Skip to main content
Erschienen in: Inflammation Research 12/2013

01.12.2013 | Original Research Paper

Direct comparison of laser Doppler flowmetry and laser Doppler imaging for assessment of experimentally-induced inflammation in human skin

verfasst von: Lars J. Petersen

Erschienen in: Inflammation Research | Ausgabe 12/2013

Einloggen, um Zugang zu erhalten

Abstract

Objective and design

Laser Doppler imaging (LDI) and laser Doppler flowmetry (LDF) can measure localized skin perfusion. The purpose of the study was to directly compare LDF with LDI as a tool for measuring skin blood changes in an experimental model of chemically-induced skin inflammation.

Methods

Regions of interest 1.8 cm2 in area on the forearm skin of eight healthy volunteers were randomized and exposed to 0.25, 0.5, 1, or 2 % topical sodium lauryl sulfate (SLS) or vehicle for 24 h. Mean blood flow was measured by LDI and LDF at 24, 48, and 72 h. Inflammation was clinically graded using a standardized, clinical score.

Results

Sodium lauryl sulfate induced significant, dose-dependent local inflammation. Both Doppler methods were significantly correlated with the clinical grading (LDF, r = 0.755; LDI, r = 0.836). LDF and LDI showed similar significance differences with regard to dose- and time-response patterns compared to the vehicle. The absolute and relative LDF and LDI values were significantly correlated.

