Skip to main content
Erschienen in: Insights into Imaging 1/2014

Open Access 01.02.2014 | Review

Imaging in Transcatheter Aortic Valve Replacement (TAVR): role of the radiologist

verfasst von: Diana E. Litmanovich, Eduard Ghersin, David A. Burke, Jeffrey Popma, Maryam Shahrzad, Alexander A. Bankier

Erschienen in: Insights into Imaging | Ausgabe 1/2014

Abstract

Background

Transcatheter aortic valve replacement (TAVR) is a novel technique developed in the last decade to treat severe aortic stenosis in patients who are non-surgical candidates because of multiple comorbidities.

Methods

Since the technique is performed using a transvascular approach, pre-procedural assessment of the aortic valve apparatus, ascending aorta and vascular access is of paramount importance for both appropriate patient selection and correct device selection. This assessment is performed by a multi-disciplinary team with radiology being an integral and important part.

Results

Among imaging modalities, there is growing scientific evidence supporting the crucial role of MDCT in the assessment of the aortic valve apparatus, suitability of the iliofemoral or alternative pathway, and determination of appropriate coaxial angles. MDCT also plays an important role in post-procedure imaging in the assessment of valve integrity and position.

Conclusion

This review outlines the principal aspects of TAVR, the multidisciplinary approach and utilisation of different imaging modalities, as well as a step-by-step approach to MDCT acquisition protocols, reconstruction techniques, pre-procedure measurements and post-procedure assessment.

Teaching Points

TAVR is a new technique to treat severe aortic stenosis in high-risk and nonsurgical candidates.
MDCT assessment of the aortic annulus is important for appropriate patient and device selection.
Multidisciplinary approach is required for patient selection, procedure planning and performance.
MDCT is required for assessment of the aortic root, iliofemoral or alternative vascular pathway.

Introduction

Aortic stenosis is the most common valvular disorder in developed countries, affecting 2–5 % of the population over 75 years old [1, 2]. Once symptoms develop, the mortality increases rapidly to approximately 50 % within 2 years [3, 4]. The standard of care in treatment of patients with symptomatic severe aortic stenosis remains surgical aortic valve replacement (sAVR), which has low peri-operative mortality and improved clinical outcomes [5]. However, high-risk patients often have significant comorbidities such as coronary heart disease, renal insufficiency, lung disease, cerebrovascular disease or frailty that limit their chance of survival [6, 7]. The most commonly used scoring tool to estimate 30-day mortality after cardiac surgery is the Society for Thoracic Surgery Predicted Risk of Mortality score (STS PROM) [8]. For the patient population considered unsuitable or at high-risk for sAVR because of underlying comorbidities, the development of transcatheter aortic valve replacement (TAVR) has resulted in an alternative therapy for symptom relief and extension of life [9].

Aortic valve apparatus anatomy

The aortic valve complex consists of the aortic valve annulus, commissures, sinuses of Valsalva (SOV), coronary ostia (CO) and sinotubular junction (STJ). Three aortic valve cusps are connected proximally to the wall of the left ventricular outflow tract (LVOT) [10] by three anchor points at the nadir (hinge point) of each aortic cusp. Those nadir points, when virtually connected, form an oval-shaped, three-pronged coronet—the “virtual basal ring” (Fig. 1). The orientation of this virtual basal ring, or aortic annulus, is double oblique and does not correspond to conventional axial, coronal or sagittal planes of MDCT. This ring is the major target for transcatheter aortic valve prosthesis sizing.
Distally, the three semilunar leaflets are attached to the wall of the aortic sinus at the surgical annulus that corresponds to the sinotubular junction: the junction between the SOV and ascending aorta. Multiple manipulations of the raw imaging data are required to create an image that would exactly correspond to the aortic annulus (virtual basal ring). This virtual basal ring is often not orthogonal to the LVOT, and insertion of the right coronary cusp can often be inferior to the left and non-coronary cusps [11].

TAVR: review of the device and procedure

There are currently two transcatheter heart valves (THVs) available for use in the US: the Edwards SAPIEN valve (Fig. 2) and the Medtronic CoreValve prosthesis (CoreValve) (Fig. 3). Both devices were granted Conformité Européenne (CE) approval in Europe in 2007, and the Edwards SAPIEN valve was approved for commercial use in the US in 2011 following the landmark PARTNER trial [12, 13]. The CoreValve device is currently available in research trials only. The main characteristics of both devices are summarised in Tables 1 and 2, with some specific features outlined below. Both devices are predominately delivered through a transfemoral approach involving either percutaneous or surgical cutdown for arterial access (Fig. 4).
Table 1
Comparison of the Edwards SAPIEN XT and Medtronic CoreValve Prostheses
Characteristics
Edwards SAPIEN XT
Medtronic CoreValve
Frame
Cobalt chromium
Nitinol
Leaflets
Bovine pericardial
Porcine pericardial
Expansion
Balloon expandable
Self-expanding
Repositionable
No
Yes
Retrievable
No
Yes
Annular/valvular fixation
Yes
Yes
Ascending aorta fixation
No
Yes
Sheath internal diameter
18-F, 19-F
18-F
Sheath external diameter
7 mm
7 mm
Minimal arterial diameter
6 mma
6 mm
Suitable for
 Dilated ascending aorta
Yes
No
 Transapical access
Yes
No
 Transaxillary access
Yes, limited experience
Yes, limited experience
 Transaortic access
Yes
Yes
Longest published follow-up
>6 years
>4 years
Pacemaker requirement
3 %–8 %
14 %–40 %
FDA approval
SAPIEN transfemoral only
No
Randomised trial results
PARTNER A and B
Results anticipated 2013
aEdwards SAPIEN XT 29 mm requires peripheral vessel patent lumen diameter of >7 mm
Modified from [63]
Table 2
Optimal aortic annulus, aortic root and peripheral vessel lumen dimensions for different types and sizes of THV
 
Aortic annulus diameter, mm
Distance aortic annulus to left main ostium, mm
Ascending aorta diameter, mm
Sinus of Valsalva height/width, mm
Peripheral vessels patent lumen diameter, mm
Valve height, mm
Edwards SAPIEN XT 23 mm
18–22
≥10
  
