Diagnostic analysis of new quantitative parameters of low-dose dynamic myocardial perfusion imaging with CZT SPECT in the detection of suspected or known coronary artery disease

verfasst von: Zekun Pang, Jiao Wang, Shuai Li, Yue Chen, Xiaojie Wang, Jianming Li

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 1/2021

Abstract

The goal of this study is to explore and evaluate the diagnostic values of myocardial blood flow (MBF), myocardial flow reserve (MFR) and relative flow reserve (RFR) obtained with low-dose dynamic CZT SPECT for patients with suspected or known coronary artery disease (CAD). Fifty-seven consecutive patients who underwent low-dose dynamic CZT SPECT and CAG were enrolled. MBF, MFR and RFR were calculated on the vessel level with dedicated quantitative software, and the difference and correlation of each parameter was compared according to the reference standard of stenosis ≥ 50% or ≥ 75% on CAG, respectively. ROC curves were made by stress MBF (sMBF), rest MBF (rMBF), MFR and RFR. The optimal cut-off values and corresponding diagnostic efficacy were obtained and compared with each other. Results indicated that when stenosis ≥ 50% or ≥ 75% on CAG was used as the reference standard at the vessel level, there was no statistically significant difference in rMBF between the negative group and the positive group (P > 0.05), and the sMBF and MFR in positive groups were significantly lower than that in the negative group (all P < 0.05). There was a moderate to significant correlation between sMBF and MFR, sMBF and RFR, MFR and RFR (all P < 0.0001). These results indicate that low-dose dynamic CZT SPECT imaging can easily obtain the sMBF, MFR and RFR, and there is a good correlation among the three parameters, which has a certain diagnostic value for patients with suspected or known CAD, and is a useful supplement to the conventional qualitative or semi-quantitative diagnostic methods.
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is an important non-invasive imaging diagnostic tool in diagnosis, risk stratification, prognosis and efficacy evaluation for coronary artery disease (CAD) [15]. The conventional SPECT MPI evaluates the presence, extent and degree of myocardial ischemia and/or infarction usually through visual observation or semi-quantitative parameters, such as summed stress score (SSS), summed rest score (SRS), summed different score (SDS) and total perfusion defect (TPD), etc., and there have been many researches on this field [6, 7].
In recent years, the “milestone” progress of SPECT is the advent and clinical application of cardiac-dedicated SPECT equipped with cadmium-zinc-tellurium (CZT) of semi-conductor detectors, which has greatly improved the performance of SPECT equipment [810]. CZT SPECT not only greatly improves the detection sensitivity and spatial resolution, but also reduces the single dose of injected radiopharmaceuticals, thereby reducing the radiation dose for the patients. Meanwhile, because the significantly improved time resolution of the detection and the projection data in the 180° range from the left anterior inclination 45° to the left posterior inclination 45° can be acquired at the same time without detector rotation around the body, realizing the fast and dynamic scan, which makes CZT SPECT convenient for quantitative measurement of myocardial blood flow (MBF). Therefore, CZT SPECT can not only achieve low-dose MPI imaging, but also provide some new parameters for quantitative analysis of absolute MBF through fast dynamic tomography, such as stress or rest myocardial blood flow (sMBF or rMBF), myocardial flow reserve (MFR) and relative flow reserve (RFR). Quantitative analysis has obvious advantages over visual observation or semi-quantitative analysis, especially for the left main (LM) and/or 3-vessels diseases, which improves the detective sensitivity and avoids missed diagnosis or underestimation [1114].
In the past, quantitative analysis of MPI mainly relied on positron emission computed tomography/computed tomography (PET/CT), but due to the expensive price and the limitation of the availability of positron perfusion imaging agents, it has not been widely used in clinical practice. With the popularization of cardiac-dedicated CZT SPECT, the quantitative analysis of MPI is highly expected again, and recently, some comparative studies [15, 16] have shown that it correlates well with the quantitative parameters measured by PET/CT. However, there are still relatively few studies on quantitative parameters obtained by CZT SPECT MPI in the diagnosis of CAD until now. Furthermore, according to literature retrieval, we discovered that the comparative analysis among MBF, MFR and RFR has not been reported yet. In this article, we intends to explore and compare the diagnostic values of MBF, MFR and RFR in patients with suspected or known CAD through quantitative analysis with low-dose dynamic CZT SPECT MPI.

Methods

Study Population

Patients with suspected or known CAD who underwent low-dose dynamic CZT SPECT MPI were continuously enrolled. Inclusion criteria: (1) The age is between 18 and 79 years old; (2) Have the invasive CAG data within 3 months before and after MPI examination, no revascularization treatment during the period; (3) Suitable for adenosine triphosphate (ATP) drug-stressed MPI and can tolerate the dynamic SPECT imaging process; (4) Signed the informed consent form; (5) The imaging data passed the quality control. Exclusion criteria: Highly unstable angina pectoris, old myocardial infarction, post-operative revascularization, atrioventricular block of degree II and above, sick sinus syndrome (except those who have a pacemaker), COPD (including asthma, bronchiectasis, emphysema, pulmonary fibrosis, etc.), severe hypotension (systolic blood pressure < 90 mmHg), severe mitral or aortic valve disease, cardiomyopathy (dilated, hypertrophic cardiomyopathy, etc.), CAG negative, but has clinical diagnosis of highly suspected coronary microvascular dysfunction (CMD) (such as syndrome X and microvascular angina) or coronary artery spasm, patients who fail to complete dynamic acquisition or complete dynamic acquisition but the image quality is not satisfactory, pregnant or lactating women. All patients were given informed consents and this study was approved by the Ethics Committee of TEDA International Cardiovascular Hospital(Tianjin, China).

