Skip to main content
Erschienen in: Surgical Endoscopy 2/2017

17.06.2016

Face validity of the pulsatile organ perfusion trainer for laparoscopic cholecystectomy

verfasst von: Felix Nickel, Karl-Friedrich Kowalewski, Florian Rehberger, Jonathan David Hendrie, Benjamin Friedrich Berthold Mayer, Hannes Götz Kenngott, Vasile Bintintan, Georg Richard Linke, Lars Fischer, Beat Peter Müller-Stich

Erschienen in: Surgical Endoscopy | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

The pulsatile organ perfusion (POP) trainer provides training of minimally invasive surgery (MIS) with real instruments and cadaveric organs. It provides training of full procedures with simulation of bleeding. Although widely used, the face validity has not yet been evaluated. This study aimed to establish face validity of the POP trainer for laparoscopic cholecystectomy (LC) and its usefulness compared with other training modalities.

Materials and methods

During MIS courses, the participants (n = 52) used the POP trainer to perform LC. Face validity was assessed with questionnaires for realism and usefulness on a five-point Likert scale. Participants were divided into two groups: experts (n = 15) who had performed more than 50 laparoscopic procedures and novices (n = 37) with less than 50 procedures. Secondary aims included the ranking of training modalities, as well as exploration of their specific advantages and disadvantages.

Results

The POP trainer was found to be realistic (3.8 ± 0.9) and useful (4.6 ± 0.9). Differences between experts and novices were only found for “The training modality resembles reality” (3.1 ± 0.8 vs. 3.8 ± 0.7; p = 0.010), “The operation on the POP trainer is realistic” (3.4 ± 1.1 vs. 4.5 ± 0.8; p = 0.003), and “It would be desirable to have a POP trainer at my own hospital” (4.2 ± 1.1 vs. 4.8 ± 0.8; p = 0.040). In the ranking, the animal training (1.1 ± 0.3) placed first, the POP trainer (2.3 ± 0.9) second, and the VR trainer (2.8 ± 0.9) and box trainer (2.8 ± 1.1) third. The realistic simulation of animal training was named as an advantage most often, while the unrealistic simulation of the VR trainer was the most often named disadvantage.

