Purpose

To evaluate image quality and diagnostic accuracy for acute infarct detection and radiation dose of 70 kVp whole brain CT perfusion (CTP) and CT angiography (CTA) reconstructed from CTP source data.

Methods

Patients were divided into three groups (n = 50 each): group A, 80 kVp, 21 scanning time points; groups B, 70 kVp, 21 scanning time points; group C, 70 kVp, 17 scanning time points. Objective and subjective image quality of CTP and CTA were compared. Diagnostic accuracy for detecting acute infarct and cerebral artery stenosis ≥ 50 % was calculated for CTP and CTA with diffusion weighted imaging and digital subtraction angiography as reference standards. Effective radiation dose was compared.

Results

There were no differences in any perfusion parameter value between three groups (P > 0.05). No difference was found in subjective image quality between three groups (P > 0.05). Diagnostic accuracy for detecting acute infarct and vascular stenosis showed no difference between three groups (P > 0.05). Compared with group A, radiation doses of groups B and C were decreased by 28 % and 37 % (both P < 0.001), respectively.

Conclusion

Compared with 80 kVp protocol, 70 kVp brain CTP allows comparable vascular and perfusion assessment and lower radiation dose while maintaining high diagnostic accuracy in detecting acute infarct.

Key Points

70 kVp whole brain CTP can provide diagnostic image quality.
70 kVp CTP diagnostic accuracy was maintained vs. 80 kVp protocol.
70 kVp CTP radiation doses were lower than 80 kVp protocol.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Aviv RI, d'Esterre CD, Murphy BD et al (2009) Hemorrhagic transformation of ischemic stroke: prediction with CT perfusion. Radiology 250:867–877CrossRefPubMed Aviv RI, d'Esterre CD, Murphy BD et al (2009) Hemorrhagic transformation of ischemic stroke: prediction with CT perfusion. Radiology 250:867–877CrossRefPubMed
2.
Zurück zum Zitat Hoang JK, Wang C, Frush DP et al (2013) Estimation of radiation exposure for brain perfusion CT: standard protocol compared with deviations in protocol. AJR Am J Roentgenol 201:W730–W734CrossRefPubMed Hoang JK, Wang C, Frush DP et al (2013) Estimation of radiation exposure for brain perfusion CT: standard protocol compared with deviations in protocol. AJR Am J Roentgenol 201:W730–W734CrossRefPubMed
3.
Zurück zum Zitat Ringelstein A, Lechel U, Fahrendorf DM et al (2014) Radiation exposure in perfusion CT of the brain. J Comput Assist Tomogr 38:25–28CrossRefPubMed Ringelstein A, Lechel U, Fahrendorf DM et al (2014) Radiation exposure in perfusion CT of the brain. J Comput Assist Tomogr 38:25–28CrossRefPubMed
4.
Zurück zum Zitat Li ZL, Li H, Zhang K et al (2014) Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV). Eur Radiol 24:1906–1913CrossRefPubMed Li ZL, Li H, Zhang K et al (2014) Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV). Eur Radiol 24:1906–1913CrossRefPubMed
5.
Zurück zum Zitat Corcuera-Solano I, McLellan AM, Doshi AH et al (2014) Whole-brain adaptive 70-kVp perfusion imaging with variable and extended sampling improves quality and consistency while reducing dose. AJNR Am J Neuroradiol 35:2045–2051CrossRefPubMed Corcuera-Solano I, McLellan AM, Doshi AH et al (2014) Whole-brain adaptive 70-kVp perfusion imaging with variable and extended sampling improves quality and consistency while reducing dose. AJNR Am J Neuroradiol 35:2045–2051CrossRefPubMed
6.
Zurück zum Zitat Luo S, Zhang LJ, Meinel FG et al (2014) Low tube voltage and low contrast material volume cerebral CT angiography. Eur Radiol 24:1677–1685CrossRefPubMed Luo S, Zhang LJ, Meinel FG et al (2014) Low tube voltage and low contrast material volume cerebral CT angiography. Eur Radiol 24:1677–1685CrossRefPubMed
7.