Acquisition of CZT SPECT imaging

The device was a cardiac-dedicated SPECT (NM530c, GE Healthcare, Milwaukee, WI, USA), equipped with a CZT detector and the radionuclide imaging agent was 99mTc-MIBI. The technetium was provided by Beijing Senke Pharmaceutical Co., Ltd. or Tianjin HTA Isotope Pharmaceutical Co., Ltd. The MIBI was provided by Jiangyuan Pharmaceutical Factory of Jiangsu Atomic Energy Research Institute. The labeled radiochemical purity was ≥ 95%. Preparation for patients: within 24 h before the examination, strictly prohibit patients to drink coffee, tea, or any food containing caffeine and theophylline, and stop taking conventional medications for cardiovascular disease.
The acquisition used a “single-day” or “two-day” protocol: the “single-day” protocol was patients underwent CZT imaging with the administration of 185–296 MBq of 99mTc-MIBI during rest and three times dose of that at stress. ATP-stress imaging was performed 1–4 h after rest imaging and the method refer to the literature [17]. The “two-day” protocol injected the same dose of imaging agent at rest and stress was 370–555 MBq. Drank 350–500 mL of water before each collection on the machine. Rest imaging: pre-injected imaging agent 18.5–37 MBq (for pre-position imaging); after pre-positioning, started dynamic acquisition (list mode acquisition for 10 min), 10 s after started the program, “blous” injected imaging agent through the embedded vein channel within 5 s, and conventional rest gated tomography was performed 40–60 min after the dynamic acquisition. Stress imaging: After the patient's heart is pre-positioned, the imaging agent was injected at the peak of ATP-stress (at the 3rd min) and the injection method was same to the resting imaging. Continuous acquisition in list mode for 10 min, and then, after an interval of 15–30 min, the conventional stress gating tomography was carried out. General gated acquisition parameters: eight frames/cardiac cycle, heart rate window width ± 15%, and an energy window centered on the photopeak of 140 keV ± 10%. “Single-day” protocol’s rest and stress imaging were collected for 6 min and 4 min, respectively, and “two-day” protocol’s rest and stress imaging were both collected for 4 min. All patients needed to collect CT (NM690, GE company, USA) before SPECT imaging for attenuate correction data: the voltage was 120 kV, the current was 20 mA, the scanning range was from the lung tip to the middle and lower part of the liver.

Imaging analysis and judgment criteria

All dynamic list mode data was transferred to the MyoFlowQ (Beijing Bailingyun Bio-Pharmaceutical Co., Ltd.) workstation and automatically reframed into a series of dynamic images: 10 s × 10 frames, 20 s × 5 frames, 60 s × 2 frames, 280 s × 1 frame; then called the CT attenuation correction data to complete the fusion alignment, axial adjustment, attenuation and scattering correction of the CT and SPECT images; automatically or manually adjusted the region of interest (ROI) of the blood pool curve input function and myocardial basal position, the dynamic curve and fitting curve of LV blood pool and LV myocardium were finally obtained. From this, rMBF and sMBF of LV 3-vessel regions were gained, and then, the MFR of the 3-vessel regions was calculated (MFR = sMBF/rMBF). Afterwards, the product of resting systolic blood pressure and heart rate, that is, RPP (rate pressure product), was used to correct rMBF. The RFR of a vascular region in the bullseye was defined as the ratio of the average sMBF of the myocardial segment within the vascular perfusion region of that branch to the sMBF of the normal reference myocardial region [18]. The routine reconstructions for gated MPI were performed with the software of QPS + QGS (Cedars Sinai medical center, Los Angeles, USA). The 3-vessels of the LV included the left anterior descending (LAD), the left circumflex (LCX), and the right coronary artery (RCA).

Determination of vascular stenosis on CAG

Standard Judkins method was used for CAG. Two cardiologists with more than 3 years of interventional experience assessed the stenosis of coronary arteries with diameter ≥ 2 mm (visual assessment, consultation when there was a difference of opinion), and using stenosis ≥ 50% or ≥ 75% as the criteria for judging the positive.

