01.10.2003 | Chest

Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness

verfasst von: Frank Fischbach, Friedrich Knollmann, Volker Griesshaber, Torsten Freund, Ethem Akkol, Roland Felix

Erschienen in: European Radiology | Ausgabe 10/2003

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to find out if the use of 1.25-mm collimated thin-slice technique helps to detect more small pulmonary lung nodules than the use of 5 mm. A total of 100 patient examinations that allowed a reconstruction of 1.25-mm slice thickness in addition to the standard of 5-mm slices were included in a prospective study. Acquisition technique included four rows of 1-mm slices. Two sets of contiguous images were reconstructed and compared with 1.25- and 5-mm slice thickness, respectively. Two radiologists performed a film-based analysis of the images. The size and the confidence of the seen nodules were reported. We did not perform a histological verification, according to the normal clinical procedure, although it would be optimal regarding research. Statistical analysis was performed by using longitudinal analysis described by Brunner and Langer [10]. In addition, sensitivity, specificity, negative predictive value and positive predictive value were calculated for each reader using the 1.25-mm sections as the gold standard. As an index for concordance the kappa value was used. A value of p<0.05 was regarded as significant. In 37 patients pulmonary nodules were detected. Twenty-four patients showed more than one nodule; among these, 7 patients had disseminated disease and were excluded from the study. Pulmonary nodules larger than 10 mm in size were equally well depicted with both modalities, whereas lesions smaller than 5 mm in size were significantly better depicted with 1.25 mm (p<0.05). Using 1.25 mm as the gold standard, sensitivity for 5-mm reconstruction interval was 88 and 86% for observers A and B, respectively. No false-positive results were reported for 5-mm sections. Interobserver agreement for nodule detection determined for 1.25-mm reconstruction intervals showed a k value of 0.753, indicating a good agreement, and 0.562 for 5-mm reconstruction intervals, indicating a moderate agreement. Brunner and Langer [10] analysis showed significant differences for slice thickness and no significant difference between the observers. Reduced slice thickness demonstrated an improvement of small nodule detection, confidence levels, and interobserver agreement. Application of thin-slice multidetector-row CT may raise the sensitivity for lung nodule detection, although the higher detection rate of smaller nodules has to be evaluated from a clinical perspective and remains problematic about how the detection of small nodules will effect patient outcome.
Literatur
1.
Zurück zum Zitat Theros EG (1977) Caldwell Lecture: varying manifestation of peripheral pulmonary neoplasms. A radiologic–pathologic correlative study. Am J Roentgenol 128:893–914 Theros EG (1977) Caldwell Lecture: varying manifestation of peripheral pulmonary neoplasms. A radiologic–pathologic correlative study. Am J Roentgenol 128:893–914
2.
Zurück zum Zitat Van Klaveren RJ, Habbema JDF, Pedersen JH, de Koning HJ, Oudkerk M, Hoogsteden HC (2001) Lung cancer screening by low-dose spiral computed tomography. Eur Respir J 18:857–866CrossRefPubMed Van Klaveren RJ, Habbema JDF, Pedersen JH, de Koning HJ, Oudkerk M, Hoogsteden HC (2001) Lung cancer screening by low-dose spiral computed tomography. Eur Respir J 18:857–866CrossRefPubMed
3.
Zurück zum Zitat Muhm JR, Brown LR, Crowe JK, Sheedy PF II, Hattery RR, Stephens DH (1978) Comparison of whole-lung tomography and computed tomography for detecting pulmonary nodules. Am J Roentgenol 131:981–984 Muhm JR, Brown LR, Crowe JK, Sheedy PF II, Hattery RR, Stephens DH (1978) Comparison of whole-lung tomography and computed tomography for detecting pulmonary nodules. Am J Roentgenol 131:981–984
4.
Zurück zum Zitat Costello P, Anderson W, Blume D (1991) Pulmonary nodule: evaluation with spiral volumetric CT. Radiology 179:875–876PubMed Costello P, Anderson W, Blume D (1991) Pulmonary nodule: evaluation with spiral volumetric CT. Radiology 179:875–876PubMed
5.
Zurück zum Zitat Remy-Jardin M, Remy J, Giraud F, Marquette CH (1993) Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. Radiology 187:513–520PubMed Remy-Jardin M, Remy J, Giraud F, Marquette CH (1993) Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. Radiology 187:513–520PubMed
6.
Zurück zum Zitat Hu H, He HD, Foley WD, Fox SH (2000) Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 215:55–62 Hu H, He HD, Foley WD, Fox SH (2000) Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 215:55–62
7.
Zurück zum Zitat Diederich S, Semik M, Lentschig MG, Winter F, Scheld HH, Roos N et al. (1999) Helical CT of pulmonary nodules in patients with extrathoracic malignancy: CT-surgical correlation. Am J Roentgenol 172:353–360 Diederich S, Semik M, Lentschig MG, Winter F, Scheld HH, Roos N et al. (1999) Helical CT of pulmonary nodules in patients with extrathoracic malignancy: CT-surgical correlation. Am J Roentgenol 172:353–360
8.
Zurück zum Zitat Wormanns D, Diederich S, Lentschig MG, Winter F, Heindel W (2000) Spiral CT of pulmonary nodules: interobserver variation in assessment of lesion size. Eur Radiol 10:710–713CrossRefPubMed Wormanns D, Diederich S, Lentschig MG, Winter F, Heindel W (2000) Spiral CT of pulmonary nodules: interobserver variation in assessment of lesion size. Eur Radiol 10:710–713CrossRefPubMed