Zurück zum Zitat Cho ES, Chung TS, Oh DK et al (2012) Cerebral computed tomography angiography using a low tube voltage (80 kVp) and a moderate concentration of iodine contrast material: a quantitative and qualitative comparison with conventional computed tomography angiography. Invest Radiol 47:142–147CrossRefPubMed Cho ES, Chung TS, Oh DK et al (2012) Cerebral computed tomography angiography using a low tube voltage (80 kVp) and a moderate concentration of iodine contrast material: a quantitative and qualitative comparison with conventional computed tomography angiography. Invest Radiol 47:142–147CrossRefPubMed
8.
Zurück zum Zitat Lin CJ, Wu TH, Lin CH et al (2013) Can iterative reconstruction improve imaging quality for lower radiation CT perfusion? Initial experience. AJNR Am J Neuroradiol 34:1516–1521CrossRefPubMed Lin CJ, Wu TH, Lin CH et al (2013) Can iterative reconstruction improve imaging quality for lower radiation CT perfusion? Initial experience. AJNR Am J Neuroradiol 34:1516–1521CrossRefPubMed
9.
Zurück zum Zitat Abels B, Klotz E, Tomandl BF et al (2010) Perfusion CT in acute ischemic stroke: a qualitative and quantitative comparison of deconvolution and maximum slope approach. AJNR Am J Neuroradiol 31:1690–1698CrossRefPubMed Abels B, Klotz E, Tomandl BF et al (2010) Perfusion CT in acute ischemic stroke: a qualitative and quantitative comparison of deconvolution and maximum slope approach. AJNR Am J Neuroradiol 31:1690–1698CrossRefPubMed
10.
Zurück zum Zitat Abels B, Klotz E, Tomandl BF et al (2011) CT perfusion in acute ischemic stroke: a comparison of 2-second and 1-second temporal resolution. AJNR Am J Neuroradiol 32:1632–1639CrossRefPubMed Abels B, Klotz E, Tomandl BF et al (2011) CT perfusion in acute ischemic stroke: a comparison of 2-second and 1-second temporal resolution. AJNR Am J Neuroradiol 32:1632–1639CrossRefPubMed
11.
Zurück zum Zitat Chen GZ, Zhang LJ, Schoepf UJ et al (2015) Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography. Eur Radiol 25:1453–1463CrossRefPubMed Chen GZ, Zhang LJ, Schoepf UJ et al (2015) Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography. Eur Radiol 25:1453–1463CrossRefPubMed
12.
Zurück zum Zitat Haubenreisser H, Fink C, Nance JW Jr et al (2015) Feasibility of slice width reduction for spiral cranial computed tomography using iterative image reconstruction. Eur J Radiol 83:964–969CrossRef Haubenreisser H, Fink C, Nance JW Jr et al (2015) Feasibility of slice width reduction for spiral cranial computed tomography using iterative image reconstruction. Eur J Radiol 83:964–969CrossRef
13.
Zurück zum Zitat Saake M, Goelitz P, Struffert T et al (2012) Comparison of conventional CTA and volume perfusion CTA in evaluation of cerebral arterial vasculature in acute stroke. AJNR Am J Neuroradiol 33:2068–2073CrossRefPubMed Saake M, Goelitz P, Struffert T et al (2012) Comparison of conventional CTA and volume perfusion CTA in evaluation of cerebral arterial vasculature in acute stroke. AJNR Am J Neuroradiol 33:2068–2073CrossRefPubMed
14.
Zurück zum Zitat Suzuki K, Morita S, Masukawa A et al (2011) Utility of CT perfusion with 64-row multi-detector CT for acute ischemic brain stroke. Emerg Radiol 18:95–101CrossRefPubMed Suzuki K, Morita S, Masukawa A et al (2011) Utility of CT perfusion with 64-row multi-detector CT for acute ischemic brain stroke. Emerg Radiol 18:95–101CrossRefPubMed
15.
Zurück zum Zitat Hoeffner EG, Case I, Jain R et al (2004) Cerebral perfusion CT: technique and clinical applications. Radiology 231:632–644CrossRefPubMed Hoeffner EG, Case I, Jain R et al (2004) Cerebral perfusion CT: technique and clinical applications. Radiology 231:632–644CrossRefPubMed
16.
Zurück zum Zitat Nabavi DG, Cenic A, Craen RA et al (1999) CT assessment of cerebral perfusion: experimental validation and initial clinical experience. Radiology 213:141–149CrossRefPubMed Nabavi DG, Cenic A, Craen RA et al (1999) CT assessment of cerebral perfusion: experimental validation and initial clinical experience. Radiology 213:141–149CrossRefPubMed
18.
Zurück zum Zitat Cohen J (1960) A coefficient of agreement for nominal scales. Educ Psychol Meas 20:37–46CrossRef Cohen J (1960) A coefficient of agreement for nominal scales. Educ Psychol Meas 20:37–46CrossRef
