Skip to main content
Erschienen in: European Radiology 3/2007

01.03.2007 | Cardiac

Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients

verfasst von: Damien Delhaye, Martine Remy-Jardin, Céline Rozel, Catherine Dusson, Alain Wurtz, Valérie Delannoy-Deken, Alain Duhamel, Jacques Remy

Erschienen in: European Radiology | Ausgabe 3/2007

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate the clinical feasibility of coronary artery imaging during routine preoperative 64-slice MDCT scans of the chest. Ninety-nine consecutive patients in sinus rhythm underwent a biphasic multidetector-row spiral CT examination of the chest without the administration of beta-blockers, including an ECG-gated acquisition over the cardiac cavities, followed by a non-gated examination of the upper third of the thorax. Data were reconstructed to evaluate coronary arteries and to obtain presurgical staging of the underlying disease. The percentage of assessable segments ranged from 65.4% (972/1,485) when considering all coronary artery segments to 88% (613/693) for the proximal and mid segments, reaching 98% (387/396) for proximal coronary artery segments. The 387 interpretable proximal segments included 97 (97%) LM, 99 (100%) LAD, 96 (97%) LCX and 95 (96%) RCA with a mean attenuation of 280.70±52.93 HU. The mean percentage of assessable segments was significantly higher in patients with a heart rate ≤80 bpm (n=48) than in patients with a heart rate greater than 80 bpm (n=35) (80±11% vs. 72±13%; P=0.0008). Diagnostic image quality was achieved in all patients for preoperative staging of the underlying disorder. The mean estimated effective dose was 12.06±3.25 mSv for ECG-gated scans and 13.88±3.49 mSv for complete chest examinations. Proximal and mid-coronary artery segments can be adequately evaluated during presurgical CT examinations of the chest obtained with 64-slice MDCT without the administration of β-blockers.
Literatur
1.
Zurück zum Zitat Freeman WK, Gibbons RJ, Shub C (1989) Preoperative assessment of the cardiac patient undergoing non cardiac procedures. Mayo Clin Proc 64:1105–1117PubMed Freeman WK, Gibbons RJ, Shub C (1989) Preoperative assessment of the cardiac patient undergoing non cardiac procedures. Mayo Clin Proc 64:1105–1117PubMed
2.
Zurück zum Zitat Von Knorring JV (1981) Postoperative myocardial infarction: a prospective study in a risk group of surgical patients. Surgery 90:55–60 Von Knorring JV (1981) Postoperative myocardial infarction: a prospective study in a risk group of surgical patients. Surgery 90:55–60
3.
Zurück zum Zitat Steen PA, Tinker JH, Tarhan S (1978) Myocardial reinfarction after anesthesia and surgery. JAMA 239:2566–2570PubMedCrossRef Steen PA, Tinker JH, Tarhan S (1978) Myocardial reinfarction after anesthesia and surgery. JAMA 239:2566–2570PubMedCrossRef
4.
Zurück zum Zitat Tarhan S, Moffitt EA, Taylor WF, Guiliani ER (1972) Myocardial infarction after general anesthesia. JAMA 220:1451–1454PubMedCrossRef Tarhan S, Moffitt EA, Taylor WF, Guiliani ER (1972) Myocardial infarction after general anesthesia. JAMA 220:1451–1454PubMedCrossRef
5.
Zurück zum Zitat Burke JR, Duarte IC, Thourani VH, Miller JI (2003) Preoperative risk assessment for marginal patients requiring pulmonary resection. Ann Thorac Surg 76:1767–1773PubMedCrossRef Burke JR, Duarte IC, Thourani VH, Miller JI (2003) Preoperative risk assessment for marginal patients requiring pulmonary resection. Ann Thorac Surg 76:1767–1773PubMedCrossRef
6.
Zurück zum Zitat Achenbach S, Giesler T, Ropers D et al (2001) Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography. Circulation 103:2535–2538PubMed Achenbach S, Giesler T, Ropers D et al (2001) Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography. Circulation 103:2535–2538PubMed
7.
