01.12.2014 | Original Paper

Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 8/2014

Einloggen, um Zugang zu erhalten

Abstract

To investigate the impact of a vendor-specific motion-correction algorithm on morphological assessment of coronary arteries using coronary CT angiography (cCTA) and to evaluate the influence of heart rate (HR) on the motion-correction effect of this algorithm. Eighty-four patients (mean age 56.3 ± 11.4 years; 53 males) were divided into two groups with a HR of ≥65 and <65 bpm during cCTA, respectively. Images were assigned quality scores (graded 1–4) on coronary segments. Interpretability was defined as a grade >1. Catheter angiography was used to determine the diagnostic accuracy of cCTA for detecting significant stenosis (≥50 %). We compared the image quality, interpretability and diagnostic accuracy between the standard and motion-correction reconstructions in both groups. The motion-correction reconstructions showed significantly (p < 0.05) higher image quality in the proximal and middle right coronary artery (RCA) in the low HR group (57.2 ± 5.0 bpm; n = 51) and proximal-to-distal RCA, posterior descending artery, and proximal and distal left circumflex artery in the high HR group (71.1 ± 4.6 bpm; n = 33). The per-segment interpretability was significantly higher using motion-correction algorithm in the middle RCA in the low HR group and in the proximal and middle RCA in high HR group. Overall, the image quality and interpretability were improved using motion-correction reconstructions in both groups (p < 0.05). Motion-correction reconstruction demonstrated higher (p < 0.05) diagnostic accuracy in 25 patients from both groups. Use of the motion-correction algorithm improves the overall image quality and interpretability of cCTA in both groups. However, it may be more beneficial to the patients with a higher HR.
Literatur
1.
Zurück zum Zitat Schoepf UJ, Zwerner PL, Savino G et al (2007) Coronary CT angiography. Radiology 244(1):48–63PubMedCrossRef Schoepf UJ, Zwerner PL, Savino G et al (2007) Coronary CT angiography. Radiology 244(1):48–63PubMedCrossRef
2.
Zurück zum Zitat Achenbach S (2006) Computed tomography coronary angiography. J Am Coll Cardiol 48(10):1919–1928PubMedCrossRef Achenbach S (2006) Computed tomography coronary angiography. J Am Coll Cardiol 48(10):1919–1928PubMedCrossRef
3.
Zurück zum Zitat Leschka S, Wildermuth S, Boehm T et al (2006) Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 241(2):378–385PubMedCrossRef Leschka S, Wildermuth S, Boehm T et al (2006) Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 241(2):378–385PubMedCrossRef
4.
Zurück zum Zitat Bastarrika G, Lee YS, Huda W et al (2009) CT of coronary artery disease. Radiology 253(2):317–338PubMedCrossRef Bastarrika G, Lee YS, Huda W et al (2009) CT of coronary artery disease. Radiology 253(2):317–338PubMedCrossRef
5.
Zurück zum Zitat Miller JM, Rochitte CE, Dewey M et al (2008) Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 359(22):2324–2336PubMedCrossRef Miller JM, Rochitte CE, Dewey M et al (2008) Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 359(22):2324–2336PubMedCrossRef
6.
Zurück zum Zitat Dewey M, Teige F, Laule M et al (2007) Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches. Eur Radiol 17(11):2829–2837PubMedCrossRef Dewey M, Teige F, Laule M et al (2007) Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches. Eur Radiol 17(11):2829–2837PubMedCrossRef
7.
Zurück zum Zitat Seifarth H, Wienbeck S, Pusken M et al (2007) Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT. AJR Am J Roentgenol 189(6):1317–1323PubMedCrossRef Seifarth H, Wienbeck S, Pusken M et al (2007) Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT. AJR Am J Roentgenol 189(6):1317–1323PubMedCrossRef
8.
Zurück zum Zitat Chung CS, Karamanoglu M, Kovacs SJ (2004) Duration of diastole and its phases as a function of heart rate during supine bicycle exercise. Am J Physiol Heart Circ Physiol 287(5):H2003–H2008PubMedCrossRef Chung CS, Karamanoglu M, Kovacs SJ (2004) Duration of diastole and its phases as a function of heart rate during supine bicycle exercise. Am J Physiol Heart Circ Physiol 287(5):H2003–H2008PubMedCrossRef
9.
Zurück zum Zitat Abbara S, Arbab-Zadeh A, Callister TQ et al (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 3(3):190–204PubMedCrossRef Abbara S, Arbab-Zadeh A, Callister TQ et al (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 3(3):190–204PubMedCrossRef
10.
