Skip to main content
Erschienen in: Japanese Journal of Radiology 4/2019

31.01.2019 | Original Article

Initial clinical experience of a prototype ultra-high-resolution CT for assessment of small intracranial arteries

verfasst von: Hiroyuki Nagata, Kazuhiro Murayama, Shigetaka Suzuki, Ayumi Watanabe, Motoharu Hayakawa, Yasuo Saito, Kazuhiro Katada, Hiroshi Toyama

Erschienen in: Japanese Journal of Radiology | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Diagnostic and neurosurgical procedures require the precise localization of small intracranial arteries, but this may be difficult using conventional computed tomography angiography (CTA). This study was conducted to evaluate the quality of CTA images acquired using a prototype ultra-high-resolution computed tomography (U-HRCT) system compared with those acquired using a conventional computed tomography (C-CT) system.

Materials and methods

From July through September 2015, 10 adult patients (6 women and 4 men) previously scanned by C-CT were examined using U-HRCT to locate and assess cerebral aneurysms. The bilateral ophthalmic artery (Opth A), anterior choroidal artery (Acho A), and thalamoperforating arteries (TPAs) were visually evaluated in randomly presented CTA images. Images were graded on a 5-point scale, and differences in scores between U-HRCT and C-CT were evaluated by the Wilcoxon signed-rank test. A p value < 0.05 was considered statistically significant.

Results

Visual evaluation scores for images of the Opth A, Acho A, and TPAs were significantly higher for U-HRCT than for C-CT. U-HRCT images achieved good visualization (score > 3) for C-CT images with poor visualization (score < 3) in 66.7–100% of all the small arteries.

