Skip to main content
Erschienen in: Japanese Journal of Radiology 2/2015

01.02.2015 | Original Article

Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences

verfasst von: Murat Ucar, Nil Tokgoz, Cagri Damar, Ayse Gul Alimli, Fatih Oncu

Erschienen in: Japanese Journal of Radiology | Ausgabe 2/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate efficacy of three-dimensional (3D) heavily T2-weighted (W) MRI sequences in assessment of cerebrospinal fluid (CSF) pathways and to compare two different types of 3D heavily T2W MRI sequences (CISS and SPACE) with two-dimensional (2D) T2W turbo spin echo (TSE) sequences for hydrocephalus with intraventricular obstruction.

Materials and methods

Sixty-two patients who were diagnosed with intraventricular obstructive hydrocephalus, according to clinical and radiological findings, were included in this retrospective study. 2D-TSE-T2, 3D-CISS, and 3D-SPACE, which are part of the protocol, were analyzed quantitatively by measuring ventricle-to-parenchyma contrast-to-noise ratio (CNR), and qualitatively by evaluating the capabilities of visualization of the obstructive pathology, overall image quality, severity of artifacts, and delineation of the CSF pathways. One-way ANOVA and Friedman’s test were used for statistical analysis.

Results

CNR between CSF and brain parenchyma was significantly higher using 3D-SPACE sequences compared with 3D-CISS and 2D-TSE-T2 sequences. The qualitative findings showed that 3D heavily T2W sequences were superior to 2D-TSE-T2 sequences. 3D-SPACE sequences showed fewer artifacts than 3D-CISS or 2D-TSE-T2 sequences.