Conclusions

The POP trainer was rated a highly realistic and useful training modality with face validity for LC. Differences between experts and novices existed concerning realism and desirability. Future studies should evaluate the POP trainer for more advanced surgical procedures. The POP trainer widens the spectrum of modalities for training of MIS in a safe environment outside the operating room.
Literatur
1.
Zurück zum Zitat Gallagher AG, McClure N, McGuigan J, Crothers I, Browning J (1999) Virtual reality training in laparoscopic surgery: a preliminary assessment of minimally invasive surgical trainer virtual reality (MIST VR). Endoscopy 31(4):310–313. doi:10.1055/s-1999-15 CrossRefPubMed Gallagher AG, McClure N, McGuigan J, Crothers I, Browning J (1999) Virtual reality training in laparoscopic surgery: a preliminary assessment of minimally invasive surgical trainer virtual reality (MIST VR). Endoscopy 31(4):310–313. doi:10.​1055/​s-1999-15 CrossRefPubMed
2.
Zurück zum Zitat Madan AK, Frantzides CT, Shervin N, Tebbit CL (2003) Assessment of individual hand performance in box trainers compared to virtual reality trainers. Am Surg 69(12):1112–1114PubMed Madan AK, Frantzides CT, Shervin N, Tebbit CL (2003) Assessment of individual hand performance in box trainers compared to virtual reality trainers. Am Surg 69(12):1112–1114PubMed
4.
Zurück zum Zitat Wyles SM, Miskovic D, Ni Z, Acheson AG, Maxwell-Armstrong C, Longman R, Cecil T, Coleman MG, Horgan AF, Hanna GB (2011) Analysis of laboratory-based laparoscopic colorectal surgery workshops within the English National Training Programme. Surg Endosc 25(5):1559–1566. doi:10.1007/s00464-010-1434-y CrossRefPubMed Wyles SM, Miskovic D, Ni Z, Acheson AG, Maxwell-Armstrong C, Longman R, Cecil T, Coleman MG, Horgan AF, Hanna GB (2011) Analysis of laboratory-based laparoscopic colorectal surgery workshops within the English National Training Programme. Surg Endosc 25(5):1559–1566. doi:10.​1007/​s00464-010-1434-y CrossRefPubMed
5.
Zurück zum Zitat Clerici T, Lange J, Zerz A, Beller S, Szinicz G, Losert UO, Siegl H, Fugger R (1995) Educational opportunities in minimally invasive surgery. Wien Klin Wochenschr 107(2):43–48PubMed Clerici T, Lange J, Zerz A, Beller S, Szinicz G, Losert UO, Siegl H, Fugger R (1995) Educational opportunities in minimally invasive surgery. Wien Klin Wochenschr 107(2):43–48PubMed
6.
Zurück zum Zitat Szinicz G, Beller S, Zerz A (1997) Role of the pulsatile organ perfusion surgical simulator in surgery education. Langenbecks Arch Chir Suppl Kongressbd 114:687–693PubMed Szinicz G, Beller S, Zerz A (1997) Role of the pulsatile organ perfusion surgical simulator in surgery education. Langenbecks Arch Chir Suppl Kongressbd 114:687–693PubMed
7.
Zurück zum Zitat Szinicz G, Beller S, Zerz A, Bodner W (1994) The Pulsatile Organ Perfusion—a chance to reduce animal experiments in minimally invasive surgery training. Altex 11(1):40–43PubMed Szinicz G, Beller S, Zerz A, Bodner W (1994) The Pulsatile Organ Perfusion—a chance to reduce animal experiments in minimally invasive surgery training. Altex 11(1):40–43PubMed
8.
Zurück zum Zitat Arikatla VS, Sankaranarayanan G, Ahn W, Chellali A, De S, Caroline GL, Hwabejire J, DeMoya M, Schwaitzberg S, Jones DB (2013) Face and construct validation of a virtual peg transfer simulator. Surg Endosc 27(5):1721–1729. doi:10.1007/s00464-012-2664-y CrossRefPubMed Arikatla VS, Sankaranarayanan G, Ahn W, Chellali A, De S, Caroline GL, Hwabejire J, DeMoya M, Schwaitzberg S, Jones DB (2013) Face and construct validation of a virtual peg transfer simulator. Surg Endosc 27(5):1721–1729. doi:10.​1007/​s00464-012-2664-y CrossRefPubMed
11.
Zurück zum Zitat Cronbach LJ, Meehl PE (1955) Construct validity in psychological tests. Psychol Bull 52(4):281–302CrossRefPubMed Cronbach LJ, Meehl PE (1955) Construct validity in psychological tests. Psychol Bull 52(4):281–302CrossRefPubMed
12.
Zurück zum Zitat Fried GM, Feldman LS, Vassiliou MC, Fraser SA, Stanbridge D, Ghitulescu G, Andrew CG (2004) Proving the value of simulation in laparoscopic surgery. Ann Surg 240(3):518–525 (discussion 525–518) CrossRefPubMedPubMedCentral Fried GM, Feldman LS, Vassiliou MC, Fraser SA, Stanbridge D, Ghitulescu G, Andrew CG (2004) Proving the value of simulation in laparoscopic surgery. Ann Surg 240(3):518–525 (discussion 525–518) CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Nickel F, Hendrie JD, Stock C, Salama M, Preukschas AA, Senft JD, Kowalewski KF, Wagner M, Kenngott HG, Linke GR, Fischer L, Muller-Stich BP (2016) Direct observation versus endoscopic video recording-based rating with the objective structured assessment of technical skills for training of laparoscopic cholecystectomy. Eur Surg Res 57(1–2):1–9. doi:10.1159/000444449 CrossRefPubMed Nickel F, Hendrie JD, Stock C, Salama M, Preukschas AA, Senft JD, Kowalewski KF, Wagner M, Kenngott HG, Linke GR, Fischer L, Muller-Stich BP (2016) Direct observation versus endoscopic video recording-based rating with the objective structured assessment of technical skills for training of laparoscopic cholecystectomy. Eur Surg Res 57(1–2):1–9. doi:10.​1159/​000444449 CrossRefPubMed