>6
14.3
Edwards SAPIEN XT 26 mm
21–25
≥10
  
>6.5
17.2
Edwards SAPIEN XT 29 mm
24–27
≥10
  
>7.0
19.1
Medtronic CoreValve 23 mm
18–20
 
≤40
≥15/≥27
>6
45
Medtronic CoreValve 26 mm
20–23
 
≤40
≥15/≥27
>6
53
Medtronic CoreValve 29 mm
23–27
 
≤43
≥15/≥29
>6
55
Medtronic CoreValve 31 mm
26–29
 
≤43
≥15/≥29
>6
52
THV transcatheter heart valves
Modified from [11] and [63]
The Edwards SAPIEN is a ballon-expandable stent. The earlier generation valve is available in 23- and 26-mm valve sizes and is delivered via a 22- or 24-French delivery system, respectively. A newer version, the SAPIEN XT, is available in 23-, 26- and 29-mm sizes using a smaller transfemoral delivery sheath system (18 and 19 French, which requires a minimal iliofemoral luminal diameter of 6 mm). Due to its short stent frame length, the Edwards SAPIEN valve can be deployed in the aortic annulus without any significant limitations in terms of sinus of Valsalva size, sinotubular junction or ascending aortic diameter. The balloon-expandable frame assumes its shape with a single inflation, and the aortic annulus typically conforms to the shape of the device with a more circular geometry (Fig. 5).
Available in 23-, 26-, 29- and 31-mm sizes, the Medtronic CoreValve device (Table 1) is a self-expanding prosthetic valve requiring an 18-French delivery catheter (a minimal iliofemoral luminal diameter of 6 mm). The longer CoreValve device frame requires sufficient ‘outflow’ room to be deployed but the device is available in a wider range of sizes allowing patients with particularly larger annular diameters to be treated. The radial force of the self-expanding frame holds the device in position at the level of the annulus. This same radial force is thought to increase the need for a permanent pacemaker because of compression on conduction tissues, an issue more prevalent with the CoreValve device.
Depending on the specific device, there are several potential additional vascular access routes for implantation [14]:
(1)
The transapical approach is the second most common access route for TAVR using the Edwards SAPIEN valve (Fig. 6). It essentially affords a direct path to the aortic valve via surgical thoracotomy. While refinements in apical-purse string suturing techniques have reduced bleeding complications, this remains an invasive approach in elderly frail patients.
 
(2)
The direct aortic approach was originally developed for use with the CoreValve device as the larger stent frame precluded the transapical route. Although this still requires a partial sternotomy or right anterior thoracotomy, this is arguably less invasive than the incision required for the transapical route and is gaining favour (Fig. 7) [15].
 
(3)
The subclavian/axillary approach was originally developed for use with the CoreValve device; it can be used for the Edwards SAPIEN prosthesis. With CoreValve device this approach has been losing ground to direct aortic access in recent years. Disruption and dissection are more common with catheter manipulation in the subclavian artery, and caution is required in patients with previous coronary artery bypass grafting in which the left internal mammary artery was used [16, 17]. There are reports describing brachiocephalic access as an alternative approach [18].
 
TAVR is performed with cardiac surgery back-up and typically general anaesthesia is used. Imaging during the procedure is crucial for accurate device positioning, assessing prosthetic valve function and efficient detection of procedural complications. Positioning of the prosthetic valve is aided by pre-determination of the annular plane orientation using pre-procedure MDCT and rotational angiography with fluoroscopy during the procedure (Fig. 8). Transesophageal echocardiography (TEE) plays an important role in device positioning, final placement and determiningTransoesophageal degree of aortic regurgitation following deployment (Fig. 9). Main procedure risks and complications include vascular access complications, aortic valve regurgitation, transvalvular and paravalvular, stroke, conduction system abnormalities, prosthesis embolisation, mitral valve disruption, haemorrhage, peripheral vascular complications and death [19, 20].

Patient selection for TAVR suitability

Currently TAVR is reserved for patients with symptomatic severe aortic stenosis in whom pre-existing comorbidities increase the risk of sternotomy and standard valve replacement, and who are considered high or very high surgical risk (Table 3). Aortic annular size appropriate for any of the existing THV devices is an important inclusion criterion. Multiple objective estimates of surgical mortality are applied in the selection process of patients referred for TAVR [2123]. A logistic EuroSCORE (European System of Cardiac Operative Risk Evaluation) of 20 points or a Society of Thoracic Surgeons Score of 10 points is often used as a risk threshold to aid in decision making [23]. As of 2013, there had been more than 40,000 transcatheter valvular replacements performed worldwide and approximately 7,000 cases performed in the US.
Table 3
Inclusion and exclusion criteria for TAVR
Inclusion criteria:
 Critical aortic stenosis (with mean aortic valve area of <0.8 cm2)
 Multiple comorbidities with 1-year mortality rate exceeding 20 %
 Poor outcome with medical management
 Non-surgical candidates with TAVR representing the only suitable alternative
 Native aortic annular size appropriate for currently available THV size criteria
Exclusion criteria: unsuitable native anatomy
 Lack of appropriate access to implant the device
 Sinuses of Valsalva unable to accommodate prosthetic valve
 Native aortic annular size inappropriate for currently available THV size criteria
Annular size not corresponding to any of the available THV devices would be a major exclusion criterion, followed by the lack of an appropriate vascular access route; for the CoreValve device, this criterion would be sinus of Valsalva dimensions too small or too large to accommodate the upper frame when positioned (Table 3).

Pre-TAVR assessment of aortic root anatomy with echocardiography and MDCT

Two- and three-dimensional transthoracic (TTE), transesophageal echocardiography (TEE), ECG-gated MDCT and rarely cardiac magnetic imaging (CMR) (Figs. 10 and 11) can be used for aortic valve apparatus assessment, with each imaging technique providing complementary information for optimal valve prosthesis sizing and THV selection. TTE, TEE and MDCT are currently the primary modalities for aortic root anatomy assessment.

Echocardiography assessment

Echocardiography is used to confirm severe aortic stenosis (aortic valve area of <0.8 cm2, peak velocity across valve >4 m/s and mean gradient >40 mmHg). It is also used to assess the degree of aortic incompetence and other valvular diseases, left ventricular systolic ejection fraction and diastolic dysfunction, as well as to estimate right-sided and pulmonary pressures. For TTE, the para-sternal long-axis view is used, and for TEE, the mid-esophageal long-axis view is used. The annulus is measured during early systole, with the valve leaflets open, from the hinge point of the right coronary leaflet to the hinge point of the non-coronary leaflet. THree-dimensional TEE may provide more accurate assessments of the aortic annulus compared to 2D-TEE, which may impact prosthesis size selection, although more research in this area is needed [24, 25]. Despite promising results and crucial information, 3D TEE is not yet a standard practice in pre-TAVR aortic annulus measurement assessment. TEE allows for real-time imaging during the TAVR procedure while assisting in device placement and positioning as well as assessing the degree of aortic regurgitation [12]. Other complications such as pericardial tamponade, severe mitral regurgitation, aortic dissection, LV damage and embolisation of the implanted valve can also be diagnosed intra-procedurally with TEE. [12].

MDCT assessment

The Society of Cardiac Computed Tomography (SCCT) expert consensus document on MDCT imaging before TAVR suggests using at least a 64-detector scanner, with an obvious advantage of 128, 256 and 320 slice scanners with their shortened acquisition time and decreased contrast volume [11, 26] and high-pitch spiral dual-source CT angiography protocol [27]. Imaging should be performed in the supine position and during suspended respiration [11]. Since precision in the range of 1 mm is desirable, spatial resolution must be high with an acquisition protocol that obtains a reconstructed slice width of ≤1.0 mm throughout the entire imaging volume, particularly of the aortic valve, aortic root and ilio-femoral arteries.

