Skip to main content
Erschienen in: Acta Neurochirurgica 9/2019

21.06.2019 | Original Article - Spine - Other

Indication and technical implementation of the intraoperative neurophysiological monitoring during spine surgeries—a transnational survey in the German-speaking countries

verfasst von: Sebastian Siller, Constance Raith, Stefan Zausinger, Joerg-Christian Tonn, Andrea Szelenyi

Erschienen in: Acta Neurochirurgica | Ausgabe 9/2019

Einloggen, um Zugang zu erhalten

Abstract

Background

Intraoperative neurophysiological monitoring is widely used in spine surgery (sIONM). But guidelines are lacking and its use is mainly driven by individual surgeons’ preferences and medicolegal advisements. To gain an overview over the current status of sIONM implementation, we conducted a transnational survey in the German-speaking countries.

Methods

We developed a Web interface-based survey assessing prevalence, indication, technical implementation, and general satisfaction regarding sIONM in German, Austrian, and Swiss spine centers. The electronic survey was performed between November 2017 and April 2018, including both neurosurgical and orthopedic spine centers.

Results

A total of 463 German, 60 Austrian, and 52 Swiss spine centers were contacted with participation rates of 64.1% (Germany), 68.3% (Austria), and 55.8% (Switzerland). Some 75.9% participating neurosurgical spine centers and only 14.7% of the orthopedic spine centers applied sIONM. Motor- and somatosensory-evoked potentials (93.7% and 94.3%, respectively) were the most widely available modalities, followed by direct wave (D wave; 66.5%). Whereas sIONM utilization was low in spine surgeries for degenerative, traumatic, and extradural tumor diseases, it was high for scoliosis and intradural tumor surgeries. Overall, the general satisfaction within the institutional setting regarding technical skills, staff, performance, and reliability of sIONM was rated as “high” by more than three-quarters of the centers. However, shortage of skilled staff was claimed to be a negative factor by 41.1% of the centers and reimbursement was considered to be insufficient by 83.5%.

