Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 2/2009

01.02.2009 | Original Paper

Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT

verfasst von: Sanjay Doddamani, Michael J. Grushko, Amgad N. Makaryus, Vineet R. Jain, Ricardo Bello, Mark A. Friedman, Robert J. Ostfeld, Divya Malhotra, Lawrence M. Boxt, Linda Haramati, Daniel M. Spevack

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 2/2009

Einloggen, um Zugang zu erhalten

Abstract

Background Newer three-dimensional imaging technologies provide insight into cardiac shape and geometry from views previously unobtainable. Standard formulae like the continuity equation (CE) that rely on inherent assumptions about left ventricular outflow tract (LVOT) shape may need to be revisited. In the CE, small changes in LVOT diameter may significantly change calculated aortic valve area (AVA). Using 64-slice Multi-detector CT (MDCT), we performed LVOT planimetry to obviate the need for any geometric assumptions. Methods 64-slice MDCT was performed in 30 consecutive patients. The diameter-derived LVOT area (ALVOTdiam) was calculated from a view analogous to the 2D echo parasternal long axis. Direct planimetry of the LVOT (ALVOTplan) was performed just beneath the aortic valve in a plane perpendicular to the LVOT long axis. Further, assuming an ellipsoid outflow tract shape, LVOT area (ALVOTellip) was calculated using πab from the long and short diameters of the planimetered LVOT view. Eccentricity index (EI) was estimated by subtracting the ratio of shortest and longest LVOT diameters from one. Results ALVOTdiam always measured smaller than ALVOTplan (mean 3.7 ± 1.2 cm2 vs. 4.1 ± 1.3 cm2, respectively). The median EI was 0.18 (95% CI = 0.16–0.2; P = 0.0001). ALVOTellip more closely agreed with ALVOTplan (correlation = 0.96; P < 0.0001) than did ALVOTdiam (correlation = 0.87; P < 0.0001). Conclusion Using MDCT, the LVOT was shown to be elliptical in most patients. Applying the CE which assumes roundness of the LVOT consistently underestimated the LVOT area which may affect estimated AVA. Planimetry of the LVOT utilizing three-dimensional imaging modalities such as 3-D echocardiography, MRI, or MDCT may render a more precise AVA.
Literatur
1.
Zurück zum Zitat Zoghbi WA, Farmer KL, Soto JG, Nelson JG, Quinones MA (1986) Accurate noninvasive quantification of stenotic valve area by Doppler echocardiography. Circulation 73:452–459PubMed Zoghbi WA, Farmer KL, Soto JG, Nelson JG, Quinones MA (1986) Accurate noninvasive quantification of stenotic valve area by Doppler echocardiography. Circulation 73:452–459PubMed
2.
Zurück zum Zitat Teirstein P, Yeager M, Yock PG, Popp RL (1986) Doppler echocardiographic measurement of aortic valve area in aortic stenosis: a noninvasive application of the Gorlin formula. J Am Coll Cardiol 8:1059–1065PubMed Teirstein P, Yeager M, Yock PG, Popp RL (1986) Doppler echocardiographic measurement of aortic valve area in aortic stenosis: a noninvasive application of the Gorlin formula. J Am Coll Cardiol 8:1059–1065PubMed
5.
Zurück zum Zitat Otto CM (2004) Valvular stenosis. In: Otto CM (ed) Textbook of clinical echocardiography. Elsevier Saunders, Pennsylvania, pp 280–287 Otto CM (2004) Valvular stenosis. In: Otto CM (ed) Textbook of clinical echocardiography. Elsevier Saunders, Pennsylvania, pp 280–287
7.
Zurück zum Zitat Tanaka K, Makaryus AN, Wolff SD (2007) Correlation of aortic valve area obtained by the velocity-encoded phase contrast continuity method to direct planimetry using cardiovascular magnetic resonance. J Cardiovasc Magn Reson 9:799–805. doi:10.1080/10976640701545479 PubMedCrossRef Tanaka K, Makaryus AN, Wolff SD (2007) Correlation of aortic valve area obtained by the velocity-encoded phase contrast continuity method to direct planimetry using cardiovascular magnetic resonance. J Cardiovasc Magn Reson 9:799–805. doi:10.​1080/​1097664070154547​9 PubMedCrossRef
8.
Zurück zum Zitat Achenbach S, Ulzheimer S, Baum U et al (2000) Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102:2823–2828PubMed Achenbach S, Ulzheimer S, Baum U et al (2000) Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102:2823–2828PubMed
9.
10.