Zurück zum Zitat Knez A, Becker CR, Leber A et al (2001) Usefulness of multislice computed tomography angiography for determination of coronary artery stenoses. Am J Cardiol 88:1191–1194PubMedCrossRef Knez A, Becker CR, Leber A et al (2001) Usefulness of multislice computed tomography angiography for determination of coronary artery stenoses. Am J Cardiol 88:1191–1194PubMedCrossRef
8.
Zurück zum Zitat Nieman K, Rensing BJ, van Geuns RJ et al (2002) Usefulness of multislice computed tomography for detecting obstructive coronary artery disease. Am J Cardiol 89:913–918PubMedCrossRef Nieman K, Rensing BJ, van Geuns RJ et al (2002) Usefulness of multislice computed tomography for detecting obstructive coronary artery disease. Am J Cardiol 89:913–918PubMedCrossRef
9.
Zurück zum Zitat Nieman K, Rensing BJ, van Geums RJM et al (2002) Non-invasive coronary angiography with multislice spiral CT: the impact of the heart rate. Heart 88:470–474PubMedCrossRef Nieman K, Rensing BJ, van Geums RJM et al (2002) Non-invasive coronary angiography with multislice spiral CT: the impact of the heart rate. Heart 88:470–474PubMedCrossRef
10.
Zurück zum Zitat Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, Reyter PJ (2002) Reliable non-invasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054PubMedCrossRef Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, Reyter PJ (2002) Reliable non-invasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054PubMedCrossRef
11.
Zurück zum Zitat Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multidetector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666PubMedCrossRef Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multidetector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666PubMedCrossRef
12.
Zurück zum Zitat Mollet NR, Cademartiri F, Krestin G, McFadden EP, Arampatzis CA, Serruys PW, de Feyter PJ (2005) Improved diagnostic accuracy with 16-row multislice computed tomography coronary angiography. J Am Coll Cardiol 45:128–132PubMedCrossRef Mollet NR, Cademartiri F, Krestin G, McFadden EP, Arampatzis CA, Serruys PW, de Feyter PJ (2005) Improved diagnostic accuracy with 16-row multislice computed tomography coronary angiography. J Am Coll Cardiol 45:128–132PubMedCrossRef
13.
Zurück zum Zitat Heuschmid M, Kuettner A, Schroeder S, Trabold T, Feyer A, Seemann M, Kuzo R, Claussen CD, Kopp AF (2005) ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detectiong stenoses. AJR 184:1413–1419PubMed Heuschmid M, Kuettner A, Schroeder S, Trabold T, Feyer A, Seemann M, Kuzo R, Claussen CD, Kopp AF (2005) ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detectiong stenoses. AJR 184:1413–1419PubMed
14.
Zurück zum Zitat Hoffmann MHK, Shi H, Manzke R, Schmid F, De Vries L, Grass M, Brambs HJ, Aschoff AJ (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97PubMed Hoffmann MHK, Shi H, Manzke R, Schmid F, De Vries L, Grass M, Brambs HJ, Aschoff AJ (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97PubMed
15.
Zurück zum Zitat Leber AW, Knez A, von Ziegler F, Becker A, Nikolaou K, Paul S, Wintersperger B, Reiser M, Becker C, Steinbeck G, Boekstegers P (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography. A comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef Leber AW, Knez A, von Ziegler F, Becker A, Nikolaou K, Paul S, Wintersperger B, Reiser M, Becker C, Steinbeck G, Boekstegers P (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography. A comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef
16.
Zurück zum Zitat Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of non-invasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46 (in press) Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of non-invasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46 (in press)
17.
Zurück zum Zitat Leschka S, Alkadhi H, Plass A, Desbiolles L, Grünelfelder J, Marincek B, Wildermuth S (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487PubMedCrossRef Leschka S, Alkadhi H, Plass A, Desbiolles L, Grünelfelder J, Marincek B, Wildermuth S (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487PubMedCrossRef