Conclusions

sIONM availability was high in neurosurgical but low in orthopedic spine centers. Main modalities were motor/somatosensory-evoked potentials and main indications were scoliosis and intradural spinal tumor surgeries. A more frequent sIONM use, however, was mainly limited by the shortage of skilled staff and restricted reimbursement.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Akay KM, Onder S (2002) Continuous neural monitoring in lumbar spine surgery. Experience with 101 patients. Minim Invasive Neurosurg 45(2):97–101CrossRefPubMed Akay KM, Onder S (2002) Continuous neural monitoring in lumbar spine surgery. Experience with 101 patients. Minim Invasive Neurosurg 45(2):97–101CrossRefPubMed
2.
Zurück zum Zitat Alemo S, Sayadipour A (2010) Role of intraoperative neurophysiologic monitoring in lumbosacral spine fusion and instrumentation. A retrospective study. World Neurosurg 73(1):72–76 discussion e7CrossRefPubMed Alemo S, Sayadipour A (2010) Role of intraoperative neurophysiologic monitoring in lumbosacral spine fusion and instrumentation. A retrospective study. World Neurosurg 73(1):72–76 discussion e7CrossRefPubMed
3.
Zurück zum Zitat Been HD, Kalkman CJ, Traast HS, Ongerboer de Visser BW (1994) Neurologic injury after insertion of laminar hooks during Cotrel-Dubousset instrumentation. Spine 19(12):1402–1405CrossRefPubMed Been HD, Kalkman CJ, Traast HS, Ongerboer de Visser BW (1994) Neurologic injury after insertion of laminar hooks during Cotrel-Dubousset instrumentation. Spine 19(12):1402–1405CrossRefPubMed
4.
Zurück zum Zitat Bose B, Wierzbowski LR, Sestokas AK (2002) Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery. Spine 27(13):1444–1450CrossRefPubMed Bose B, Wierzbowski LR, Sestokas AK (2002) Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery. Spine 27(13):1444–1450CrossRefPubMed
5.
Zurück zum Zitat Bose B, Sestokas AK, Schwartz DM (2004) Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion. Spine J 4(2):202–207CrossRefPubMed Bose B, Sestokas AK, Schwartz DM (2004) Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion. Spine J 4(2):202–207CrossRefPubMed
6.
Zurück zum Zitat Castellon AT, Meves R, Avanzi O (2009) Intraoperative neurophysiologic spinal cord monitoring in thoracolumbar burst fractures. Spine 34(24):2662–2668CrossRefPubMed Castellon AT, Meves R, Avanzi O (2009) Intraoperative neurophysiologic spinal cord monitoring in thoracolumbar burst fractures. Spine 34(24):2662–2668CrossRefPubMed
7.
Zurück zum Zitat Deletis V, Sala F (2008) Intraoperative neurophysiological monitoring of the spinal cord during spinal cord and spine surgery. A review focus on the corticospinal tracts. Clin Neurophysiol 119(2):248–264CrossRefPubMed Deletis V, Sala F (2008) Intraoperative neurophysiological monitoring of the spinal cord during spinal cord and spine surgery. A review focus on the corticospinal tracts. Clin Neurophysiol 119(2):248–264CrossRefPubMed
8.
Zurück zum Zitat Devlin VJ, Anderson PA, Schwartz DM, Vaughan R (2006) Intraoperative neurophysiologic monitoring. Focus on cervical myelopathy and related issues. Spine J 6(6 Suppl):212S–224SCrossRefPubMed Devlin VJ, Anderson PA, Schwartz DM, Vaughan R (2006) Intraoperative neurophysiologic monitoring. Focus on cervical myelopathy and related issues. Spine J 6(6 Suppl):212S–224SCrossRefPubMed
9.
