Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 2/2016

01.02.2016 | Original Article

Experimental investigation of intravascular OCT for imaging of intracranial aneurysms

verfasst von: Thomas Hoffmann, Sylvia Glaßer, Axel Boese, Knut Brandstädter, Thomas Kalinski, Oliver Beuing, Martin Skalej

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Rupture risk assessment of an intracranial aneurysm (IA) is an important factor for indication of therapy. Until today, there is no suitable objective prediction method. Conventional imaging modalities cannot assess the IA’s vessel wall. We investigated the ability of intravascular optical coherence tomography (OCT) as a new tool for the characterization and evaluation of IAs.

Materials and methods

An experimental setup for acquisition of geometrical aneurysm parameters was developed. Object of basic investigation was a silicone phantom with six IAs from patient data. For structural information, three circle of Willis were dissected and imaged postmortem. All image data were postprocessed by medical imaging software.

Results

Geometrical image data of a phantom with six different IAs were acquired. The geometrical image data showed a signal loss, e.g., in aneurysms with a high bottleneck ratio. Imaging data of vessel specimens were evaluated with respect to structural information that is valuable for the characterization of IAs. Those included thin structures (intimal flaps), changes of the vessel wall morphology (intimal thickening, layers), adjacent vessels, small vessel outlets, arterial branches and histological information.

