Erschienen in: Lasers in Medical Science 2/2018

27.10.2017 | Original Article

Effect of different power settings of Er,Cr:YSGG laser before or after tribosilicatization on the microshear bond strength between zirconia and two types of cements

verfasst von: Leonardo C. Zeidan, Camila M. Esteves, Juliana A. Oliveira, Aldo Brugnera Jr, Alessandra Cassoni, José Augusto Rodrigues

Erschienen in: Lasers in Medical Science | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to evaluate the effect of different output powers of Er,Cr:YSGG laser and the association with tribochemical silica coating on the bond strength between zirconia ceramic and two resin cements. One hundred ninety-two zirconia ceramic bars (IPS e-max ZirCAD Ivoclar Vivadent-) were sectioned (6 × 6 × 4 mm), sintered, and randomly divided into 12 groups for each cement system according to the surface treatment (n = 8): C—without treatment (control); R—tribochemical coating + resin cement (control); 2L—laser (2.0 W) + resin cement; 2LR—laser (2.0 W) + tribochemical coating + resin cement; R2L—tribochemical coating + laser (2.0 W) + resin cement; 2.5L—laser (2.5 W) + resin cement; 2.5LR—laser (2.5 W) + tribochemical coating + resin cement; R2.5L—tribochemical coating + laser (2.5 W) + resin cement; 3L—laser (3.0 W) + resin cement; 3LR—laser (3.0 W) + tribochemical coating + resin cement, R3L—tribochemical coating + laser (3.0 W) + resin cement; and RPHO—tribochemical + resin cement + photoactivation (control). After the surface treatment, the respective primers were applied, and resin cements, Multilink N, Ivoclar Vivadent (M), and Panavia F 2.0, Kuraray Medical Inc. (P), were inserted into Tygon molds which were bonded to the zirconia bars. Each specimen received two cements bars. After 24 h of storage in a relative humidity (100%) at 37 °C, they were evaluated by the microshear test speed of 1 mm/min. The microshear values were analyzed by one-way ANOVA and Tukey’s test (α = 0.05). ANOVA showed statistically significant differences among the evaluated groups. The highest bond strength was observed in RPHO, which statistically differed from all groups. The lowest bond strength was observed in M2.5L (Multilink N) and in P3LR (Panavia F 2.0). It can be concluded that the lowest power output tested was suitable and showed bond strength values similar to tribochemical silica deposition. The light curing is important to adhesion and the tribosilicatizated surface achieves similar microshear values to untreated surface in absence of light.
Literatur
1.
Zurück zum Zitat Denry I, Kelly JR (2008) State of the art of zirconia for dental applications. Dent Mater 24:299–307CrossRefPubMed Denry I, Kelly JR (2008) State of the art of zirconia for dental applications. Dent Mater 24:299–307CrossRefPubMed
2.
Zurück zum Zitat Tinschert J, Zwez D, Marx R, Anusavice KJ (2000) Structural reliability of alumina, feldspar, leucite-, mica- and zirconia-based ceramics. J Dent 28:529–535CrossRefPubMed Tinschert J, Zwez D, Marx R, Anusavice KJ (2000) Structural reliability of alumina, feldspar, leucite-, mica- and zirconia-based ceramics. J Dent 28:529–535CrossRefPubMed
3.
Zurück zum Zitat de Castro HL, Corazza PH, Paes-Júnior TA, Della Bona A (2012) Influence of Y-TZP ceramic treatment and different resin cements on bond strength to dentin. Dent Mater 28:1191–1197CrossRefPubMed de Castro HL, Corazza PH, Paes-Júnior TA, Della Bona A (2012) Influence of Y-TZP ceramic treatment and different resin cements on bond strength to dentin. Dent Mater 28:1191–1197CrossRefPubMed
4.
5.
Zurück zum Zitat Wolfart M, Lehmann F, Wolfart S, & Kern M (2007) Durability of the resin bond strength to zirconia ceramic after using different surface conditioning methods. Dent Mater 2008; 23:45–50 Wolfart M, Lehmann F, Wolfart S, & Kern M (2007) Durability of the resin bond strength to zirconia ceramic after using different surface conditioning methods. Dent Mater 2008; 23:45–50
6.
Zurück zum Zitat Koizumi H, Nakayama D, Komine F, Blatz MB, Matsumura H (2012) Bonding of resin-based luting cements to zirconia with and without the use of ceramic priming agents. J Adhes Dent 14:385–392PubMed Koizumi H, Nakayama D, Komine F, Blatz MB, Matsumura H (2012) Bonding of resin-based luting cements to zirconia with and without the use of ceramic priming agents. J Adhes Dent 14:385–392PubMed
7.