Zurück zum Zitat Dimopoulos VG, Feltes CH, Fountas KN, Kapsalakis IZ, Vogel RL, Fuhrmann B, Grigorian AA, Johnston KW, Smisson HF, Robinson JS (2004) Does intraoperative electromyographic monitoring in lumbar microdiscectomy correlate with postoperative pain? South Med J 97(8):724–728CrossRefPubMed Dimopoulos VG, Feltes CH, Fountas KN, Kapsalakis IZ, Vogel RL, Fuhrmann B, Grigorian AA, Johnston KW, Smisson HF, Robinson JS (2004) Does intraoperative electromyographic monitoring in lumbar microdiscectomy correlate with postoperative pain? South Med J 97(8):724–728CrossRefPubMed
10.
Zurück zum Zitat Epstein NE, Danto J, Nardi D (1993) Evaluation of intraoperative somatosensory-evoked potential monitoring during 100 cervical operations. Spine 18(6):737–747CrossRefPubMed Epstein NE, Danto J, Nardi D (1993) Evaluation of intraoperative somatosensory-evoked potential monitoring during 100 cervical operations. Spine 18(6):737–747CrossRefPubMed
11.
Zurück zum Zitat Fehlings MG, Brodke DS, Norvell DC, Dettori JR (2010) The evidence for intraoperative neurophysiological monitoring in spine surgery. Does it make a difference? Spine 35(9 Suppl):S37–S46PubMed Fehlings MG, Brodke DS, Norvell DC, Dettori JR (2010) The evidence for intraoperative neurophysiological monitoring in spine surgery. Does it make a difference? Spine 35(9 Suppl):S37–S46PubMed
12.
Zurück zum Zitat Garcia RM, Qureshi SA, Cassinelli EH, Biro CL, Furey CG, Bohlman HH (2010) Detection of postoperative neurologic deficits using somatosensory-evoked potentials alone during posterior cervical laminoplasty. Spine J 10(10):890–895CrossRefPubMed Garcia RM, Qureshi SA, Cassinelli EH, Biro CL, Furey CG, Bohlman HH (2010) Detection of postoperative neurologic deficits using somatosensory-evoked potentials alone during posterior cervical laminoplasty. Spine J 10(10):890–895CrossRefPubMed
13.
Zurück zum Zitat Gavaret M, Jouve JL, Péréon Y, Accadbled F, André-Obadia N, Azabou E, Blondel B, Bollini G, Delécrin J, Farcy J-P, Fournet-Fayard J, Garin C, Henry P, Manel V, Mutschler V, Perrin G, Sales de Gauzy J (2013) Intraoperative neurophysiologic monitoring in spine surgery. Developments and state of the art in France in 2011. Orthop Traumatol Surg Res 99(6 Suppl):S319–S327CrossRefPubMed Gavaret M, Jouve JL, Péréon Y, Accadbled F, André-Obadia N, Azabou E, Blondel B, Bollini G, Delécrin J, Farcy J-P, Fournet-Fayard J, Garin C, Henry P, Manel V, Mutschler V, Perrin G, Sales de Gauzy J (2013) Intraoperative neurophysiologic monitoring in spine surgery. Developments and state of the art in France in 2011. Orthop Traumatol Surg Res 99(6 Suppl):S319–S327CrossRefPubMed
14.
Zurück zum Zitat Gonzalez AA, Jeyanandarajan D, Hansen C, Zada G, Hsieh PC (2009) Intraoperative neurophysiological monitoring during spine surgery. A review. Neurosurg Focus 27(4):E6CrossRef Gonzalez AA, Jeyanandarajan D, Hansen C, Zada G, Hsieh PC (2009) Intraoperative neurophysiological monitoring during spine surgery. A review. Neurosurg Focus 27(4):E6CrossRef
15.
Zurück zum Zitat Gundanna M, Eskenazi M, Bendo J, Spivak J, Moskovich R (2003) Somatosensory evoked potential monitoring of lumbar pedicle screw placement for in situ posterior spinal fusion. Spine J 3(5):370–376CrossRefPubMed Gundanna M, Eskenazi M, Bendo J, Spivak J, Moskovich R (2003) Somatosensory evoked potential monitoring of lumbar pedicle screw placement for in situ posterior spinal fusion. Spine J 3(5):370–376CrossRefPubMed
16.
Zurück zum Zitat Hamilton DK, Smith JS, Sansur CA, Glassman SD, Ames CP, Berven SH, Polly DW, Perra JH, Knapp DR, Boachie-Adjei O, McCarthy RE, Shaffrey CI (2011) Rates of new neurological deficit associated with spine surgery based on 108,419 procedures. A report of the scoliosis research society morbidity and mortality committee. Spine 36(15):1218–1228CrossRefPubMed Hamilton DK, Smith JS, Sansur CA, Glassman SD, Ames CP, Berven SH, Polly DW, Perra JH, Knapp DR, Boachie-Adjei O, McCarthy RE, Shaffrey CI (2011) Rates of new neurological deficit associated with spine surgery based on 108,419 procedures. A report of the scoliosis research society morbidity and mortality committee. Spine 36(15):1218–1228CrossRefPubMed