Conclusion

Intravascular OCT provides new possibilities for diagnosis and rupture assessment of IAs. However, currently used imaging system parameters have to be adapted and new catheter techniques have to be developed for a complete assessment of the morphology of IAs.
Literatur
1.
Zurück zum Zitat Forsting M, Wanke I (2008) Intracranial vascular malformations and aneurysms. Springer, BerlinCrossRef Forsting M, Wanke I (2008) Intracranial vascular malformations and aneurysms. Springer, BerlinCrossRef
3.
Zurück zum Zitat Mueller OM, Schlamann M, Mueller D, Sandalcioglu IE, Forsting M, Sure U (2011) Intracranial aneurysms: optimized diagnostic tools call for thorough interdisciplinary treatment strategies. Therapeutic advances in neurological disorders, pp. 1756285611415309 Mueller OM, Schlamann M, Mueller D, Sandalcioglu IE, Forsting M, Sure U (2011) Intracranial aneurysms: optimized diagnostic tools call for thorough interdisciplinary treatment strategies. Therapeutic advances in neurological disorders, pp. 1756285611415309
4.
Zurück zum Zitat Vernooij MW, Ikram MA, Tanghe HL, Vincent Arnaud JPE, Hofman A, Krestin GP, Niessen WJ, Breteler Monique MB, van der Lugt A (2007) Incidental findings on brain MRI in the general population. N Engl J Med 357(18):1821–1828CrossRefPubMed Vernooij MW, Ikram MA, Tanghe HL, Vincent Arnaud JPE, Hofman A, Krestin GP, Niessen WJ, Breteler Monique MB, van der Lugt A (2007) Incidental findings on brain MRI in the general population. N Engl J Med 357(18):1821–1828CrossRefPubMed
5.
Zurück zum Zitat Wiebers DO (2003) Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet 362(9378):103–110CrossRefPubMed Wiebers DO (2003) Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet 362(9378):103–110CrossRefPubMed
6.
Zurück zum Zitat Tearney GJ, Jang I-K, Bouma BE (2006) Optical coherence tomography for imaging the vulnerable plaque. J Biomed Opt 11(2):021002-021002-10CrossRef Tearney GJ, Jang I-K, Bouma BE (2006) Optical coherence tomography for imaging the vulnerable plaque. J Biomed Opt 11(2):021002-021002-10CrossRef
7.
Zurück zum Zitat Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang I-K, Akasaka T, Costa M, Guagliumi G, Grube E (2010) Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31(4):401–415CrossRefPubMed Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang I-K, Akasaka T, Costa M, Guagliumi G, Grube E (2010) Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31(4):401–415CrossRefPubMed
8.
Zurück zum Zitat Murata A, Wallace-Bradley D, Tellez A, Alviar C, Aboodi M, Sheehy A, Coleman L, Perkins L, Nakazawa G, Mintz G (2010) Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation. JACC Cardiovasc Imaging 3(1):76–84CrossRefPubMed Murata A, Wallace-Bradley D, Tellez A, Alviar C, Aboodi M, Sheehy A, Coleman L, Perkins L, Nakazawa G, Mintz G (2010) Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation. JACC Cardiovasc Imaging 3(1):76–84CrossRefPubMed
9.
Zurück zum Zitat Kang S-J, Mintz GS, Akasaka T, Park D-W, Lee J-Y, Kim W-J, Lee S-W, Kim Y-H, Lee CW, Park S-W (2011) Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation. Circulation 123(25):2954–2963CrossRefPubMed Kang S-J, Mintz GS, Akasaka T, Park D-W, Lee J-Y, Kim W-J, Lee S-W, Kim Y-H, Lee CW, Park S-W (2011) Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation. Circulation 123(25):2954–2963CrossRefPubMed
10.
Zurück zum Zitat Farooq MU, Khasnis A, Majid A, Kassab MY (2009) The role of optical coherence tomography in vascular medicine. Vasc Med 14(1):63–71CrossRefPubMed Farooq MU, Khasnis A, Majid A, Kassab MY (2009) The role of optical coherence tomography in vascular medicine. Vasc Med 14(1):63–71CrossRefPubMed
11.
Zurück zum Zitat Standish BA, Spears J, Marotta TR, Montanera W, Yang VX (2012) Vascular wall Imaging of vulnerable atherosclerotic carotid plaques: current state of the art and potential future of endovascular optical coherence tomography. Am J Neuroradiol 33(9):1642–1650CrossRefPubMed Standish BA, Spears J, Marotta TR, Montanera W, Yang VX (2012) Vascular wall Imaging of vulnerable atherosclerotic carotid plaques: current state of the art and potential future of endovascular optical coherence tomography. Am J Neuroradiol 33(9):1642–1650CrossRefPubMed
12.
Zurück zum Zitat Fujimoto JG, Pitris C, Boppart SA, Brezinski ME (2000) Optical coherence tomography: an emerging technology for biomedical imaging and optical biopsy. Neoplasia 2(1):9–25PubMedCentralCrossRefPubMed Fujimoto JG, Pitris C, Boppart SA, Brezinski ME (2000) Optical coherence tomography: an emerging technology for biomedical imaging and optical biopsy. Neoplasia 2(1):9–25PubMedCentralCrossRefPubMed
14.
Zurück zum Zitat Frösen J, Tulamo R, Paetau A, Laaksamo E, Korja M, Laakso A, Niemelä M, Hernesniemi J (2012) Saccular intracranial aneurysm: pathology and mechanisms, (eng). Acta Neuropathol 123(6):773–786CrossRefPubMed Frösen J, Tulamo R, Paetau A, Laaksamo E, Korja M, Laakso A, Niemelä M, Hernesniemi J (2012) Saccular intracranial aneurysm: pathology and mechanisms, (eng). Acta Neuropathol 123(6):773–786CrossRefPubMed