Statistical analysis

Used stenosis ≥ 50% and ≥ 75% on CAG as the reference standard for diagnosing CAD, the rMBF, sMBF, MFR, and RFR values of each vascular region in each group were obtained at the vessel level, and the following statistical analysis was performed: (1) compared the differences of quantitative parameters between the two standards; (2) calculated the correlation of quantitative parameters between two standards; (3) made ROC curves for rMBF, sMBF, MFR, and RFR under two standards, to obtain the best cut-off value and the corresponding diagnostic efficacy for obstructive CAD and compared them with each other; (4) excluded the patients with 3-vessels disease in each group (each major branch has at least one stenosis ≥ 50%) and repeated the process (3). All data were processed using IBM SPSS 17.0; measurement data were expressed as x ± sd, and comparison was performed using T test; the relationship between quantitative parameters was analyzed by correlation. P < 0.05 was considered statistically significant.

Results

Fifty-seven patients with suspected or known CAD were included in this study, and their characteristics were shown in Table 1. The patients’ mean age was 62.1 ± 7.7 years, mean stature was 167 cm ± 8 cm, mean weight was 74.3 ± 11.3 kg, and 56.1% (n = 32) of the study population was male.
Table 1
Characteristics of the study population
Characteristics
N = 57 (%)
Male, n (%)
32 (56.1)
Female, n (%)
25 (43.9)
Negative (stenosis < 50% on CAG), n (%)
16 (28.1)
1-vessel CAD (stenosis ≥ 50% on CAG), n (%)
14 (24.6)
2-vessels CAD(stenosis ≥ 50% on CAG), n (%)
12 (21.1)
3-vessels CAD(stenosis ≥ 50% on CAG), n (%)
15 (26.3)
Hypertension, n (%)
37 (64.9)
Hyperlipidemia, n (%)
25 (43.9)
Diabetes, n (%)
9 (15.8)
Smoking, n (%)
19 (33.3)
Family history of CAD, n (%)
18 (31.6)
As shown in Table 2, when stenosis ≥ 50% or ≥ 75% on CAG was used as the reference standard at the vessel level, there was no statistically significant difference in rMBF between the negative group and the positive group (P > 0.05). Conversely, the sMBF and MFR in positive groups were both significantly lower than that in the negative group under two reference standards, and the difference was statistically significant (P < 0.05). Similarly, sMBF and MFR, sMBF and RFR, MFR and RFR all showed moderate to significant correlations. The correlation coefficients of the same group’s quantitative parameters were all similar under the two reference standards (r = 0.7611 and r = 0.6430, respectively, P < 0.0001) and the scatter diagram were shown in Fig. 1.
Table 2
Quantitative parameters and comparison among groups under two reference standards (at vessel level, n = 171)
Reference standard
rMBF (ml/g/min)
Statistic values
sMBF (ml/g/min)
Statistic values
MFR
Statistic values
RFR
Statistic values
 
Negative group
Positive group
 
Negative group
Positive group
 
Negative group
Positive group
 
Negative group
Positive group
 
 ≥ 50%
0.98 ± 0.25
0.93 ± 0.24
t = 1.40
2.03 ± 0.82
1.26 ± 0.50
t = 7.49
2.06 ± 0.83
1.34 ± 0.59
t = 6.51
0.80 ± 0.13
0.72 ± 0.14
t = 4.20
   
P = 0.69
  
P = 0.00*
  
P = 0.00*
  
P = 0.00*
 ≥ 75%
1.03 ± 0.24
0.95 ± 0.25
t = 1.94
1.89 ± 0.79
1.15 ± 0.48
t = 7.61
1.93 ± 0.82
1.25 ± 0.56
t = 6.26
0.83 ± 0.13
0.74 ± 0.14
t = 4.21
   