Aortic annulus apparatus imaging

For precise aortic valve annular sizing and root evaluation, ECG-gated CT angiograms of the ascending aorta and heart are obtained with either prospective or retrospective ECG triggering. Aortic valve and root assessment during systole has been shown to be preferable to during diastole because of the larger annular size noted in systole as well as dynamic changes [28, 29]. Thus, with both prospective and retrospective gating, the data should be acquired during systole (usually 20–50 % phase of the cardiac cycle) with no radiation during the rest of the cycle in prospective ECG triggering and very aggressive dose modulation with retrospective gating, allowing substantial dose savings. No routine administration of β-blockers is used for scanning purposes because of concerns with underlying severe aortic stenosis. A high incidence of arrhythmia in TAVR candidates precludes routine use of prospective gating on a routine basis. As a result, the estimated radiation dose may be relatively high, but acceptable given the advanced age of the vast majority of TAVR candidates and the amount of information acquired. For younger patients, with stable and low heart rates, prospective axial acquisition during the systolic phase is suggested [26]. Tube potential of 100 kV is suggested for patients weighing less than 90 kg or with a body mass index (BMI) less than 30, whereas a tube potential of 120 kV is usually indicated for patients weighing more than 90 kg (BMI >30). The lowest setting possible should be selected in keeping with acceptable image noise [30].
Image acquisition triggering can be obtained automatically or by using a bolus injection technique for determining the transit time. The region of interest (ROI) can be placed on the proximal descending aorta using a pre-selected HU threshold. Arterial enhancement in studies performed with a 64-slice scanner demonstrates more consistency with the bolus injection technique, but requires higher contrast volume (typically an additional 20 ml of contrast medium). The vast majority of medical centres imaging TAVR candidates follow one of the two two-step protocols (Table 4). Reduction of contrast volume can be achieved by using lower flow rates such as 3 ml/s or less [31]. Dual-energy techniques allow adequate enhancement with lower intravenous contrast volumes [32]. In extreme cases of renal insufficiency, direct aortic injection with extremely low volumes of contrast (,20 ml) can be used [33, 34].
Table 4
Suggested IV contrast injection regiments
64-Detector scanner
320-Detector scanner
Gated cardiac CTA
Gated CTA chest
Bolus injection, 20 ml IV contrast
Automatic triggering
ROI: proximal descending aorta
ROI: proximal descending aorta
Peak enhancement selected
Threshold of +200 HU used
Main injection: 4 ml/s, 70–80 ml
Rate: 4 ml/s, 120–140 ml
Non-gated CTA abdomen, pelvis
Non-gated CTA abdomen, pelvis
Additional 50 ml is injected
Done immediately after chest CTA
Injection timing based on bolus results
No additional IV contrast required
Total:
Total:
130–150 ml
120–140 ml
ROI Region of interest
Image reconstruction of the aortic valve apparatus requires a complex reconstruction technique based purely on aortic valve anatomy. No single image reconstruction protocol exists, but similarities between clinical centres and approaches exist. Currently the most widely used method for reconstruction of aortic valve annulus is based on sequential double-oblique reconstructions that ultimately provide the image corresponding to the aortic valve annulus. The post-processing approach used for assessment of the aortic root and ascending aorta has been described in detail by Achenbach et al. and Leipsic et al. (Fig. 12) [11, 26]. As with all other types of CT post-processing, the quality and precision of reconstructed images depend on the quality of the raw CT data. The presence of a high heart rate, arrhythmia and severe valve calcifications can substantially degrade image quality (Fig. 13). If these limitations present, they should be addressed in the report, and a decision should be made on the necessity of repeated imaging or acquiring the data with alternative imaging modalities.
Measurements of the aortic valve as well as qualitative assessment should be done based on properly reconstructed images (see above). Three main measurements have been suggested as being most informative regarding aortic annular sizing and THV selection (Table 5) (Fig. 14): (1) Aortic annulus diameters: long and short diameters are measured, and the mean diameter is calculated by averaging short and long diameters [35]. (2) The circumference (perimeter) of the aortic annulus can be either calculated under the assumption that the area corresponds to full circularity or measured manually (Fig. 15). (3) Aortic annulus area can be calculated based on the mean diameter or measured manually using the planimetry technique. Aortic annulus dimensions should be measured in systole, similar to echocardiography, since both the area and mean diameters are larger in systole [36]. No substantial difference in circumference was found across the cardiac cycle [26, 37].
Table 5
Aortic valve apparatus/ascending aorta measurements pertinent for TAVR
Aortic annulus (AA) (virtual basal ring)
 • AA maximal diameter
 • AA perpendicular minimal diameter
 • AA average diameter
 • AA cross-sectional area (CSA)
 • AA circumference
Aortic valve
 • Cuspidity
 • Comissure calcifications
 • Aortic annulus calcifications
 • Severely calcified cusp that might compromise coronary the artery ostia: yes/no
Ascending aorta
 • Width at 40 mm from the annulus
 • Position relative to the sternum
Sinuses of Valsalva
 • Maximum diameter
 • Height
 • Sinotubular junction maximum diameter
 • Distance from the aortic annular plane to the coronary artery ostia
Additional aortic valve apparatus measurements pertinent for TAVR dimensions include the aortic valve cusps, aortic valve commissures, sinuses of Valsalva, coronary ostia and sinotubular junction. The parameters important for pre-TAVR assessment are summarised in Table 6. The most important factors are discussed below.
Table 6
Crucial factors for assessing the aortic and peripheral vascular access
Minimal patent arterial luminal short axis diameters
 • Aorta
 • Common iliac arteries
 • External iliac arteries
 • Common femoral arteries
 • Subclavian arteries
 • Innominate artery
Arterial tortuosity
 • Mild, moderate, severe
 • Kinking (tortuosity >90º)
 • Obstruction/thrombosis
Arterial calcification
 Extent
  • Mild, moderate, severe
 Pattern
  • Circumferential
  • Horseshoe
  • At bifurcations
 • Arterial dissection
 • Yes/no
Arterial complex atheromas
 • Yes/no
Aortic valve calcifications (AVCs) are either diffusely or focally located on the aortic surface of thickened aortic valve cusps. If excessive, these calcifications may prevent appropriate alignment of the prosthesis, leading to gaps between the prosthetic valve and the aortic annulus and subsequent paravalvular aortic regurgitation (leak), as well as increased risk of annular rupture, device dislodgement or obstruction of coronary ostia due to opposition of calcified aortic cusp [34, 3842] (Fig. 16). Calcification of the aortomitral continuity may increase the risk of annular rupture with balloon dilatation (Fig. 17). AVC can be assessed in the cross-sectional view of the sinus of Valsalva (SOV) either qualitatively (mild, moderate, severe) or quantitatively using Agatston units (Agatston Score), the calcified volume score (in mm3) or mass score (in mg of CAHA), similar to the assessment of coronary calcifications [38, 43]. Agatston scores exceeding 3,000 are correlated with an increased incidence of paravalvular regurgitation after TAVR [44]. Semiquantitative scores assess the number of affected cusps, homogeneous versus more focal distribution of calcium and involvement of coronary versus non-coronary cusps. Calcium burden is quantified at the aortic annulus and at the SOV at both its inferior portion and superior aspect. Post-deployment balloon dilatation is required more frequently in patients with severe valvular calcification [45].
Distance of the coronary ostia to the aortic annulus plane: Coronary arteries generally arise within the SOV, below the level of the sinotubular junction (STJ). The right coronary artery generally lies higher than the left coronary artery, with average distance between the plane of the aortic annulus and coronary artery ostium (CAO) of 15.5 mm on the left and 17.3 mm on the right [46]. Degenerative aortic stenosis may result in longitudinal remodeling of the SOV with decreased distance from the aortic valve annulus to the CAO (Fig. 18). The combination of a relatively low-lying coronary artery ostium and a large native aortic valve leaflet can therefore obstruct the flow into the coronary arteries during device deployment. The height of the CAO is determined by identifying the origin of the coronary artery from the cross-section MPR and then measuring the vertical distance between the inferior edge of the CAO and the aortic annular plane. If coronary ostia height is more than 10–14 mm in patients with planned THV implantation, the chance of obstruction is low [11].
The width and maximal height of the SOV are important parameters for coronary perfusion with THV, determining whether the THV will be accommodated within the SOV without causing coronary occlusion from displacement of the native aortic valve leaflets [47] (Fig. 19). As for the rest of the aortic valve apparatus, measurements of the aortic sinus diameter and height should be assessed on a double-oblique projection. The SOV width assessment is particularly important for the CoreValve device with a minimum 27 mm required for the 26-mm prosthesis and 29 mm for the 29- and 31-mm prostheses; the minimum SOV height is 15 mm (Table 6) [26].
The diameter of the ascending aorta: For CoreValue devices, orientation of the direction of the device flow occurs when the frame contacts the inner and outer curvature of the aorta. Ascending aortic dilatation of more than 43 mm (when measured 4 cm above the basal aortic annulus plane) precludes the use of the 29- and 31-mm CoreValve device. Dilatation of more than 40 mm precludes the use of the 23- and 26-mm CoreValve device. Size is of less concern for valves that are short in length and confined to the aortic annulus and sinus of Valsalva such as the Edwards SAPIEN valve [11].
Additional features that might interfere with successful implantation: The left ventricular outflow tract (LVOT) is the area between the basal annulus and the anatomic aortoventricular junction. The atrioventricular (AV) node is located adjacent to the membranous septum of the LVOT below the aortic valve. Deep positioning of the THV into the LVOT may cause injury to the interventricular septal and artrioventricular conduction system. The degree of LV upper septal hypertrophy protruding into the LVOT can hinder accurate placement of the valve and present a significant risk of THV repositioning. The aortoventricular angle is the angle between the proximal aorta, aortic annulus and LVOT (Fig. 20). This angle is determined by the angle of the horizontal plane and the angle of the aortic annulus [26]. The aortoventricular angle is an important consideration when using THVs that are long in length and require deployment perpendicular to the native annular plane. Each type of THV has a maximum aortoventricular angle for successful valve deployment, typically 70º for the iliofemoral approach and 30º for the subclavian approach, due to angulation from the right subclavian into the ascending aorta.