Conclusions

Laser Doppler flowmetry and LDI showed similar dose- and time-response relations in irritant-induced inflammatory skin reactions. For the assessment of localized skin reactions, LDI possesses no apparent advantages over the less expensive LDF method for grading dermal inflammatory reactions.
Literatur
1.
Zurück zum Zitat Engelhart M, Petersen LJ, Kristensen JK. The local regulation of blood flow evaluated simultaneously by 133-xenon washout and laser Doppler flowmetry. J Invest Dermatol. 1988;91:451–3.PubMedCrossRef Engelhart M, Petersen LJ, Kristensen JK. The local regulation of blood flow evaluated simultaneously by 133-xenon washout and laser Doppler flowmetry. J Invest Dermatol. 1988;91:451–3.PubMedCrossRef
2.
Zurück zum Zitat Cracowski JL, Minson CT, Salvat-Melis M, Halliwill JR. Methodological issues in the assessment of skin microvascular endothelial function in humans. Trends Pharmacol Sci. 2006;27:503–8.PubMedCrossRef Cracowski JL, Minson CT, Salvat-Melis M, Halliwill JR. Methodological issues in the assessment of skin microvascular endothelial function in humans. Trends Pharmacol Sci. 2006;27:503–8.PubMedCrossRef
3.
Zurück zum Zitat Roustit M, Blaise S, Millet C, Cracowski JL. Reproducibility and methodological issues of skin post-occlusive and thermal hyperemia assessed by single-point laser Doppler flowmetry. Microvasc Res. 2010;79:102–8.PubMedCrossRef Roustit M, Blaise S, Millet C, Cracowski JL. Reproducibility and methodological issues of skin post-occlusive and thermal hyperemia assessed by single-point laser Doppler flowmetry. Microvasc Res. 2010;79:102–8.PubMedCrossRef
4.
Zurück zum Zitat Tew GA, Klonizakis M, Crank H, Briers JD, Hodges GJ. Comparison of laser speckle contrast imaging with laser Doppler for assessing microvascular function. Microvasc Res. 2011;82:326–32.PubMedCrossRef Tew GA, Klonizakis M, Crank H, Briers JD, Hodges GJ. Comparison of laser speckle contrast imaging with laser Doppler for assessing microvascular function. Microvasc Res. 2011;82:326–32.PubMedCrossRef
5.
Zurück zum Zitat Clough GF, Bennett AR, Church MK. Effects of H1 antagonists on the cutaneous vascular response to histamine and bradykinin: a study using scanning laser Doppler imaging. Br J Dermatol. 1998;138:806–14.PubMedCrossRef Clough GF, Bennett AR, Church MK. Effects of H1 antagonists on the cutaneous vascular response to histamine and bradykinin: a study using scanning laser Doppler imaging. Br J Dermatol. 1998;138:806–14.PubMedCrossRef
6.
Zurück zum Zitat Bray R, Forrester K, Leonard C, McArthur R, Tulip J, Lindsay R. Laser Doppler imaging of burn scars: a comparison of wavelength and scanning methods. Burns. 2003;29:199–206.PubMedCrossRef Bray R, Forrester K, Leonard C, McArthur R, Tulip J, Lindsay R. Laser Doppler imaging of burn scars: a comparison of wavelength and scanning methods. Burns. 2003;29:199–206.PubMedCrossRef
7.
Zurück zum Zitat Opazo Saez AM, Mosel F, Nurnberger J, Rushentsova U, Gossl M, Mitchell A, Schafers RF, Philipp T, Wenzel RR. Laser Doppler imager (LDI) scanner and intradermal injection for in vivo pharmacology in human skin microcirculation: responses to acetylcholine, endothelin-1 and their repeatability. Br J Clin Pharmacol. 2005;59:511–9.PubMedCrossRef Opazo Saez AM, Mosel F, Nurnberger J, Rushentsova U, Gossl M, Mitchell A, Schafers RF, Philipp T, Wenzel RR. Laser Doppler imager (LDI) scanner and intradermal injection for in vivo pharmacology in human skin microcirculation: responses to acetylcholine, endothelin-1 and their repeatability. Br J Clin Pharmacol. 2005;59:511–9.PubMedCrossRef
8.
Zurück zum Zitat Fluhr JW, Kuss O, Diepgen T, Lazzerini S, Pelosi A, Gloor M, Berardesca E. Testing for irritation with a multifactorial approach: comparison of eight non-invasive measuring techniques on five different irritation types. Br J Dermatol. 2001;145:696–703.PubMedCrossRef Fluhr JW, Kuss O, Diepgen T, Lazzerini S, Pelosi A, Gloor M, Berardesca E. Testing for irritation with a multifactorial approach: comparison of eight non-invasive measuring techniques on five different irritation types. Br J Dermatol. 2001;145:696–703.PubMedCrossRef
9.
Zurück zum Zitat Kernick DP, Shore AC. Characteristics of laser Doppler perfusion imaging in vitro and in vivo. Physiol Meas. 2000;21:333–40.PubMedCrossRef Kernick DP, Shore AC. Characteristics of laser Doppler perfusion imaging in vitro and in vivo. Physiol Meas. 2000;21:333–40.PubMedCrossRef
10.
