated the utility of an optimized method of rubbing lung tissue with a fibrinogen solution and then placing a PGA sheet over the rubbed area [8, 11]. Histology has revealed the tissue penetration of fibrin glue to act like an anchor between the PGA sheet and lung parenchyma, which may explain the excellent adhesive strength of this combination [3, 9, 10].
We routinely perform lung ventilation to test the sealing after repair of an air leakage during pulmonary surgery. Therefore, in the present study, we examined both the conventional method and a novel method of sealing air leakage. The novel method aims to enhance the penetration of the fibrin glue by ventilating the lungs while rubbing the fibrinogen solution onto the lungs. This new method was tested using an ex-vivo model, and may provide an alternative approach to repairing pulmonary leakage, especially after P/D.

Methods

Ex-vivo model

Ex-vivo pig lungs were used for this study. Commercially available pig lungs (Tokyo-Shibaura Zouki Co. Ltd., Tokyo, Japan) were obtained, and we prepared a protocol to create the model in a laboratory. The ex-vivo model was created by a single surgeon, to replicate resection of the visceral pleura in lung-sparing surgery for malignant pleural mesothelioma. We used lungs obtained from dead animals; therefore, ethics approval and application procedures to the Animal Experimentation Review Board were not required.

Creation of the pleural defect

A balloon was inserted into the bronchus of an isolated porcine lung and connected to a nitrogen gas cylinder and pressure gage. A pleural defect (5 × 5 cm) was created by marking a 5-cm square on the lung surface (Fig. 1a) and incising the visceral pleura with a scalpel. While holding one end with forceps or fingers, the visceral pleura was peeled off with a Tupfer gauze to create a pleural defect within a square (Fig. 1b, c).

Tissue sealants

The materials as tissue sealants used in this study were commercially available. The sealant was fibrin glue (Bolheal®, Chemo-Sero Therapeutic Research Institute, Kumamoto, Japan) comprising fibrinogen (80 mg/ml) blood coagulation factor XIII (75 units/ml), bovine aprotinin (1000 units/ml), thrombin solution (250 units/ml), and calcium chloride (5.9 mg/ml). The tissue-absorbable sheets were composed of 0.15 mm thick PGA polymer (Neoveil®, Gunze Ltd. Co., Kyoto, Japan).

Sealing method

The pleural defect was repaired using fibrin glue and a PGA sheet (7 × 7 cm). Three methods of repairing lung defects were trialed. Method 1: mixed fibrin glue (2.5 ml) was sprayed over the PGA sheet covering the site of the pleural defect. Method 2: 1 ml of fibrinogen solution was spread onto the site using the finger-rubbing method [11] and sealed with the PGA sheet; then, mixed fibrin glue (1.5 ml) was sprayed over the sheet. Method 3: 1 ml of fibrinogen solution was spread as in Method 2, with gentle ventilation applied for five breaths during the procedure at a maximum airway pressure of 15 cmH20. The defect was then sealed with a PGA sheet and mixed fibrin glue (1.5 ml) sprayed over the sheet. The third method was the procedure that was developed in this study, with the aim of improving the repair of air leakage after the removal of visceral pleura. We named this method the ventilation-anchoring method (VA method).

Measurement of the seal-breaking pressure

Three minutes after the pleural defect was repaired, the highest pressure in the airway governing the repair site was measured. Nitrogen was slowly fed into the bronchus from the tube connected to the balloon, and the airway pressure when the sealing of the repair site failed was recorded as the maximum pressure resistance. The polymerization reaction of the fibrin glue product occurs within 3 min (in-house data, Kaketsuken); therefore, pressurization was initiated 3 min after repair, and a pressure test carried out every 3 min thereafter applying the mixed spray which included thrombin. This was carried out for lungs repaired by each method (n = 4 per method, One sample for each sealing-procedure).

Pathological evaluation

An experimental model with the pleural defect was created separately from the pressure test and was repaired using each method. To perform histopathological analysis, tissues including the lung parenchyma at the repaired site repaired by each method were excised and fixed in a 10% formaldehyde solution. The fixed specimens were embedded in paraffin, sectioned, and stained with hematoxylin and eosin for microscopic examination. Six specimens were prepared for each method. Representative histological findings are presented.