Peripheral vascular pathway, aorta, chest wall and left heart imaging

Imaging of peripheral access can be obtained with non-gated spiral acquisition to minimise radiation. Peripheral access includes the iliofemoral, transsubclavian, transapical and direct aortic access routes. Transapical and direct aortic access (ascending aorta) routes are assessed with the ECG-gated portion of the MDCT. The common femoral artery should be included in the field of view when assessing femoral access. Assessment of the axillary and subclavian arteries should be obtained with the patient’s arms placed along his/her body to exclude pseudo narrowing of the imaged vasculature.
MDCT findings crucial in the peripheral vascular pathway assessment are summarised in Tables 1, 2 and 6. MDCT selection of patients with appropriate peripheral access has substantially reduced the risk of vascular complications from 30.1 % [12] to 8 % [48]. A sheath-to-femoral artery ratio ≥1.05 has been shown to be associated with increased vascular complications and 30-day mortality [36, 48]. A standardised approach for peripheral access has been developed, adding significant reduction in vascular injury rates [48]. Accepted practice is to evaluate peripheral access with several reconstruction techniques: curved multiplanar reconstructions (MPR), 3D volume-rendered images and, if necessary, maximum intensity projection (MIP) images (Fig. 21). These multiple measurements are taken along the common iliac, external iliac, common femoral, innominate, subclavian and proximal axillary arteries bilaterally.
Vessel tortuosity in the iliofemoral or brachiocephalic/subclavian arteries can be optimally assessed using 3D reconstructions, with multiple oblique views seen along the 360° circle in addition to the anterior-posterior view. Precise angle measurements are obtained using PACS or workstation angle measurement tools. Note that vessel angulation of 90° or more may be a contraindication for large-bore catheter insertion (Fig. 22). The burden and pattern of vascular calcifications and presence of circumferential or horseshoe calcification can be better assessed on curved multiplanar and maximum intensity projection (MIP) reconstructions. The combination of relatively small vessel caliber or stenotic segments with these types of vascular calcifications is a relative contraindication for a transfemoral approach. However, a relatively straight segment with no substantial calcification or atheroma can be cannulated even if marginally smaller in diameter than the intended sheath [49]. The presence of dissection or a complex atheroma is assessed on both axial and curved reconstruction images, with such findings again considered contraindications for a transfemoral approach. If the iliofemoral approach is not an option for a given patient, transapical, direct aortic, direct brachiocephalic or subclavian artery approaches should be assessed (Figs. 23 and 24).
For all TAVR approaches, assessment of the entire aorta is done routinely as part of the pre-procedure protocol using curved MPR with subsequent creation of true perpendicular axial images for precise patent lumen diameter assessment. For the transfemoral approach, the aorta is assessed to exclude the presence of an abdominal aneurysm, elongation with kinking of the aorta, dissection or large thrombi protruding into the lumen and/or complex atheromas, as these are contraindications for transfemoral approach [11]. For the direct aortic approach, assessment of the ascending aorta for the presence and pattern of calcification is of paramount importance, as calcium may interfere with direct puncture of the aorta. In these cases, the ascending aorta from the aortic annulus plane to the origin of the brachiocephalic artery is assessed for the presence of aneurysmatic dilatation or circumferential/anterior calcifications (Fig. 25). The relationship between the aorta and chest is important for planning thoracic chest wall incisions. It is important to assess the retrosternal area for the presence of masses particularly in post-CABG patients to avoid bypass graft injury. After median sternotomy or a right parasternal incision has been performed for the direct aortic approach, the aorta is punctured either through its anterior or right lateral aspects (accordingly), usually within the most proximal 8.5 cm, to allow sufficient room for CoreValve device expansion. MDCT reconstructions routinely include 3D VR reconstructions with osseous structures providing anatomic landmarks for future thoracotomy. For transapical access, assessment of the entire aorta is less crucial, unless a change in the approach is anticipated during the procedure. The crucial data are the position of the left ventricle (LV) apex relative to the chest wall and alignment of the LV axis with the LV outflow tract. Also, left atrial (LA) and/or LV thrombi can be a source of embolic complications that will need to be identified and reported. As with the direct aortic approach, chest deformities and mediastinal lesions are important and should be reported and reviewed with the team prior to the procedure.

