Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 4/2013

01.04.2013 | Glaucoma

Five-year incidence of angle closure among glaucoma health examination participants

verfasst von: Kenji Kashiwagi, Tatsuya Chiba, Fumihiko Mabuchi, Toshie Furuya, Shigeo Tsukahara

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 4/2013

Einloggen, um Zugang zu erhalten

Abstract

Background and aim

To investigate incidence of angle closure (AC) and its associated factors through a community-based longitudinal study over a 5-year period.

Methods

Japanese residents aged 40 years or over who underwent two glaucoma health examinations held in 2005 and 2010 were enrolled. Of the participants of the first glaucoma health examination (first examination), those who satisfied exclusion criteria such as having eyes with angle closure, glaucoma, incisional ocular surgery, or other conditions that could influence the results were eliminated from the second glaucoma health examination (second examination). In addition to routine ophthalmic examination, a scanning peripheral anterior chamber depth analyzer (SPAC) was employed to investigate the anterior chamber configuration. The incidence of angle closure over the 5-year period and its associated factors were investigated.

Results

Of the 754 participants of the first examination, 569 participants were invited for the second examination and 331 participants (87 males and 244 females, age: 62.6 ± 12.7 years), or 619 eyes, were analyzed after eliminating eyes matching exclusion criteria. In the 5-year period, the incidence of AC was 5.4 % (95 % CI: 3.5–8.4 %) of participants or 5.5 % (95 % CI: 4.0–7.6 %) of eyes, including eight eyes (1.3 %) with primary angle-closure glaucoma. Eyes that developed AC had a much smaller SPAC grade at the first examination and a greater decrease in SPAC grade than those that did not develop AC, whereas age and sex were not associated.