P = 0.05
  
P = 0.00*
  
P = 0.00*
  
P = 0.00*
*P < 0.05
*P < 0.05
According to the standard of stenosis ≥ 50% of LAD, LCX and RCA on CAG, the patients were divided into 4 groups: non-obstructive atherosclerosis group (negative stenosis in all vessels), 1-vessel CAD group, 2-vessels CAD group and 3-vessels CAD group. The average and standard deviation of LV-rMBF, LV-sMBF and LV-MFR in each group were calculated. (1) non-obstructive atherosclerosis group: the values were 1.08 ± 0.27 ml/g/min, 2.33 ± 0.80 ml/g/min and 2.28 ± 0.86 ml/g/min, respectively. (2) 1-vessel CAD group: the values were 0.95 ± 0.17 ml/g/min, 1.67 ± 0.54 ml/g/min and 1.82 ± 0.67 ml/g/min, respectively. (3) 2-vessels CAD group: the values were 0.95 ± 0.21 ml/g/min, 1.47 ± 0.42 ml/g/min and 1.62 ± 0.54 ml/g/min, respectively. (4) 3-vessels CAD group: the values were 1.02 ± 0.07 ml/g/min, 1.12 ± 0.39 ml/g/min and 1.11 ± 0.32 ml/g/min, respectively. The comparison of LV-rMBF, LV-sMBF and LV-MFR in each group was shown in Fig. 2. According to Fig. 2, there was no statistical difference between any two groups of LV-rMBF (P > 0.05), and on the contrary, there was a statistically significant difference between most paried groups for LV-sMBF and LV-MFR (except for 1-vessel CAD group vs 2-vessels CAD group and 2-vessels CAD group vs 3-vessels CAD group) (P < 0.05).
The relevant parameters of the ROC curve of each quantitative parameter under two reference standards were shown in Table 3. With stenosis ≥ 50% as the reference standard, the AUC comparison of sMBF and MFR had no significant statistical difference: Z = 1.215, P = 0.2244; the AUC comparison of sMBF and RFR had statistical difference: Z = 3.003, P = 0.0027; and the AUC comparison of MFR and RFR had no significant statistical difference: Z = 2.282, P = 0.0225. Based on the optimal cut-off values of sMBF and MFR determined in Table 3, the correct rates for the detection of 3-vessels CAD at the case level were 100% (15/15) and 73.3% (11/15), respectively. With stenosis ≥ 75% as the reference standard, the AUC comparison of sMBF and MFR had no significant statistical difference: Z = 1.471, P = 0.1414; the AUC comparison of sMBF and RFR had statistical difference: Z = 2.896, P = 0.0038; and the AUC comparison of MFR and RFR had statistical difference: Z = 1.982, P = 0.0475. The corresponding ROC curve was shown in Fig. 3.
Table 3
ROC curve parameters of quantitative parameters under two reference standards (at vessel level, n = 171)
Reference standard
Parameters
AUC
95% CI
Youden index
Optimal cut-off values
SN (%)
SP (%)
Z
P values
 ≥ 50%
sMBF
0.798
0.730–0.855
0.4618
1.48 ml/g/min
72.62
73.56
8.939
 < 0.0001
MFR
0.772
0.720–0.833
0.4433
1.77
85.70
58.6
7.649
 < 0.0001
RFR
0.685
0.609–0.753
0.2693
0.75
47.62
79.31
4.569
 < 0.0001
 ≥ 75%
sMBF
0.801
0.733–0.858
0.5088
1.48 ml/g/min
83.64
67.24
8.563
 < 0.0001
MFR
0.770
0.699–0.831
0.4436
1.76
90.91
53.45
7.056
 < 0.0001
RFR
0.690
0.614–0.758
0.2773
0.75
52.73
75.00
4.480
 < 0.0001
In order to eliminate the possible effect of 3-vessel CAD on RFR, the AUC comparison of the quantitative parameters under two reference standards was measured again after excluding the patients with 3-vessels CAD. After excluding data from patients with 3-vessels CAD, using stenosis ≥ 50% as the reference standard, the AUC comparison results of sMBF and MFR: Z = 1.565, P = 0.1177; the AUC comparison results of sMBF and RFR: Z = 1.753, P = 0.0796; and the AUC comparison results of MFR and RFR: Z = 0.813, P = 0.4164. There was no statistical difference in these results. Similarly, after excluding data from patients with 3-vessels CAD, using stenosis ≥ 75% as the reference standard, the AUC comparison results of sMBF and MFR: Z = 1.686, P = 0.0917; the AUC comparison results of sMBF and RFR: Z = 0.605, P = 0.5449; and the AUC comparison results of MFR and RFR: Z = 0.239, P = 0.8168. There was no statistical difference in these results. The corresponding ROC curve is shown in Fig. 4.
A typical case who underwent quantification analysis was showed in Fig. 5, and new quantitative parameters, such rMBF, sMBF, MFR and RFR, were obtained with the software of MyoFlowQ. Those quantitative parameters, such as sMBF, MFR and RFR, were very much abnormal, which indicated that this patient’s heart was in a very serious condition.