Conclusion

U-HRCT is superior to C-CT for detecting and evaluating clinically significant small intracranial arteries.
Literatur
1.
Zurück zum Zitat Rhoton AL Jr, Fujii K, Fradd B. Microsurgical anatomy of the anterior choroidal artery. Surg Neurol. 1979;12(2):171–87.PubMed Rhoton AL Jr, Fujii K, Fradd B. Microsurgical anatomy of the anterior choroidal artery. Surg Neurol. 1979;12(2):171–87.PubMed
2.
Zurück zum Zitat Rosner SS, Rhoton AL Jr, Ono M, Barry M. Microsurgical anatomy of the anterior perforating arteries. J Neurosurg. 1984;61:468–85.CrossRefPubMed Rosner SS, Rhoton AL Jr, Ono M, Barry M. Microsurgical anatomy of the anterior perforating arteries. J Neurosurg. 1984;61:468–85.CrossRefPubMed
3.
Zurück zum Zitat Segarra JM. Cerebral vascular disease and behavior. I. The syndrome of the mesencephalic artery (basilar artery bifurcation). Arch Neurol. 1970;22:408–18.CrossRefPubMed Segarra JM. Cerebral vascular disease and behavior. I. The syndrome of the mesencephalic artery (basilar artery bifurcation). Arch Neurol. 1970;22:408–18.CrossRefPubMed
4.
Zurück zum Zitat Castaigne P, Lhermitte F, Buge A, Escourolle R, Hauw JJ, Lyon-Caen O. Paramedian thalamic and mid brain infarct: clinical and neuropathological study. Ann Neurol. 1981;10:127–48.CrossRefPubMed Castaigne P, Lhermitte F, Buge A, Escourolle R, Hauw JJ, Lyon-Caen O. Paramedian thalamic and mid brain infarct: clinical and neuropathological study. Ann Neurol. 1981;10:127–48.CrossRefPubMed
5.
Zurück zum Zitat Lazzaro NA, Wright B, Castillo M, Fischbein NJ, Glastonbury CM, et al. Artery of percheron infarction: imaging patterns and clinical spectrum. AJNR Am J Neuroradiol. 2010;31:1283–9.CrossRefPubMed Lazzaro NA, Wright B, Castillo M, Fischbein NJ, Glastonbury CM, et al. Artery of percheron infarction: imaging patterns and clinical spectrum. AJNR Am J Neuroradiol. 2010;31:1283–9.CrossRefPubMed
6.
Zurück zum Zitat Kakinuma R, Moriyama N, Muramatsu Y, Gomi S, Suzuki M, Nagasawa H, et al. Ultra-high-resolution computed tomography of the lung: image quality of a prototype scanner. PLoS ONE. 2015;10:e0137165.CrossRefPubMedPubMedCentral Kakinuma R, Moriyama N, Muramatsu Y, Gomi S, Suzuki M, Nagasawa H, et al. Ultra-high-resolution computed tomography of the lung: image quality of a prototype scanner. PLoS ONE. 2015;10:e0137165.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Zhu H, Zhang L, Wang Y, Hamal P, You X, Mao H, et al. Improved image quality and diagnostic potential using ultra-high-resolution computed tomography of the lung with small scan FOV: a prospective study. PLoS ONE. 2017;12:e0172688.CrossRefPubMedPubMedCentral Zhu H, Zhang L, Wang Y, Hamal P, You X, Mao H, et al. Improved image quality and diagnostic potential using ultra-high-resolution computed tomography of the lung with small scan FOV: a prospective study. PLoS ONE. 2017;12:e0172688.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Sheshadri A, Rodriguez A, Chen R, Kozlowski J, Burgdorf D, Koch T, et al. Effect of reducing field of view on multidetector quantitative computed tomography parameters of airway wall thickness in asthma. J Comput Assist Tomogr. 2015;39:584–90.CrossRefPubMedPubMedCentral Sheshadri A, Rodriguez A, Chen R, Kozlowski J, Burgdorf D, Koch T, et al. Effect of reducing field of view on multidetector quantitative computed tomography parameters of airway wall thickness in asthma. J Comput Assist Tomogr. 2015;39:584–90.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Hata A, Yanagawa M, Honda O, Kikuchi N, Miyata T, Tsukagoshi S, et al. Effect of matrix size on the image quality of ultra-high-resolution CT of the lung: comparison of 512 × 512, 1024 × 1024, and 2048 × 2048. Acad Radiol. 2018;25:869–76.CrossRefPubMed Hata A, Yanagawa M, Honda O, Kikuchi N, Miyata T, Tsukagoshi S, et al. Effect of matrix size on the image quality of ultra-high-resolution CT of the lung: comparison of 512 × 512, 1024 × 1024, and 2048 × 2048. Acad Radiol. 2018;25:869–76.CrossRefPubMed
10.
Zurück zum Zitat Yoshioka K, Tanaka R, Takagi H, Ueyama Y, Kikuchi K, Chiba T, et al. Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study. Neuroradiology. 2018;60:109–15.CrossRefPubMed Yoshioka K, Tanaka R, Takagi H, Ueyama Y, Kikuchi K, Chiba T, et al. Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study. Neuroradiology. 2018;60:109–15.CrossRefPubMed
11.