Conclusion

3D heavily T2W sequences are necessary tools for assessment of CSF pathways in patients with intraventricular obstructive hydrocephalus. 3D-SPACE sequences allowed heavy T2W, which is necessary for CSF flow imaging and provided significantly fewer image artifacts and improved CNR in comparison with 3D-CISS sequences.
Literatur
1.
Zurück zum Zitat Rekate HL. A consensus on the classification of hydrocephalus: its utility in the assessment of abnormalities of cerebrospinal fluid dynamics. Childs Nerv Syst. 2011;27:1535–41.CrossRefPubMedCentralPubMed Rekate HL. A consensus on the classification of hydrocephalus: its utility in the assessment of abnormalities of cerebrospinal fluid dynamics. Childs Nerv Syst. 2011;27:1535–41.CrossRefPubMedCentralPubMed
2.
Zurück zum Zitat Kartal MG, Algin O. Evaluation of hydrocephalus and other cerebrospinal fluid disorders with MRI: an update. Insights Imaging. 2014;6:531–41.CrossRef Kartal MG, Algin O. Evaluation of hydrocephalus and other cerebrospinal fluid disorders with MRI: an update. Insights Imaging. 2014;6:531–41.CrossRef
3.
Zurück zum Zitat Hodel J, Rahmouni A, Zins M, Vignaud A, Decq P. Magnetic resonance imaging of noncommunicating hydrocephalus. World Neurosurg. 2013;79(S21):e9–12.PubMed Hodel J, Rahmouni A, Zins M, Vignaud A, Decq P. Magnetic resonance imaging of noncommunicating hydrocephalus. World Neurosurg. 2013;79(S21):e9–12.PubMed
4.
Zurück zum Zitat Dinçer A, Özek MM. Radiologic evaluation of pediatric hydrocephalus. Childs Nerv Syst. 2011;27:1543–62.CrossRefPubMed Dinçer A, Özek MM. Radiologic evaluation of pediatric hydrocephalus. Childs Nerv Syst. 2011;27:1543–62.CrossRefPubMed
5.
Zurück zum Zitat Awaji M, Okamoto K, Nishiyama K. Magnetic resonance cisternography for preoperative evaluation of arachnoid cysts. Neuroradiology. 2007;49:721–6.CrossRefPubMed Awaji M, Okamoto K, Nishiyama K. Magnetic resonance cisternography for preoperative evaluation of arachnoid cysts. Neuroradiology. 2007;49:721–6.CrossRefPubMed
6.
Zurück zum Zitat Kojima S, Suzuki K, Hirata M, Shinohara H, Ueno E. Depicting the semicircular canals with inner-ear MRI: a comparison of the SPACE and TrueFISP sequences. J Magn Reson Imaging. 2013;37:652–9.CrossRefPubMed Kojima S, Suzuki K, Hirata M, Shinohara H, Ueno E. Depicting the semicircular canals with inner-ear MRI: a comparison of the SPACE and TrueFISP sequences. J Magn Reson Imaging. 2013;37:652–9.CrossRefPubMed
7.
Zurück zum Zitat Mugler JP, Bao S, Mulkern RV, Guttmann CRG, Robertson RL, Jolesz FA, et al. Optimized single-slab three-dimensional spin-echo MR imaging of the brain. Radiology. 2000;216:891–9.CrossRefPubMed Mugler JP, Bao S, Mulkern RV, Guttmann CRG, Robertson RL, Jolesz FA, et al. Optimized single-slab three-dimensional spin-echo MR imaging of the brain. Radiology. 2000;216:891–9.CrossRefPubMed
8.
Zurück zum Zitat Watanabe Y, Makidono A, Nakamura M, Saida Y. 3D MR cisternography to identify distal dural rings: comparison of 3D-CISS and 3D-SPACE sequences. Magn Reson Med Sci. 2011;10:29–32.CrossRefPubMed Watanabe Y, Makidono A, Nakamura M, Saida Y. 3D MR cisternography to identify distal dural rings: comparison of 3D-CISS and 3D-SPACE sequences. Magn Reson Med Sci. 2011;10:29–32.CrossRefPubMed
9.
Zurück zum Zitat Fushimi Y, Miki Y, Ueba T, Kanagaki M, Takahashi T, Yamamoto A, et al. Liliequist membrane: three-dimensional constructive interference in steady state MR imaging. Radiology. 2003;229:360–5.CrossRefPubMed Fushimi Y, Miki Y, Ueba T, Kanagaki M, Takahashi T, Yamamoto A, et al. Liliequist membrane: three-dimensional constructive interference in steady state MR imaging. Radiology. 2003;229:360–5.CrossRefPubMed
10.
Zurück zum Zitat Aleman J, Jokura H, Higano S, Akabane A, Shirane R, Yoshimoto T. Value of constructive interference in steady-state three-dimensional, Fourier transformation magnetic resonance imaging for the neuroendoscopic treatment of hydrocephalus and intracranial cysts. Neurosurgery. 2001;48:1291–5 discussion 1295–6.PubMed Aleman J, Jokura H, Higano S, Akabane A, Shirane R, Yoshimoto T. Value of constructive interference in steady-state three-dimensional, Fourier transformation magnetic resonance imaging for the neuroendoscopic treatment of hydrocephalus and intracranial cysts. Neurosurgery. 2001;48:1291–5 discussion 1295–6.PubMed
11.
Zurück zum Zitat Dinçer a, Kohan S, Ozek MM. Is all “communicating” hydrocephalus really communicating? Prospective study on the value of 3D-constructive interference in steady state sequence at 3T. AJNR Am J Neuroradiol. 2009;30:1898–906.CrossRefPubMed Dinçer a, Kohan S, Ozek MM. Is all “communicating” hydrocephalus really communicating? Prospective study on the value of 3D-constructive interference in steady state sequence at 3T. AJNR Am J Neuroradiol. 2009;30:1898–906.CrossRefPubMed
12.
Zurück zum Zitat Held P, Fellner C, Fellner F, Seitz J, Strutz J. MRI of inner ear anatomy using 3D MP-RAGE and 3D CISS sequences. Br J Radiol. 1997;70:465–72.CrossRefPubMed Held P, Fellner C, Fellner F, Seitz J, Strutz J. MRI of inner ear anatomy using 3D MP-RAGE and 3D CISS sequences. Br J Radiol. 1997;70:465–72.CrossRefPubMed
13.
Zurück zum Zitat Algin O, Hakyemez B, Parlak M. Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis. Neuroradiology. 2010;52:99–108.CrossRefPubMed Algin O, Hakyemez B, Parlak M. Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis. Neuroradiology. 2010;52:99–108.CrossRefPubMed
14.
Zurück zum Zitat Algin O, Turkbey B. Evaluation of aqueductal stenosis by 3D sampling perfection with application-optimized contrasts using different flip angle evolutions sequence: preliminary results with 3T MR imaging. AJNR Am J Neuroradiol. 2012;33:740–6.CrossRefPubMed Algin O, Turkbey B. Evaluation of aqueductal stenosis by 3D sampling perfection with application-optimized contrasts using different flip angle evolutions sequence: preliminary results with 3T MR imaging. AJNR Am J Neuroradiol. 2012;33:740–6.CrossRefPubMed
15.
Zurück zum Zitat Algin O, Turkbey B, Ozmen E, Ocakoglu G, Karaoglanoglu M, Arslan H. Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: preliminary results with variant flip-angle mode. J Neuroradiol. 2013;40:11–8.CrossRefPubMed Algin O, Turkbey B, Ozmen E, Ocakoglu G, Karaoglanoglu M, Arslan H. Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: preliminary results with variant flip-angle mode. J Neuroradiol. 2013;40:11–8.CrossRefPubMed
16.
Zurück zum Zitat Naganawa S, Koshikawa T, Fukatsu H, Ishigaki T, Fukuta T. MR cisternography of the cerebellopontine angle: comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences. AJNR Am J Neuroradiol. 2001;22:1179–85.PubMed Naganawa S, Koshikawa T, Fukatsu H, Ishigaki T, Fukuta T. MR cisternography of the cerebellopontine angle: comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences. AJNR Am J Neuroradiol. 2001;22:1179–85.PubMed
17.
Zurück zum Zitat Haystead CM, Dale BM, Merkle EM. N/2 ghosting artifacts: elimination at 3.0-T MR cholangiography with SPACE pulse sequence. Radiology. 2008;246:589–95.CrossRefPubMed Haystead CM, Dale BM, Merkle EM. N/2 ghosting artifacts: elimination at 3.0-T MR cholangiography with SPACE pulse sequence. Radiology. 2008;246:589–95.CrossRefPubMed
Metadaten
Titel
Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
verfasst von
Murat Ucar
Nil Tokgoz
Cagri Damar
Ayse Gul Alimli
Fatih Oncu
Publikationsdatum
01.02.2015
Verlag
Springer Japan
Erschienen in
Japanese Journal of Radiology / Ausgabe 2/2015
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-014-0385-y

Weitere Artikel der Ausgabe 2/2015

Japanese Journal of Radiology 2/2015 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.