Background

To assess the safety and 5-year efficacy of ab interno XEN 45 gel stent implantation with phacoemulsification in primary open-angle glaucoma (POAG).

Methods

Single-centre, single-surgeon, retrospective case note review of consecutive OAG patients who underwent ab-interno gel stent placement combined with phacoemulsification. Surgeries were performed between 2/01/2014 and 2/01/2016. Primary outcome measures: mean reduction in intraocular pressure (IOP) and change in number of ocular hypotensive medications from baseline (follow-up range 1–7 years; mean 54 months). Secondary outcome measure: change in visual field mean deviation (VFMD) from baseline. Safety data included intraoperative and post-operative complications and adverse events. Failure was defined by IOP reduction < 20% despite maximum medical therapy, the need for further laser or surgical intervention. At 5 years, 75% of eyes were free from failure (95% CI 64 to 83%).

Results

Ninety-one eyes were analysed. Mean (SD) IOP and medications decreased from 20.2 (6.4) mmHg and 2.9 (1.0) at baseline to 15.4 (3.6) mmHg (p < 0.001) and 1.5 (1.4) medications at 5 (p < 0.001) years. Baseline mean VFMD (SD) was − 10.3dB (8.5) reducing to − 10.9(8.2) (p < 0.01) at 5 years. Two (2%) eyes had intraoperative complications, 4 (4.3%) experienced post-operative AEs, and 13 (14%) required secondary surgical intervention (SSI).

Conclusion

The gel stent combined with phacoemulsification was effective in reducing IOP and medications over 5 years, with an acceptable safety profile. Visual field change was clinically acceptable through the study period.
Literatur
4.
Zurück zum Zitat Feiner L, Piltz-Seymour JR (2003) Collaborative Initial Glaucoma Treatment Study: a summary of results to date. Curr Opin Ophthalmol 14:106–111 CrossRefPubMed Feiner L, Piltz-Seymour JR (2003) Collaborative Initial Glaucoma Treatment Study: a summary of results to date. Curr Opin Ophthalmol 14:106–111 CrossRefPubMed
8.
Zurück zum Zitat Vera VI, Horvath C (2014) XEN gel stent: the solution designed by AqueSys®. In: Samples JR, Ahmed IIK (eds) Surgical innovations in glaucoma. Springer Science+Business Media, New York, pp 189–198 CrossRef Vera VI, Horvath C (2014) XEN gel stent: the solution designed by AqueSys®. In: Samples JR, Ahmed IIK (eds) Surgical innovations in glaucoma. Springer Science+Business Media, New York, pp 189–198 CrossRef
10.
Zurück zum Zitat Denis P, Hirneiß C, Durr GM et al (2022) Two-year outcomes of the MINIject drainage system for uncontrolled glaucoma from the STAR-I first-in-human trial. Br J Ophthalmol 106:65–70 CrossRefPubMed Denis P, Hirneiß C, Durr GM et al (2022) Two-year outcomes of the MINIject drainage system for uncontrolled glaucoma from the STAR-I first-in-human trial. Br J Ophthalmol 106:65–70 CrossRefPubMed
18.
Zurück zum Zitat Gillmann K, Bravetti GE, Mermoud A, Rao HL, Mansouri K (2019) XEN Gel Stent in pseudoexfoliative glaucoma: 2-year results of a prospective evaluation. J Glaucoma 28:676–684 CrossRefPubMed Gillmann K, Bravetti GE, Mermoud A, Rao HL, Mansouri K (2019) XEN Gel Stent in pseudoexfoliative glaucoma: 2-year results of a prospective evaluation. J Glaucoma 28:676–684 CrossRefPubMed
19.
Zurück zum Zitat Reitsamer H, Sng C, Vera V, Lenzhofer M, Barton K, Stalmans I (2019) Two-year results of a multicenter study of the ab interno gelatin implant in medically uncontrolled primary open-angle glaucoma. Graefes Arch Clin Exp Ophthalmol 257:983–996 CrossRefPubMed Reitsamer H, Sng C, Vera V, Lenzhofer M, Barton K, Stalmans I (2019) Two-year results of a multicenter study of the ab interno gelatin implant in medically uncontrolled primary open-angle glaucoma. Graefes Arch Clin Exp Ophthalmol 257:983–996 CrossRefPubMed
20.
Zurück zum Zitat Gabbay IE, Allen F, Morley C et al (2020) Efficacy and safety data for the XEN45 implant at 2 years: a retrospective analysis. Br J Ophthalmol 104:1125–1130 CrossRefPubMed Gabbay IE, Allen F, Morley C et al (2020) Efficacy and safety data for the XEN45 implant at 2 years: a retrospective analysis. Br J Ophthalmol 104:1125–1130 CrossRefPubMed
25.
Metadaten
Titel
Five-year outcomes of ab interno Xen 45 gel stent implantation
verfasst von
Ejaz Ansari
Publikationsdatum
13.11.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-023-06294-9