Conclusions

AC was developed by 5.4 % of senior Japanese residents over the 5-year period. The shallow anterior chamber and the marked decrease in anterior chamber depth were associated with AC development.
Literatur
1.
3.
Zurück zum Zitat Wong TY, Loon SC, Saw SM (2006) The epidemiology of age related eye diseases in Asia. Br J Ophthalmol 90:506–511PubMedCrossRef Wong TY, Loon SC, Saw SM (2006) The epidemiology of age related eye diseases in Asia. Br J Ophthalmol 90:506–511PubMedCrossRef
4.
Zurück zum Zitat Ang LP, Aung T, Chew PT (2000) Acute primary angle closure in an Asian population: long-term outcome of the fellow eye after prophylactic laser peripheral iridotomy. Ophthalmology 107:2092–2096PubMedCrossRef Ang LP, Aung T, Chew PT (2000) Acute primary angle closure in an Asian population: long-term outcome of the fellow eye after prophylactic laser peripheral iridotomy. Ophthalmology 107:2092–2096PubMedCrossRef
5.
Zurück zum Zitat Aung T, Nolan WP, Machin D, Seah SK, Baasanhu J, Khaw PT, Johnson GJ, Foster PJ (2005) Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations. Arch Ophthalmol 123:527–532PubMedCrossRef Aung T, Nolan WP, Machin D, Seah SK, Baasanhu J, Khaw PT, Johnson GJ, Foster PJ (2005) Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations. Arch Ophthalmol 123:527–532PubMedCrossRef
6.
Zurück zum Zitat Chang DS, Sakata LM, Aung T, He MG, Lavanya R, Kashiwagi K, Friedman DS (2011) Single versus sequential testing with scanning peripheral anterior chamber depth analyser, IOLMaster and anterior segment optical coherence tomography for the detection of narrow angles. Br J Ophthalmol 95:1410–1414PubMedCrossRef Chang DS, Sakata LM, Aung T, He MG, Lavanya R, Kashiwagi K, Friedman DS (2011) Single versus sequential testing with scanning peripheral anterior chamber depth analyser, IOLMaster and anterior segment optical coherence tomography for the detection of narrow angles. Br J Ophthalmol 95:1410–1414PubMedCrossRef
7.
Zurück zum Zitat Lavanya R, Foster PJ, Sakata LM, Friedman DS, Kashiwagi K, Wong TY, Aung HT, Alfred T, Gao H, Ee AG, Seah SK, Aung T (2008) Screening for narrow angles in the Singapore population: evaluation of new noncontact screening methods. Ophthalmology 115:1720–1727PubMedCrossRef Lavanya R, Foster PJ, Sakata LM, Friedman DS, Kashiwagi K, Wong TY, Aung HT, Alfred T, Gao H, Ee AG, Seah SK, Aung T (2008) Screening for narrow angles in the Singapore population: evaluation of new noncontact screening methods. Ophthalmology 115:1720–1727PubMedCrossRef
8.
Zurück zum Zitat Lavanya R, Teo L, Friedman DS, Aung HT, Baskaran M, Gao H, Alfred T, Seah SK, Kashiwagi K, Foster PJ, Aung T (2007) Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography. Br J Ophthalmol 91:1023–1026PubMedCrossRef Lavanya R, Teo L, Friedman DS, Aung HT, Baskaran M, Gao H, Alfred T, Seah SK, Kashiwagi K, Foster PJ, Aung T (2007) Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography. Br J Ophthalmol 91:1023–1026PubMedCrossRef
9.
Zurück zum Zitat Nolan WP, Aung T, Machin D, Khaw PT, Johnson GJ, Seah SK, Foster PJ (2006) Detection of narrow angles and established angle closure in Chinese residents of Singapore: potential screening tests. Am J Ophthalmol 141:896–901PubMedCrossRef Nolan WP, Aung T, Machin D, Khaw PT, Johnson GJ, Seah SK, Foster PJ (2006) Detection of narrow angles and established angle closure in Chinese residents of Singapore: potential screening tests. Am J Ophthalmol 141:896–901PubMedCrossRef
10.
Zurück zum Zitat Nolan WP, See JL, Chew PT, Friedman DS, Smith SD, Radhakrishnan S, Zheng C, Foster PJ, Aung T (2007) Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes. Ophthalmology 114:33–39PubMedCrossRef Nolan WP, See JL, Chew PT, Friedman DS, Smith SD, Radhakrishnan S, Zheng C, Foster PJ, Aung T (2007) Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes. Ophthalmology 114:33–39PubMedCrossRef
11.
