Flap-sparing canaloplasty: a modified approach to Schlemm’s canal

verfasst von: Matthias C. Grieshaber, Ané Pienaar, Robert Stegmann

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 8/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To present a modified surgical technique for canaloplasty with the Stegmann Canal Expander obviating the need for lamellar scleral dissection.

Methods

After limbal peritomy of the conjunctiva, the sclera is not dissected in the classic lamellar fashion with superficial and deep scleral flaps but is successively ‘scratched’ down by radial incision until Schlemm’s canal (SC) is opened (trench cut). Following canal opening and viscodilation with a microcannula and sodium hyaluronidate, one Stegmann Canal Expander is implanted on either side of the canal ostia and the scleral incision is closed watertight.

Results

Twenty-seven eyes with primary open-angle glaucoma (POAG) were consecutively operated on using this modified technique. In all eyes, SC was successively opened, but exposure of the choroid and rupture of trabeculo-Descemet’s membrane with iris prolapse or filtering blebs were not found. Adverse events included trimming of the expander in one eye for incomplete implantation during surgery, and transient microhyphaema in five eyes post-surgery. Mean intraocular pressure (IOP) was 31.9 mmHg ± 6.0 (SD) before surgery and 14.0 mmHg ± 2.5 (SD) 6 months and 15.2 mmHg ± 1.95 (SD) 12 months after surgery.

Conclusions

The flap-sparing, trench-cut incision technique may reduce the risk of complications in canaloplasty with the Stegmann Canal Expander while effectively lowering IOP in POAG patients.
Literatur
1.
Zurück zum Zitat Kozlov VI, Bagrov SN, Anisimova SY (1990) Nonpenetrating deep sclerectomy with collagen. Eye Microsurgery 3:157–162 Kozlov VI, Bagrov SN, Anisimova SY (1990) Nonpenetrating deep sclerectomy with collagen. Eye Microsurgery 3:157–162
2.
Zurück zum Zitat Fedorov SN, Ioffe DI, Ronkina TI (1982) Glaucoma surgery - deep sclerectomy. Vestn oftalmol 6–10 Fedorov SN, Ioffe DI, Ronkina TI (1982) Glaucoma surgery - deep sclerectomy. Vestn oftalmol 6–10
3.
Zurück zum Zitat Stegmann R (1995) Visco-canalostomy: a new surgical technique for open angle glaucoma. An Inst Barraquer, Spain 25:229–232 Stegmann R (1995) Visco-canalostomy: a new surgical technique for open angle glaucoma. An Inst Barraquer, Spain 25:229–232
4.
Zurück zum Zitat Smit BA, Johnstone MA (2002) Effects of viscoelastic injection into Schlemm’s canal in primate and human eyes: potential relevance to viscocanalostomy. Ophthalmology 109:786–792CrossRefPubMed Smit BA, Johnstone MA (2002) Effects of viscoelastic injection into Schlemm’s canal in primate and human eyes: potential relevance to viscocanalostomy. Ophthalmology 109:786–792CrossRefPubMed
5.
Zurück zum Zitat Grieshaber MC, Grieshaber HR, Stegmann R (2016) A new expander for Schlemm canal surgery in primary open-angle glaucoma-interim clinical results. J Glaucoma 25:657–662CrossRefPubMed Grieshaber MC, Grieshaber HR, Stegmann R (2016) A new expander for Schlemm canal surgery in primary open-angle glaucoma-interim clinical results. J Glaucoma 25:657–662CrossRefPubMed
6.
Zurück zum Zitat Grieshaber MC (2017) Viscocanalostomy and canaloplasty: ab externo Schlemm’s canal surgery. Dev Ophthalmol 59:113–126CrossRefPubMed Grieshaber MC (2017) Viscocanalostomy and canaloplasty: ab externo Schlemm’s canal surgery. Dev Ophthalmol 59:113–126CrossRefPubMed
7.
Zurück zum Zitat Grieshaber MC, Stegmann R, Grieshaber HR, Meyer P (2015) Novel device for expanding Schlemm’s canal: a morphological study: implantation of the Stegmann Canal Expander following viscodilation of Schlemm’s canal resulted in permanent expansion of the canal lumen and distension of the trabecular meshwork without complications. Br J Ophthalmol 99:875–877CrossRefPubMed Grieshaber MC, Stegmann R, Grieshaber HR, Meyer P (2015) Novel device for expanding Schlemm’s canal: a morphological study: implantation of the Stegmann Canal Expander following viscodilation of Schlemm’s canal resulted in permanent expansion of the canal lumen and distension of the trabecular meshwork without complications. Br J Ophthalmol 99:875–877CrossRefPubMed
8.
Zurück zum Zitat Grieshaber MC (2018) Stegmann Canal Expander for canaloplasty: a novel technique. Eur J Ophthalmol 28(4):472–478CrossRefPubMed Grieshaber MC (2018) Stegmann Canal Expander for canaloplasty: a novel technique. Eur J Ophthalmol 28(4):472–478CrossRefPubMed
10.
Zurück zum Zitat Grieshaber MC, Pienaar A, Olivier J, Stegmann R (2009) Channelography: imaging of the aqueous outflow pathway with flexible microcatheter and fluorescein in canaloplasty. Klin Monatsbl Augenheilkd 226:245–248CrossRefPubMed Grieshaber MC, Pienaar A, Olivier J, Stegmann R (2009) Channelography: imaging of the aqueous outflow pathway with flexible microcatheter and fluorescein in canaloplasty. Klin Monatsbl Augenheilkd 226:245–248CrossRefPubMed
11.
Zurück zum Zitat Grieshaber MC, Pienaar A, Olivier J, Stegmann R (2010) Clinical evaluation of the aqueous outflow system in primary open-angle glaucoma for canaloplasty. Invest Ophthalmol Vis Sci 51:1498–1504CrossRefPubMed Grieshaber MC, Pienaar A, Olivier J, Stegmann R (2010) Clinical evaluation of the aqueous outflow system in primary open-angle glaucoma for canaloplasty. Invest Ophthalmol Vis Sci 51:1498–1504CrossRefPubMed
Metadaten
Titel
Flap-sparing canaloplasty: a modified approach to Schlemm’s canal
verfasst von
Matthias C. Grieshaber
Ané Pienaar
Robert Stegmann
Publikationsdatum
06.05.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 8/2019
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-019-04329-8

Weitere Artikel der Ausgabe 8/2019

Graefe's Archive for Clinical and Experimental Ophthalmology 8/2019 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.