Skip to main content
Erschienen in: Abdominal Radiology 6/2015

01.08.2015

Digital subtraction angiography during transjugular intrahepatic portosystemic shunt creation or revision: data on radiation exposure and image quality obtained using a standard and a low-dose acquisition protocol in a flat-panel detector-based system

verfasst von: Roberto Miraglia, Luigi Maruzzelli, Kelvin Cortis, Corrado Tafaro, Roberta Gerasia, Carmelo Parisi, Angelo Luca

Erschienen in: Abdominal Radiology | Ausgabe 6/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To determine whether the use of a low-dose acquisition protocol (LDP) in digital subtraction angiography during transjugular intrahepatic portosystemic shunt (TIPS) creation/revision results in significant reduction of patient radiation exposure and adequate image quality, as compared to a default reference standard-dose acquisition protocol (SDP).

Methods

Two angiographic runs were performed during TIPS creation/revision: the first following catheterization of the portal venous system and the second after stent deployment/angioplasty. Constant field of view, object to image-detector distance, and source to image-receptor distance were maintained in each patient during the two angiographic runs. 17 consecutive adult patients who underwent TIPS creation (n = 11) or TIPS revision (n = 6) from December 2013 to March 2014 were considered eligible for this single centre prospective study. In each patient, the LDP and the SDP were used in a random order for the two runs, with each patient serving as his/her own control. The dose-area product (DAP) was calculated for each image and compared. Image quality was graded by two interventional radiologists other than the operator.

Results

In all runs acquired with the LDP, image quality was considered adequate for a successful procedural outcome. The DAP per image of the LDP was numerically inferior as compared to the DAP per image of the SDP in all patients. The mean reduction in DAP per image was 75.24% ± 5.7% (p < 0. 001).