Zurück zum Zitat Albino LG, Gradinar O, Rodrigues JA (2011) Esthetic rehabilitation of anterior teeth with porcelain crowns reinforced with zirconia cores. Gen Dent 59:e1–e6PubMed Albino LG, Gradinar O, Rodrigues JA (2011) Esthetic rehabilitation of anterior teeth with porcelain crowns reinforced with zirconia cores. Gen Dent 59:e1–e6PubMed
8.
Zurück zum Zitat Subaşı MG, İnan Ö (2012) Evaluation of the topographical surface changes and roughness of zirconia after different surface treatments. Lasers Med Sci 27:735–742CrossRefPubMed Subaşı MG, İnan Ö (2012) Evaluation of the topographical surface changes and roughness of zirconia after different surface treatments. Lasers Med Sci 27:735–742CrossRefPubMed
9.
Zurück zum Zitat Koutayas SO, Vagkopoulou T, Pelekanos S, Koidis P, Strub JR (2009) Zirconia in dentistry: part 2. Evidence-based clinical breakthrough. Eur J Esthet Dent 4:348–380PubMed Koutayas SO, Vagkopoulou T, Pelekanos S, Koidis P, Strub JR (2009) Zirconia in dentistry: part 2. Evidence-based clinical breakthrough. Eur J Esthet Dent 4:348–380PubMed
10.
Zurück zum Zitat Palacios RP, Johnson GH, Phillips KM, Raigrodski AJ (2006) Retention of zirconium oxide ceramic crowns with three types of cement. J Prosthet Dent 96:104–114CrossRefPubMed Palacios RP, Johnson GH, Phillips KM, Raigrodski AJ (2006) Retention of zirconium oxide ceramic crowns with three types of cement. J Prosthet Dent 96:104–114CrossRefPubMed
11.
Zurück zum Zitat Aras WMF, Barroso JSM, Blay A, Rodrigues JA, Cassoni A (2016) Er,Cr:YSGG laser irradiation influence on Y-TZP bond strength to resin cement. Int Ceramics 42:13790–95 Aras WMF, Barroso JSM, Blay A, Rodrigues JA, Cassoni A (2016) Er,Cr:YSGG laser irradiation influence on Y-TZP bond strength to resin cement. Int Ceramics 42:13790–95
12.
Zurück zum Zitat Piascik JR, Swift EJ, Thompson JY, Grego S, Stoner BR (2009) Surface modification for enhanced silanation of zirconia ceramics. Dent Mater 25:1116–1121CrossRefPubMedPubMedCentral Piascik JR, Swift EJ, Thompson JY, Grego S, Stoner BR (2009) Surface modification for enhanced silanation of zirconia ceramics. Dent Mater 25:1116–1121CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Casucci A, Mazzitelli C, Monticelli F, Toledano M, Osorio R, Osorio E, Papacchini F, Ferrari M (2010) Morphological analysis of three zirconium oxide ceramics: effect of surface treatments. Dent Mater 26:751–760CrossRefPubMed Casucci A, Mazzitelli C, Monticelli F, Toledano M, Osorio R, Osorio E, Papacchini F, Ferrari M (2010) Morphological analysis of three zirconium oxide ceramics: effect of surface treatments. Dent Mater 26:751–760CrossRefPubMed
14.
Zurück zum Zitat Al-Harbi FA, Ayad NM, Khan ZA, Mahrous AA, Morgano SM (2016) In vitro shear bond strength of Y-TZP ceramics to different core materials with the use of three primer/resin cement systems. J Prosthet Dent 115:84–89CrossRefPubMed Al-Harbi FA, Ayad NM, Khan ZA, Mahrous AA, Morgano SM (2016) In vitro shear bond strength of Y-TZP ceramics to different core materials with the use of three primer/resin cement systems. J Prosthet Dent 115:84–89CrossRefPubMed
15.
Zurück zum Zitat Cavalcanti AN, Pilecki P, Foxton RM, Watson TF, Oliveira MT, Gianinni M, Marchi GM (2009) Evaluation of the surface roughness and morphologic features of Y-TZP ceramics after different surface treatments. Photomed Laser Surg 27:473–479CrossRefPubMed Cavalcanti AN, Pilecki P, Foxton RM, Watson TF, Oliveira MT, Gianinni M, Marchi GM (2009) Evaluation of the surface roughness and morphologic features of Y-TZP ceramics after different surface treatments. Photomed Laser Surg 27:473–479CrossRefPubMed
16.
Zurück zum Zitat Paranhos MP, Burnett LH Jr, Magne P (2011) Effect of Nd:YAG laser and CO2 laser treatment on the resin bond strength to zirconia ceramic. Quintessence Int 42:79–89PubMed Paranhos MP, Burnett LH Jr, Magne P (2011) Effect of Nd:YAG laser and CO2 laser treatment on the resin bond strength to zirconia ceramic. Quintessence Int 42:79–89PubMed
17.