Zurück zum Zitat Klonizakis M, Manning G, Donnelly R. Assessment of lower limb microcirculation: exploring the reproducibility and clinical application of laser Doppler techniques. Skin Pharmacol Physiol. 2011;24:136–43.PubMedCrossRef Klonizakis M, Manning G, Donnelly R. Assessment of lower limb microcirculation: exploring the reproducibility and clinical application of laser Doppler techniques. Skin Pharmacol Physiol. 2011;24:136–43.PubMedCrossRef
11.
Zurück zum Zitat Roustit M, Millet C, Blaise S, Dufournet B, Cracowski JL. Excellent reproducibility of laser speckle contrast imaging to assess skin microvascular reactivity. Microvasc Res. 2010;80:505–11.PubMedCrossRef Roustit M, Millet C, Blaise S, Dufournet B, Cracowski JL. Excellent reproducibility of laser speckle contrast imaging to assess skin microvascular reactivity. Microvasc Res. 2010;80:505–11.PubMedCrossRef
12.
Zurück zum Zitat Seifalian AM, Stansby G, Jackson A, Howell K, Hamilton G. Comparison of laser Doppler perfusion imaging, laser Doppler flowmetry, and thermographic imaging for assessment of blood flow in human skin. Eur J Vasc Surg. 1994;8:65–9.PubMedCrossRef Seifalian AM, Stansby G, Jackson A, Howell K, Hamilton G. Comparison of laser Doppler perfusion imaging, laser Doppler flowmetry, and thermographic imaging for assessment of blood flow in human skin. Eur J Vasc Surg. 1994;8:65–9.PubMedCrossRef
13.
Zurück zum Zitat Broby-Johansen U, Karlsmark T, Petersen LJ, Serup J. Ranking of the antipsoriatic effect of various topical corticosteroids applied under a hydrocolloid dressing—skin-thickness, blood-flow and colour measurements compared to clinical assessments. Clin Exp Dermatol. 1990;15:343–8.PubMedCrossRef Broby-Johansen U, Karlsmark T, Petersen LJ, Serup J. Ranking of the antipsoriatic effect of various topical corticosteroids applied under a hydrocolloid dressing—skin-thickness, blood-flow and colour measurements compared to clinical assessments. Clin Exp Dermatol. 1990;15:343–8.PubMedCrossRef
14.
Zurück zum Zitat Henricson J, Tesselaar E, Persson K, Nilsson G, Sjoberg F. Assessment of microvascular function by study of the dose-response effects of iontophoretically applied drugs (acetylcholine and sodium nitroprusside)—methods and comparison with in vitro studies. Microvasc Res. 2007;73:143–9.PubMedCrossRef Henricson J, Tesselaar E, Persson K, Nilsson G, Sjoberg F. Assessment of microvascular function by study of the dose-response effects of iontophoretically applied drugs (acetylcholine and sodium nitroprusside)—methods and comparison with in vitro studies. Microvasc Res. 2007;73:143–9.PubMedCrossRef
15.
Zurück zum Zitat Leahy MJ, Enfield JG, Clancy NT, O’Doherty J, McNamara P, Nilsson GE. Biophotonic methods in microcirculation imaging. Med Laser Appl. 2007;22:105–26.CrossRef Leahy MJ, Enfield JG, Clancy NT, O’Doherty J, McNamara P, Nilsson GE. Biophotonic methods in microcirculation imaging. Med Laser Appl. 2007;22:105–26.CrossRef
16.
Zurück zum Zitat Tupker RA, Willis C, Berardesca E, Lee CH, Fartasch M, Agner T, Serup J. Guidelines on sodium lauryl sulfate (SLS) exposure tests: a report from the Standardization Group of the European Society of Contact Dermatitis. Contact Dermat. 1997;37:53–69.CrossRef Tupker RA, Willis C, Berardesca E, Lee CH, Fartasch M, Agner T, Serup J. Guidelines on sodium lauryl sulfate (SLS) exposure tests: a report from the Standardization Group of the European Society of Contact Dermatitis. Contact Dermat. 1997;37:53–69.CrossRef
17.
Zurück zum Zitat Petersen LJ, Lyngholm AM, Arendt-Nielsen L. A novel model of inflammatory pain in human skin involving topical application of sodium lauryl sulfate. Inflamm Res. 2010;59:775–81.PubMedCrossRef Petersen LJ, Lyngholm AM, Arendt-Nielsen L. A novel model of inflammatory pain in human skin involving topical application of sodium lauryl sulfate. Inflamm Res. 2010;59:775–81.PubMedCrossRef
18.
Zurück zum Zitat Fullerton A, Stucker M, Wilhelm KP, Wardell K, Anderson C, Fischer T, Nilsson GE, Serup J. Guidelines for visualization of cutaneous blood flow by laser Doppler perfusion imaging: a report from the Standardization Group of the European Society of Contact Dermatitis based upon the HIRELADO European community project. Contact Dermat. 2002;46:129–40.CrossRef Fullerton A, Stucker M, Wilhelm KP, Wardell K, Anderson C, Fischer T, Nilsson GE, Serup J. Guidelines for visualization of cutaneous blood flow by laser Doppler perfusion imaging: a report from the Standardization Group of the European Society of Contact Dermatitis based upon the HIRELADO European community project. Contact Dermat. 2002;46:129–40.CrossRef
19.