Zurück zum Zitat He M, Huang W, Friedman DS, Wu C, Zheng Y, Foster PJ (2007) Slit-lamp-simulated oblique flashlight test in the detection of narrow angles in Chinese eyes: the Liwan eye study. Invest Ophthalmol Vis Sci 48:5459–5463PubMedCrossRef He M, Huang W, Friedman DS, Wu C, Zheng Y, Foster PJ (2007) Slit-lamp-simulated oblique flashlight test in the detection of narrow angles in Chinese eyes: the Liwan eye study. Invest Ophthalmol Vis Sci 48:5459–5463PubMedCrossRef
12.
Zurück zum Zitat Kurita N, Mayama C, Tomidokoro A, Aihara M, Araie M (2009) Potential of the pentacam in screening for primary angle closure and primary angle closure suspect. J Glaucoma 18:506–512PubMedCrossRef Kurita N, Mayama C, Tomidokoro A, Aihara M, Araie M (2009) Potential of the pentacam in screening for primary angle closure and primary angle closure suspect. J Glaucoma 18:506–512PubMedCrossRef
13.
Zurück zum Zitat Nolan WP, Baasanhu J, Undraa A, Uranchimeg D, Ganzorig S, Johnson GJ (2003) Screening for primary angle closure in Mongolia: a randomised controlled trial to determine whether screening and prophylactic treatment will reduce the incidence of primary angle closure glaucoma in an east Asian population. Br J Ophthalmol 87:271–274PubMedCrossRef Nolan WP, Baasanhu J, Undraa A, Uranchimeg D, Ganzorig S, Johnson GJ (2003) Screening for primary angle closure in Mongolia: a randomised controlled trial to determine whether screening and prophylactic treatment will reduce the incidence of primary angle closure glaucoma in an east Asian population. Br J Ophthalmol 87:271–274PubMedCrossRef
14.
Zurück zum Zitat Andrews J, Chang DS, Jiang Y, He M, Foster PJ, Munoz B, Kashiwagi K, Friedman DS (2011) Comparing approaches to screening for angle closure in older Chinese adults. Eye (Lond) 26:96–100CrossRef Andrews J, Chang DS, Jiang Y, He M, Foster PJ, Munoz B, Kashiwagi K, Friedman DS (2011) Comparing approaches to screening for angle closure in older Chinese adults. Eye (Lond) 26:96–100CrossRef
15.
Zurück zum Zitat Casson RJ, Baker M, Edussuriya K, Senaratne T, Selva D, Sennanayake S (2009) Prevalence and determinants of angle closure in central Sri Lanka: the Kandy Eye Study. Ophthalmology 116:1444–1449PubMedCrossRef Casson RJ, Baker M, Edussuriya K, Senaratne T, Selva D, Sennanayake S (2009) Prevalence and determinants of angle closure in central Sri Lanka: the Kandy Eye Study. Ophthalmology 116:1444–1449PubMedCrossRef
16.
Zurück zum Zitat Van Herick W, Shaffer RN, Schwartz A (1969) Estimation of width of angle of anterior chamber. Incidence and significance of the narrow angle. Am J Ophthalmol 68:626–629PubMed Van Herick W, Shaffer RN, Schwartz A (1969) Estimation of width of angle of anterior chamber. Incidence and significance of the narrow angle. Am J Ophthalmol 68:626–629PubMed
17.
Zurück zum Zitat Kashiwagi K, Tokunaga T, Iwase A, Yamamoto T, Tsukahara S (2005) Usefulness of peripheral anterior chamber depth assessment in glaucoma screening. Eye 19:990–994PubMedCrossRef Kashiwagi K, Tokunaga T, Iwase A, Yamamoto T, Tsukahara S (2005) Usefulness of peripheral anterior chamber depth assessment in glaucoma screening. Eye 19:990–994PubMedCrossRef
18.
Zurück zum Zitat Xu L, Cao WF, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study. Am J Ophthalmol 145:929–936PubMedCrossRef Xu L, Cao WF, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study. Am J Ophthalmol 145:929–936PubMedCrossRef
19.
Zurück zum Zitat Chen HB, Kashiwagi K, Yamabayashi S, Kinoshita T, Ou B, Tsukahara S (1998) Anterior chamber angle biometry: quadrant variation, age change and sex difference. Curr Eye Res 17:120–124PubMedCrossRef Chen HB, Kashiwagi K, Yamabayashi S, Kinoshita T, Ou B, Tsukahara S (1998) Anterior chamber angle biometry: quadrant variation, age change and sex difference. Curr Eye Res 17:120–124PubMedCrossRef
20.
Zurück zum Zitat Thomas RGR, Parikh R, Muliyil J, Jacob A (2003) Five year risk of progression of primary angle closure suspects to primary angle closure: a population based study. Br J Ophthalmol 87:480–485CrossRef Thomas RGR, Parikh R, Muliyil J, Jacob A (2003) Five year risk of progression of primary angle closure suspects to primary angle closure: a population based study. Br J Ophthalmol 87:480–485CrossRef
21.