Zurück zum Zitat Tanış MÇ, Akçaboy C (2015) Effects of different surface treatment methods and MDP monomer on resin cementation of zirconia ceramics: an in vitro study. J Lasers Med Sci 6:174–181CrossRefPubMedPubMedCentral Tanış MÇ, Akçaboy C (2015) Effects of different surface treatment methods and MDP monomer on resin cementation of zirconia ceramics: an in vitro study. J Lasers Med Sci 6:174–181CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Kirmali O, Kustarci A, Kapdan A, Er K (2015) Efficacy of surface roughness and bond strength of Y-TZP zirconia after various pre-treatments. Photomed Laser Surg 33:15–21CrossRefPubMed Kirmali O, Kustarci A, Kapdan A, Er K (2015) Efficacy of surface roughness and bond strength of Y-TZP zirconia after various pre-treatments. Photomed Laser Surg 33:15–21CrossRefPubMed
19.
Zurück zum Zitat Ourique SA, Arrais CA, Cassoni A, Ota-Tsuzuki C, Rodrigues JA (2011) Effects of different concentrations of carbamide peroxide and bleaching periods on the roughness of dental ceramics. Braz Oral Res 25:453–458CrossRefPubMed Ourique SA, Arrais CA, Cassoni A, Ota-Tsuzuki C, Rodrigues JA (2011) Effects of different concentrations of carbamide peroxide and bleaching periods on the roughness of dental ceramics. Braz Oral Res 25:453–458CrossRefPubMed
20.
Zurück zum Zitat Foxton RM, Cavalcanti AN, Nakajima M, Pilecki P, Sherriff M, Melo L, Watson TF (2011) Durability of resin cement bond to aluminium oxide and zirconia ceramics after air abrasion and laser treatment. J Prosthodont 20:84–92CrossRefPubMed Foxton RM, Cavalcanti AN, Nakajima M, Pilecki P, Sherriff M, Melo L, Watson TF (2011) Durability of resin cement bond to aluminium oxide and zirconia ceramics after air abrasion and laser treatment. J Prosthodont 20:84–92CrossRefPubMed
21.
Zurück zum Zitat Della Bona A, Robert Kelly J (2009) The clinical success of all-ceramic restorations. JADA 139(suppl 4):8–13 Della Bona A, Robert Kelly J (2009) The clinical success of all-ceramic restorations. JADA 139(suppl 4):8–13
22.
Zurück zum Zitat Filser F, Kocher P, Weibel F (2004) Reliability and strength of all- ceramic dental restorations fabricated by direct ceramic machining (DCM). Int J Comput Dent 89-106 Filser F, Kocher P, Weibel F (2004) Reliability and strength of all- ceramic dental restorations fabricated by direct ceramic machining (DCM). Int J Comput Dent 89-106
23.
Zurück zum Zitat Guess C, Kulis A, Witkowskia S, Wolkewitz M, ZhangY SJR (2004) Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling. Dent Mater 24:1556–1567CrossRef Guess C, Kulis A, Witkowskia S, Wolkewitz M, ZhangY SJR (2004) Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling. Dent Mater 24:1556–1567CrossRef
24.
Zurück zum Zitat Papia E, Larsson C, du Toit M, Vult von S (2014) Bonding between oxide ceramics and adhesive cement systems: a systematic review. J Biomed Mater Res B Appl Biomater 102:395–413CrossRefPubMed Papia E, Larsson C, du Toit M, Vult von S (2014) Bonding between oxide ceramics and adhesive cement systems: a systematic review. J Biomed Mater Res B Appl Biomater 102:395–413CrossRefPubMed
25.
Zurück zum Zitat Subaşı MG, İnan Ö (2014) Influence of surface treatments and resin cement selection on bonding to zirconia. Lasers Med Sci 29:19–27CrossRefPubMed Subaşı MG, İnan Ö (2014) Influence of surface treatments and resin cement selection on bonding to zirconia. Lasers Med Sci 29:19–27CrossRefPubMed
26.
Zurück zum Zitat Ersu B, Yuzugullu B, Ruya Yazici A, Canay S (2009) Surface roughness and bond strengths of glass-infiltrated alumina- ceramics prepared using various surface treatments. J Dent 37:848–856CrossRefPubMed Ersu B, Yuzugullu B, Ruya Yazici A, Canay S (2009) Surface roughness and bond strengths of glass-infiltrated alumina- ceramics prepared using various surface treatments. J Dent 37:848–856CrossRefPubMed
27.
Zurück zum Zitat Akyil MS, Uzun IH, Bayindir F (2010) Bond strength of resin cement to yttrium-stabilized tetragonal zirconia ceramic treated with air abrasion, silica coating and laser irradiation. Photomed Laser Surg 28:801–808CrossRefPubMed Akyil MS, Uzun IH, Bayindir F (2010) Bond strength of resin cement to yttrium-stabilized tetragonal zirconia ceramic treated with air abrasion, silica coating and laser irradiation. Photomed Laser Surg 28:801–808CrossRefPubMed
28.