14.
Zurück zum Zitat Lopez-Gonzalez L, Pickens GT, Washington R, Weiss AJ (2006) Characteristics of Medicaid and Uninsured Hospitalizations, 2012: Statistical Brief #182. In: Healthcare cost and utilization project (HCUP) statistical briefs. Agency for Health Care Policy and Research (US), Rockville (MD) Lopez-Gonzalez L, Pickens GT, Washington R, Weiss AJ (2006) Characteristics of Medicaid and Uninsured Hospitalizations, 2012: Statistical Brief #182. In: Healthcare cost and utilization project (HCUP) statistical briefs. Agency for Health Care Policy and Research (US), Rockville (MD)
15.
Zurück zum Zitat Strasberg SM, Hertl M, Soper NJ (1995) An analysis of the problem of biliary injury during laparoscopic cholecystectomy. J Am Coll Surg 180(1):101–125PubMed Strasberg SM, Hertl M, Soper NJ (1995) An analysis of the problem of biliary injury during laparoscopic cholecystectomy. J Am Coll Surg 180(1):101–125PubMed
17.
Zurück zum Zitat Nickel F, Jede F, Minassian A, Gondan M, Hendrie JD, Gehrig T, Linke GR, Kadmon M, Fischer L, Müller-Stich BP (2014) One or two trainees per workplace in a structured multimodality training curriculum for laparoscopic surgery? Study protocol for a randomized controlled trial—DRKS00004675. Trials 15:137. doi:10.1186/1745-6215-15-137 CrossRefPubMedPubMedCentral Nickel F, Jede F, Minassian A, Gondan M, Hendrie JD, Gehrig T, Linke GR, Kadmon M, Fischer L, Müller-Stich BP (2014) One or two trainees per workplace in a structured multimodality training curriculum for laparoscopic surgery? Study protocol for a randomized controlled trial—DRKS00004675. Trials 15:137. doi:10.​1186/​1745-6215-15-137 CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Katz R, Hoznek A, Antiphon P, Van Velthoven R, Delmas V, Abbou CC (2003) Cadaveric versus porcine models in urological laparoscopic training. Urol Int 71(3):310–315CrossRefPubMed Katz R, Hoznek A, Antiphon P, Van Velthoven R, Delmas V, Abbou CC (2003) Cadaveric versus porcine models in urological laparoscopic training. Urol Int 71(3):310–315CrossRefPubMed
20.
Zurück zum Zitat Diesen DL, Erhunmwunsee L, Bennett KM, Ben-David K, Yurcisin B, Ceppa EP, Omotosho PA, Perez A, Pryor A (2011) Effectiveness of laparoscopic computer simulator versus usage of box trainer for endoscopic surgery training of novices. J Surg Educ 68(4):282–289. doi:10.1016/j.jsurg.2011.02.007 CrossRefPubMed Diesen DL, Erhunmwunsee L, Bennett KM, Ben-David K, Yurcisin B, Ceppa EP, Omotosho PA, Perez A, Pryor A (2011) Effectiveness of laparoscopic computer simulator versus usage of box trainer for endoscopic surgery training of novices. J Surg Educ 68(4):282–289. doi:10.​1016/​j.​jsurg.​2011.​02.​007 CrossRefPubMed
22.
Zurück zum Zitat Scott DJ, Bergen PC, Rege RV, Laycock R, Tesfay ST, Valentine RJ, Euhus DM, Jeyarajah DR, Thompson WM, Jones DB (2000) Laparoscopic training on bench models: better and more cost effective than operating room experience? J Am Coll Surg 191(3):272–283CrossRefPubMed Scott DJ, Bergen PC, Rege RV, Laycock R, Tesfay ST, Valentine RJ, Euhus DM, Jeyarajah DR, Thompson WM, Jones DB (2000) Laparoscopic training on bench models: better and more cost effective than operating room experience? J Am Coll Surg 191(3):272–283CrossRefPubMed
23.
Zurück zum Zitat van Velthoven RF, Hoffmann P (2006) Methods for laparoscopic training using animal models. Curr Urol Rep 7(2):114–119CrossRefPubMed van Velthoven RF, Hoffmann P (2006) Methods for laparoscopic training using animal models. Curr Urol Rep 7(2):114–119CrossRefPubMed
25.
Zurück zum Zitat Hammoud MM, Nuthalapaty FS, Goepfert AR, Casey PM, Emmons S, Espey EL, Kaczmarczyk JM, Katz NT, Neutens JJ, Peskin EG (2008) To the point: medical education review of the role of simulators in surgical training. Am J Obstet Gynecol 199(4):338–343. doi:10.1016/j.ajog.2008.05.002 CrossRefPubMed Hammoud MM, Nuthalapaty FS, Goepfert AR, Casey PM, Emmons S, Espey EL, Kaczmarczyk JM, Katz NT, Neutens JJ, Peskin EG (2008) To the point: medical education review of the role of simulators in surgical training. Am J Obstet Gynecol 199(4):338–343. doi:10.​1016/​j.​ajog.​2008.​05.​002 CrossRefPubMed
28.
30.
Zurück zum Zitat Bullock G, Kovacs G, Macdonald K, Story BA (1999) Evaluating procedural skills competence: inter-rater reliability of expert and non-expert observers. Acad Med 74(1):76–78CrossRefPubMed Bullock G, Kovacs G, Macdonald K, Story BA (1999) Evaluating procedural skills competence: inter-rater reliability of expert and non-expert observers. Acad Med 74(1):76–78CrossRefPubMed
Metadaten
Titel
Face validity of the pulsatile organ perfusion trainer for laparoscopic cholecystectomy
verfasst von
Felix Nickel
Karl-Friedrich Kowalewski
Florian Rehberger
Jonathan David Hendrie
Benjamin Friedrich Berthold Mayer
Hannes Götz Kenngott
Vasile Bintintan
Georg Richard Linke
Lars Fischer
Beat Peter Müller-Stich
Publikationsdatum
17.06.2016
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 2/2017
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-016-5025-4

Weitere Artikel der Ausgabe 2/2017

Surgical Endoscopy 2/2017 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.