Comparative analysis of echocardiography vs. MDCT for aortic valve apparatus assessment

Historically, patient eligibility for transcatheter valve therapy and sizing of the prosthesis were largely based upon aortic annulus measurements on 2D echocardiography (transthoracic or transesophageal) and occasionally on angiography. The major disadvantage of these techniques [5052] is the underestimation of the oval and not circular shape of the aortic annulus (Figs. 26 and 27) [20]. Direct comparison of TEE and MDCT aortic annulus measurements is problematic because of different parameter measures by each of the modalities. Aortic annulus diameter on coronal view by MDCT has been shown to be significantly larger than that obtained on sagittal view by MDCT, TTE or TEE [53]. Long-axis measurement of the aortic annulus by TTE and TEE approximates the minor axis of the elliptically shaped annulus as measured by MDCT (Fig. 28). Thus, consistently larger measurements obtained with MDCT as compared with 2D echocardiography most likely reflect the measurements of the largest of the two diameters of this oval-shaped annulus as opposed to the smaller one measured by echocardiography [5456]. The 2D echocardiography usually underestimates the aortic annulus average diameter by 1 ± 1.7 mm [26, 52]. As a result of the eccentric geometry of the oval aortic annulus, correlative studies have shown a systematic underestimation of annular sizing by 2D echocardiography alone [57].
MDCT can provide better estimates of both the long- and short-axis diameter of the aortic annulus, surface area and perimeter measurements. Extensive work has been done to establish the role of MDCT in aortic annular sizing with Edward Sapiens transcatheter heart valves (THV) [11, 26, 46]. While exaggerated oversizing of the THV and excessive calcification of the native aortic valve can result in aortic annular rupture, some THV oversizing is required for both types of THV to prevent PAR. For the CoreValve device the recommended device/annulus oversizing is 15 % of the aortic basal ring perimeter. For the Edwards Sapiens valve, the recommended device/annulus oversizing is 15–25 % of the area and 7–12 % of the mean diameter. This degree of oversizing of the THV appears to provide the best risk-benefit ratio in terms of PAR reduction and conduction disorders [57, 58]. Undersizing of the THV can lead to increased PAR and greater likelihood of valve ‘pop-out’ or migration [10, 59].

Post-implantation imaging

Post-implantation imaging can be divided into immediately post-procedure and long-term follow-up. For the immediate assessment of valve position and haemodynamic status, including the gradients and effective valve area, the modality of choice is TEE, which can be done in the hybrid procedure room. Paravalvular and transvalvular regurgitation can also be estimated in real time, allowing appropriate steps to be taken to minimise complications and optimise device positioning [16, 54].
For long-term follow-up of TAVR ECG-gated MDCT is useful in diagnosing prosthesis misplacement by careful inspection of the exact positioning of the device in relation to the aortic annulus plane [55].
Significantly low implantation may result in severe paravalvular regurgitation, residual aortic valve stenosis, mitral valve insufficiency, conduction abnormalities and, in extreme cases, device drop into the left ventricular cavity. Considerably high implantation may result in paravalvular regurgitation, coronary flow obstruction and device embolisation into the thoracic aorta [10, 60].
The exact definition of misplacement is specific to the TAVR device type. The optimal deployment location of the Medtronic CoreValve® device requires that the most inferior edge of the device, the inflow portion, should be positioned approximately 4–6 mm below the aortic annulus plane [61, 62] (Fig. 29). The optimal deployment location of the Edwards SAPIEN device is likely gained when 50 % of its height is below and 50 % of its height above the aortic annulus plane [10, 60]. (Fig. 30).

Challenges and perspectives

TAVR is a novel procedure that provides unique opportunities for multimodality research comparing different imaging strategies and different THV devices. Given the exponential rise in the number of procedures being performed with varying local expertise, there is a need to standardise imaging protocols as part of pre- and post-procedure assessment of TAVR patients. Implementation of standardised protocols is crucial not only for precise assessment of the aortic valve apparatus and vascular access with different scanners in different institutions, but also for creating opportunities for further multicentre research. The SCCT expert consensus document devoted to this topic suggests potential algorithms and techniques for imaging before TAVR. Although there is growing evidence of the importance of MDCT in the pre-procedure assessment, one of the current challenges is to find the precise role of MDCT in valve assessment and sizing. Thus, developing a rational algorithm for imaging use both before and after implant should become a priority to avoid substantial redundancy in imaging. Another potential role for imaging is the assessment of outcome prediction, based on the diagnosis of both cardiac and non-cardiac comorbidities. If successful, this should allow for optimised patient selection for the currently costly procedure. Overall, current trends strongly suggest that imaging, in particular MDCT, will play an increasingly important role in all aspects related to the TAVR procedure.