Zurück zum Zitat Scharf M, Bink R, May MS et al (2011) High-pitch thoracic CT with simultaneous assessment of coronary arteries: effect of heart rate and heart rate variability on image quality and diagnostic accuracy. JACC Cardiovasc Imaging 4(6):602–609PubMedCrossRef Scharf M, Bink R, May MS et al (2011) High-pitch thoracic CT with simultaneous assessment of coronary arteries: effect of heart rate and heart rate variability on image quality and diagnostic accuracy. JACC Cardiovasc Imaging 4(6):602–609PubMedCrossRef
11.
Zurück zum Zitat Achenbach S, Ropers U, Kuettner A et al (2008) Randomized comparison of 64-slice single- and dual-source computed tomography coronary angiography for the detection of coronary artery disease. JACC Cardiovasc Imaging 1(2):177–186PubMedCrossRef Achenbach S, Ropers U, Kuettner A et al (2008) Randomized comparison of 64-slice single- and dual-source computed tomography coronary angiography for the detection of coronary artery disease. JACC Cardiovasc Imaging 1(2):177–186PubMedCrossRef
12.
Zurück zum Zitat Schnapauff D, Teige F, Hamm B et al (2009) Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography. Br J Radiol 82(984):969–975PubMedCentralPubMedCrossRef Schnapauff D, Teige F, Hamm B et al (2009) Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography. Br J Radiol 82(984):969–975PubMedCentralPubMedCrossRef
13.
Zurück zum Zitat Matt D, Scheffel H, Leschka S et al (2007) Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol 189(3):567–573PubMedCrossRef Matt D, Scheffel H, Leschka S et al (2007) Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol 189(3):567–573PubMedCrossRef
14.
Zurück zum Zitat Dewey M, Laule M, Krug L et al (2004) Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses. Invest Radiol 39(4):223–229PubMedCrossRef Dewey M, Laule M, Krug L et al (2004) Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses. Invest Radiol 39(4):223–229PubMedCrossRef
15.
Zurück zum Zitat Leipsic J, Labounty TM, Hague CJ et al (2012) Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications. J Cardiovasc Comput Tomogr 6(3):164–171PubMedCrossRef Leipsic J, Labounty TM, Hague CJ et al (2012) Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications. J Cardiovasc Comput Tomogr 6(3):164–171PubMedCrossRef
16.
Zurück zum Zitat Delhaye D, Remy-Jardin M, Rozel C et al (2007) Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients. Eur Radiol 17(3):591–602PubMedCrossRef Delhaye D, Remy-Jardin M, Rozel C et al (2007) Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients. Eur Radiol 17(3):591–602PubMedCrossRef
17.
Zurück zum Zitat Einstein AJ, Elliston CD, Arai AE et al (2010) Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner. Radiology 254(3):698–706PubMedCentralPubMedCrossRef Einstein AJ, Elliston CD, Arai AE et al (2010) Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner. Radiology 254(3):698–706PubMedCentralPubMedCrossRef
18.
Zurück zum Zitat Ding Z, Friedman MH (2000) Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms. Int J Card Imaging 16(5):331–346PubMedCrossRef Ding Z, Friedman MH (2000) Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms. Int J Card Imaging 16(5):331–346PubMedCrossRef
19.
Zurück zum Zitat Husmann L, Leschka S, Desbiolles L et al (2007) Coronary artery motion and cardiac phases: dependency on heart rate—implications for CT image reconstruction. Radiology 245(2):567–576PubMedCrossRef Husmann L, Leschka S, Desbiolles L et al (2007) Coronary artery motion and cardiac phases: dependency on heart rate—implications for CT image reconstruction. Radiology 245(2):567–576PubMedCrossRef
20.
Zurück zum Zitat Min JK, Arsanjani R, Kurabayashi S et al (2013) Rationale and design of the ViCTORY (Validation of an Intracycle CT Motion CORrection Algorithm for Diagnostic AccuracY) trial. J Cardiovasc Comput Tomogr 7(3):200–206PubMedCrossRef Min JK, Arsanjani R, Kurabayashi S et al (2013) Rationale and design of the ViCTORY (Validation of an Intracycle CT Motion CORrection Algorithm for Diagnostic AccuracY) trial. J Cardiovasc Comput Tomogr 7(3):200–206PubMedCrossRef
21.
Zurück zum Zitat Taylor AJ, Cerqueira M, Hodgson JM et al (2010) ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance. J Cardiovasc Comput Tomogr 4(6):407.e1– 407.e33 Taylor AJ, Cerqueira M, Hodgson JM et al (2010) ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance. J Cardiovasc Comput Tomogr 4(6):407.e1– 407.e33
Metadaten
Titel
Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction
Publikationsdatum
01.12.2014
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 8/2014
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-014-0499-4

Weitere Artikel der Ausgabe 8/2014

The International Journal of Cardiovascular Imaging 8/2014 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.