Statistical analysis

Data of seal-breaking pressure for each method were analyzed using the Wilcoxon rank sum test. Statistical analysis was performed using JMP Pro version 14.2 (SAS Institute Inc., Cary, NC, USA). All data are presented as the mean ± standard deviation. Statistical significance was accepted at p < 0.05.

Results

Seal-breaking pressure in the ex-vivo model

The maximum pressure resistance values of the lungs repaired using Methods 1, 2, and 3 are summarized in Table 1. Among these, the mean maximum pressure value was the highest for the lungs repaired by Method 3 (Fig. 2). There was a significant difference between Methods 2 and 3 (p = 0.03); however, there was no significant difference between Methods 1 and 2. In three out of the four lungs repaired using Method 3, pressure measurements were stopped due to bursting of the intact pleura before the repaired site failed.
Table 1
Seal-breaking pressure values of the ex-vivo models
 
Method 1
Method 2
Method 3
1
54.4
80.2
106.1
2
25.8
27.2
126.5
3
21.8
74.8
108.8
4
46.2
103.4
104.7
mean+/−SD
37.1+/−13.6
71.4+/−27.7
111.5+/−8.8
   
(cmH2O)

Histological evaluation

The degree of fibrin glue in the alveolar tissue reflected the difference in tolerable pressure at the repaired site for each Method (Fig. 3). For Method 1, fibrin glue was not observed to penetrate the lung parenchyma, nor did it adhere to the uneven surface of the plural defect (Fig. 3a). For Method 2, the PGA sheet was observed to be in close contact with the lung tissue. Partial penetration of fibrin glue into the lung tissue was observed (Fig. 3b). For Method 3, as for Method 2, the PGA sheet was in close contact with the lung tissue. When fibrin glue was identified at the microscopic level, it was found to consistently penetrate to a deeper area of the lung tissue than was observed for the other two methods (Fig. 3c).

Discussion

The use of fibrin glue and PGA sheets is a routine approach to control air leakage from visceral pleura in thoracic surgery [12]. Methods for repairing air leaks with sufficient strength over a wide area are highly important to ensure the success of P/D surgery [7].
The adhesion mechanism of fibrin involves the action of thrombin, which forms a complex with fibrin to achieve adhesion [13]. Compared with fibrin glue spray, the combination of fibrin glue and tissue-absorbable sheets has proven to be an efficient method for comparing burst pressure in various reports [8, 10, 11]. However, the present study revealed that the withstanding pressure can vary considerably, particularly in Method 2, and is potentially insufficient for clinical use.
The method developed in the present study which involved the use of fibrinogen with constant ventilation was found to increase the pressure tolerance of the repaired lung. We observed a stable pressure resistance, even at pressures that were high enough to cause normal lung tissue to rupture. Histological observations indicated that the new method created deep penetration of fibrin glue into the lung tissue in the area of the pleural defect, with the formation of fibrin clots. These results demonstrate that the application of fibrin solution under ventilation induces the glue to penetrate deeper into the tissue than conventional methods, creating a stronger anchor for the coated PGA sheet. We believe that this is the mechanism underlying the high-pressure resistance that we observed. Histological examination revealed no penetration of fibrin complex into the blood vessels; thus, we consider this method to be as safe as other methods. Due to the histological findings, we named this the VA method to reflect the additional procedure of ventilation and histological observations.
Our results indicate that the use of fibrin glue to seal lung tissue under ventilation can achieve good repair of air leakages after removal of the visceral pleura in an ex-vivo porcine model; the burst pressure of the lung can only be measured with such a model. In lungs repaired using the new method, we measured pressure tolerances that exceeded 100 cmH2O. Thus, the repair of pleural defects using the VA method can achieve repairs able to tolerate unexpected intrabronchial pressure, such as that experienced during severe cough after thoracotomy.
Compared with the conventional method (in which solution is rubbed onto the lung tissue [11]), our new method achieved increased pressure resistance according to the burst test using an ex-vivo pleural defect pig model. The effectiveness of pleural repair with fibrin glue and tissue-absorbable sheets was greatly enhanced when performed under ventilation. This finding may enable more effective seals to be created for the repair of air leakages after pleural resection. We have already applied this method in lung-sparing surgery for malignant pleural mesothelioma in our hospital, and have found the outcomes to be preferable to those of conventional methods. Thus, our method could have wide application in thoracic surgery.
This study has some limitations which should be acknowledged. First, the sample size was small, and so further validation is required. With the conventional method (Method 2), the results of the seal-breaking pressure measurement were varied; more accurate statistical analysis could be performed if the sample number were increased. However, for the newly developed method (Method 3), the seal-breaking pressure was relatively consistent. The creation of the model required a stable surgical procedure, so as not to affect the pressure tolerance values. Considering these limitations, we conclude that the findings presented here obtained using a small sample size demonstrated the stability and superiority of the new method.