Zurück zum Zitat Thomas R, Parikh R, Muliyil J, Kumar RS (2003) Five-year risk of progression of primary angle closure to primary angle closure glaucoma: a population-based study. Acta Ophthalmol Scand 81:480–485PubMedCrossRef Thomas R, Parikh R, Muliyil J, Kumar RS (2003) Five-year risk of progression of primary angle closure to primary angle closure glaucoma: a population-based study. Acta Ophthalmol Scand 81:480–485PubMedCrossRef
22.
Zurück zum Zitat Yip JL, Foster PJ, Gilbert CE, Uranchimeg D, Bassanhuu J, Lee PS, Khaw PT, Johnson GJ, Nolan W (2008) Incidence of occludable angles in a high-risk Mongolian population. Br J Ophthalmol 92:30–33PubMedCrossRef Yip JL, Foster PJ, Gilbert CE, Uranchimeg D, Bassanhuu J, Lee PS, Khaw PT, Johnson GJ, Nolan W (2008) Incidence of occludable angles in a high-risk Mongolian population. Br J Ophthalmol 92:30–33PubMedCrossRef
23.
Zurück zum Zitat Kashiwagi K, Kashiwagi F, Toda Y, Osada K, Tsumura T, Tsukahara S (2004) A newly developed peripheral anterior chamber depth analysis system — principle, accuracy, and reproducibility. Br J Ophthalmol 88:1029–1034 Kashiwagi K, Kashiwagi F, Toda Y, Osada K, Tsumura T, Tsukahara S (2004) A newly developed peripheral anterior chamber depth analysis system — principle, accuracy, and reproducibility. Br J Ophthalmol 88:1029–1034
24.
Zurück zum Zitat Kashiwagi K, Shinbayashi E, Tsukahara S (2006) Development of a fully automated peripheral anterior chamber depth analyzer and evaluation of its accuracy. J Glaucoma 15:388–393PubMedCrossRef Kashiwagi K, Shinbayashi E, Tsukahara S (2006) Development of a fully automated peripheral anterior chamber depth analyzer and evaluation of its accuracy. J Glaucoma 15:388–393PubMedCrossRef
25.
Zurück zum Zitat Kashiwagi K, Kashiwagi F, Hiejima Y, Tsukahara S (2006) Finding cases of angle-closure glaucoma in clinic setting using a newly developed instrument. Eye 20:319–324PubMedCrossRef Kashiwagi K, Kashiwagi F, Hiejima Y, Tsukahara S (2006) Finding cases of angle-closure glaucoma in clinic setting using a newly developed instrument. Eye 20:319–324PubMedCrossRef
26.
Zurück zum Zitat Anderson DR, Patella VM (1999) Automated static perimetry (2nd ed.). Mosby, St. Louis Anderson DR, Patella VM (1999) Automated static perimetry (2nd ed.). Mosby, St. Louis
27.
Zurück zum Zitat Foster PJ, Buhrmann R, Quigley HA, Johnson GJ (2002) The definition and classification of glaucoma in prevalence surveys. Br J Ophthalmol 86:238–242PubMedCrossRef Foster PJ, Buhrmann R, Quigley HA, Johnson GJ (2002) The definition and classification of glaucoma in prevalence surveys. Br J Ophthalmol 86:238–242PubMedCrossRef
28.
Zurück zum Zitat Iwase A, Suzuki Y, Araie M, Yamamoto T, Abe H, Shirato S, Kuwayama Y, Mishima HK, Shimizu H, Tomita G (2004) The prevalence of primary open-angle glaucoma in Japanese: the Tajimi Study. Ophthalmology 111:1641–1648PubMed Iwase A, Suzuki Y, Araie M, Yamamoto T, Abe H, Shirato S, Kuwayama Y, Mishima HK, Shimizu H, Tomita G (2004) The prevalence of primary open-angle glaucoma in Japanese: the Tajimi Study. Ophthalmology 111:1641–1648PubMed
29.
Zurück zum Zitat Yamamoto T, Iwase A, Araie M, Suzuki Y, Abe H, Shirato S, Kuwayama Y, Mishima HK, Shimizu H, Tomita G, Inoue Y, Kitazawa Y (2005) The Tajimi Study report 2: prevalence of primary angle closure and secondary glaucoma in a Japanese population. Ophthalmology 112:1661–1669PubMedCrossRef Yamamoto T, Iwase A, Araie M, Suzuki Y, Abe H, Shirato S, Kuwayama Y, Mishima HK, Shimizu H, Tomita G, Inoue Y, Kitazawa Y (2005) The Tajimi Study report 2: prevalence of primary angle closure and secondary glaucoma in a Japanese population. Ophthalmology 112:1661–1669PubMedCrossRef
30.
Zurück zum Zitat Foster PJ, Baasanhu J, Alsbirk PH, Munkhbayar D, Uranchimeg D, Johnson GJ (1996) Glaucoma in Mongolia. A population-based survey in Hovsgol province, northern Mongolia. Arch Ophthalmol 114:1235–1241PubMedCrossRef Foster PJ, Baasanhu J, Alsbirk PH, Munkhbayar D, Uranchimeg D, Johnson GJ (1996) Glaucoma in Mongolia. A population-based survey in Hovsgol province, northern Mongolia. Arch Ophthalmol 114:1235–1241PubMedCrossRef