Zurück zum Zitat Garcia D, Dumesnil JG, Durand LG, Kadem L, Pibarot P (2003) Discrepancies between catheter and Doppler estimates of valve effective orifice area can be predicted from the pressure recovery phenomenon: practical implications with regard to quantification of aortic stenosis severity. J Am Coll Cardiol 41:435–442. doi:10.1016/S0735-1097(02)02764-X PubMedCrossRef Garcia D, Dumesnil JG, Durand LG, Kadem L, Pibarot P (2003) Discrepancies between catheter and Doppler estimates of valve effective orifice area can be predicted from the pressure recovery phenomenon: practical implications with regard to quantification of aortic stenosis severity. J Am Coll Cardiol 41:435–442. doi:10.​1016/​S0735-1097(02)02764-X PubMedCrossRef
11.
Zurück zum Zitat Wipperman CF, Schranz D, Stopfukuchen H, Huth R, Freund M, Jungst BK (1992) Evaluation of the valve area underestimation by the continuity equation. Cardiology 80:567–573CrossRef Wipperman CF, Schranz D, Stopfukuchen H, Huth R, Freund M, Jungst BK (1992) Evaluation of the valve area underestimation by the continuity equation. Cardiology 80:567–573CrossRef
12.
Zurück zum Zitat Oh JK, Taliercio CP, Holmes DR Jr (1988) Prediction of the severity of aortic stenosis by Doppler aortic valve area determination: prospective Doppler-catheterization correlation in 100 patients. J Am Coll Cardiol 11:1227–1234PubMedCrossRef Oh JK, Taliercio CP, Holmes DR Jr (1988) Prediction of the severity of aortic stenosis by Doppler aortic valve area determination: prospective Doppler-catheterization correlation in 100 patients. J Am Coll Cardiol 11:1227–1234PubMedCrossRef
13.
Zurück zum Zitat Spevack DM, Almuti K, Ostfeld R et al (2008) Routine adjustment of Doppler echocardiographically derived aortic valve area using a previously derived equation to account for the effect of pressure recovery. J Am Soc Echocardiogr 21(1):34–37PubMedCrossRef Spevack DM, Almuti K, Ostfeld R et al (2008) Routine adjustment of Doppler echocardiographically derived aortic valve area using a previously derived equation to account for the effect of pressure recovery. J Am Soc Echocardiogr 21(1):34–37PubMedCrossRef
15.
Zurück zum Zitat Tsujino H, Jones M, Shiota T et al (2001) Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract. Ultrasound Med Biol 27:69–74. doi:10.1016/S0301-5629(00)00270-2 PubMedCrossRef Tsujino H, Jones M, Shiota T et al (2001) Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract. Ultrasound Med Biol 27:69–74. doi:10.​1016/​S0301-5629(00)00270-2 PubMedCrossRef
16.
Zurück zum Zitat Menzel T, Mohr-Kahaly S, Wagner S, Fischer T, Bruckner A, Meyer J (1998) Calculation of left ventricular outflow tract area using three-dimensional echocardiography. Influence on quantification of aortic valve stenosis. Int J Card Imaging 14:373–379. doi:10.1023/A:1006045303442 PubMedCrossRef Menzel T, Mohr-Kahaly S, Wagner S, Fischer T, Bruckner A, Meyer J (1998) Calculation of left ventricular outflow tract area using three-dimensional echocardiography. Influence on quantification of aortic valve stenosis. Int J Card Imaging 14:373–379. doi:10.​1023/​A:​1006045303442 PubMedCrossRef
18.
Zurück zum Zitat Qui JX, Shiota T, Lever HM et al (2002) Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study. J Am Coll Cardiol 39:308–314 Qui JX, Shiota T, Lever HM et al (2002) Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study. J Am Coll Cardiol 39:308–314
19.
Zurück zum Zitat Yalcin F, Shiota T, Odbashian J et al (2000) Comparison by real-time three-dimensional echocardiography of left ventricular geometry in hypertrophic cardiomyopathy versus secondary left ventricular hypertrophy. J Am Coll Cardiol 85:1035–1038 Yalcin F, Shiota T, Odbashian J et al (2000) Comparison by real-time three-dimensional echocardiography of left ventricular geometry in hypertrophic cardiomyopathy versus secondary left ventricular hypertrophy. J Am Coll Cardiol 85:1035–1038
21.
22.
Zurück zum Zitat Herzog C, Arning-Erb M, Zangos S, Eichler K, Hammerstingl R, Dogan S et al (2006) Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology 238(1):75–86. doi:10.1148/radiol.2381041595 PubMedCrossRef Herzog C, Arning-Erb M, Zangos S, Eichler K, Hammerstingl R, Dogan S et al (2006) Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology 238(1):75–86. doi:10.​1148/​radiol.​2381041595 PubMedCrossRef
Metadaten
Titel
Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT
verfasst von
Sanjay Doddamani
Michael J. Grushko
Amgad N. Makaryus
Vineet R. Jain
Ricardo Bello
Mark A. Friedman
Robert J. Ostfeld
Divya Malhotra
Lawrence M. Boxt
Linda Haramati
Daniel M. Spevack
Publikationsdatum
01.02.2009
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 2/2009
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-008-9362-9

Weitere Artikel der Ausgabe 2/2009

The International Journal of Cardiovascular Imaging 2/2009 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.