Conclusions

Our results demonstrate that pleural defects can be repaired to achieve very high-pressure resistance with fibrin glue and PGA sheets using the VA method which involves rubbing fibrinogen on the defect under ventilation. In the future, we plan to evaluate the application of this method to clinical cases for the surgery of visceral pleural injury or resection.

Acknowledgements

The authors would like to thank Enago (www.​enago.​com) for English language review.
Not applicable.
Not applicable.

Competing interests

NK and SH received a lecture fee from KM Biologics Co., Ltd., and received the sealing agents and materials to support their experiments in this study. YT and SO are employees of KM Biologics Co., Ltd. MH and SM declare that they have no conflicts of interest.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Malapert G, Hanna HA, Pages PB, Bernard A. Surgical sealant for the prevention of prolonged air leak after lung resection: meta-analysis. Ann Thorac Surg. 2010;90:1779–85.CrossRef Malapert G, Hanna HA, Pages PB, Bernard A. Surgical sealant for the prevention of prolonged air leak after lung resection: meta-analysis. Ann Thorac Surg. 2010;90:1779–85.CrossRef
2.
Zurück zum Zitat Tsuda T, Nakamura T, Yamamoto Y, Teramachi M, Kiyotani T, Lee YH, et al. Prevention of postoperative air leakage from lungs using a purified human collagen membrane-polyglycolic acid sheet. Ann Thorac Surg. 1999;68:339–42.CrossRef Tsuda T, Nakamura T, Yamamoto Y, Teramachi M, Kiyotani T, Lee YH, et al. Prevention of postoperative air leakage from lungs using a purified human collagen membrane-polyglycolic acid sheet. Ann Thorac Surg. 1999;68:339–42.CrossRef
3.
Zurück zum Zitat Morikawa T, Katoh H. Improved techniques of applying fibrin glue in lung surgery. Eur Surg Res Eur Chir Forsch Rech Chir Eur. 1999;31:180–6. Morikawa T, Katoh H. Improved techniques of applying fibrin glue in lung surgery. Eur Surg Res Eur Chir Forsch Rech Chir Eur. 1999;31:180–6.
4.
Zurück zum Zitat Sakai T, Matsutani N, Kanai E, Yamauchi Y, Uehara H, Iinuma H, et al. Efficacy of a sheet combined with fibrin glue in repair of pleural defect at the early phase after lung surgery in a canine model. Gen Thorac Cardiovasc Surg. 2018;66:103–7.CrossRef Sakai T, Matsutani N, Kanai E, Yamauchi Y, Uehara H, Iinuma H, et al. Efficacy of a sheet combined with fibrin glue in repair of pleural defect at the early phase after lung surgery in a canine model. Gen Thorac Cardiovasc Surg. 2018;66:103–7.CrossRef
5.
Zurück zum Zitat Matoba M, Takagi T, Tsujimoto H, Ozamoto Y, Ueda J, Hagiwara A. Reduction of pulmonary air leaks with a combination of polyglycolic acid sheet and alginate gel in rats. Biomed Res Int. 2018;2018:3808675.CrossRef Matoba M, Takagi T, Tsujimoto H, Ozamoto Y, Ueda J, Hagiwara A. Reduction of pulmonary air leaks with a combination of polyglycolic acid sheet and alginate gel in rats. Biomed Res Int. 2018;2018:3808675.CrossRef
6.
Zurück zum Zitat Zahid I, Sharif S, Routledge T, Scarci M. Is pleurectomy and decortication superior to palliative care in the treatment of malignant pleural mesothelioma? Interact Cardiovasc Thorac Surg. 2011;12:812–7.CrossRef Zahid I, Sharif S, Routledge T, Scarci M. Is pleurectomy and decortication superior to palliative care in the treatment of malignant pleural mesothelioma? Interact Cardiovasc Thorac Surg. 2011;12:812–7.CrossRef
7.