31.
Zurück zum Zitat Shiose Y, Kitazawa Y, Tsukahara S, Akamatsu T, Mizokami K, Futa R, Katsushima H, Kosaki H (1991) Epidemiology of glaucoma in Japan—a nationwide glaucoma survey. Jpn J Ophthalmol 35:133–155PubMed Shiose Y, Kitazawa Y, Tsukahara S, Akamatsu T, Mizokami K, Futa R, Katsushima H, Kosaki H (1991) Epidemiology of glaucoma in Japan—a nationwide glaucoma survey. Jpn J Ophthalmol 35:133–155PubMed
32.
Zurück zum Zitat Sawaguchi S, Sakai H, Iwase A, Yamamoto T, Abe H, Tomita G, Tomidokoro A, Araie M (2012) Prevalence of primary angle closure and primary angle-closure glaucoma in a southwestern rural population of Japan: the Kumejima Study. Ophthalmology 119:1134–1142PubMedCrossRef Sawaguchi S, Sakai H, Iwase A, Yamamoto T, Abe H, Tomita G, Tomidokoro A, Araie M (2012) Prevalence of primary angle closure and primary angle-closure glaucoma in a southwestern rural population of Japan: the Kumejima Study. Ophthalmology 119:1134–1142PubMedCrossRef
33.
Zurück zum Zitat Pan Z, Furuya T, Kashiwagi K (2011) Longitudinal changes in anterior chamber configuration in eyes with open-angle glaucoma and associated factors. J Glaucoma 37:296–301 Pan Z, Furuya T, Kashiwagi K (2011) Longitudinal changes in anterior chamber configuration in eyes with open-angle glaucoma and associated factors. J Glaucoma 37:296–301
34.
Zurück zum Zitat Yao BQ, Wu LL, Zhang C, Wang X (2009) Ultrasound biomicroscopic features associated with angle closure in fellow eyes of acute primary angle closure after laser iridotomy. Ophthalmology 116:444–448PubMedCrossRef Yao BQ, Wu LL, Zhang C, Wang X (2009) Ultrasound biomicroscopic features associated with angle closure in fellow eyes of acute primary angle closure after laser iridotomy. Ophthalmology 116:444–448PubMedCrossRef
35.
Zurück zum Zitat Wang B, Sakata LM, Friedman DS, Chan YH, He M, Lavanya R, Wong TY, Aung T (2010) Quantitative iris parameters and association with narrow angles. Ophthalmology 117:11–17PubMedCrossRef Wang B, Sakata LM, Friedman DS, Chan YH, He M, Lavanya R, Wong TY, Aung T (2010) Quantitative iris parameters and association with narrow angles. Ophthalmology 117:11–17PubMedCrossRef
36.
Zurück zum Zitat Nongpiur ME, He M, Amerasinghe N, Friedman DS, Tay WT, Baskaran M, Smith SD, Wong TY, Aung T (2011) Lens vault, thickness, and position in Chinese subjects with angle closure. Ophthalmology 118:474–479PubMedCrossRef Nongpiur ME, He M, Amerasinghe N, Friedman DS, Tay WT, Baskaran M, Smith SD, Wong TY, Aung T (2011) Lens vault, thickness, and position in Chinese subjects with angle closure. Ophthalmology 118:474–479PubMedCrossRef
37.
Zurück zum Zitat See JL (2009) Imaging of the anterior segment in glaucoma. Clin Experiment Ophthalmol 37:506–513PubMedCrossRef See JL (2009) Imaging of the anterior segment in glaucoma. Clin Experiment Ophthalmol 37:506–513PubMedCrossRef
38.
Zurück zum Zitat Wong HT, Chua JL, Sakata LM, Wong MH, Aung HT, Aung T (2009) Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes. Arch Ophthalmol 127:599–603PubMedCrossRef Wong HT, Chua JL, Sakata LM, Wong MH, Aung HT, Aung T (2009) Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes. Arch Ophthalmol 127:599–603PubMedCrossRef
39.
Zurück zum Zitat Sakata LM, Lavanya R, Friedman DS, Aung HT, Gao H, Kumar RS, Foster PJ, Aung T (2008) Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. Ophthalmology 115:769–774PubMedCrossRef Sakata LM, Lavanya R, Friedman DS, Aung HT, Gao H, Kumar RS, Foster PJ, Aung T (2008) Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. Ophthalmology 115:769–774PubMedCrossRef
Metadaten
Titel
Five-year incidence of angle closure among glaucoma health examination participants
verfasst von
Kenji Kashiwagi
Tatsuya Chiba
Fumihiko Mabuchi
Toshie Furuya
Shigeo Tsukahara
Publikationsdatum
01.04.2013
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 4/2013
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-012-2179-1

Weitere Artikel der Ausgabe 4/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 4/2013 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.