Discussion

According to the literature search, the present study is the first to use low-dose CZT SPECT continuous dynamic tomography imaging to obtain some new quantitative parameters of MBF, such as sMBF, MFR and RFR, to evaluate and compare their correlation and diagnostic value in patients with suspected or known CAD. In this study, we found that for sMBF, MFR and RFR, no matter which reference standard (stenosis ≥ 50% or ≥ 75%) on CAG, the parameter values in the positive group were significantly lower than those in the negative group, and there was statistical difference. At the vessel level, no matter using stenosis ≥ 50% or ≥ 75% on CAG as the reference standard, there was a moderate to significant correlation among sMBF, MFR and RFR. In the four groups of non-obstructive atherosclerosis group, 1-vessel CAD group, 2-vessels CAD group and 3-vessels CAD group, there was no statistical difference between any two groups of LV-rMBF, suggesting that it did not have diagnostic value, while sMBF and MFR tended to decrease gradually, and there was a statistically significant difference between any two groups of LV-sMBF and LV-MFR (expect in 1-vessel CAD group vs 2-vessels CAD group and 2-vessels CAD group vs 3-vessels CAD group). Through the analysis of ROC curve, sMBF, MFR and RFR showed better diagnostic performance, of which sMBF was the most prominent, no matter which reference standard of stenosis ≥ 50% or ≥ 75% on CAG. When the patients with 3-vessels CAD were excluded, there was no statistical difference in diagnostic performance among the three parameters.
As we all know, conventional SPECT MPI plays an important role in non-invasive imaging diagnosis and evaluation of CAD [15]. However, some shortcomings of conventional SPECT MPI have also been reported, such as large imaging agent injection dose, long collection time, low image resolution, poor specificity of semi-quantitative analysis, and easy to underestimate or even miss diagnosis of LM and/or 3-vessels lesions [11, 12]. Therefore, how to make up for the shortcomings of conventional SPECT MPI has become a “hot point” of research. Luckily, the introduction of CZT SPECT provides great help to solve these problems, which is regarded as a “milestone” progress, and greatly improves the imaging performance of SPECT equipment [810]. PET/CT is considered as the “gold standard” in the application of quantitative MBF and its related parameters, but it is only applied in some large heart centers at present, and there are many limitations in clinical implementation, such as expensive equipment and drugs, limited installed capacity and passing capacity, etc. CZT SPECT has the ability of fast continuous tomographic imaging, convenient drug supply and relatively low-cost equipment. At the same time, the improvement of image sensitivity and resolution makes low-dose imaging easy to realize. Therefore, it has great hope in reducing radiation dose, rapid imaging, MBF quantification and clinical application. Recent studies [15, 16] suggest that compared with PET/CT MBF quantification, CZT SPECT has a better correlation with it, confirming its accuracy and convenience.
In general, when using SPECT MPI to diagnose CAD, one of the main factors affecting visual evaluation and semi-quantitative analysis is that we must choose a “normal” reference firstly, while the “normal” reference itself may not be “normal”. For example, (1) FOR the LM lesions, because the reduced blood flow is scattered in the LAD and LCX regions, compared with the “normal” RCA region, the semi-quantitative analysis leads to the underestimation of the lesion degree. If the RCA has obvious lesions at the same time, it may be further underestimated or even missed. (2) For 3-vessels lesions, the MBF in the 3-vessels regions has decreased in different degrees, while the regions with relatively low degree of perfusion defects are regarded as a “normal” reference, resulting in the extent of ischemia being underestimated. (3) If there are 3-vessels balanced lesions, due to the lack of contrast, it may lead to missed diagnosis. In this study, taking the cut-off values of MFR or sMBF obtained by ROC analysis as the diagnostic standard, the accuracy of judging 15 cases of 3-vessels lesions was 100% (15/15) and 73.3% (11/15), respectively, suggesting that the analysis of blood flow quantitative parameters has good value in multi-vessel lesions. In addition, due to the low energy of single-photon radionuclides, SPECT MPI artifacts caused by soft tissue attenuation have become a common problem, such as female dense tissue and/ or breast, as well as male diaphragm attenuation artifacts, is the common source of false positive diagnosis, but also the main reason for the poor specificity of conventional SPECT MPI diagnosis [19, 20]. MPI quantitative blood flow analysis plays an important role in overcoming the shortcomings of conventional SPECT imaging diagnosis because of complete attenuation and scattering correction and eliminating the effect of attenuation artifacts. The sMBF is the peak of MBF in the case of the peak effect of vasodilators, which is related to epicardial coronary artery dilatation and microcirculatory resistance.
Physiological experiments have confirmed that for the normal coronary artery system, the peak blood flow under drug-stress can be increased by 3 to 5 times as much as at rest. Gould et al. [21] first used experimental methods to verify the relationship between CFR (defined as MFR) and coronary artery stenosis, and the results showed that CFR was not affected when coronary stenosis was less than 50%, but decreased significantly in 50 to 95%, which was mainly caused by reduced stress blood flow, and pointed out that the stenosis on CAG could not directly predict the corresponding hemodynamic abnormalities. MFR is also an independent factor to predict the prognosis of patients, and the negative MFR of the global left ventricle has a better negative predictive value for high-risk patients [22]. Both Fame I and Fame II tests showed that the benefit of patients with coronary revascularization guided by FFR, was significantly better than that of CAG alone [23, 24].
RFR is defined by the ratio of a stenotic regional sMBF to normal perfusion regional sMBF obtained by quantitative MPI, which is considered to be similar to FFR, and can be used as an effective index to diagnose CAD [25]. Early studies [26] have shown that there is a good correlation between invasive FFR measured by pressure guide wire and RFR obtained by 15O-water PET (r = 0.87). At present, FFR measured by pressure guide wire has been used as an invasive “gold standard” to judge whether epicardial coronary artery stenosis affects myocardial perfusion. In this study, we found that sMBF, MFR and RFR in the positive group were lower than those in the negative group, and with the improvement of diagnostic criteria, there was a trend of further synchronous decrease, and the correlation among the three parameters was moderate or above. ROC curve analysis showed that the diagnostic efficiency of the three parameters was very strong, which was consistent with the results of previous studies [27, 28]. However, previous studies did not compare the correlation and diagnostic ability of sMBF, MFR and RFR at the same time, mostly analyzed one or two of them, and did not discuss the two commonly used CAD diagnostic criteria of stenosis ≥ 50% and 75% on CAG, respectively. The reference standard on CAG for clinical diagnosis of CAD is usually stenosis ≥ 50%, however, as the anatomical standard of interventional therapy or not, it is usually considered to be stenosis ≥ 70–80%. Therefore, the present study is divided into two situations and analyzed separately, in order to simulate the clinical actual situation. This is the innovation of this study design compared with previous studies, and we found that the diagnostic ability of sMBF is similar to MFR, when the 3-vessles CAD patients are removed, there is no significant difference in diagnostic ability among the three parameters, and it also suggests that RFR is not suitable for the diagnosis of 3-vessels lesions, because the reference regional sMBF is also decreased, resulting in no significant decrease in RFR. Conversely, sMBF and MFR are not affected by this, the wider the lesion is involved, the more obvious the decrease will be, which is confirmed in the analysis of grouping in this study. Therefore, sMBF and MFR have the same important values in the diagnosis and evaluation of obstructive CAD. It should be noted that for patients with negative CAG but with CMD, MPI tomographic images may be normal, while sMBF and CFR may be decreased [29]. At this point, if CAG is taken as the reference standard, the positive result of quantitative blood flow will be defined as false positive. Therefore, clinically suspected CMD was included in the exclusion criteria of this study.

