Skip to main content
Erschienen in: Journal of Digital Imaging 4/2006

01.12.2006

Evaluation of the Image Quality of Temporal Subtraction Images Produced Automatically in a PACS Environment

verfasst von: Shuji Sakai, M.D., Ph.D., Hiroyasu Soeda, M.D., Akio Furuya, M.D., Hidetake Yabuuchi, M.D., Ph.D., Takashi Okafuji, M.D., Keiji Yamamoto, B.S., Hiroshi Honda, M.D., Ph.D., Kunio Doi, Ph.D.

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 4/2006

Einloggen, um Zugang zu erhalten

Abstract

The aim of the study is to evaluate the reliable production of temporal subtraction images in a picture archiving and communication system environment and to establish objective criteria for the evaluation of image quality. A total of 117 temporal subtraction chest images (55 in the upright position, 62 in the supine position) were obtained in five consecutive days. In all of these, we confirmed that there were no interval changes on the original images, and cases with diffuse lung disease were excluded. The temporal subtraction images were classified by three chest radiologists into five levels: 5, excellent; 4, good; 3, acceptable; 2, poor; and 1, very poor. The following were examined: (1) the yield of adequate quality of the temporal subtraction images; (2) whether the temporal subtraction images were obtained in the warping or nonwarping mode; and (3) the correlation of the overall subjective image quality with the relative shift angles, relative shift distances, and the standard deviation of gray levels in the temporal subtraction images. The percentages of acceptable temporal subtraction images were 100% and 66% in the upright and supine positions, respectively. Sixteen (26%) of the 62 supine-position images were made in nonwarping mode, whereas all upright images were made in warping mode. Significant correlations were obtained in the relative shift angle (P < 0.05), relative horizontal shift distance (P < 0.05), and standard deviation of gray levels (P < 0.0001). Temporal subtraction images with acceptable image quality were obtained in the upright position. The objective criteria may be useful for the evaluation of image quality.
Literatur
1.
Zurück zum Zitat Warren Burhenne, LJ, Wood, SA, D'Orsi, CJ, et al. 2000Potential contribution of computer-aided detection to the sensitivity of screening mammographyRadiology215554562PubMed Warren Burhenne, LJ, Wood, SA, D'Orsi, CJ,  et al. 2000Potential contribution of computer-aided detection to the sensitivity of screening mammographyRadiology215554562PubMed
2.
Zurück zum Zitat Nawano, S, Murakami, K, Moriyama, N, et al. 1999Computer-aided diagnosis in full digital mammographyInvest Radiol34310316CrossRefPubMed Nawano, S, Murakami, K, Moriyama, N,  et al. 1999Computer-aided diagnosis in full digital mammographyInvest Radiol34310316CrossRefPubMed
3.
Zurück zum Zitat Tsubamoto, M, Johkoh, T, Kozuka, T, et al. 2002Temporal subtraction for the detection of hazy pulmonary opacities on chest radiographyAJR179467471PubMed Tsubamoto, M, Johkoh, T, Kozuka, T,  et al. 2002Temporal subtraction for the detection of hazy pulmonary opacities on chest radiographyAJR179467471PubMed
4.
Zurück zum Zitat Morishita, J, Katsuragawa, S, Kondo, K, et al. 2001An automated patient recognition method based on an image-matching technique using previous chest radiographs in the picture archiving and communication system environmentMed Phys2810931097PubMedCrossRef Morishita, J, Katsuragawa, S, Kondo, K,  et al. 2001An automated patient recognition method based on an image-matching technique using previous chest radiographs in the picture archiving and communication system environmentMed Phys2810931097PubMedCrossRef
5.
Zurück zum Zitat Kano, A, Doi, K, MacMahon, H, et al. 1994Digital image subtraction of temporally sequential chest images for detection of interval changeMed Phys21453461CrossRefPubMed Kano, A, Doi, K, MacMahon, H,  et al. 1994Digital image subtraction of temporally sequential chest images for detection of interval changeMed Phys21453461CrossRefPubMed
6.
