Dose reduction technique in diagnostic X-ray computed tomography by use of 6-channel multileaf collimators

verfasst von: Fumio Hashimoto, Atsushi Teramoto, Yasuki Asada, Shoichi Suzuki, Hiroshi Fujita

Erschienen in: Radiological Physics and Technology | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Recently, region-setting computed tomography (CT) has been studied as a region of interest imaging method. This technique can strongly reduce the radiation dose by limiting the irradiation field. Although mathematical studies have been performed for reduction of the truncation artifact, no experimental studies have been performed so far. In this study, we developed a three-dimensional region-setting CT system and evaluated its imaging properties. As an experimental system, we developed an X-ray CT system with multileaf collimators. In this system, truncated projection data can be captured by limiting of the radiation field. In addition, a truncated projection data correction was performed. Finally, image reconstruction was performed by use of the Feldkamp–Davis–Kress algorithm. In the experiments, the line profiles and the image quality of the reconstructed images were evaluated. The results suggested that the image quality of the proposed method is comparable to that of the original method. Furthermore, we confirmed that the radiation dose was reduced when this system was used. These results indicate that a 3D region-setting CT system using 6-channel multileaf collimators can reduce the radiation dose without in causing a degradation of image quality.
Literatur
2.
Zurück zum Zitat Asada Y, Suzuki S, Kobayashi K, Kato H. Investigation of patient exposure doses in diagnostic radiography in 2011 questionnaire. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2013;69:371–9.CrossRefPubMed Asada Y, Suzuki S, Kobayashi K, Kato H. Investigation of patient exposure doses in diagnostic radiography in 2011 questionnaire. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2013;69:371–9.CrossRefPubMed
3.
Zurück zum Zitat de González A, Darby S. Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet. 2004;363:345–51.CrossRef de González A, Darby S. Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet. 2004;363:345–51.CrossRef
4.
Zurück zum Zitat Brenner D, Hall E. Computed tomography—an increasing source of radiation exposure. N Engl J Med. 2007;357:2277–84.CrossRefPubMed Brenner D, Hall E. Computed tomography—an increasing source of radiation exposure. N Engl J Med. 2007;357:2277–84.CrossRefPubMed
5.
Zurück zum Zitat Nguyen P, Lee W, Li Y, Hong W. Assessment of the radiation effects of cardiac CT angiography using protein and genetic biomarkers. JACC Cardiovasc Imaging. 2015;8:873–84.CrossRefPubMedPubMedCentral Nguyen P, Lee W, Li Y, Hong W. Assessment of the radiation effects of cardiac CT angiography using protein and genetic biomarkers. JACC Cardiovasc Imaging. 2015;8:873–84.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Silva A, Lawder H, Hara A. Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol. 2010;194:191–9.CrossRefPubMed Silva A, Lawder H, Hara A. Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol. 2010;194:191–9.CrossRefPubMed
7.
Zurück zum Zitat Xia Y, Dennerlein F, Bauer S. Scaling calibration in region of interest reconstruction with the 1D and 2D ATRACT algorithm. Int J Comput Assist Radiol Surg. 2014;9:345–56.CrossRefPubMed Xia Y, Dennerlein F, Bauer S. Scaling calibration in region of interest reconstruction with the 1D and 2D ATRACT algorithm. Int J Comput Assist Radiol Surg. 2014;9:345–56.CrossRefPubMed
8.
Zurück zum Zitat Seger MM. Rampfilter implementation on truncated projection data. Application to 3D linear tomography for logs. In: proc. SSAB02 symp. image anal. 2002. p. 33–36. Seger MM. Rampfilter implementation on truncated projection data. Application to 3D linear tomography for logs. In: proc. SSAB02 symp. image anal. 2002. p. 33–36.
