Skip to main content
Erschienen in: Hernia 1/2019

28.10.2018 | Original Article

Efficacy of robotic versus open transversus abdominis release in a porcine model

verfasst von: W. H. Tan, J. M. McAllister, J. A. Blatnik

Erschienen in: Hernia | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Transversus abdominis muscle release (TAR) combines retromuscular mesh placement with posterior component separation and muscle release. TAR is usually an open technique for abdominal wall reconstruction; however, several centers have performed this operation robotically and claim better clinical outcomes when compared to open surgery. We sought to compare robotic versus open TAR utilizing a porcine model.

Methods

Animals were randomized to open versus robotic TAR with mesh placement, survived for 4 weeks, then underwent diagnostic laparoscopy to assess adhesive burden and adhesion tenacity. T-peel testing was utilized to assess mesh ingrowth. The primary outcome was adhesive burden; secondary outcomes included mesh incorporation, contraction, and operative time.

Results

Nine robotic and eight open TARs were performed. Mean operative time was significantly shorter for the open cases compared to robotic cases (88.6 ± 12.9 min versus 228.3 ± 46.2, p < 0.01). Operative time in the robotic arm of the study decreased over time, from 300 to 165 min. No difference was seen in the mean adhesion area between the two groups. Adhesion tenacity and mesh flatness were similar. The work required to peel the mesh off surrounding tissue was significantly higher in the open TAR than in the robotic TAR group: 52.6 ± 15.5 and 32.9 ± 10.6 mJ/cm2, respectively (p < 0.01).