Zurück zum Zitat Shiraishi, J, Katsuragawa, S, Ikezoe, J, et al. 2000Development of a digital image database for chest radiographs with and without a lung nodule: receiver operating characteristic analysis of radiologists' detection of pulmonary nodulesAJR1747174PubMed Shiraishi, J, Katsuragawa, S, Ikezoe, J,  et al. 2000Development of a digital image database for chest radiographs with and without a lung nodule: receiver operating characteristic analysis of radiologists' detection of pulmonary nodulesAJR1747174PubMed
7.
Zurück zum Zitat Johkoh, T, Kozuka, T, Tomiyama, N, et al. 2002Temporal subtraction for detection of solitary pulmonary nodules on chest radiographs: evaluation of a commercially available computer-aided diagnosis systemRadiology223806811PubMed Johkoh, T, Kozuka, T, Tomiyama, N,  et al. 2002Temporal subtraction for detection of solitary pulmonary nodules on chest radiographs: evaluation of a commercially available computer-aided diagnosis systemRadiology223806811PubMed
8.
Zurück zum Zitat Kakeda, S, Nakamura, K, Kamada, K, et al. 2002Improved detection of lung nodules by using a temporal subtraction techniqueRadiology224145151PubMed Kakeda, S, Nakamura, K, Kamada, K,  et al. 2002Improved detection of lung nodules by using a temporal subtraction techniqueRadiology224145151PubMed
9.
Zurück zum Zitat Katsuragawa, S, Tagashira, H, Li, Q, et al. 1999Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiographyJ Digit Imaging12166172PubMedCrossRef Katsuragawa, S, Tagashira, H, Li, Q,  et al. 1999Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiographyJ Digit Imaging12166172PubMedCrossRef
10.
Zurück zum Zitat Weatherburn, GC, Ridout, D, Strickland, NH, et al. 2003A comparison of conventional film, CR hard copy and PACS soft copy images of the chest: analyses of ROC curves and inter-observer agreementEur J Radiol47206214CrossRefPubMed Weatherburn, GC, Ridout, D, Strickland, NH,  et al. 2003A comparison of conventional film, CR hard copy and PACS soft copy images of the chest: analyses of ROC curves and inter-observer agreementEur J Radiol47206214CrossRefPubMed
11.
Zurück zum Zitat Balassy, C, Prokop, M, Weber, M, Sailer, J, Herold, CJ, Schaefer-Prokop, C 2005Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: an observer performance studyAJR184752756PubMed Balassy, C, Prokop, M, Weber, M, Sailer, J, Herold, CJ, Schaefer-Prokop, C 2005Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: an observer performance studyAJR184752756PubMed
12.
Zurück zum Zitat Kanazawa, K, Kawata, Y, Niki, N, et al. 1998Computer-aided diagnosis for pulmonary nodules based on helical CT imagesComput Med Imaging Graph22157167CrossRefPubMed Kanazawa, K, Kawata, Y, Niki, N,  et al. 1998Computer-aided diagnosis for pulmonary nodules based on helical CT imagesComput Med Imaging Graph22157167CrossRefPubMed
13.
Zurück zum Zitat Yoshida, H, Masutani, Y, MacEneaney, P, et al. 2002Computerized detection of colonic polyps at CT colonography on the basis of volumetric features: pilot studyRadiology222327336PubMed Yoshida, H, Masutani, Y, MacEneaney, P,  et al. 2002Computerized detection of colonic polyps at CT colonography on the basis of volumetric features: pilot studyRadiology222327336PubMed
14.
15.
Zurück zum Zitat Rill, LN, Brateman, L, Arreola, M 2003Evaluating radiographic parameters for mobile chest computed radiography: phantoms, image quality and effective doseMed Phys3027272735CrossRefPubMed Rill, LN, Brateman, L, Arreola, M 2003Evaluating radiographic parameters for mobile chest computed radiography: phantoms, image quality and effective doseMed Phys3027272735CrossRefPubMed
16.
Zurück zum Zitat Roehrig, H, Krupinski, AE, Chawla, SA, Fan, J, Gandhi, K 2003Spatial noise and threshold contrasts in LCD displaysProc SPIE5034174186 Roehrig, H, Krupinski, AE, Chawla, SA, Fan, J, Gandhi, K 2003Spatial noise and threshold contrasts in LCD displaysProc SPIE5034174186
Metadaten
Titel
Evaluation of the Image Quality of Temporal Subtraction Images Produced Automatically in a PACS Environment
verfasst von
Shuji Sakai, M.D., Ph.D.
Hiroyasu Soeda, M.D.
Akio Furuya, M.D.
Hidetake Yabuuchi, M.D., Ph.D.
Takashi Okafuji, M.D.
Keiji Yamamoto, B.S.
Hiroshi Honda, M.D., Ph.D.
Kunio Doi, Ph.D.
Publikationsdatum
01.12.2006
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 4/2006
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-006-0625-5

Weitere Artikel der Ausgabe 4/2006

Journal of Digital Imaging 4/2006 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.