Conclusion

Radiation exposure during TIPS creation/revision was significantly reduced by selecting a LDP in our flat-panel detector-based system, while maintaining adequate image quality.
Literatur
1.
Zurück zum Zitat Pitton MB, Kloeckner R, Schneider J, et al. (2012) Radiation exposure in vascular angiographic procedures. J Vasc Interv Radiol 23(11):1487–1495PubMedCrossRef Pitton MB, Kloeckner R, Schneider J, et al. (2012) Radiation exposure in vascular angiographic procedures. J Vasc Interv Radiol 23(11):1487–1495PubMedCrossRef
2.
Zurück zum Zitat Kuon E, Robinson DM, Empen K, Dahm JB (2005) Fluoroscopy time—an overestimated factor for patient radiation exposure in invasive cardiology. Rofo 177:812–817PubMedCrossRef Kuon E, Robinson DM, Empen K, Dahm JB (2005) Fluoroscopy time—an overestimated factor for patient radiation exposure in invasive cardiology. Rofo 177:812–817PubMedCrossRef
3.
Zurück zum Zitat Miller DL, Balter S, Cole PE, et al. (2003) Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. J Vasc Interv Radiol 14(6):711–727PubMedCrossRef Miller DL, Balter S, Cole PE, et al. (2003) Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. J Vasc Interv Radiol 14(6):711–727PubMedCrossRef
4.
Zurück zum Zitat Zweers D, Geleijns J, Aarts NJ, et al. (1998) Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose reduction, using dedicated fluoroscopy exposure settings. Br J Radiol 71(846):672–676PubMedCrossRef Zweers D, Geleijns J, Aarts NJ, et al. (1998) Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose reduction, using dedicated fluoroscopy exposure settings. Br J Radiol 71(846):672–676PubMedCrossRef
5.
Zurück zum Zitat Garcia-Pagan JC, Heydtmann M, Raffa S, et al. (2008) TIPS for Budd–Chiari syndrome: long-term results and prognostics factors in 124 patients. Gastroenterology 135(3):808–815PubMedCrossRef Garcia-Pagan JC, Heydtmann M, Raffa S, et al. (2008) TIPS for Budd–Chiari syndrome: long-term results and prognostics factors in 124 patients. Gastroenterology 135(3):808–815PubMedCrossRef
6.
Zurück zum Zitat Tripathi D, Macnicholas R, Kothari C, et al. (2014) Good clinical outcomes following transjugular intrahepatic portosystemic stent-shunts in Budd–Chiari syndrome. Aliment Pharmacol Ther 39(8):864–872PubMedCrossRef Tripathi D, Macnicholas R, Kothari C, et al. (2014) Good clinical outcomes following transjugular intrahepatic portosystemic stent-shunts in Budd–Chiari syndrome. Aliment Pharmacol Ther 39(8):864–872PubMedCrossRef
7.
Zurück zum Zitat Seijo S, Plessier A, Hoekstra J, et al. (2013) Good long-term outcome of Budd–Chiari syndrome with a step-wise management. Hepatology 57(5):1962–1968PubMedCrossRef Seijo S, Plessier A, Hoekstra J, et al. (2013) Good long-term outcome of Budd–Chiari syndrome with a step-wise management. Hepatology 57(5):1962–1968PubMedCrossRef
8.
Zurück zum Zitat Di Giorgio A, Agazzi R, Alberti D, Colledan M, D’Antiga L (2012) Feasibility and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) in children. J Pediatr Gastroenterol Nutr 54(5):594–600PubMedCrossRef Di Giorgio A, Agazzi R, Alberti D, Colledan M, D’Antiga L (2012) Feasibility and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) in children. J Pediatr Gastroenterol Nutr 54(5):594–600PubMedCrossRef
9.
Zurück zum Zitat Mermuys K, Maleux G, Heye S, Lombaerts R, Nevens F (2008) Use of the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation in children: initial clinical experience. Cardiovasc Intervent Radiol 31(Suppl 2):S192–196PubMedCrossRef Mermuys K, Maleux G, Heye S, Lombaerts R, Nevens F (2008) Use of the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation in children: initial clinical experience. Cardiovasc Intervent Radiol 31(Suppl 2):S192–196PubMedCrossRef
10.
Zurück zum Zitat Vo NJ, Shivaram G, Andrews RT, et al. (2012) Midterm follow-up of transjugular intrahepatic portosystemic shunts using polytetrafluoroethylene endografts in children. J Vasc Interv Radiol 23(7):919–924PubMedCrossRef Vo NJ, Shivaram G, Andrews RT, et al. (2012) Midterm follow-up of transjugular intrahepatic portosystemic shunts using polytetrafluoroethylene endografts in children. J Vasc Interv Radiol 23(7):919–924PubMedCrossRef
11.
Zurück zum Zitat Pillai AK, Joseph AM, Reddick M, Toomay S, Kalva S (2014) Intravascular US-guided transjugular intrahepatic portosystemic shunt creation in a second-trimester pregnancy to prophylactically decompress abdominal wall varices before cesarean section. J Vasc Interv Radiol 25(3):481–483PubMedCrossRef Pillai AK, Joseph AM, Reddick M, Toomay S, Kalva S (2014) Intravascular US-guided transjugular intrahepatic portosystemic shunt creation in a second-trimester pregnancy to prophylactically decompress abdominal wall varices before cesarean section. J Vasc Interv Radiol 25(3):481–483PubMedCrossRef
12.
Zurück zum Zitat Savage C, Patel J, Lepe MR, Lazarre CH, Rees CR (2007) Transjugular intrahepatic portosystemic shunt creation for recurrent gastrointestinal bleeding during pregnancy. J Vasc Interv Radiol 18(7):902–904PubMedCrossRef Savage C, Patel J, Lepe MR, Lazarre CH, Rees CR (2007) Transjugular intrahepatic portosystemic shunt creation for recurrent gastrointestinal bleeding during pregnancy. J Vasc Interv Radiol 18(7):902–904PubMedCrossRef
13.
Zurück zum Zitat Arasaratnam P, Low W, Wilkinson N, Felix C, Beri N, Ho H, Foo D, Ong P (2012) Radiation dose in Asia Pacific region—how low can we go? Paper presented at European Society of Cardiology (ESC) Congress, Aug 25–29, Munich, Germany Arasaratnam P, Low W, Wilkinson N, Felix C, Beri N, Ho H, Foo D, Ong P (2012) Radiation dose in Asia Pacific region—how low can we go? Paper presented at European Society of Cardiology (ESC) Congress, Aug 25–29, Munich, Germany
14.
Zurück zum Zitat Miraglia R, Maruzzelli L, Tuzzolino F, Indovina PL, Luca A (2013) Radiation exposure in biliary procedures performed to manage anastomotic strictures in pediatric liver transplant recipients: comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system. Cardiovasc Interv Radiol 36(6):1670–1676CrossRef Miraglia R, Maruzzelli L, Tuzzolino F, Indovina PL, Luca A (2013) Radiation exposure in biliary procedures performed to manage anastomotic strictures in pediatric liver transplant recipients: comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system. Cardiovasc Interv Radiol 36(6):1670–1676CrossRef
15.
Zurück zum Zitat Suzuki S, Furui S, Kobayashi I, et al. (2005) Radiation dose to patients and radiologists during transcatheter arterial embolization: comparison of a digital flat-panel system and conventional unit. Am J Roentgenol 185(4):855–859CrossRef Suzuki S, Furui S, Kobayashi I, et al. (2005) Radiation dose to patients and radiologists during transcatheter arterial embolization: comparison of a digital flat-panel system and conventional unit. Am J Roentgenol 185(4):855–859CrossRef
16.
Zurück zum Zitat Soderman M, Holmin S, Andersson T, et al. (2013) Image noise reduction algorithm for digital subtraction angiography: clinical results. Radiology 269(2):553–560PubMedCrossRef Soderman M, Holmin S, Andersson T, et al. (2013) Image noise reduction algorithm for digital subtraction angiography: clinical results. Radiology 269(2):553–560PubMedCrossRef
Metadaten
Titel
Digital subtraction angiography during transjugular intrahepatic portosystemic shunt creation or revision: data on radiation exposure and image quality obtained using a standard and a low-dose acquisition protocol in a flat-panel detector-based system
verfasst von
Roberto Miraglia
Luigi Maruzzelli
Kelvin Cortis
Corrado Tafaro
Roberta Gerasia
Carmelo Parisi
Angelo Luca
Publikationsdatum
01.08.2015
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 6/2015
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-014-0313-8

Weitere Artikel der Ausgabe 6/2015

Abdominal Radiology 6/2015 Zur Ausgabe

Classics in Abdominal Imaging

The “bear paw” sign

Classics in Abdominal Imaging

The onion ring sign

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.