Summary

During the last decade transcatheter aortic valve replacement has become widely used in many centres across the world with good clinical outcomes. The planning and performance of the procedure are based on a multidisciplinary team approach, with imaging proving crucial for pre-procedure planning. MDCT plays an important role in assessing the aortic valve, aortic root and ascending aorta, as well as the access root for the procedure (i.e., ilio-femoral, direct aortic or subclavian) utilising the combination of multiplanar reconstruction and 3D imaging. TAVR technology and equipment are rapidly advancing, with increased utilisation of advanced MDCT imaging contributing to continuing outcome improvement and broadening of procedure applications.
Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Literatur
1.
Zurück zum Zitat Aronow WS, Kronzon I (1991) Prevalence and severity of valvular aortic stenosis determined by Doppler echocardiography and its association with echocardiographic and electrocardiographic left ventricular hypertrophy and physical signs of aortic stenosis in elderly patients. Am J Cardiol 67:776–777PubMedCrossRef Aronow WS, Kronzon I (1991) Prevalence and severity of valvular aortic stenosis determined by Doppler echocardiography and its association with echocardiographic and electrocardiographic left ventricular hypertrophy and physical signs of aortic stenosis in elderly patients. Am J Cardiol 67:776–777PubMedCrossRef
2.
Zurück zum Zitat Supino PG, Borer JS, Preibisz J, Bornstein A (2006) The epidemiology of valvular heart disease: a growing public health problem. Heart Fail Clin 2:379–393PubMedCrossRef Supino PG, Borer JS, Preibisz J, Bornstein A (2006) The epidemiology of valvular heart disease: a growing public health problem. Heart Fail Clin 2:379–393PubMedCrossRef
3.
Zurück zum Zitat Otto CM, Pearlman AS, Gardner CL (1989) Hemodynamic progression of aortic stenosis in adults assessed by Doppler echocardiography. J Am Coll Cardiol 13:545–550PubMedCrossRef Otto CM, Pearlman AS, Gardner CL (1989) Hemodynamic progression of aortic stenosis in adults assessed by Doppler echocardiography. J Am Coll Cardiol 13:545–550PubMedCrossRef
5.
Zurück zum Zitat Lund O (1990) Preoperative risk evaluation and stratification of long-term survival after valve replacement for aortic stenosis. Reasons for earlier operative intervention. Circulation 82:124–139PubMedCrossRef Lund O (1990) Preoperative risk evaluation and stratification of long-term survival after valve replacement for aortic stenosis. Reasons for earlier operative intervention. Circulation 82:124–139PubMedCrossRef
6.
Zurück zum Zitat Dewey TM, Brown D, Ryan WH, Herbert MA, Prince SL, Mack MJ (2008) Reliability of risk algorithms in predicting early and late operative outcomes in high-risk patients undergoing aortic valve replacement. J Thorac Cardiovasc Surg 135:180–187PubMedCrossRef Dewey TM, Brown D, Ryan WH, Herbert MA, Prince SL, Mack MJ (2008) Reliability of risk algorithms in predicting early and late operative outcomes in high-risk patients undergoing aortic valve replacement. J Thorac Cardiovasc Surg 135:180–187PubMedCrossRef
7.
Zurück zum Zitat Iung B, Cachier A, Baron G et al (2005) Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J 26:2714–2720PubMedCrossRef Iung B, Cachier A, Baron G et al (2005) Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J 26:2714–2720PubMedCrossRef
8.
Zurück zum Zitat Shahian DM, He X, Jacobs JP et al (2012) The Society of Thoracic Surgeons Isolated Aortic Valve Replacement (AVR) Composite Score: a report of the STS Quality Measurement Task Force. Ann Thorac Surg 94:2166–2171PubMedCrossRef Shahian DM, He X, Jacobs JP et al (2012) The Society of Thoracic Surgeons Isolated Aortic Valve Replacement (AVR) Composite Score: a report of the STS Quality Measurement Task Force. Ann Thorac Surg 94:2166–2171PubMedCrossRef
9.
Zurück zum Zitat Cribier A, Eltchaninoff H, Bash A et al (2002) Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106:3006–3008PubMedCrossRef Cribier A, Eltchaninoff H, Bash A et al (2002) Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106:3006–3008PubMedCrossRef
10.
Zurück zum Zitat Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 1:74–81PubMedCrossRef Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 1:74–81PubMedCrossRef
11.
Zurück zum Zitat Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6:366–380PubMedCrossRef Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6:366–380PubMedCrossRef
12.
Zurück zum Zitat Leon MB, Smith CR, Mack M et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607PubMedCrossRef Leon MB, Smith CR, Mack M et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607PubMedCrossRef
13.
Zurück zum Zitat Smith CR, Leon MB, Mack MJ et al (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364:2187–2198PubMedCrossRef Smith CR, Leon MB, Mack MJ et al (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364:2187–2198PubMedCrossRef
14.
Zurück zum Zitat Stortecky S, Buellesfeld L, Wenaweser P, Windecker S (2012) Transcatheter aortic valve implantation: the procedure. Heart 98(Suppl 4):iv44–iv51PubMed Stortecky S, Buellesfeld L, Wenaweser P, Windecker S (2012) Transcatheter aortic valve implantation: the procedure. Heart 98(Suppl 4):iv44–iv51PubMed
15.
Zurück zum Zitat Bapat VN, Attia RQ, Thomas M (2012) Distribution of calcium in the ascending aorta in patients undergoing transcatheter aortic valve implantation and its relevance to the transaortic approach. JACC Cardiovasc Interv 5:470–476PubMedCrossRef Bapat VN, Attia RQ, Thomas M (2012) Distribution of calcium in the ascending aorta in patients undergoing transcatheter aortic valve implantation and its relevance to the transaortic approach. JACC Cardiovasc Interv 5:470–476PubMedCrossRef
16.
Zurück zum Zitat Bruschi G, Fratto P, De Marco F et al (2010) The trans-subclavian retrograde approach for transcatheter aortic valve replacement: single-center experience. J Thorac Cardiovasc Surg 140:911–915, 915 e911-912PubMedCrossRef Bruschi G, Fratto P, De Marco F et al (2010) The trans-subclavian retrograde approach for transcatheter aortic valve replacement: single-center experience. J Thorac Cardiovasc Surg 140:911–915, 915 e911-912PubMedCrossRef
17.
Zurück zum Zitat Schafer U, Ho Y, Frerker C et al (2012) Direct percutaneous access technique for transaxillary transcatheter aortic valve implantation: "the Hamburg Sankt Georg approach". JACC Cardiovasc Interv 5:477–486PubMedCrossRef Schafer U, Ho Y, Frerker C et al (2012) Direct percutaneous access technique for transaxillary transcatheter aortic valve implantation: "the Hamburg Sankt Georg approach". JACC Cardiovasc Interv 5:477–486PubMedCrossRef
18.
Zurück zum Zitat Philipsen TE, Rodrigus IE, Claeys MJ, Bosmans JM (2012) Alternative access in transcatheter aortic valve implantation: brachiocephalic artery access. Innovations (Phila) 7:372–375CrossRef Philipsen TE, Rodrigus IE, Claeys MJ, Bosmans JM (2012) Alternative access in transcatheter aortic valve implantation: brachiocephalic artery access. Innovations (Phila) 7:372–375CrossRef
19.
Zurück zum Zitat Billings FT, Kodali SK, Shanewise JS (2009) Transcatheter aortic valve implantation: anesthetic considerations. Anesth Analg 108:1453–1462PubMedCrossRef Billings FT, Kodali SK, Shanewise JS (2009) Transcatheter aortic valve implantation: anesthetic considerations. Anesth Analg 108:1453–1462PubMedCrossRef
20.
Zurück zum Zitat Bloomfield GS, Gillam LD, Hahn RT et al (2012) A practical guide to multimodality imaging of transcatheter aortic valve replacement. J Am Coll Cardiol Img 5:441–455CrossRef Bloomfield GS, Gillam LD, Hahn RT et al (2012) A practical guide to multimodality imaging of transcatheter aortic valve replacement. J Am Coll Cardiol Img 5:441–455CrossRef
21.
Zurück zum Zitat Leipsic J, Wood D, Manders D et al (2009) The evolving role of MDCT in transcatheter aortic valve replacement: a radiologists' perspective. AJR Am J Roentgenol 193:W214–W219PubMedCrossRef Leipsic J, Wood D, Manders D et al (2009) The evolving role of MDCT in transcatheter aortic valve replacement: a radiologists' perspective. AJR Am J Roentgenol 193:W214–W219PubMedCrossRef