18.
Zurück zum Zitat Salem R, Remy-Jardin M, Delhaye D, Khalil C, Teisseire A, Delannoy-Deken V, Duhamel A, Remy J (2005) Integrated cardiothoracic imaging with ECG-gated 64-slice multidetector-row CT: preliminary experience in 133 patients. Eur Radiol (accepted for publication) Salem R, Remy-Jardin M, Delhaye D, Khalil C, Teisseire A, Delannoy-Deken V, Duhamel A, Remy J (2005) Integrated cardiothoracic imaging with ECG-gated 64-slice multidetector-row CT: preliminary experience in 133 patients. Eur Radiol (accepted for publication)
19.
Zurück zum Zitat Delhaye D, Remy-Jardin M, Salem R, Teisseire A, Khalil C, Delannoy-Deken V, Duhamel A, Remy J (2005) Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system. Radiology (submitted for publication) Delhaye D, Remy-Jardin M, Salem R, Teisseire A, Khalil C, Delannoy-Deken V, Duhamel A, Remy J (2005) Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system. Radiology (submitted for publication)
20.
Zurück zum Zitat Lembcke A, Dohmen PM, Dewey M, Klessen C, Elgeti T, Hermann KG, Konertz W, Hamm B, Kivelitz DE (2005) Multislice computed tomography for preoperative evaluation of right ventricular volumes and function: comparison with magnetic resonance imaging. Ann Thorac Surg 79:1344–1351PubMedCrossRef Lembcke A, Dohmen PM, Dewey M, Klessen C, Elgeti T, Hermann KG, Konertz W, Hamm B, Kivelitz DE (2005) Multislice computed tomography for preoperative evaluation of right ventricular volumes and function: comparison with magnetic resonance imaging. Ann Thorac Surg 79:1344–1351PubMedCrossRef
21.
Zurück zum Zitat Koch K, Oellig F, Oberholzer K, Bender P, Kunz P, Mildenberger P, Hake U, Kreitner KF, Thelen M (2005) Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging. Eur Radiol 15:312–318PubMedCrossRef Koch K, Oellig F, Oberholzer K, Bender P, Kunz P, Mildenberger P, Hake U, Kreitner KF, Thelen M (2005) Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging. Eur Radiol 15:312–318PubMedCrossRef
22.
Zurück zum Zitat Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMedCrossRef Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMedCrossRef
23.
Zurück zum Zitat Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923PubMedCrossRef Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923PubMedCrossRef
24.
Zurück zum Zitat Flohr T, Stierstorfrer K, Raupach R, Ulzheimer S, Bruder H (2004) Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofö 176:1803–1810PubMed Flohr T, Stierstorfrer K, Raupach R, Ulzheimer S, Bruder H (2004) Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofö 176:1803–1810PubMed
25.
Zurück zum Zitat Hertzog C, Abolmaali N, Balzer JO, Baunach S, Ackerman H, Dogan S, Britten MB, Vogl TJ (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678 Hertzog C, Abolmaali N, Balzer JO, Baunach S, Ackerman H, Dogan S, Britten MB, Vogl TJ (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678
26.
Zurück zum Zitat National Heart Lung and Blood Institute Obesity Education Initiative Expert Panel (1998) Clinical guidelines on the identification, evaluation, and treatment of overweight and obesity in adults: the evidence report. National Heart, Lung and Blood Institute, Rockville, Maryland National Heart Lung and Blood Institute Obesity Education Initiative Expert Panel (1998) Clinical guidelines on the identification, evaluation, and treatment of overweight and obesity in adults: the evidence report. National Heart, Lung and Blood Institute, Rockville, Maryland
27.
Zurück zum Zitat American Heart Association Committee Report (1979) A reporting system on patients evaluated for coronary artery disease. Circulation 51:7–34 American Heart Association Committee Report (1979) A reporting system on patients evaluated for coronary artery disease. Circulation 51:7–34
28.