15.
Zurück zum Zitat Thorell WE, Chow MM, Prayson RA, Shure MA, Jeon SW, Huang D, Zeynalov E, Woo HH, Rasmussen PA, Rollins AM (2005) Optical coherence tomography: a new method to assess aneurysm healing. J Neurosurg 102(2):348PubMedCentralCrossRefPubMed Thorell WE, Chow MM, Prayson RA, Shure MA, Jeon SW, Huang D, Zeynalov E, Woo HH, Rasmussen PA, Rollins AM (2005) Optical coherence tomography: a new method to assess aneurysm healing. J Neurosurg 102(2):348PubMedCentralCrossRefPubMed
16.
Zurück zum Zitat Mathews MS, Su J, Heidari E, Levy EI, Linskey ME, Chen Z (2011) Neuroendovascular optical coherence tomography imaging and histological analysis. Neurosurgery 69(2):430PubMedCentralCrossRefPubMed Mathews MS, Su J, Heidari E, Levy EI, Linskey ME, Chen Z (2011) Neuroendovascular optical coherence tomography imaging and histological analysis. Neurosurgery 69(2):430PubMedCentralCrossRefPubMed
17.
Zurück zum Zitat Mathews MS, Su J, Heidari E, Linskey ME, Chen Z (eds) (2011) Neuro-endovascular optical coherence tomography imaging: clinical feasibility and applications. SPIE BiOS. International Society for Optics and Photonics, pp 788341-1–788341-7 Mathews MS, Su J, Heidari E, Linskey ME, Chen Z (eds) (2011) Neuro-endovascular optical coherence tomography imaging: clinical feasibility and applications. SPIE BiOS. International Society for Optics and Photonics, pp 788341-1–788341-7
18.
Zurück zum Zitat Lopes DK, Johnson AK (2011) Evaluation of cerebral artery perforators and the pipeline embolization device using optical coherence tomography. J Neurointerv Surg neurintsurg-2011-010102 Lopes DK, Johnson AK (2011) Evaluation of cerebral artery perforators and the pipeline embolization device using optical coherence tomography. J Neurointerv Surg neurintsurg-2011-010102
19.
Zurück zum Zitat van der Marel K, Gounis M, King R, Wakhloo A, Puri A (2014) P-001 high-resolution optical and angiographic CT imaging of flow-diverter stents for assessment of vessel wall apposition, (eng). J Neurointerv Surg 6(Suppl 1):A21CrossRef van der Marel K, Gounis M, King R, Wakhloo A, Puri A (2014) P-001 high-resolution optical and angiographic CT imaging of flow-diverter stents for assessment of vessel wall apposition, (eng). J Neurointerv Surg 6(Suppl 1):A21CrossRef
20.
Zurück zum Zitat Costalat V, Sanchez M, Ambard D, Thines L, Lonjon N, Nicoud F, Brunel H, Lejeune JP, Dufour H, Bouillot P (2011) Biomechanical wall properties of human intracranial aneurysms resected following surgical clipping (IRRAs Project). J Biomech 44(15):2685–2691CrossRefPubMed Costalat V, Sanchez M, Ambard D, Thines L, Lonjon N, Nicoud F, Brunel H, Lejeune JP, Dufour H, Bouillot P (2011) Biomechanical wall properties of human intracranial aneurysms resected following surgical clipping (IRRAs Project). J Biomech 44(15):2685–2691CrossRefPubMed
21.
Zurück zum Zitat Sun C, Standish B, Yang VXD (2011) Optical coherence elastography: current status and future applications. J Biomed Opt 16(4):043001-043001-12CrossRef Sun C, Standish B, Yang VXD (2011) Optical coherence elastography: current status and future applications. J Biomed Opt 16(4):043001-043001-12CrossRef
22.
Zurück zum Zitat Lall RR, Eddleman CS, Bendok BR, Batjer HH (2009) Unruptured intracranial aneurysms and the assessment of rupture risk based on anatomical and morphological factors: sifting through the sands of data. Neurosurg Focus 26(5):E2CrossRefPubMed Lall RR, Eddleman CS, Bendok BR, Batjer HH (2009) Unruptured intracranial aneurysms and the assessment of rupture risk based on anatomical and morphological factors: sifting through the sands of data. Neurosurg Focus 26(5):E2CrossRefPubMed
23.
Zurück zum Zitat Kleinloog R, Korkmaz E, Zwanenburg JJ, Kuijf HJ, Visser F, Blankena R, Post JA, Ruigrok YM, Luijten PR, Regli L, Rinkel GJ, Verweij BH (2014) Visualization of the aneurysm wall: a 7.0-tesla magnetic resonance imaging study. Neurosurgery 75(6):614–622CrossRefPubMed Kleinloog R, Korkmaz E, Zwanenburg JJ, Kuijf HJ, Visser F, Blankena R, Post JA, Ruigrok YM, Luijten PR, Regli L, Rinkel GJ, Verweij BH (2014) Visualization of the aneurysm wall: a 7.0-tesla magnetic resonance imaging study. Neurosurgery 75(6):614–622CrossRefPubMed
Metadaten
Titel
Experimental investigation of intravascular OCT for imaging of intracranial aneurysms
verfasst von
Thomas Hoffmann
Sylvia Glaßer
Axel Boese
Knut Brandstädter
Thomas Kalinski
Oliver Beuing
Martin Skalej
Publikationsdatum
01.02.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 2/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1275-1

Weitere Artikel der Ausgabe 2/2016

International Journal of Computer Assisted Radiology and Surgery 2/2016 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.