Zurück zum Zitat Flury S, Lussi A, Hickel R, Ilie N (2013) Light curing through glass ceramics with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements. Clin Oral Investig 17:2127–2137CrossRefPubMed Flury S, Lussi A, Hickel R, Ilie N (2013) Light curing through glass ceramics with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements. Clin Oral Investig 17:2127–2137CrossRefPubMed
29.
Zurück zum Zitat Kim MJ, Kim KH, Kim YK, Kwon TY (2013 Nov) Degree of conversion of two dual-cured resin cements light-irradiated through zirconia ceramic disks. J Adv Prosthodont. 5(4):464–470CrossRefPubMedPubMedCentral Kim MJ, Kim KH, Kim YK, Kwon TY (2013 Nov) Degree of conversion of two dual-cured resin cements light-irradiated through zirconia ceramic disks. J Adv Prosthodont. 5(4):464–470CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Gokce B, Ozpinar B, Dundar M (2007) Bond strengths of all-ceramics: acid vs laser etching. Oper Dent 32:173–178CrossRefPubMed Gokce B, Ozpinar B, Dundar M (2007) Bond strengths of all-ceramics: acid vs laser etching. Oper Dent 32:173–178CrossRefPubMed
31.
Zurück zum Zitat Spohr AM, Borges GA, Junior LH, Mota EG, Oshima HM (2008) Surface modification of In-Ceram Zirconia ceramic by Nd:YAG laser, Rocatec system, or aluminum oxide sandblasting and its bond strength to a resin cement. Photomed Laser Surg 26:203–208CrossRefPubMed Spohr AM, Borges GA, Junior LH, Mota EG, Oshima HM (2008) Surface modification of In-Ceram Zirconia ceramic by Nd:YAG laser, Rocatec system, or aluminum oxide sandblasting and its bond strength to a resin cement. Photomed Laser Surg 26:203–208CrossRefPubMed
32.
Zurück zum Zitat Ural C, Kulunk T, Kulunk S, Kurt M (2010) The effect of laser treatment on bonding between zirconia ceramic surface and resin cement. Acta Odontol Scand 68:354–359CrossRefPubMed Ural C, Kulunk T, Kulunk S, Kurt M (2010) The effect of laser treatment on bonding between zirconia ceramic surface and resin cement. Acta Odontol Scand 68:354–359CrossRefPubMed
33.
Zurück zum Zitat Kumbuloglu O, Lassila LV, User A, Vallittu PK (2006) Bonding of resin composite luting cements to zirconium oxide by two air-particle abrasion methods. Oper Dent 31:248–255CrossRefPubMed Kumbuloglu O, Lassila LV, User A, Vallittu PK (2006) Bonding of resin composite luting cements to zirconium oxide by two air-particle abrasion methods. Oper Dent 31:248–255CrossRefPubMed
34.
Zurück zum Zitat Kursoglu P, Motro PF, Yurdaguven H (2013) Shear bond strength of resin cement to an acid etched and a laser irradiated ceramic surface. J Adv Prosthodont 5:98–103CrossRefPubMedPubMedCentral Kursoglu P, Motro PF, Yurdaguven H (2013) Shear bond strength of resin cement to an acid etched and a laser irradiated ceramic surface. J Adv Prosthodont 5:98–103CrossRefPubMedPubMedCentral
35.
Zurück zum Zitat Ghasemi A, Kermanshah H, Ghavam M, Nateghifard A, Torabdazeh H, Nateghifard A, Zolfaghamasab AH (2014) Effect of Er,Cr:YSGG laser treatment on microshear bond strength of zirconia to resin cement before and after sintering. J Adhes Dent 16:377–382PubMed Ghasemi A, Kermanshah H, Ghavam M, Nateghifard A, Torabdazeh H, Nateghifard A, Zolfaghamasab AH (2014) Effect of Er,Cr:YSGG laser treatment on microshear bond strength of zirconia to resin cement before and after sintering. J Adhes Dent 16:377–382PubMed
Metadaten
Titel
Effect of different power settings of Er,Cr:YSGG laser before or after tribosilicatization on the microshear bond strength between zirconia and two types of cements
verfasst von
Leonardo C. Zeidan
Camila M. Esteves
Juliana A. Oliveira
Aldo Brugnera Jr
Alessandra Cassoni
José Augusto Rodrigues
Publikationsdatum
27.10.2017
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 2/2018
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-017-2343-2

Weitere Artikel der Ausgabe 2/2018

Lasers in Medical Science 2/2018 Zur Ausgabe