Study limitations

First, the sample size of this study is relatively small and due to the limitation of clinical technical accessibility, and it is not compared with the “gold” standard of FFR and index of microvascular resistance (IMR), which reflect epicardial coronary artery perfusion and microcirculation function. Second, obstructive CAD with microcirculation dysfunction cannot be distinguished by CZT SPECT quantitative parameters. Third, although clinically suspected CMD patients are enrolled in the exclusion criteria, due to the lack of IMR verification, it is not fully guaranteed whether CMD patients with atypical symptoms are included. Fourth, we admitted that although the recognized diagnostic cut-off value of MFR is 2.0–2.5, there is no unified diagnostic cut-off value for sMBF and RFR. Finally, due to different types of equipment and imaging agents, different physical correction factors, such as between CZT SPECT and PET/CT, between different types of CZT SPECT, between single-photon drugs and positron drugs, and between different single-photon drugs or positron drugs, the quantitative parameters obtained need to be further studied in detail.

Conclusion

Our results demonstrate that new myocardial quantitative blood flow parameters of sMBF, MFR and RFR can be easily obtained by low-dose dynamic CZT SPECT, and the parameter values in the positive group were significantly lower than those in the negative group. There is a good correlation among the three parameters, which has a certain diagnostic values for patients with suspected or known CAD, and is a useful supplement to the conventional qualitative or semi-quantitative diagnostic methods.

Compliance with ethical standards

Conflicts of interest

The authors declare that they have no conflict of interest.