17.
Zurück zum Zitat Hilibrand AS, Schwartz DM, Sethuraman V, Vaccaro AR, Albert TJ (2004) Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery. J Bone Joint Surg Am 86-A(6):1248–1253CrossRef Hilibrand AS, Schwartz DM, Sethuraman V, Vaccaro AR, Albert TJ (2004) Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery. J Bone Joint Surg Am 86-A(6):1248–1253CrossRef
18.
Zurück zum Zitat James WS, Rughani AI, Dumont TM (2014) A socioeconomic analysis of intraoperative neurophysiological monitoring during spine surgery. National use, regional variation, and patient outcomes. Neurosurg Focus 37(5):E10CrossRefPubMed James WS, Rughani AI, Dumont TM (2014) A socioeconomic analysis of intraoperative neurophysiological monitoring during spine surgery. National use, regional variation, and patient outcomes. Neurosurg Focus 37(5):E10CrossRefPubMed
19.
Zurück zum Zitat Jin S-H, Chung CK, Kim CH, Choi YD, Kwak G, Kim BE (2015) Multimodal intraoperative monitoring during intramedullary spinal cord tumor surgery. Acta Neurochir 157(12):2149–2155CrossRefPubMed Jin S-H, Chung CK, Kim CH, Choi YD, Kwak G, Kim BE (2015) Multimodal intraoperative monitoring during intramedullary spinal cord tumor surgery. Acta Neurochir 157(12):2149–2155CrossRefPubMed
20.
Zurück zum Zitat Khan MH, Smith PN, Balzer JR, Crammond D, Welch WC, Gerszten P, Sclabassi RJ, Kang JD, Donaldson WF (2006) Intraoperative somatosensory evoked potential monitoring during cervical spine corpectomy surgery. Experience with 508 cases. Spine 31(4):E105–E113CrossRefPubMed Khan MH, Smith PN, Balzer JR, Crammond D, Welch WC, Gerszten P, Sclabassi RJ, Kang JD, Donaldson WF (2006) Intraoperative somatosensory evoked potential monitoring during cervical spine corpectomy surgery. Experience with 508 cases. Spine 31(4):E105–E113CrossRefPubMed
21.
Zurück zum Zitat Kothbauer KF (2007) Intraoperative neurophysiologic monitoring for intramedullary spinal-cord tumor surgery. Neurophysiol Clin 37(6):407–414CrossRefPubMed Kothbauer KF (2007) Intraoperative neurophysiologic monitoring for intramedullary spinal-cord tumor surgery. Neurophysiol Clin 37(6):407–414CrossRefPubMed
22.
Zurück zum Zitat Lall RR, Lall RR, Hauptman JS, Munoz C, Cybulski GR, Koski T, Ganju A, Fessler RG, Smith ZA (2012) Intraoperative neurophysiological monitoring in spine surgery. Indications, efficacy, and role of the preoperative checklist. Neurosurg Focus 33(5):E10CrossRef Lall RR, Lall RR, Hauptman JS, Munoz C, Cybulski GR, Koski T, Ganju A, Fessler RG, Smith ZA (2012) Intraoperative neurophysiological monitoring in spine surgery. Indications, efficacy, and role of the preoperative checklist. Neurosurg Focus 33(5):E10CrossRef
23.
Zurück zum Zitat Laratta JL, Shillingford JN, Ha A, Lombardi JM, Reddy HP, Saifi C, Ludwig SC, Lehman RA, Lenke LG (2018) Utilization of intraoperative neuromonitoring throughout the United States over a recent decade. An analysis of the nationwide inpatient sample. J Spine Surg 4(2):211–219CrossRefPubMedPubMedCentral Laratta JL, Shillingford JN, Ha A, Lombardi JM, Reddy HP, Saifi C, Ludwig SC, Lehman RA, Lenke LG (2018) Utilization of intraoperative neuromonitoring throughout the United States over a recent decade. An analysis of the nationwide inpatient sample. J Spine Surg 4(2):211–219CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Lee JY, Hilibrand AS, Lim MR, Zavatsky J, Zeiller S, Schwartz DM, Vaccaro AR, Anderson DG, Albert TJ (2006) Characterization of neurophysiologic alerts during anterior cervical spine surgery. Spine 31(17):1916–1922CrossRefPubMed Lee JY, Hilibrand AS, Lim MR, Zavatsky J, Zeiller S, Schwartz DM, Vaccaro AR, Anderson DG, Albert TJ (2006) Characterization of neurophysiologic alerts during anterior cervical spine surgery. Spine 31(17):1916–1922CrossRefPubMed