9.
Zurück zum Zitat Ohnesorge B, Flohr T, Schwarz K, Heiken J, Bae K. Efficient correction for CT image artifacts caused by objects extending outside the scan field of view. Med Phys. 2000;27:39–46.CrossRefPubMed Ohnesorge B, Flohr T, Schwarz K, Heiken J, Bae K. Efficient correction for CT image artifacts caused by objects extending outside the scan field of view. Med Phys. 2000;27:39–46.CrossRefPubMed
10.
Zurück zum Zitat Noo F, Clackdoyle R, Pack J. A two-step Hilbert transform method for 2D image reconstruction. Phys Med Biol. 2004;49:3903–23.CrossRefPubMed Noo F, Clackdoyle R, Pack J. A two-step Hilbert transform method for 2D image reconstruction. Phys Med Biol. 2004;49:3903–23.CrossRefPubMed
11.
Zurück zum Zitat Kudo H, Courdurier M, Noo F, Defrise M. Tiny a priori knowledge solves the interior problem in computed tomography. Phys Med Biol. 2008;53:2207–31.CrossRefPubMed Kudo H, Courdurier M, Noo F, Defrise M. Tiny a priori knowledge solves the interior problem in computed tomography. Phys Med Biol. 2008;53:2207–31.CrossRefPubMed
12.
Zurück zum Zitat Gong H, Lu J, Zhou O, Cao G. Implementation of interior micro-CT on a carbon nanotube dynamic micro-CT scanner for lower radiation dose. In: proc SPIE med. imaging. int. soc. opt. photonics. 2015. p. 94124N–94124N–9. Gong H, Lu J, Zhou O, Cao G. Implementation of interior micro-CT on a carbon nanotube dynamic micro-CT scanner for lower radiation dose. In: proc SPIE med. imaging. int. soc. opt. photonics. 2015. p. 94124N–94124N–9.
13.
Zurück zum Zitat Natterer F. The mathematics of computerized tomography. New York: Siam; 1986. p. 158–79. Natterer F. The mathematics of computerized tomography. New York: Siam; 1986. p. 158–79.
14.
Zurück zum Zitat Hashimoto F, Teramoto A, Asada Y, Suzuki S, Fujita H. Development of the two-dimensional region-setting CT system: development and basic evaluation of the experimental system using the active collimators. Med Imaging Technol. 2016;34:123–7. Hashimoto F, Teramoto A, Asada Y, Suzuki S, Fujita H. Development of the two-dimensional region-setting CT system: development and basic evaluation of the experimental system using the active collimators. Med Imaging Technol. 2016;34:123–7.
15.
Zurück zum Zitat Shepp L, Kruskal J. Computerized tomography: the new medical X-ray technology. Am Math Mon. 1978;85:420–39.CrossRef Shepp L, Kruskal J. Computerized tomography: the new medical X-ray technology. Am Math Mon. 1978;85:420–39.CrossRef
16.
Zurück zum Zitat Feldkamp L, Davis L, Kress J. Practical cone-beam algorithm. J Opt Soc Am A. 1984;1:612–9.CrossRef Feldkamp L, Davis L, Kress J. Practical cone-beam algorithm. J Opt Soc Am A. 1984;1:612–9.CrossRef
17.
Zurück zum Zitat Penney BC. Constrained least-squares restoration of nuclear medicine images: selecting the coarseness function. Med Phys. 1987;14:849–58.CrossRefPubMed Penney BC. Constrained least-squares restoration of nuclear medicine images: selecting the coarseness function. Med Phys. 1987;14:849–58.CrossRefPubMed
Metadaten
Titel
Dose reduction technique in diagnostic X-ray computed tomography by use of 6-channel multileaf collimators
verfasst von
Fumio Hashimoto
Atsushi Teramoto
Yasuki Asada
Shoichi Suzuki
Hiroshi Fujita
Publikationsdatum
01.03.2017
Verlag
Springer Japan
Erschienen in
Radiological Physics and Technology / Ausgabe 1/2017
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-016-0368-z

Weitere Artikel der Ausgabe 1/2017

Radiological Physics and Technology 1/2017 Zur Ausgabe

PET kann infarktgefährdete Koronararterien entdecken

04.06.2024 Koronare Herzerkrankung Nachrichten

Der Nachweis aktiver Plaques mittels 18F-Natriumfluorid-PET hilft nicht nur, infarktgefährdete Patienten, sondern auch infarktgefährdete Koronararterien zu erkennen. Von einer gezielten Behandlung vulnerabler Plaques ist man trotzdem weit entfernt.

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.