Conclusions

There were no differences in adhesions between the robotic and open approaches, but greater mesh contraction and ingrowth was observed in the open TAR group. Though operative time was longer in the robotic group, time dropped by about 40% from the first case to the last.
Literatur
1.
Zurück zum Zitat Novitsky YW, Elliott HL, Orenstein SB, Rosen MJ (2012) Transversus abdominis muscle release: a novel approach to posterior component separation during complex abdominal wall reconstruction. Am J Surg 204:709–716CrossRefPubMed Novitsky YW, Elliott HL, Orenstein SB, Rosen MJ (2012) Transversus abdominis muscle release: a novel approach to posterior component separation during complex abdominal wall reconstruction. Am J Surg 204:709–716CrossRefPubMed
2.
Zurück zum Zitat Novitsky YW, Fayezizadeh M, Majumder A, Neupane R, Elliott HL, Orenstein SB (2016) Outcomes of posterior component separation with transversus abdominis muscle release and synthetic mesh sublay reinforcement. Ann Surg 264:226–232CrossRefPubMed Novitsky YW, Fayezizadeh M, Majumder A, Neupane R, Elliott HL, Orenstein SB (2016) Outcomes of posterior component separation with transversus abdominis muscle release and synthetic mesh sublay reinforcement. Ann Surg 264:226–232CrossRefPubMed
3.
Zurück zum Zitat Deeken CR, Matthews BD (2012) Comparison of contracture, adhesion, tissue ingrowth, and histologic response characteristics of permanent and absorbable barrier meshes in a porcine model of laparoscopic ventral hernia repair. Hernia J Hernias Abdom Wall Surg 16:69–76CrossRef Deeken CR, Matthews BD (2012) Comparison of contracture, adhesion, tissue ingrowth, and histologic response characteristics of permanent and absorbable barrier meshes in a porcine model of laparoscopic ventral hernia repair. Hernia J Hernias Abdom Wall Surg 16:69–76CrossRef
4.
Zurück zum Zitat Lake SP, Ray S, Zihni AM, Thompson DM Jr, Gluckstein J, Deeken CR (2015) Pore size and pore shape—but not mesh density—alter the mechanical strength of tissue ingrowth and host tissue response to synthetic mesh materials in a porcine model of ventral hernia repair. J Mech Behav Biomed Mater 42:186–197CrossRefPubMed Lake SP, Ray S, Zihni AM, Thompson DM Jr, Gluckstein J, Deeken CR (2015) Pore size and pore shape—but not mesh density—alter the mechanical strength of tissue ingrowth and host tissue response to synthetic mesh materials in a porcine model of ventral hernia repair. J Mech Behav Biomed Mater 42:186–197CrossRefPubMed
5.
Zurück zum Zitat Einarsson JI, Grazul-Bilska AT, Vonnahme KA (2011) Barbed vs standard suture: randomized single-blinded comparison of adhesion formation and ease of use in an animal model. J Minim Invasive Gynecol 18:716–719CrossRefPubMed Einarsson JI, Grazul-Bilska AT, Vonnahme KA (2011) Barbed vs standard suture: randomized single-blinded comparison of adhesion formation and ease of use in an animal model. J Minim Invasive Gynecol 18:716–719CrossRefPubMed
6.
Zurück zum Zitat Api M, Cikman MS, Boza A, Rabus MB, Onenerk M, Aker FV (2015) Peritoneal closure over barbed suture to prevent adhesions: a randomized controlled trial in an animal model. J Minim Invasive Gynecol 22:619–625CrossRefPubMed Api M, Cikman MS, Boza A, Rabus MB, Onenerk M, Aker FV (2015) Peritoneal closure over barbed suture to prevent adhesions: a randomized controlled trial in an animal model. J Minim Invasive Gynecol 22:619–625CrossRefPubMed
7.
Zurück zum Zitat Silvestre AC, de Mathia GB, Fagundes DJ, Medeiros LR, Rosa MI (2011) Shrinkage evaluation of heavyweight and lightweight polypropylene meshes in inguinal hernia repair: a randomized controlled trial. Hernia J Hernias Abdom Wall Surg 15:629–634CrossRef Silvestre AC, de Mathia GB, Fagundes DJ, Medeiros LR, Rosa MI (2011) Shrinkage evaluation of heavyweight and lightweight polypropylene meshes in inguinal hernia repair: a randomized controlled trial. Hernia J Hernias Abdom Wall Surg 15:629–634CrossRef
8.
Zurück zum Zitat Rogmark P, Ekberg O, Montgomery A (2017) Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature. Hernia J Hernias Abdom Wall Surg 21:687–696CrossRef Rogmark P, Ekberg O, Montgomery A (2017) Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature. Hernia J Hernias Abdom Wall Surg 21:687–696CrossRef
9.
Zurück zum Zitat Beldi G, Wagner M, Bruegger LE, Kurmann A, Candinas D (2011) Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation. Surg Endosc 25:749–755CrossRefPubMed Beldi G, Wagner M, Bruegger LE, Kurmann A, Candinas D (2011) Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation. Surg Endosc 25:749–755CrossRefPubMed
10.
Zurück zum Zitat Amid PK (1997) Classification of biomaterials and their related complications in abdominal wall hernia surgery. Hernia J Hernias Abdom Wall Surg 1:15–21CrossRef Amid PK (1997) Classification of biomaterials and their related complications in abdominal wall hernia surgery. Hernia J Hernias Abdom Wall Surg 1:15–21CrossRef
11.
Zurück zum Zitat Pierce RA, Perrone JM, Nimeri A, Sexton JA, Walcutt J, Frisella MM, Matthews BD (2009) 120-day comparative analysis of adhesion grade and quantity, mesh contraction, and tissue response to a novel omega-3 fatty acid bioabsorbable barrier macroporous mesh after intraperitoneal placement. Surg Innov 16:46–54CrossRefPubMed Pierce RA, Perrone JM, Nimeri A, Sexton JA, Walcutt J, Frisella MM, Matthews BD (2009) 120-day comparative analysis of adhesion grade and quantity, mesh contraction, and tissue response to a novel omega-3 fatty acid bioabsorbable barrier macroporous mesh after intraperitoneal placement. Surg Innov 16:46–54CrossRefPubMed
12.
Zurück zum Zitat Klinge U, Klosterhalfen B, Muller M, Ottinger AP, Schumpelick V (1998) Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 164:965–969CrossRefPubMed Klinge U, Klosterhalfen B, Muller M, Ottinger AP, Schumpelick V (1998) Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 164:965–969CrossRefPubMed
13.
Zurück zum Zitat Gonzalez R, Fugate K, McClusky D 3rd, Ritter EM, Lederman A, Dillehay D, Smith CD, Ramshaw BJ (2005) Relationship between tissue ingrowth and mesh contraction. World J Surg 29:1038–1043CrossRefPubMed Gonzalez R, Fugate K, McClusky D 3rd, Ritter EM, Lederman A, Dillehay D, Smith CD, Ramshaw BJ (2005) Relationship between tissue ingrowth and mesh contraction. World J Surg 29:1038–1043CrossRefPubMed
14.
Zurück zum Zitat Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11CrossRefPubMed Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11CrossRefPubMed
15.
Zurück zum Zitat Weyhe D, Cobb W, Lecuivre J, Alves A, Ladet S, Lomanto D, Bayon Y (2015) Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage—systematic analysis of key parameters of meshes in a novel minipig hernia model. Int J Surg (Lond Engl) 22:46–53CrossRef Weyhe D, Cobb W, Lecuivre J, Alves A, Ladet S, Lomanto D, Bayon Y (2015) Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage—systematic analysis of key parameters of meshes in a novel minipig hernia model. Int J Surg (Lond Engl) 22:46–53CrossRef
16.
Zurück zum Zitat Mantoo S, Rigaud J, Naulet S, Lehur PA, Meurette G (2014) Standardized surgical technique and dedicated operating room environment can reduce the operative time during robotic-assisted surgery for pelvic floor disorders. J Robot Surg 8:7–12CrossRefPubMed Mantoo S, Rigaud J, Naulet S, Lehur PA, Meurette G (2014) Standardized surgical technique and dedicated operating room environment can reduce the operative time during robotic-assisted surgery for pelvic floor disorders. J Robot Surg 8:7–12CrossRefPubMed
18.
Zurück zum Zitat Bittner JG, Alrefai S, Vy M, Mabe M, Del Prado PAR, Clingempeel NL (2018) Comparative analysis of open and robotic transversus abdominis release for ventral hernia repair. Surg Endosc 32:727–734CrossRefPubMed Bittner JG, Alrefai S, Vy M, Mabe M, Del Prado PAR, Clingempeel NL (2018) Comparative analysis of open and robotic transversus abdominis release for ventral hernia repair. Surg Endosc 32:727–734CrossRefPubMed
19.
Zurück zum Zitat Martin-Del-Campo LA, Weltz AS, Belyansky I, Novitsky YW (2018) Comparative analysis of perioperative outcomes of robotic versus open transversus abdominis release. Surg Endosc 32:840–845CrossRefPubMed Martin-Del-Campo LA, Weltz AS, Belyansky I, Novitsky YW (2018) Comparative analysis of perioperative outcomes of robotic versus open transversus abdominis release. Surg Endosc 32:840–845CrossRefPubMed
Metadaten
Titel
Efficacy of robotic versus open transversus abdominis release in a porcine model
verfasst von
W. H. Tan
J. M. McAllister
J. A. Blatnik
Publikationsdatum
28.10.2018
Verlag
Springer Paris
Erschienen in
Hernia / Ausgabe 1/2019
Print ISSN: 1265-4906
Elektronische ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-018-1836-7

Weitere Artikel der Ausgabe 1/2019

Hernia 1/2019 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.