Zurück zum Zitat Hasegawa S, Kondo N, Matsumoto S, Takuwa T, Hashimoto M, Kuroda A, et al. Surgical risk and survival associated with less invasive surgery for malignant pleural mesothelioma. Semin Thorac Cardiovasc Surg. 2019;31:301–9.CrossRef Hasegawa S, Kondo N, Matsumoto S, Takuwa T, Hashimoto M, Kuroda A, et al. Surgical risk and survival associated with less invasive surgery for malignant pleural mesothelioma. Semin Thorac Cardiovasc Surg. 2019;31:301–9.CrossRef
8.
Zurück zum Zitat Nomori H, Abe M, Sugimura H, Takegawa Y, Oka S, Takeshi A. Triple-layer sealing with absorptive mesh and fibrin glue is effective in preventing air leakage after segmentectomy: results from experiments and clinical study. Eur J Cardiothorac Surg. 2014;45:910–3.CrossRef Nomori H, Abe M, Sugimura H, Takegawa Y, Oka S, Takeshi A. Triple-layer sealing with absorptive mesh and fibrin glue is effective in preventing air leakage after segmentectomy: results from experiments and clinical study. Eur J Cardiothorac Surg. 2014;45:910–3.CrossRef
9.
Zurück zum Zitat Itano H. The optimal technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage. Eur J Cardiothorac Surg. 2008;33:457–60.CrossRef Itano H. The optimal technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage. Eur J Cardiothorac Surg. 2008;33:457–60.CrossRef
10.
Zurück zum Zitat Yano T, Haro A, Shikada Y, Okamoto T, Maruyama R, Maehara Y. A unique method for repairing intraoperative pulmonary air leakage with both polyglycolic acid sheets and fibrin glue. World J Surg. 2012;36:463–7.CrossRef Yano T, Haro A, Shikada Y, Okamoto T, Maruyama R, Maehara Y. A unique method for repairing intraoperative pulmonary air leakage with both polyglycolic acid sheets and fibrin glue. World J Surg. 2012;36:463–7.CrossRef
11.
Zurück zum Zitat Kin H, Nakajima T, Okabayashi H. Experimental study on effective application of fibrin glue. Gen Thorac Cardiovasc Surg. 2012;60:140–4.CrossRef Kin H, Nakajima T, Okabayashi H. Experimental study on effective application of fibrin glue. Gen Thorac Cardiovasc Surg. 2012;60:140–4.CrossRef
12.
Zurück zum Zitat Gika M, Kawamura M, Izumi Y, Kobayashi K. The short-term efficacy of fibrin glue combined with absorptive sheet material in visceral pleural defect repair. Interact Cardiovasc Thorac Surg. 2007;6:12–5.CrossRef Gika M, Kawamura M, Izumi Y, Kobayashi K. The short-term efficacy of fibrin glue combined with absorptive sheet material in visceral pleural defect repair. Interact Cardiovasc Thorac Surg. 2007;6:12–5.CrossRef
13.
Zurück zum Zitat Lerner R, Binur NS. Current status of surgical adhesives. J Surg Res. 1990;48:165–81.CrossRef Lerner R, Binur NS. Current status of surgical adhesives. J Surg Res. 1990;48:165–81.CrossRef
Metadaten
Titel
Development of an effective method utilizing fibrin glue to repair pleural defects in an ex-vivo pig model
verfasst von
Nobuyuki Kondo
Yoshitaka Takegawa
Masaki Hashimoto
Seiji Matsumoto
Shiro Oka
Seiki Hasegawa
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
Journal of Cardiothoracic Surgery / Ausgabe 1/2020
Elektronische ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-020-01158-3

Weitere Artikel der Ausgabe 1/2020

Journal of Cardiothoracic Surgery 1/2020 Zur Ausgabe

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Was nützt die Kraniektomie bei schwerer tiefer Hirnblutung?

17.05.2024 Hirnblutung Nachrichten

Eine Studie zum Nutzen der druckentlastenden Kraniektomie nach schwerer tiefer supratentorieller Hirnblutung deutet einen Nutzen der Operation an. Für überlebende Patienten ist das dennoch nur eine bedingt gute Nachricht.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.