Ethical approval

This study was approved by the local ethics committee of our institution, and conformed to the ethical principles outlined in the Declaration of Helsinki.
Written informed consent was obtained from individual or guardian participants.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Al Badarin FJ, Malhotra S (2019) Diagnosis and prognosis of coronary artery disease with SPECT and PET. Curr Cardiol Rep 21:57CrossRef Al Badarin FJ, Malhotra S (2019) Diagnosis and prognosis of coronary artery disease with SPECT and PET. Curr Cardiol Rep 21:57CrossRef
4.
Zurück zum Zitat Peovska Mitevska I, Davceva Pavlovska J, Srbinovska E et al (2014) Ischaemia-driven optimal therapeutic approach in asymptomatic patients with high cardiovascular risk: the value of clinical, laboratory and myocardial spect imaging findings. Pril (Makedon Akad Nauk Umet Odd Med Nauki) 35:141–148 Peovska Mitevska I, Davceva Pavlovska J, Srbinovska E et al (2014) Ischaemia-driven optimal therapeutic approach in asymptomatic patients with high cardiovascular risk: the value of clinical, laboratory and myocardial spect imaging findings. Pril (Makedon Akad Nauk Umet Odd Med Nauki) 35:141–148
5.
Zurück zum Zitat Djaïleb L, Riou L, Piliero N et al (2018) SPECT myocardial ischemia in the absence of obstructive CAD: contribution of the invasive assessment of microvascular dysfunction. J Nucl Cardiol 25:1017–1022CrossRef Djaïleb L, Riou L, Piliero N et al (2018) SPECT myocardial ischemia in the absence of obstructive CAD: contribution of the invasive assessment of microvascular dysfunction. J Nucl Cardiol 25:1017–1022CrossRef
6.
Zurück zum Zitat Doğan C, Çınaral F, Karagöz A et al (2019) Comparison of automated quantification and semiquantitative visual analysis findings of IQ SPECT MPI with conventional coronary angiography in patients with stable angina. Turk Kardiyol Dern Ars 47:357–364PubMed Doğan C, Çınaral F, Karagöz A et al (2019) Comparison of automated quantification and semiquantitative visual analysis findings of IQ SPECT MPI with conventional coronary angiography in patients with stable angina. Turk Kardiyol Dern Ars 47:357–364PubMed
7.
Zurück zum Zitat Chavoshi M, Fard-Esfahani A, Fallahi B et al (2015) Assessment of prognostic value of semiquantitative parameters on gated single photon emission computed tomography myocardial perfusion scintigraphy in a large middle eastern population. Indian J Nucl Med 30:233–238CrossRef Chavoshi M, Fard-Esfahani A, Fallahi B et al (2015) Assessment of prognostic value of semiquantitative parameters on gated single photon emission computed tomography myocardial perfusion scintigraphy in a large middle eastern population. Indian J Nucl Med 30:233–238CrossRef
8.
Zurück zum Zitat Fiechter M, Ghadri JR, Kuest SM et al (2011) Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography. Eur J Nucl Med Mol Imag 38:2025–2030CrossRef Fiechter M, Ghadri JR, Kuest SM et al (2011) Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography. Eur J Nucl Med Mol Imag 38:2025–2030CrossRef
9.
Zurück zum Zitat Herzog BA, Buechel RR, Husmann L et al (2010) Validation of CT attenuation correction for high-speed myocardial perfusion imaging using a novel cadmium-zinc-telluride detector technique. J Nucl Med 51:1539–1544CrossRef Herzog BA, Buechel RR, Husmann L et al (2010) Validation of CT attenuation correction for high-speed myocardial perfusion imaging using a novel cadmium-zinc-telluride detector technique. J Nucl Med 51:1539–1544CrossRef
10.
Zurück zum Zitat Duvall WL, Sweeny JM, Croft LB et al (2012) Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography. J Nucl Cardiol 19:19–27CrossRef Duvall WL, Sweeny JM, Croft LB et al (2012) Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography. J Nucl Cardiol 19:19–27CrossRef
11.
Zurück zum Zitat Berman DS, Kang X, Slomka PJ et al (2007) Underestimation of extent of ischemia by gated SPECT myocardial perfusion imaging in patients with left main coronary artery disease. J Nucl Cardiol 14:521–528CrossRef Berman DS, Kang X, Slomka PJ et al (2007) Underestimation of extent of ischemia by gated SPECT myocardial perfusion imaging in patients with left main coronary artery disease. J Nucl Cardiol 14:521–528CrossRef
12.
Zurück zum Zitat Ghadri JR, Pazhenkottil AP, Nkoulou RN et al (2011) Very high coronary calcium score unmasks obstructive coronary artery disease in patients with normal SPECT MPI. Heart 97:998–1003CrossRef Ghadri JR, Pazhenkottil AP, Nkoulou RN et al (2011) Very high coronary calcium score unmasks obstructive coronary artery disease in patients with normal SPECT MPI. Heart 97:998–1003CrossRef
13.
Zurück zum Zitat Ziadi MC (2017) Myocardial flow reserve (MFR) with positron emission tomography (PET)/computed tomography (CT): clinical impact in diagnosis and prognosis. Cardiovasc Diagn Ther 7:206–218CrossRef Ziadi MC (2017) Myocardial flow reserve (MFR) with positron emission tomography (PET)/computed tomography (CT): clinical impact in diagnosis and prognosis. Cardiovasc Diagn Ther 7:206–218CrossRef
14.
Zurück zum Zitat Driessen RS, Raijmakers PG, Stuijfzand WJ et al (2017) Myocardial perfusion imaging with PET. Int J Cardiovasc Imag 33:1021–1031CrossRef Driessen RS, Raijmakers PG, Stuijfzand WJ et al (2017) Myocardial perfusion imaging with PET. Int J Cardiovasc Imag 33:1021–1031CrossRef
17.
Zurück zum Zitat Yao Z, Zhu H, Li W et al (2017) Adenosine triphosphate stress myocardial perfusion imaging for risk stratification of patients aged 70 years and older with suspected coronary artery disease. J Nucl Cardiol 24:429–433CrossRef Yao Z, Zhu H, Li W et al (2017) Adenosine triphosphate stress myocardial perfusion imaging for risk stratification of patients aged 70 years and older with suspected coronary artery disease. J Nucl Cardiol 24:429–433CrossRef
18.