9.
Zurück zum Zitat Austin JH, Muller NL, Friedman PJ, Hansell DM, Naidich DP, Remy-Jardin M et al. (1996) Glossary of terms for CT of the lungs: recommendations of the Nomenclature Committee of the Fleischner Society. Radiology 200:327–331PubMed Austin JH, Muller NL, Friedman PJ, Hansell DM, Naidich DP, Remy-Jardin M et al. (1996) Glossary of terms for CT of the lungs: recommendations of the Nomenclature Committee of the Fleischner Society. Radiology 200:327–331PubMed
10.
Zurück zum Zitat Brunner E, Langer F (1999) Nicht parametrische Analyse longitudinaler Daten Oldenburgverlag, München Brunner E, Langer F (1999) Nicht parametrische Analyse longitudinaler Daten Oldenburgverlag, München
11.
Zurück zum Zitat Davis SD (1991) CT evaluation for pulmonary metastases in patients with extrathoracic malignancy. Radiology 180:1–12PubMed Davis SD (1991) CT evaluation for pulmonary metastases in patients with extrathoracic malignancy. Radiology 180:1–12PubMed
12.
Zurück zum Zitat Collie DA, Wright AR, Williams JR, Hashemi-Malayeri B, Stevenson AJ, Turnbull CM (1994) Comparison of spiral-acquisition computed tomography and conventional computed tomography in the assessment of pulmonary metastatic disease. Br J Radiol 67:436–444PubMed Collie DA, Wright AR, Williams JR, Hashemi-Malayeri B, Stevenson AJ, Turnbull CM (1994) Comparison of spiral-acquisition computed tomography and conventional computed tomography in the assessment of pulmonary metastatic disease. Br J Radiol 67:436–444PubMed
13.
Zurück zum Zitat Paranjpe DV, Bergin CJ (1994) Spiral CT of the lungs: optimal technique and resolution compared with conventional CT. Am J Roentgenol 162:561–567 Paranjpe DV, Bergin CJ (1994) Spiral CT of the lungs: optimal technique and resolution compared with conventional CT. Am J Roentgenol 162:561–567
14.
Zurück zum Zitat Coakley FV, Cohen MD, Johnson MS, Gonin R, Hanna MP (1998) Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT. Br J Radiol 71:135–140PubMed Coakley FV, Cohen MD, Johnson MS, Gonin R, Hanna MP (1998) Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT. Br J Radiol 71:135–140PubMed
15.
Zurück zum Zitat Eibel R, Turk TR, Kulinna C, Herrmann K, Reiser MF (2001) Multidetector-row CT of the lungs: multiplanar reconstructions and maximum intensity projections for the detection of pulmonary nodules. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:815–821CrossRefPubMed Eibel R, Turk TR, Kulinna C, Herrmann K, Reiser MF (2001) Multidetector-row CT of the lungs: multiplanar reconstructions and maximum intensity projections for the detection of pulmonary nodules. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:815–821CrossRefPubMed
16.
Zurück zum Zitat Gruden JF, Ouanounou S, Tigges S, Norris SD, Klausner TS (2002) Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT. Am J Roentgenol 179:149–157 Gruden JF, Ouanounou S, Tigges S, Norris SD, Klausner TS (2002) Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT. Am J Roentgenol 179:149–157
17.
Zurück zum Zitat Henschke CI, McCauley DI, Yankelevitz DF et al. (1999) Early lung cancer action project: overall design and findings from baseline screening. Lancet 354:99–105PubMed Henschke CI, McCauley DI, Yankelevitz DF et al. (1999) Early lung cancer action project: overall design and findings from baseline screening. Lancet 354:99–105PubMed
18.
Zurück zum Zitat Landis SH, Murray T, Bolden S, Wingo PA (1999) Cancer statistics. Cancer J Clin 49:8–31PubMed Landis SH, Murray T, Bolden S, Wingo PA (1999) Cancer statistics. Cancer J Clin 49:8–31PubMed
19.
Zurück zum Zitat Diederich S, Wormanns D, Semik M, Thomas M, Lenzen H, Roos N et al. (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773–781PubMed Diederich S, Wormanns D, Semik M, Thomas M, Lenzen H, Roos N et al. (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773–781PubMed
20.
Zurück zum Zitat Schoepf UJ, Becker CR, Obuchowski NA, Rust GF, Ohnesorge BM, Kohl G et al. (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease. Eur Radiol 11:1975–1985CrossRefPubMed Schoepf UJ, Becker CR, Obuchowski NA, Rust GF, Ohnesorge BM, Kohl G et al. (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease. Eur Radiol 11:1975–1985CrossRefPubMed
21.
Zurück zum Zitat Gurney JW (1993) Determining the likelihood of malignancy in solitary pulmonary nodules with Bayesian analysis. Part I. Theory. Radiology 186:405–413PubMed Gurney JW (1993) Determining the likelihood of malignancy in solitary pulmonary nodules with Bayesian analysis. Part I. Theory. Radiology 186:405–413PubMed
22.
Zurück zum Zitat Greene RE (1992) Missed lung nodules: lost opportunities for cancer cure. Radiology 182:8–9PubMed Greene RE (1992) Missed lung nodules: lost opportunities for cancer cure. Radiology 182:8–9PubMed
Metadaten
Titel
Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness
verfasst von
Frank Fischbach
Friedrich Knollmann
Volker Griesshaber
Torsten Freund
Ethem Akkol
Roland Felix
Publikationsdatum
01.10.2003
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 10/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1915-7

Weitere Artikel der Ausgabe 10/2003

European Radiology 10/2003 Zur Ausgabe

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.