Zurück zum Zitat Matsuki M, Murakami T, Juri H, Yoshikawa S, Narumi Y. Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection. Acta Radiol. 2013;54:869–75.CrossRefPubMed Matsuki M, Murakami T, Juri H, Yoshikawa S, Narumi Y. Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection. Acta Radiol. 2013;54:869–75.CrossRefPubMed
12.
Zurück zum Zitat Moscariello A, Takx RA, Schoepf UJ, Renker M, Zwerner PL, O’Brien TX, et al. CoronaryCT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. EurRadiol. 2011;21:2130–8. Moscariello A, Takx RA, Schoepf UJ, Renker M, Zwerner PL, O’Brien TX, et al. CoronaryCT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. EurRadiol. 2011;21:2130–8.
13.
Zurück zum Zitat Singh S, Kalra MK, Gilman MD, Hsieh J, Pien HH, Digumarthy SR, et al. Adaptivestatisticaliterativereconstructiontechnique for radiation dose reduction in chest CT: a pilot study. Radiology. 2011;259:565–73.CrossRefPubMed Singh S, Kalra MK, Gilman MD, Hsieh J, Pien HH, Digumarthy SR, et al. Adaptivestatisticaliterativereconstructiontechnique for radiation dose reduction in chest CT: a pilot study. Radiology. 2011;259:565–73.CrossRefPubMed
14.
Zurück zum Zitat Kalra MK, Woisetschläger M, Dahlström N, Singh S, Lindblom M, Choy G, et al. Radiationdosereduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography. J Comput Assist Tomogr. 2012;36(3):339–46.CrossRefPubMed Kalra MK, Woisetschläger M, Dahlström N, Singh S, Lindblom M, Choy G, et al. Radiationdosereduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography. J Comput Assist Tomogr. 2012;36(3):339–46.CrossRefPubMed
15.
Zurück zum Zitat Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF. Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke. 2013;44:442–7.CrossRefPubMed Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF. Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke. 2013;44:442–7.CrossRefPubMed
16.
Zurück zum Zitat Heiskanen O. Risks of surgery for unruptured intracranial aneurysms. J Neurosurg. 1986;65:451–3.CrossRefPubMed Heiskanen O. Risks of surgery for unruptured intracranial aneurysms. J Neurosurg. 1986;65:451–3.CrossRefPubMed
18.
Zurück zum Zitat Griessenauer CJ, Loukas M, Tubbs RS, Cohen-Gadol AA. The artery of Percheron: an anatomic study with potential neurosurgical and neuroendovascular importance. Br J Neurosurg. 2014;28:81–5.CrossRefPubMed Griessenauer CJ, Loukas M, Tubbs RS, Cohen-Gadol AA. The artery of Percheron: an anatomic study with potential neurosurgical and neuroendovascular importance. Br J Neurosurg. 2014;28:81–5.CrossRefPubMed
19.
Zurück zum Zitat Kocaeli H, Yilmazlar S, Kuytu T, Korfalı E. The artery of Percheron revisited: a cadaveric anatomical study. Acta Neurochir (Wien). 2013;155:533–9.CrossRefPubMed Kocaeli H, Yilmazlar S, Kuytu T, Korfalı E. The artery of Percheron revisited: a cadaveric anatomical study. Acta Neurochir (Wien). 2013;155:533–9.CrossRefPubMed
20.
Zurück zum Zitat Marinković S, Gibo H, Brigante L, Nikodijević I, Petrović P. The surgical anatomy of the perforating branches of the anterior choroidal artery. Surg Neurol. 1999;52(1):30–6.CrossRefPubMed Marinković S, Gibo H, Brigante L, Nikodijević I, Petrović P. The surgical anatomy of the perforating branches of the anterior choroidal artery. Surg Neurol. 1999;52(1):30–6.CrossRefPubMed
21.
Zurück zum Zitat Saeki N, Rhoton AL Jr. Microsurgical anatomy of the upper basilar artery and the posterior circle of Willis. J Neurosurg. 1977;46(5):563–78.CrossRefPubMed Saeki N, Rhoton AL Jr. Microsurgical anatomy of the upper basilar artery and the posterior circle of Willis. J Neurosurg. 1977;46(5):563–78.CrossRefPubMed
22.
Zurück zum Zitat Kim SH, Yeo DK, Shim JJ, Yoon SM, Chang JC, Bae HG. Morphometric study of the anterior thalamoperforating arteries. J Korean Neurosurg Soc. 2015;57(5):350–8.CrossRefPubMedPubMedCentral Kim SH, Yeo DK, Shim JJ, Yoon SM, Chang JC, Bae HG. Morphometric study of the anterior thalamoperforating arteries. J Korean Neurosurg Soc. 2015;57(5):350–8.CrossRefPubMedPubMedCentral
Metadaten
Titel
Initial clinical experience of a prototype ultra-high-resolution CT for assessment of small intracranial arteries
verfasst von
Hiroyuki Nagata
Kazuhiro Murayama
Shigetaka Suzuki
Ayumi Watanabe
Motoharu Hayakawa
Yasuo Saito
Kazuhiro Katada
Hiroshi Toyama
Publikationsdatum
31.01.2019
Verlag
Springer Japan
Erschienen in
Japanese Journal of Radiology / Ausgabe 4/2019
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-019-00816-4

Weitere Artikel der Ausgabe 4/2019

Japanese Journal of Radiology 4/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.