Zurück zum Zitat Petersen LJ, Church MK, Skov PS. Histamine is released in the wheal but not the flare following challenge of human skin in vivo: a microdialysis study. Clin Exp Allergy. 1997;27:284–95.PubMedCrossRef Petersen LJ, Church MK, Skov PS. Histamine is released in the wheal but not the flare following challenge of human skin in vivo: a microdialysis study. Clin Exp Allergy. 1997;27:284–95.PubMedCrossRef
20.
Zurück zum Zitat Petersen LJ, Zacho HD, Lyngholm AM, Arendt-Nielsen L. Tissue viability imaging for assessment of pharmacologically induced vasodilation and vasoconstriction in human skin. Microvasc Res. 2010;80:499–504.PubMedCrossRef Petersen LJ, Zacho HD, Lyngholm AM, Arendt-Nielsen L. Tissue viability imaging for assessment of pharmacologically induced vasodilation and vasoconstriction in human skin. Microvasc Res. 2010;80:499–504.PubMedCrossRef
21.
Zurück zum Zitat O’Doherty J, McNamara P, Clancy NT, Enfield JG, Leahy MJ. Comparison of instruments for investigation of microcirculatory blood flow and red blood cell concentration. J Biomed Opt. 2009;14:034025.PubMedCrossRef O’Doherty J, McNamara P, Clancy NT, Enfield JG, Leahy MJ. Comparison of instruments for investigation of microcirculatory blood flow and red blood cell concentration. J Biomed Opt. 2009;14:034025.PubMedCrossRef
22.
Zurück zum Zitat Staberg B, Serup J. Allergic and irritant skin reactions evaluated by laser Doppler flowmetry. Contact Dermat. 1988;18:40–5.CrossRef Staberg B, Serup J. Allergic and irritant skin reactions evaluated by laser Doppler flowmetry. Contact Dermat. 1988;18:40–5.CrossRef
23.
Zurück zum Zitat Goon AT, Leow YH, Chan YH, Goh CL. Correlation between laser Doppler perfusion imaging and visual scoring of patch test sites in subjects with experimentally induced allergic and irritant contact reactions. Skin Res Technol. 2004;10:64–6.PubMedCrossRef Goon AT, Leow YH, Chan YH, Goh CL. Correlation between laser Doppler perfusion imaging and visual scoring of patch test sites in subjects with experimentally induced allergic and irritant contact reactions. Skin Res Technol. 2004;10:64–6.PubMedCrossRef
24.
Zurück zum Zitat Fullerton A, Rode B, Serup J. Skin irritation typing and grading based on laser Doppler perfusion imaging. Skin Res Technol. 2002;8:23–31.PubMedCrossRef Fullerton A, Rode B, Serup J. Skin irritation typing and grading based on laser Doppler perfusion imaging. Skin Res Technol. 2002;8:23–31.PubMedCrossRef
25.
Zurück zum Zitat Farnebo S, Zettersten EK, Samuelsson A, Tesselaar E, Sjoberg F. Assessment of blood flow changes in human skin by microdialysis urea clearance. Microcirculation. 2011;18:198–204.PubMedCrossRef Farnebo S, Zettersten EK, Samuelsson A, Tesselaar E, Sjoberg F. Assessment of blood flow changes in human skin by microdialysis urea clearance. Microcirculation. 2011;18:198–204.PubMedCrossRef
26.
Zurück zum Zitat Roustit M, Maggi F, Isnard S, Hellmann M, Bakken B, Cracowski JL. Reproducibility of a local cooling test to assess microvascular function in human skin. Microvasc Res. 2010;79:34–9.PubMedCrossRef Roustit M, Maggi F, Isnard S, Hellmann M, Bakken B, Cracowski JL. Reproducibility of a local cooling test to assess microvascular function in human skin. Microvasc Res. 2010;79:34–9.PubMedCrossRef
27.
Zurück zum Zitat Bircher A, de Boer EM, Agner T, Wahlberg JE, Serup J. Guidelines for measurement of cutaneous blood flow by laser Doppler flowmetry: a report from the Standardization Group of the European Society of Contact Dermatitis. Contact Dermat. 1994;30:65–72.CrossRef Bircher A, de Boer EM, Agner T, Wahlberg JE, Serup J. Guidelines for measurement of cutaneous blood flow by laser Doppler flowmetry: a report from the Standardization Group of the European Society of Contact Dermatitis. Contact Dermat. 1994;30:65–72.CrossRef
28.
Zurück zum Zitat Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135–60.PubMedCrossRef Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135–60.PubMedCrossRef
29.
Zurück zum Zitat Hopkins WG. Measures of reliability in sports medicine and science. Sports Med. 2000;30:1–15.PubMedCrossRef Hopkins WG. Measures of reliability in sports medicine and science. Sports Med. 2000;30:1–15.PubMedCrossRef
Metadaten
Titel
Direct comparison of laser Doppler flowmetry and laser Doppler imaging for assessment of experimentally-induced inflammation in human skin
verfasst von
Lars J. Petersen
Publikationsdatum
01.12.2013
Verlag
Springer Basel
Erschienen in
Inflammation Research / Ausgabe 12/2013
Print ISSN: 1023-3830
Elektronische ISSN: 1420-908X
DOI
https://doi.org/10.1007/s00011-013-0668-2

Weitere Artikel der Ausgabe 12/2013

Inflammation Research 12/2013 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.