25.
Zurück zum Zitat Li F, Gorji R, Allott G, Modes K, Lunn R, Yang Z-J (2012) The usefulness of intraoperative neurophysiological monitoring in cervical spine surgery. A retrospective analysis of 200 consecutive patients. J Neurosurg Anesthesiol 24(3):185–190CrossRefPubMed Li F, Gorji R, Allott G, Modes K, Lunn R, Yang Z-J (2012) The usefulness of intraoperative neurophysiological monitoring in cervical spine surgery. A retrospective analysis of 200 consecutive patients. J Neurosurg Anesthesiol 24(3):185–190CrossRefPubMed
26.
Zurück zum Zitat Magit DP, Hilibrand AS, Kirk J, Rechtine G, Albert TJ, Vaccaro AR, Simpson AK, Grauer JN (2007) Questionnaire study of neuromonitoring availability and usage for spine surgery. J Spinal Disord Tech 20(4):282–289CrossRefPubMed Magit DP, Hilibrand AS, Kirk J, Rechtine G, Albert TJ, Vaccaro AR, Simpson AK, Grauer JN (2007) Questionnaire study of neuromonitoring availability and usage for spine surgery. J Spinal Disord Tech 20(4):282–289CrossRefPubMed
27.
Zurück zum Zitat Matsuyama Y, Sakai Y, Katayama Y, Imagama S, Ito Z, Wakao N, Sato K, Kamiya M, Yukawa Y, Kanemura T, Yanase M, Ishiguro N (2009) Surgical results of intramedullary spinal cord tumor with spinal cord monitoring to guide extent of resection. J Neurosurg Spine 10(5):404–413CrossRefPubMed Matsuyama Y, Sakai Y, Katayama Y, Imagama S, Ito Z, Wakao N, Sato K, Kamiya M, Yukawa Y, Kanemura T, Yanase M, Ishiguro N (2009) Surgical results of intramedullary spinal cord tumor with spinal cord monitoring to guide extent of resection. J Neurosurg Spine 10(5):404–413CrossRefPubMed
28.
Zurück zum Zitat Nuwer MR, Dawson EG, Carlson LG, Kanim LE, Sherman JE (1995) Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery. Results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 96(1):6–11CrossRefPubMed Nuwer MR, Dawson EG, Carlson LG, Kanim LE, Sherman JE (1995) Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery. Results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 96(1):6–11CrossRefPubMed
29.
Zurück zum Zitat Padberg AM, Wilson-Holden TJ, Lenke LG, Bridwell KH (1998) Somatosensory- and motor-evoked potential monitoring without a wake-up test during idiopathic scoliosis surgery. An accepted standard of care. Spine 23(12):1392–1400CrossRefPubMed Padberg AM, Wilson-Holden TJ, Lenke LG, Bridwell KH (1998) Somatosensory- and motor-evoked potential monitoring without a wake-up test during idiopathic scoliosis surgery. An accepted standard of care. Spine 23(12):1392–1400CrossRefPubMed
30.
Zurück zum Zitat Pajewski TN, Arlet V, Phillips LH (2007) Current approach on spinal cord monitoring. The point of view of the neurologist, the anesthesiologist and the spine surgeon. Eur Spine J 16(Suppl 2):S115–S129CrossRefPubMed Pajewski TN, Arlet V, Phillips LH (2007) Current approach on spinal cord monitoring. The point of view of the neurologist, the anesthesiologist and the spine surgeon. Eur Spine J 16(Suppl 2):S115–S129CrossRefPubMed
31.