22.
Zurück zum Zitat Vassiliades TA Jr, Block PC, Cohn LH et al (2005) The clinical development of percutaneous heart valve technology: a position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA). J Am Coll Cardiol 45:1554–1560PubMedCrossRef Vassiliades TA Jr, Block PC, Cohn LH et al (2005) The clinical development of percutaneous heart valve technology: a position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA). J Am Coll Cardiol 45:1554–1560PubMedCrossRef
23.
Zurück zum Zitat Nashef SA, Roques F, Hammill BG et al (2002) Validation of European System for Cardiac Operative Risk Evaluation (EuroSCORE) in North American cardiac surgery. Eur J Cardiothorac Surg 22:101–105PubMedCrossRef Nashef SA, Roques F, Hammill BG et al (2002) Validation of European System for Cardiac Operative Risk Evaluation (EuroSCORE) in North American cardiac surgery. Eur J Cardiothorac Surg 22:101–105PubMedCrossRef
24.
Zurück zum Zitat Husser O, Rauch S, Endemann DH et al (2012) Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation. Catheter Cardiovasc Interv 80:956–963PubMedCrossRef Husser O, Rauch S, Endemann DH et al (2012) Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation. Catheter Cardiovasc Interv 80:956–963PubMedCrossRef
25.
Zurück zum Zitat Jilaihawi H, Doctor N, Kashif M et al (2013) Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography. J Am Coll Cardiol 61:908–916PubMedCrossRef Jilaihawi H, Doctor N, Kashif M et al (2013) Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography. J Am Coll Cardiol 61:908–916PubMedCrossRef
26.
Zurück zum Zitat Leipsic J, Gurvitch R, Labounty TM et al (2011) Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 4:416–429PubMedCrossRef Leipsic J, Gurvitch R, Labounty TM et al (2011) Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 4:416–429PubMedCrossRef
27.
Zurück zum Zitat Wuest W, Anders K, Schuhbaeck A et al (2012) Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol 22:51–58PubMedCrossRef Wuest W, Anders K, Schuhbaeck A et al (2012) Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol 22:51–58PubMedCrossRef
28.
Zurück zum Zitat Willson AB, Webb JG, Labounty TM et al (2012) 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol 59:1287–1294PubMedCrossRef Willson AB, Webb JG, Labounty TM et al (2012) 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol 59:1287–1294PubMedCrossRef
29.
Zurück zum Zitat Blanke P, Reinohl J, Schlensak C et al (2012) Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv 5:540–548PubMedCrossRef Blanke P, Reinohl J, Schlensak C et al (2012) Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv 5:540–548PubMedCrossRef
30.
Zurück zum Zitat Halliburton SS, Abbara S, Chen MY et al (2011) SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT. J Cardiovasc Comput Tomogr 5:198–224PubMedPubMedCentralCrossRef Halliburton SS, Abbara S, Chen MY et al (2011) SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT. J Cardiovasc Comput Tomogr 5:198–224PubMedPubMedCentralCrossRef
31.
Zurück zum Zitat Schoenhagen P, Kapadia SR, Halliburton SS, Svensson LG, Tuzcu EM (2011) Computed tomography evaluation for transcatheter aortic valve implantation (TAVI): imaging of the aortic root and iliac arteries. J Cardiovasc Comput Tomogr 5:293–300PubMedCrossRef Schoenhagen P, Kapadia SR, Halliburton SS, Svensson LG, Tuzcu EM (2011) Computed tomography evaluation for transcatheter aortic valve implantation (TAVI): imaging of the aortic root and iliac arteries. J Cardiovasc Comput Tomogr 5:293–300PubMedCrossRef
32.
Zurück zum Zitat Yuan R, Shuman WP, Earls JP et al (2012) Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography–a prospective randomized trial. Radiology 262:290–297PubMedCrossRef Yuan R, Shuman WP, Earls JP et al (2012) Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography–a prospective randomized trial. Radiology 262:290–297PubMedCrossRef
33.
Zurück zum Zitat Joshi SB, Mendoza DD, Steinberg DH et al (2009) Ultra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic angiography. JACC Cardiovasc Imaging 2:1404–1411PubMedCrossRef Joshi SB, Mendoza DD, Steinberg DH et al (2009) Ultra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic angiography. JACC Cardiovasc Imaging 2:1404–1411PubMedCrossRef
34.
Zurück zum Zitat Nietlispach F, Leipsic J, Al-Bugami S, Masson JB, Carere RG, Webb JG (2009) CT of the ilio-femoral arteries using direct aortic contrast injection: proof of feasibility in patients screened towards percutaneous aortic valve replacement. Swiss Med Wkly 139:458PubMed Nietlispach F, Leipsic J, Al-Bugami S, Masson JB, Carere RG, Webb JG (2009) CT of the ilio-femoral arteries using direct aortic contrast injection: proof of feasibility in patients screened towards percutaneous aortic valve replacement. Swiss Med Wkly 139:458PubMed
35.
Zurück zum Zitat Vahanian A, Himbert D, Brochet E, Depoix JP, Iung B, Nataf P (2012) Transcatheter aortic valve implantation: our vision of the future. Arch Cardiovasc Dis 105:181–186PubMedCrossRef Vahanian A, Himbert D, Brochet E, Depoix JP, Iung B, Nataf P (2012) Transcatheter aortic valve implantation: our vision of the future. Arch Cardiovasc Dis 105:181–186PubMedCrossRef
36.
Zurück zum Zitat Hayashida K, Lefevre T, Chevalier B et al (2011) Transfemoral aortic valve implantation new criteria to predict vascular complications. JACC Cardiovasc Interv 4:851–858PubMedCrossRef Hayashida K, Lefevre T, Chevalier B et al (2011) Transfemoral aortic valve implantation new criteria to predict vascular complications. JACC Cardiovasc Interv 4:851–858PubMedCrossRef
37.
Zurück zum Zitat Hamdan A, Guetta V, Konen E et al (2012) Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 59:119–127PubMedCrossRef Hamdan A, Guetta V, Konen E et al (2012) Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 59:119–127PubMedCrossRef
38.
Zurück zum Zitat Delgado V, Kapadia S, Schalij MJ, Schuijf JD, Tuzcu EM, Bax JJ (2012) Transcatheter aortic valve implantation: implications of multimodality imaging in patient selection, procedural guidance, and outcomes. Heart 98:743–754PubMedCrossRef Delgado V, Kapadia S, Schalij MJ, Schuijf JD, Tuzcu EM, Bax JJ (2012) Transcatheter aortic valve implantation: implications of multimodality imaging in patient selection, procedural guidance, and outcomes. Heart 98:743–754PubMedCrossRef
39.
Zurück zum Zitat John D, Buellesfeld L, Yuecel S et al (2010) Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv 3:233–243PubMedCrossRef John D, Buellesfeld L, Yuecel S et al (2010) Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv 3:233–243PubMedCrossRef
40.
Zurück zum Zitat Genereux P, Head SJ, Van Mieghem NM et al (2012) Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol 59:2317–2326PubMedCrossRef Genereux P, Head SJ, Van Mieghem NM et al (2012) Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol 59:2317–2326PubMedCrossRef
41.
Zurück zum Zitat Treede H, Tubler T, Reichenspurner H et al (2010) Six-month results of a repositionable and retrievable pericardial valve for transcatheter aortic valve replacement: the Direct Flow Medical aortic valve. J Thorac Cardiovasc Surg 140:897–903PubMedCrossRef Treede H, Tubler T, Reichenspurner H et al (2010) Six-month results of a repositionable and retrievable pericardial valve for transcatheter aortic valve replacement: the Direct Flow Medical aortic valve. J Thorac Cardiovasc Surg 140:897–903PubMedCrossRef
42.
Zurück zum Zitat Webb JG, Harnek J, Munt BI et al (2006) Percutaneous transvenous mitral annuloplasty: initial human experience with device implantation in the coronary sinus. Circulation 113:851–855PubMedCrossRef Webb JG, Harnek J, Munt BI et al (2006) Percutaneous transvenous mitral annuloplasty: initial human experience with device implantation in the coronary sinus. Circulation 113:851–855PubMedCrossRef
43.
