Transpedicular screwing of the seventh cervical vertebra: anatomical considerations and surgical technique

verfasst von: C. Barrey, F. Cotton, J. Jund, P. Mertens, G. Perrin

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 5-6/2003

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was first to assess the feasibility of C7 transpedicular screwing with a morphological study and secondly to evaluate the safety of such a surgical technique when guided only by posterior landmarks. Eighteen C7 vertebrae, harvested from fresh human cadavers, were included in this study. First the morphometry of C7 pedicle was performed on computed tomography with multiplanar reconstructions. Results of this quantitative anatomy were compared with the literature data. Secondly 30 pedicle screws, whose placement was guided only by anatomical features on the posterior face of the dorsal arch, were inserted in 15 C7 vertebrae. A second computed tomographic examination was done after the surgical procedure to check the screw placement in both planes. The average pedicular width was 6±1.2 mm and the average height was 5.8±1.1 mm. The pedicle angulation in the transverse plane was 33.3°±6.6°, the pedicle angulation in the sagittal plane was 4.3°±4.5° downward with reference to the lower endplate of C7. The average distance from the entry point of transpedicular screwing to the anterior cortex of the vertebral body was 29±3 mm. Concerning the safety of transpedicular screwing, 63% of screws were found entirely inside the pedicle without any violation of the pedicle cortex. Most of pedicle violations were observed in the transverse plane. No grade II violation of the pedicle was observed. Dimensions of the C7 pedicle are amply compatible with transpedicular fixation using 3.5 mm screws. Such a surgical technique seems to be an interesting option when posterior fixation of C7 is required. Nevertheless morphological guidelines appeared not to be sufficient to ensure safe transpedicular screwing. Laminoforaminotomy is strongly recommended, although it has not been evaluated in this study.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7: 19–28PubMed Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7: 19–28PubMed
2.
Zurück zum Zitat Abumi K, Kaneda K (1997) Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22: 1853–1863CrossRefPubMed Abumi K, Kaneda K (1997) Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22: 1853–1863CrossRefPubMed
3.
Zurück zum Zitat Abumi K, Kaneda K, Shono Y, Fujiya M (1999) One-stage decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg (Spine 1) 90: 19–26 Abumi K, Kaneda K, Shono Y, Fujiya M (1999) One-stage decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg (Spine 1) 90: 19–26
4.
Zurück zum Zitat Albert TJ, Klein GR, Joffe D, Vaccaro AR (1998) Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology. Spine 23: 1596–1599CrossRefPubMed Albert TJ, Klein GR, Joffe D, Vaccaro AR (1998) Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology. Spine 23: 1596–1599CrossRefPubMed
5.
Zurück zum Zitat Ebraheim NA, Xu R, Yeasting RA (1996) The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation. Spine 21: 1291–1295CrossRefPubMed Ebraheim NA, Xu R, Yeasting RA (1996) The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation. Spine 21: 1291–1295CrossRefPubMed
6.
Zurück zum Zitat Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine 22: 1-5CrossRefPubMed Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine 22: 1-5CrossRefPubMed
7.
Zurück zum Zitat Francke JP (1971) Contribution à l'étude des artères vertébrales. Recherche anatomique. Thesis, Lille Francke JP (1971) Contribution à l'étude des artères vertébrales. Recherche anatomique. Thesis, Lille
8.
Zurück zum Zitat Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7: 222–229PubMed Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7: 222–229PubMed
9.
Zurück zum Zitat Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws, anatomic feasibility and biomechanical comparison. Spine 22: 977–982CrossRefPubMed Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws, anatomic feasibility and biomechanical comparison. Spine 22: 977–982CrossRefPubMed
10.
Zurück zum Zitat Jovanovic MS (1990) A comparative study of the transverse foramen of the sixth and seventh cervical vertebrae. Surg Radiol Anat 12: 167–172PubMed Jovanovic MS (1990) A comparative study of the transverse foramen of the sixth and seventh cervical vertebrae. Surg Radiol Anat 12: 167–172PubMed
11.
Zurück zum Zitat Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13: 218–224CrossRefPubMed Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13: 218–224CrossRefPubMed
12.