Zurück zum Zitat Parker SL, Amin AG, Farber SH, McGirt MJ, Sciubba DM, Wolinsky J-P, Bydon A, Gokaslan ZL, Witham TF (2011) Ability of electromyographic monitoring to determine the presence of malpositioned pedicle screws in the lumbosacral spine. Analysis of 2450 consecutively placed screws. J Neurosurg Spine 15(2):130–135CrossRefPubMed Parker SL, Amin AG, Farber SH, McGirt MJ, Sciubba DM, Wolinsky J-P, Bydon A, Gokaslan ZL, Witham TF (2011) Ability of electromyographic monitoring to determine the presence of malpositioned pedicle screws in the lumbosacral spine. Analysis of 2450 consecutively placed screws. J Neurosurg Spine 15(2):130–135CrossRefPubMed
32.
Zurück zum Zitat Peeling L, Hentschel S, Fox R, Hall H, Fourney DR (2010) Intraoperative spinal cord and nerve root monitoring. A survey of Canadian spine surgeons. Can J Surg 53(5):324–328PubMedPubMedCentral Peeling L, Hentschel S, Fox R, Hall H, Fourney DR (2010) Intraoperative spinal cord and nerve root monitoring. A survey of Canadian spine surgeons. Can J Surg 53(5):324–328PubMedPubMedCentral
33.
Zurück zum Zitat Raynor BL, Lenke LG, Kim Y, Hanson DS, Wilson-Holden TJ, Bridwell KH, Padberg AM (2002) Can triggered electromyograph thresholds predict safe thoracic pedicle screw placement? Spine 27(18):2030–2035CrossRefPubMed Raynor BL, Lenke LG, Kim Y, Hanson DS, Wilson-Holden TJ, Bridwell KH, Padberg AM (2002) Can triggered electromyograph thresholds predict safe thoracic pedicle screw placement? Spine 27(18):2030–2035CrossRefPubMed
34.
Zurück zum Zitat Raynor BL, Lenke LG, Bridwell KH, Taylor BA, Padberg AM (2007) Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition. Analysis of 4857 screws. Spine 32(24):2673–2678CrossRefPubMed Raynor BL, Lenke LG, Bridwell KH, Taylor BA, Padberg AM (2007) Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition. Analysis of 4857 screws. Spine 32(24):2673–2678CrossRefPubMed
35.
Zurück zum Zitat Resnick DK, Choudhri TF, Dailey AT, Groff MW, Khoo L, Matz PG, Mummaneni P, Watters WC, Wang J, Walters BC, Hadley MN (2005) Guidelines for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 15. Electrophysiological monitoring and lumbar fusion. J Neurosurg Spine 2(6):725–732CrossRefPubMed Resnick DK, Choudhri TF, Dailey AT, Groff MW, Khoo L, Matz PG, Mummaneni P, Watters WC, Wang J, Walters BC, Hadley MN (2005) Guidelines for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 15. Electrophysiological monitoring and lumbar fusion. J Neurosurg Spine 2(6):725–732CrossRefPubMed
36.
Zurück zum Zitat Resnick DK, Anderson PA, Kaiser MG, Groff MW, Heary RF, Holly LT, Mummaneni PV, Ryken TC, Choudhri TF, Vresilovic EJ, Matz PG (2009) Electrophysiological monitoring during surgery for cervical degenerative myelopathy and radiculopathy. J Neurosurg Spine 11(2):245–252CrossRefPubMed Resnick DK, Anderson PA, Kaiser MG, Groff MW, Heary RF, Holly LT, Mummaneni PV, Ryken TC, Choudhri TF, Vresilovic EJ, Matz PG (2009) Electrophysiological monitoring during surgery for cervical degenerative myelopathy and radiculopathy. J Neurosurg Spine 11(2):245–252CrossRefPubMed
37.
Zurück zum Zitat Roh MS, Wilson-Holden TJ, Padberg AM, Park J-B, Daniel Riew K (2007) The utility of somatosensory evoked potential monitoring during cervical spine surgery. How often does it prompt intervention and affect outcome? Asian Spine J 1(1):43–47CrossRefPubMedPubMedCentral Roh MS, Wilson-Holden TJ, Padberg AM, Park J-B, Daniel Riew K (2007) The utility of somatosensory evoked potential monitoring during cervical spine surgery. How often does it prompt intervention and affect outcome? Asian Spine J 1(1):43–47CrossRefPubMedPubMedCentral
38.