Zurück zum Zitat Van Mieghem NM, Schultz CJ, van der Boon RM et al (2012) Incidence, timing, and predictors of valve dislodgment during TAVI with the Medtronic Corevalve System. Catheter Cardiovasc Interv 79:726–732PubMedCrossRef Van Mieghem NM, Schultz CJ, van der Boon RM et al (2012) Incidence, timing, and predictors of valve dislodgment during TAVI with the Medtronic Corevalve System. Catheter Cardiovasc Interv 79:726–732PubMedCrossRef
44.
Zurück zum Zitat Koos R, Mahnken AH, Dohmen G et al (2011) Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol 150:142–145PubMedCrossRef Koos R, Mahnken AH, Dohmen G et al (2011) Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol 150:142–145PubMedCrossRef
45.
Zurück zum Zitat Nombela-Franco L, Rodes-Cabau J, DeLarochelliere R et al (2012) Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve. JACC Cardiovasc Interv 5:499–512PubMedCrossRef Nombela-Franco L, Rodes-Cabau J, DeLarochelliere R et al (2012) Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve. JACC Cardiovasc Interv 5:499–512PubMedCrossRef
46.
Zurück zum Zitat Tops LF, Wood DA, Delgado V et al (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1:321–330PubMedCrossRef Tops LF, Wood DA, Delgado V et al (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1:321–330PubMedCrossRef
47.
Zurück zum Zitat Anderson R, Becker A, Piazza N (2010) The Anatomy of the Aortic Valvar Complex. In: Serruys P, Piazza N, Cribier A, Webb J, Laborde J-C, de Jaegere P (eds) Transcatheter Aortic Valve Implantation: Tips and Tricks to Avoid Failure. Informa Healthcare, New York, pp 1–17 Anderson R, Becker A, Piazza N (2010) The Anatomy of the Aortic Valvar Complex. In: Serruys P, Piazza N, Cribier A, Webb J, Laborde J-C, de Jaegere P (eds) Transcatheter Aortic Valve Implantation: Tips and Tricks to Avoid Failure. Informa Healthcare, New York, pp 1–17
48.
Zurück zum Zitat Toggweiler S, Gurvitch R, Leipsic J et al (2012) Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. J Am Coll Cardiol 59:113–118PubMedCrossRef Toggweiler S, Gurvitch R, Leipsic J et al (2012) Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. J Am Coll Cardiol 59:113–118PubMedCrossRef
49.
Zurück zum Zitat Kurra V, Schoenhagen P, Roselli EE et al (2009) Prevalence of significant peripheral artery disease in patients evaluated for percutaneous aortic valve insertion: Preprocedural assessment with multidetector computed tomography. J Thorac Cardiovasc Surg 137:1258–1264PubMedCrossRef Kurra V, Schoenhagen P, Roselli EE et al (2009) Prevalence of significant peripheral artery disease in patients evaluated for percutaneous aortic valve insertion: Preprocedural assessment with multidetector computed tomography. J Thorac Cardiovasc Surg 137:1258–1264PubMedCrossRef
50.
Zurück zum Zitat Altiok E, Koos R, Schroder J et al (2011) Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation. Heart 97:1578–1584PubMedCrossRef Altiok E, Koos R, Schroder J et al (2011) Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation. Heart 97:1578–1584PubMedCrossRef
51.
Zurück zum Zitat Ng AC, Delgado V, van der Kley F et al (2010) Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging 3:94–102PubMedCrossRef Ng AC, Delgado V, van der Kley F et al (2010) Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging 3:94–102PubMedCrossRef
52.
Zurück zum Zitat Gurvitch R, Webb JG, Yuan R et al (2011) Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. JACC Cardiovasc Interv 4:1235–1245PubMedCrossRef Gurvitch R, Webb JG, Yuan R et al (2011) Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. JACC Cardiovasc Interv 4:1235–1245PubMedCrossRef
53.
Zurück zum Zitat Zhang R, Song Y, Zhou Y, Sun L (2013) Comparison of aortic annulus diameter measurement between multi-detector computed tomography and echocardiography: a meta-analysis. PLoS One 8:e58729PubMedPubMedCentralCrossRef Zhang R, Song Y, Zhou Y, Sun L (2013) Comparison of aortic annulus diameter measurement between multi-detector computed tomography and echocardiography: a meta-analysis. PLoS One 8:e58729PubMedPubMedCentralCrossRef
54.
Zurück zum Zitat Willson AB, Webb JG, Gurvitch R et al (2012) Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography. JACC Cardiovasc Interv 5:525–532PubMedCrossRef Willson AB, Webb JG, Gurvitch R et al (2012) Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography. JACC Cardiovasc Interv 5:525–532PubMedCrossRef
55.
Zurück zum Zitat Jabbour A, Ismail TF, Moat N et al (2011) Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. J Am Coll Cardiol 58:2165–2173PubMedCrossRef Jabbour A, Ismail TF, Moat N et al (2011) Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. J Am Coll Cardiol 58:2165–2173PubMedCrossRef
56.
Zurück zum Zitat Jilaihawi H, Kashif M, Fontana G et al (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59:1275–1286PubMedCrossRef Jilaihawi H, Kashif M, Fontana G et al (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59:1275–1286PubMedCrossRef
57.
Zurück zum Zitat Hansson NC, Thuesen L, Hjortdal VE, et al (2013) 3-Dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on post-procedural paravalvular aortic regurgitation. Catheter Cardiovasc Interv doi:10.1002/ccd.25005 Hansson NC, Thuesen L, Hjortdal VE, et al (2013) 3-Dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on post-procedural paravalvular aortic regurgitation. Catheter Cardiovasc Interv doi:10.​1002/​ccd.​25005
58.
Zurück zum Zitat Leber AW, Eichinger W, Rieber J, et al (2013) MSCT guided sizing of the Edwards Sapien XT TAVI device: Impact of different degrees of oversizing on clinical outcome. Int J Cardiol 168(3):2658–64 Leber AW, Eichinger W, Rieber J, et al (2013) MSCT guided sizing of the Edwards Sapien XT TAVI device: Impact of different degrees of oversizing on clinical outcome. Int J Cardiol 168(3):2658–64
59.
Zurück zum Zitat Athappan G, Patvardhan E, Tuzcu EM et al (2013) Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol 61:1585–1595PubMedCrossRef Athappan G, Patvardhan E, Tuzcu EM et al (2013) Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol 61:1585–1595PubMedCrossRef
60.
Zurück zum Zitat Dvir D, Lavi I, Eltchaninoff H et al (2012) Multicenter evaluation of Edwards SAPIEN positioning during transcatheter aortic valve implantation with correlates for device movement during final deployment. JACC Cardiovasc Interv 5:563–570PubMedCrossRef Dvir D, Lavi I, Eltchaninoff H et al (2012) Multicenter evaluation of Edwards SAPIEN positioning during transcatheter aortic valve implantation with correlates for device movement during final deployment. JACC Cardiovasc Interv 5:563–570PubMedCrossRef
61.
Zurück zum Zitat Laborde JC, Brecker SJ, Roy D, Jahangiri M (2012) Complications at the time of transcatheter aortic valve implantation. Methodist Debakey Cardiovasc J 8:38–41PubMedPubMedCentralCrossRef Laborde JC, Brecker SJ, Roy D, Jahangiri M (2012) Complications at the time of transcatheter aortic valve implantation. Methodist Debakey Cardiovasc J 8:38–41PubMedPubMedCentralCrossRef
62.
Zurück zum Zitat Lange R, Bleiziffer S, Piazza N et al (2011) Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg 40:1105–1113PubMed Lange R, Bleiziffer S, Piazza N et al (2011) Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg 40:1105–1113PubMed
63.
Zurück zum Zitat Webb JG, Wood DA (2012) Current status of transcatheter aortic valve replacement. J Am Coll Cardiol 60:483–492PubMedCrossRef Webb JG, Wood DA (2012) Current status of transcatheter aortic valve replacement. J Am Coll Cardiol 60:483–492PubMedCrossRef
Metadaten
Titel
Imaging in Transcatheter Aortic Valve Replacement (TAVR): role of the radiologist
verfasst von
Diana E. Litmanovich
Eduard Ghersin
David A. Burke
Jeffrey Popma
Maryam Shahrzad
Alexander A. Bankier
Publikationsdatum
01.02.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Insights into Imaging / Ausgabe 1/2014
Elektronische ISSN: 1869-4101
DOI
https://doi.org/10.1007/s13244-013-0301-5

Weitere Artikel der Ausgabe 1/2014

Insights into Imaging 1/2014 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.