19.
Zurück zum Zitat Funama Y, Awai K, Nakayama Y et al (2005) Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 237:905–910CrossRefPubMed Funama Y, Awai K, Nakayama Y et al (2005) Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 237:905–910CrossRefPubMed
20.
Zurück zum Zitat Yamamura S, Oda S, Imuta M et al (2015) Reducing the radiation dose for CT colonography: effect of low tube voltage and iterative reconstruction. Acad Radiol S1076–6332(15):00130 Yamamura S, Oda S, Imuta M et al (2015) Reducing the radiation dose for CT colonography: effect of low tube voltage and iterative reconstruction. Acad Radiol S1076–6332(15):00130
21.
Zurück zum Zitat Zhang LJ, Wang Y, Schoepf UJ (2015) Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography. Eur Radiol. doi:10.1007/s00330-015-3868-z Zhang LJ, Wang Y, Schoepf UJ (2015) Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography. Eur Radiol. doi:10.​1007/​s00330-015-3868-z
22.
Zurück zum Zitat Cho ES, Chung TS, Ahn SJ (2015) Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose. Eur Radiol 25:1421–1430CrossRefPubMed Cho ES, Chung TS, Ahn SJ (2015) Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose. Eur Radiol 25:1421–1430CrossRefPubMed
23.
Zurück zum Zitat Durand S, Paul JF (2014) Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT. Eur Radiol 24:3003–3009CrossRefPubMed Durand S, Paul JF (2014) Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT. Eur Radiol 24:3003–3009CrossRefPubMed
24.
Zurück zum Zitat Zhang LJ, Qi L, Wang J (2014) Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience. Eur Radiol 24:1537–1546CrossRefPubMed Zhang LJ, Qi L, Wang J (2014) Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience. Eur Radiol 24:1537–1546CrossRefPubMed
25.
Zurück zum Zitat Kloska SP, Fischer T, Sauerland C et al (2010) Increasing sampling interval in cerebral perfusion CT: limitation for the maximum slope model. Acad Radiol 17:61–66CrossRefPubMed Kloska SP, Fischer T, Sauerland C et al (2010) Increasing sampling interval in cerebral perfusion CT: limitation for the maximum slope model. Acad Radiol 17:61–66CrossRefPubMed
26.
Zurück zum Zitat Khatri P, Yeatts SD, Mazighi M et al (2014) Time to angiographic reperfusion and clinical outcome after acute ischaemic stroke: an analysis of data from the Interventional Management of Stroke (IMS III) phase 3 trial. Lancet Neurol 13:567–574CrossRefPubMedPubMedCentral Khatri P, Yeatts SD, Mazighi M et al (2014) Time to angiographic reperfusion and clinical outcome after acute ischaemic stroke: an analysis of data from the Interventional Management of Stroke (IMS III) phase 3 trial. Lancet Neurol 13:567–574CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Frölich AM, Psychogios MN, Klotz E et al (2012) Angiographic reconstructions from whole-brain perfusion CT for the detection of large vessel occlusion in acute stroke. Stroke 43:97–102CrossRefPubMed Frölich AM, Psychogios MN, Klotz E et al (2012) Angiographic reconstructions from whole-brain perfusion CT for the detection of large vessel occlusion in acute stroke. Stroke 43:97–102CrossRefPubMed
28.
Zurück zum Zitat Ho CY, Hussain S, Alam T et al (2013) Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software. Emerg Radiol 20:203–212CrossRefPubMedPubMedCentral Ho CY, Hussain S, Alam T et al (2013) Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software. Emerg Radiol 20:203–212CrossRefPubMedPubMedCentral
Metadaten
Titel
Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study
verfasst von
Xiao Kun Fang
Qian Qian Ni
U. Joseph Schoepf
Chang Sheng Zhou
Guo Zhong Chen
Song Luo
Stephen R. Fuller
Carlo N. De Cecco
Long Jiang Zhang
Guang Ming Lu
Publikationsdatum
06.02.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 11/2016
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-016-4225-6

Weitere Artikel der Ausgabe 11/2016

European Radiology 11/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.