Zurück zum Zitat Schroeder S, Kopp AF, Kuettner A et al (2002) Influence of heart rate on vessel visibility in non-invasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clin Imaging 26:106–111PubMedCrossRef Schroeder S, Kopp AF, Kuettner A et al (2002) Influence of heart rate on vessel visibility in non-invasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clin Imaging 26:106–111PubMedCrossRef
29.
Zurück zum Zitat Zhang SZ, Hu XH, Zhang QW, Huang WX (2005) Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time. Eur Radiol 15:1105–1109PubMedCrossRef Zhang SZ, Hu XH, Zhang QW, Huang WX (2005) Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time. Eur Radiol 15:1105–1109PubMedCrossRef
30.
Zurück zum Zitat Hamoir XL, Flohr T, Hamoir V, Labaki L, Tricquet JY, Duhamel A, Kirsch J (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375 ms gantry rotation time. Eur Radiol 15:296–304PubMedCrossRef Hamoir XL, Flohr T, Hamoir V, Labaki L, Tricquet JY, Duhamel A, Kirsch J (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375 ms gantry rotation time. Eur Radiol 15:296–304PubMedCrossRef
31.
Zurück zum Zitat Pugliese F, Mollet NRA, Runza G, van Mieghem C, Meijboom WB, Malagutti P, Baks T, Krestin GP, deFeyter PJ, Cademartiri F (2005) Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol (early paper internet) Pugliese F, Mollet NRA, Runza G, van Mieghem C, Meijboom WB, Malagutti P, Baks T, Krestin GP, deFeyter PJ, Cademartiri F (2005) Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol (early paper internet)
32.
Zurück zum Zitat Wintersperger BJ, Nikolaou K (2005) Basics of cardiac MDCT: techniques and contrast application. Eur Radiol 15(suppl 2):B2–B9PubMed Wintersperger BJ, Nikolaou K (2005) Basics of cardiac MDCT: techniques and contrast application. Eur Radiol 15(suppl 2):B2–B9PubMed
33.
Zurück zum Zitat White CS, Kuo D, Kelemen M, Jain V, Musk A, Zaidi E, Read K, Sliker C, Prasad R (2005) Chest pain evaluation in the emergency department: can MDCT provide a comprehensive evaluation? AJR 185:533–540PubMed White CS, Kuo D, Kelemen M, Jain V, Musk A, Zaidi E, Read K, Sliker C, Prasad R (2005) Chest pain evaluation in the emergency department: can MDCT provide a comprehensive evaluation? AJR 185:533–540PubMed
34.
Zurück zum Zitat Coche E, Vlassznbroeck A, Roelants V, D’Hoore W, Verschuren F, Goncette L, Maldague B (2005) Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography. Eur Radiol 15:1432–1440PubMedCrossRef Coche E, Vlassznbroeck A, Roelants V, D’Hoore W, Verschuren F, Goncette L, Maldague B (2005) Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography. Eur Radiol 15:1432–1440PubMedCrossRef
35.
Zurück zum Zitat Kim TH, Ryu YH, Hur J, Kim SJ, Choi BW, Kim Y, Kim HJ (2005) Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography. Eur Radiol 15:1987–1993PubMedCrossRef Kim TH, Ryu YH, Hur J, Kim SJ, Choi BW, Kim Y, Kim HJ (2005) Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography. Eur Radiol 15:1987–1993PubMedCrossRef
36.
Zurück zum Zitat Delhaye D, Remy-Jardin M, Teisseire A, Hossein-Foucher C, Leroy S, Duhamel A, Remy J (2006) Estimation of right ventricular ejection fraction by multidetector row CT: comparison with equilibrium radionuclide scintigraphy. AJR (in press) Delhaye D, Remy-Jardin M, Teisseire A, Hossein-Foucher C, Leroy S, Duhamel A, Remy J (2006) Estimation of right ventricular ejection fraction by multidetector row CT: comparison with equilibrium radionuclide scintigraphy. AJR (in press)
Metadaten
Titel
Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients
verfasst von
Damien Delhaye
Martine Remy-Jardin
Céline Rozel
Catherine Dusson
Alain Wurtz
Valérie Delannoy-Deken
Alain Duhamel
Jacques Remy
Publikationsdatum
01.03.2007
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 3/2007
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0423-y

Weitere Artikel der Ausgabe 3/2007

European Radiology 3/2007 Zur Ausgabe

Update Radiologie