Skip to main content
Erschienen in: European Archives of Oto-Rhino-Laryngology 6/2009

01.06.2009 | Otology

Effect of cochlear implantation on horizontal semicircular canal function

verfasst von: Eike Krause, Julia P. R. Louza, John-Martin Hempel, Juliane Wechtenbruch, Tobias Rader, Robert Gürkov

Erschienen in: European Archives of Oto-Rhino-Laryngology | Ausgabe 6/2009

Einloggen, um Zugang zu erhalten

Abstract

The objective of this study was to assess the influence of a cochlear implant (CI) on horizontal semicircular canal (hSCC) function, to test the correlation with symptomatic vertigo and to identify possible risk factors for a postoperative vestibular impairment. In a prospective observational study design, forty-seven adult patients who had undergone cochlear implantation at Cochlear Implant Center at a tertiary referral university hospital, Munich, between 2003 and 2007, were studied. Postoperative vertigo symptoms were assessed using a questionnaire followed by a structured interview. Patients were subjected to caloric and rotational chair vestibular function tests pre- and postoperatively. The CI operation was performed with a retroauricular transmastoidal approach by three different surgeons. Thirty-six implants were Cochlear Nucleus 24 devices and 11 implants were MedEl devices. Twenty-one (45%) patients reported vertigo symptoms after CI. Functional testing of the hSCC yielded valid results in 45 of the 47 patients. Thirty-two percent of patients had a substantially reduced hSCC function after CI. Responses of caloric irrigation showed a significant worsening postoperatively in the CI ears. No direct correlation between a decrease in caloric response and risk of postoperative vertigo symptoms could be established. For the criteria age, sex, implant type, surgeon, cause of deafness, petrous bone CT findings and preoperative vertigo, there were no significant differences between the patients with and the patients without postoperative vertigo. Besides morphological changes, a cochlear implantation also causes functional damage of vestibular parts of the labyrinth. Our study showed a significant worsening of the caloric response. However, this alteration did not lead to vertigo complaints in all patients. It is therefore presumed that additional damage to sensory or visual afferents and central vestibular compensatory mechanisms play a role.
Literatur
9.
Zurück zum Zitat Jongkees LB, Maas JP, Philipszoon AJ (1962) Clinical nystagmography. A detailed study of electro-nystagmography in 341 patients with vertigo. Pract Otorhinolaryngol (Basel) 24:65–93 Jongkees LB, Maas JP, Philipszoon AJ (1962) Clinical nystagmography. A detailed study of electro-nystagmography in 341 patients with vertigo. Pract Otorhinolaryngol (Basel) 24:65–93
12.
Zurück zum Zitat Mulch G, Leonardy B, Petermann W (1978) Normal values of the caloric test. Laryngol Rhinol Otol (Stuttg) 57(6):528–540 Mulch G, Leonardy B, Petermann W (1978) Normal values of the caloric test. Laryngol Rhinol Otol (Stuttg) 57(6):528–540
13.
Zurück zum Zitat O’Leary MJ, Fayad J, House WF, Linthicum FH Jr (1991) Electrode insertion trauma in cochlear implantation. Ann Otol Rhinol Laryngol 100:695–699PubMed O’Leary MJ, Fayad J, House WF, Linthicum FH Jr (1991) Electrode insertion trauma in cochlear implantation. Ann Otol Rhinol Laryngol 100:695–699PubMed
14.
Zurück zum Zitat Mangham CA (1987) Effects of cochlear prostheses on vestibulo-ocular reflexes to rotation. Ann Otol Rhinol Laryngol Suppl 128:101–104 Mangham CA (1987) Effects of cochlear prostheses on vestibulo-ocular reflexes to rotation. Ann Otol Rhinol Laryngol Suppl 128:101–104
15.
Zurück zum Zitat Cohen NL, Hoffman RA (1991) Complications of cochlear implant surgery in adults and children. Ann Otol Rhinol Laryngol 100:708–711PubMed Cohen NL, Hoffman RA (1991) Complications of cochlear implant surgery in adults and children. Ann Otol Rhinol Laryngol 100:708–711PubMed
17.
Zurück zum Zitat Graham SS, Dickins JR (1995) Postimplantation Meniere’s syndrome with fluctuant electrical thresholds. Ann Otol Rhinol Laryngol Suppl 166:412–414PubMed Graham SS, Dickins JR (1995) Postimplantation Meniere’s syndrome with fluctuant electrical thresholds. Ann Otol Rhinol Laryngol Suppl 166:412–414PubMed
Metadaten
Titel
Effect of cochlear implantation on horizontal semicircular canal function
verfasst von
Eike Krause
Julia P. R. Louza
John-Martin Hempel
Juliane Wechtenbruch
Tobias Rader
Robert Gürkov
Publikationsdatum
01.06.2009
Verlag
Springer-Verlag
Erschienen in
European Archives of Oto-Rhino-Laryngology / Ausgabe 6/2009
Print ISSN: 0937-4477
Elektronische ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-008-0815-5

Weitere Artikel der Ausgabe 6/2009

European Archives of Oto-Rhino-Laryngology 6/2009 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

HNO-Op. auch mit über 90?

16.04.2024 HNO-Chirurgie Nachrichten

Mit Blick auf das Risiko für Komplikationen nach elektiven Eingriffen im HNO-Bereich scheint das Alter der Patienten kein ausschlaggebender Faktor zu sein. Entscheidend ist offenbar, wie fit die Betroffenen tatsächlich sind.

Intrakapsuläre Tonsillektomie gewinnt an Boden

16.04.2024 Tonsillektomie Nachrichten

Gegenüber der vollständigen Entfernung der Gaumenmandeln hat die intrakapsuläre Tonsillektomie einige Vorteile, wie HNO-Fachleute aus den USA hervorheben. Sie haben die aktuelle Literatur zu dem Verfahren gesichtet.

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.