Skip to main content
Erschienen in: Pediatric Radiology 8/2014

01.08.2014 | Technical Innovation

Improved spatial resolution and lower-dose pediatric CT imaging: a feasibility study to evaluate narrowing the X-ray photon energy spectrum

verfasst von: Mark G. Benz, Matthew W. Benz, Steven B. Birnbaum, Eric Chason, Brian W. Sheldon, Dale McGuire

Erschienen in: Pediatric Radiology | Ausgabe 8/2014

Einloggen, um Zugang zu erhalten

Abstract

This feasibility study has shown that improved spatial resolution and reduced radiation dose can be achieved in pediatric CT by narrowing the X-ray photon energy spectrum. This is done by placing a hafnium filter between the X-ray generator and a pediatric abdominal phantom. A CT system manufactured in 1999 that was in the process of being remanufactured was used as the platform for this study. This system had the advantage of easy access to the X-ray generator for modifications to change the X-ray photon energy spectrum; it also had the disadvantage of not employing the latest post-imaging noise reduction iterative reconstruction technology. Because we observed improvements after changing the X-ray photon energy spectrum, we recommend a future study combining this change with an optimized iterative reconstruction noise reduction technique.
Literatur
1.
Zurück zum Zitat Brenner DJ, Elliston CD, Hall EJ et al (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176:289–296PubMedCrossRef Brenner DJ, Elliston CD, Hall EJ et al (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176:289–296PubMedCrossRef
2.
Zurück zum Zitat Boone JM, Seibert JA (1994) A figure of merit comparison between Bremsstrahlung and monoenergetic X-ray sources for angiography. J Xray Sci Technol 4:334–345PubMed Boone JM, Seibert JA (1994) A figure of merit comparison between Bremsstrahlung and monoenergetic X-ray sources for angiography. J Xray Sci Technol 4:334–345PubMed
3.
Zurück zum Zitat Mckinley RL, Tornai MP, Samei E et al (2004) Simulation study of a quasi-monochromatic beam for X-ray computed mammotomography. Med Phys 31:800–813PubMedCrossRef Mckinley RL, Tornai MP, Samei E et al (2004) Simulation study of a quasi-monochromatic beam for X-ray computed mammotomography. Med Phys 31:800–813PubMedCrossRef
4.
5.
Zurück zum Zitat Matsumoto T, Yoshino M, Asano T et al (1985) Monochromatic synchrotron radiation muCT reveals disuse-mediated canal network rarefaction in cortical bone of growing rat tibiae. J Appl Physiol 100:274–280CrossRef Matsumoto T, Yoshino M, Asano T et al (1985) Monochromatic synchrotron radiation muCT reveals disuse-mediated canal network rarefaction in cortical bone of growing rat tibiae. J Appl Physiol 100:274–280CrossRef
6.
Zurück zum Zitat Coolidge WD (1916) Vacuum tube, U.S. Patent 1,203,495, filed May 9, 1913 Coolidge WD (1916) Vacuum tube, U.S. Patent 1,203,495, filed May 9, 1913
7.
Zurück zum Zitat Goldman LW (2007) Principles of CT: radiation dose and image quality. J Nucl Med Tech 35:213–225CrossRef Goldman LW (2007) Principles of CT: radiation dose and image quality. J Nucl Med Tech 35:213–225CrossRef
8.
Zurück zum Zitat Slovis TL, Frush DP, Goske MJ (2013) An amazing accomplishment – CT manufacturers deserve our thanks. Pediatr Radiol 43:132–134PubMedCrossRef Slovis TL, Frush DP, Goske MJ (2013) An amazing accomplishment – CT manufacturers deserve our thanks. Pediatr Radiol 43:132–134PubMedCrossRef
Metadaten
Titel
Improved spatial resolution and lower-dose pediatric CT imaging: a feasibility study to evaluate narrowing the X-ray photon energy spectrum
verfasst von
Mark G. Benz
Matthew W. Benz
Steven B. Birnbaum
Eric Chason
Brian W. Sheldon
Dale McGuire
Publikationsdatum
01.08.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 8/2014
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-014-2893-4

Weitere Artikel der Ausgabe 8/2014

Pediatric Radiology 8/2014 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.