Zurück zum Zitat Sala F, Palandri G, Basso E, Lanteri P, Deletis V, Faccioli F, Bricolo A (2006) Motor evoked potential monitoring improves outcome after surgery for intramedullary spinal cord tumors. A historical control study. Neurosurgery 58(6):1129–1143 discussion 1129-43CrossRefPubMed Sala F, Palandri G, Basso E, Lanteri P, Deletis V, Faccioli F, Bricolo A (2006) Motor evoked potential monitoring improves outcome after surgery for intramedullary spinal cord tumors. A historical control study. Neurosurgery 58(6):1129–1143 discussion 1129-43CrossRefPubMed
39.
Zurück zum Zitat Schwartz DM, Auerbach JD, Dormans JP, Flynn J, Drummond DS, Bowe JA, Laufer S, Shah SA, Bowen JR, Pizzutillo PD, Jones KJ (2007) Neurophysiological detection of impending spinal cord injury during scoliosis surgery. J Bone Joint Surg Am 89(11):2440–2449PubMed Schwartz DM, Auerbach JD, Dormans JP, Flynn J, Drummond DS, Bowe JA, Laufer S, Shah SA, Bowen JR, Pizzutillo PD, Jones KJ (2007) Neurophysiological detection of impending spinal cord injury during scoliosis surgery. J Bone Joint Surg Am 89(11):2440–2449PubMed
40.
Zurück zum Zitat Smith PN, Balzer JR, Khan MH, Davis RA, Crammond D, Welch WC, Gerszten P, Sclabassi RJ, Kang JD, Donaldson WF (2007) Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients—a review of 1,039 cases. Spine J 7(1):83–87CrossRefPubMed Smith PN, Balzer JR, Khan MH, Davis RA, Crammond D, Welch WC, Gerszten P, Sclabassi RJ, Kang JD, Donaldson WF (2007) Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients—a review of 1,039 cases. Spine J 7(1):83–87CrossRefPubMed
41.
Zurück zum Zitat Traynelis VC, Abode-Iyamah KO, Leick KM, Bender SM, Greenlee JDW (2012) Cervical decompression and reconstruction without intraoperative neurophysiological monitoring. J Neurosurg Spine 16(2):107–113CrossRefPubMed Traynelis VC, Abode-Iyamah KO, Leick KM, Bender SM, Greenlee JDW (2012) Cervical decompression and reconstruction without intraoperative neurophysiological monitoring. J Neurosurg Spine 16(2):107–113CrossRefPubMed
42.
Zurück zum Zitat Uribe JS, Vale FL, Dakwar E (2010) Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery. Spine 35(26 Suppl):S368–S374CrossRefPubMed Uribe JS, Vale FL, Dakwar E (2010) Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery. Spine 35(26 Suppl):S368–S374CrossRefPubMed
43.
Zurück zum Zitat Weiss DS (2001) Spinal cord and nerve root monitoring during surgical treatment of lumbar stenosis. Clin Orthop Relat Res 384:82–100CrossRef Weiss DS (2001) Spinal cord and nerve root monitoring during surgical treatment of lumbar stenosis. Clin Orthop Relat Res 384:82–100CrossRef
44.
Zurück zum Zitat Yarger JB, James TA, Ashikaga T, Hayanga AJ, Takyi V, Lum Y, Kaiser H, Mammen J (2013) Characteristics in response rates for surveys administered to surgery residents. Surgery 154(1):38–45CrossRefPubMed Yarger JB, James TA, Ashikaga T, Hayanga AJ, Takyi V, Lum Y, Kaiser H, Mammen J (2013) Characteristics in response rates for surveys administered to surgery residents. Surgery 154(1):38–45CrossRefPubMed
Metadaten
Titel
Indication and technical implementation of the intraoperative neurophysiological monitoring during spine surgeries—a transnational survey in the German-speaking countries
verfasst von
Sebastian Siller
Constance Raith
Stefan Zausinger
Joerg-Christian Tonn
Andrea Szelenyi
Publikationsdatum
21.06.2019
Verlag
Springer Vienna
Erschienen in
Acta Neurochirurgica / Ausgabe 9/2019
Print ISSN: 0001-6268
Elektronische ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-019-03974-6

Weitere Artikel der Ausgabe 9/2019

Acta Neurochirurgica 9/2019 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.