Zurück zum Zitat Stuijfzand WJ, Uusitalo V, Kero T et al (2015) Relative flow reserve derived from quantitative perfusion imaging may not outperform stress myocardial blood flow for identification of hemodynamically significant coronary artery disease. Circ Cardiovasc Imag 8:e002400CrossRef Stuijfzand WJ, Uusitalo V, Kero T et al (2015) Relative flow reserve derived from quantitative perfusion imaging may not outperform stress myocardial blood flow for identification of hemodynamically significant coronary artery disease. Circ Cardiovasc Imag 8:e002400CrossRef
19.
Zurück zum Zitat Oddstig J, Martinsson E, Jögi J et al (2019) Differences in attenuation pattern in myocardial SPECT between CZT and conventional gamma cameras. J Nucl Cardiol 26:1984–1991CrossRef Oddstig J, Martinsson E, Jögi J et al (2019) Differences in attenuation pattern in myocardial SPECT between CZT and conventional gamma cameras. J Nucl Cardiol 26:1984–1991CrossRef
20.
Zurück zum Zitat Mannarino T, Assante R, Ricciardi C et al (2019) Head-to-head comparison of diagnostic accuracy of stress-only myocardial perfusion imaging with conventional and cadmium-zinc telluride single-photon emission computed tomography in women with suspected coronary artery disease. J Nucl Cardiol. https://doi.org/10.1007/s12350-019-01789-7CrossRefPubMed Mannarino T, Assante R, Ricciardi C et al (2019) Head-to-head comparison of diagnostic accuracy of stress-only myocardial perfusion imaging with conventional and cadmium-zinc telluride single-photon emission computed tomography in women with suspected coronary artery disease. J Nucl Cardiol. https://​doi.​org/​10.​1007/​s12350-019-01789-7CrossRefPubMed
21.
Zurück zum Zitat Gould KL, Lipscomb K, Hamilton GW (1974) Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol 33:87–94CrossRef Gould KL, Lipscomb K, Hamilton GW (1974) Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol 33:87–94CrossRef
22.
Zurück zum Zitat Naya M, Murthy VL, Taqueti VR et al (2014) Preserved coronary flow reserve effectively excludes high-risk coronary artery disease on angiography. J Nucl Med 55:248–255CrossRef Naya M, Murthy VL, Taqueti VR et al (2014) Preserved coronary flow reserve effectively excludes high-risk coronary artery disease on angiography. J Nucl Med 55:248–255CrossRef
23.
Zurück zum Zitat Fearon WF, Nishi T, De Bruyne B et al (2018) clinical outcomes and cost-effectiveness of fractional flow reserve-guided percutaneous coronary intervention in patients with stable coronary artery disease: three-year follow-up of the FAME 2 trial (fractional flow reserve versus angiography for multivessel evaluation). Circulation 137:480–487CrossRef Fearon WF, Nishi T, De Bruyne B et al (2018) clinical outcomes and cost-effectiveness of fractional flow reserve-guided percutaneous coronary intervention in patients with stable coronary artery disease: three-year follow-up of the FAME 2 trial (fractional flow reserve versus angiography for multivessel evaluation). Circulation 137:480–487CrossRef
24.
Zurück zum Zitat Sels JW, Tonino PA, Siebert U et al (2011) Fractional flow reserve in unstable angina and non-ST-segment elevation myocardial infarction experience from the FAME (fractional flow reserve versus angiography for multivessel evaluation) study. JACC Cardiovasc Interv 4:1183–1189CrossRef Sels JW, Tonino PA, Siebert U et al (2011) Fractional flow reserve in unstable angina and non-ST-segment elevation myocardial infarction experience from the FAME (fractional flow reserve versus angiography for multivessel evaluation) study. JACC Cardiovasc Interv 4:1183–1189CrossRef
25.
Zurück zum Zitat Lee JM, Kim CH, Koo BK et al (2016) Integrated myocardial perfusion imaging diagnostics improve detection of functionally significant coronary artery stenosis by 13N-ammonia positron emission tomography. Circ Cardiovasc Imag 9:e004768CrossRef Lee JM, Kim CH, Koo BK et al (2016) Integrated myocardial perfusion imaging diagnostics improve detection of functionally significant coronary artery stenosis by 13N-ammonia positron emission tomography. Circ Cardiovasc Imag 9:e004768CrossRef
26.
Zurück zum Zitat De Bruyne B, Baudhuin T, Melin JA et al (1994) Coronary flow reserve calculated from pressure measurements in humans Validation with positron emission tomography. Circulation 89:1013–1022CrossRef De Bruyne B, Baudhuin T, Melin JA et al (1994) Coronary flow reserve calculated from pressure measurements in humans Validation with positron emission tomography. Circulation 89:1013–1022CrossRef
28.
Zurück zum Zitat Miyagawa M, Nishiyama Y, Uetani T et al (2017) Estimation of myocardial flow reserve utilizing an ultrafast cardiac SPECT: comparison with coronary angiography, fractional flow reserve, and the SYNTAX score. Int J Cardiol 244:347–353CrossRef Miyagawa M, Nishiyama Y, Uetani T et al (2017) Estimation of myocardial flow reserve utilizing an ultrafast cardiac SPECT: comparison with coronary angiography, fractional flow reserve, and the SYNTAX score. Int J Cardiol 244:347–353CrossRef
29.
Zurück zum Zitat Campisi R, Marengo FD (2017) Coronary microvascular dysfunction in women with nonobstructive ischemic heart disease as assessed by positron emission tomography. Cardiovasc Diagn Ther 7:196–205CrossRef Campisi R, Marengo FD (2017) Coronary microvascular dysfunction in women with nonobstructive ischemic heart disease as assessed by positron emission tomography. Cardiovasc Diagn Ther 7:196–205CrossRef
Metadaten
Titel
Diagnostic analysis of new quantitative parameters of low-dose dynamic myocardial perfusion imaging with CZT SPECT in the detection of suspected or known coronary artery disease
verfasst von
Zekun Pang
Jiao Wang
Shuai Li
Yue Chen
Xiaojie Wang
Jianming Li
Publikationsdatum
10.09.2020
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 1/2021
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-020-01962-x

Weitere Artikel der Ausgabe 1/2021

The International Journal of Cardiovascular Imaging 1/2021 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.