Zurück zum Zitat Karaikovic EE, Daubs MD, Madsen RW, Gaines RW (1997) Morphologic characteristics of human cervical pedicles. Spine 22:493–500CrossRefPubMed Karaikovic EE, Daubs MD, Madsen RW, Gaines RW (1997) Morphologic characteristics of human cervical pedicles. Spine 22:493–500CrossRefPubMed
13.
Zurück zum Zitat Karaikovic EE, Yingsakmongkol W, Gaines RW (2001) Accuracy of cervical pedicle screw placement using the funnel technique. Spine 26: 2456–2462CrossRefPubMed Karaikovic EE, Yingsakmongkol W, Gaines RW (2001) Accuracy of cervical pedicle screw placement using the funnel technique. Spine 26: 2456–2462CrossRefPubMed
14.
Zurück zum Zitat Kotani Y, Cunningham BW, Abumi K, McAfee P (1994) Biomechanical analysis of cervical stabilization systems: an assessment of transpedicular screw fixation in the cervical spine. Spine 19: 2529–2539PubMed Kotani Y, Cunningham BW, Abumi K, McAfee P (1994) Biomechanical analysis of cervical stabilization systems: an assessment of transpedicular screw fixation in the cervical spine. Spine 19: 2529–2539PubMed
15.
Zurück zum Zitat Kowalski JM, Ludwig SC, Hutton WC, Heller JG (2000) Cervical spine pedicle screws, a biomechanical comparison of two insertion techniques. Spine 25: 2865–2867CrossRefPubMed Kowalski JM, Ludwig SC, Hutton WC, Heller JG (2000) Cervical spine pedicle screws, a biomechanical comparison of two insertion techniques. Spine 25: 2865–2867CrossRefPubMed
16.
Zurück zum Zitat Le Double AF (1912) Traité des variations de la colonne vertébrale de l'homme. Vigot Frères, Paris, pp 1–48 Le Double AF (1912) Traité des variations de la colonne vertébrale de l'homme. Vigot Frères, Paris, pp 1–48
17.
Zurück zum Zitat Ludwig SC, Kramer DL, Vaccaro AR, Albert TJ (1999) Transpedicle screw fixation of the cervical spine. Clin Orthop 359: 77–88PubMed Ludwig SC, Kramer DL, Vaccaro AR, Albert TJ (1999) Transpedicle screw fixation of the cervical spine. Clin Orthop 359: 77–88PubMed
18.
Zurück zum Zitat Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ (2000) Placement of pedicle screws in the human cadaveric cervical spine. Spine 25: 1655–1667CrossRefPubMed Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ (2000) Placement of pedicle screws in the human cadaveric cervical spine. Spine 25: 1655–1667CrossRefPubMed
19.
Zurück zum Zitat McCulloch JA, Young PH (1998) Essentials of spinal microsurgery. Lippincott-Raven, Philadelphia, pp 121–150 McCulloch JA, Young PH (1998) Essentials of spinal microsurgery. Lippincott-Raven, Philadelphia, pp 121–150
20.
Zurück zum Zitat Miller RM, Ebraheim NA, Xu R, Yeasting RA (1996) Anatomic considerations of transpedicular screw placement in the cervical spine. Spine 21: 2317–2322CrossRefPubMed Miller RM, Ebraheim NA, Xu R, Yeasting RA (1996) Anatomic considerations of transpedicular screw placement in the cervical spine. Spine 21: 2317–2322CrossRefPubMed
21.
Zurück zum Zitat Panjabi M, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebrae, quantitative three-dimensional anatomy of the middle and lower regions. Spine 16: 861–869PubMed Panjabi M, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebrae, quantitative three-dimensional anatomy of the middle and lower regions. Spine 16: 861–869PubMed
22.
Zurück zum Zitat Ugur HC, Attar A, Uz A, Egemen N, Caglar S, Genc Y (2000) Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47: 1162–1169PubMed Ugur HC, Attar A, Uz A, Egemen N, Caglar S, Genc Y (2000) Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47: 1162–1169PubMed
23.
Zurück zum Zitat Xu R, Ebraheim NA, Yeasting R, Wong F, Jackson WT (1995) Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect. J Spinal Disord 8: 116–120PubMed Xu R, Ebraheim NA, Yeasting R, Wong F, Jackson WT (1995) Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect. J Spinal Disord 8: 116–120PubMed
24.
Zurück zum Zitat Xu R, Kang A, Ebraheim NA, Yeasting RA (1999) Anatomic relation between the cervical pedicle and the adjacent neural structures. Spine 24: 451–454CrossRefPubMed Xu R, Kang A, Ebraheim NA, Yeasting RA (1999) Anatomic relation between the cervical pedicle and the adjacent neural structures. Spine 24: 451–454CrossRefPubMed
Metadaten
Titel
Transpedicular screwing of the seventh cervical vertebra: anatomical considerations and surgical technique
verfasst von
C. Barrey
F. Cotton
J. Jund
P. Mertens
G. Perrin
Publikationsdatum
01.12.2003
Verlag
Springer-Verlag
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 5-6/2003
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-003-0163-5

Weitere Artikel der Ausgabe 5-6/2003

Surgical and Radiologic Anatomy 5-6/2003 Zur Ausgabe

Anatomic Bases of Medical, Radiological and Surgical Techniques

Sural flap vascularization in arteritic patients: an anatomic study of 24 amputation specimens

Anatomic Bases of Medical, Radiological and Surgical Techniques

The acetabular blood supply: implications for periacetabular osteotomies

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.