Abstract

We wanted to compare the image quality and radiation dose of retrospective versus prospective ECG-gated dual-source CT imaging in pediatric patients with congenital heart diseases. We retrospectively evaluated 44 thorax CT images that were obtained using two different protocols (retrospective helical ECG-gated [n = 22] versus prospective non-helical ECG-triggering [n = 22]) in patients younger than 5 years. Two radiologists evaluated the image quality, using a 3- or 4-point scale, in terms of the degree of homogeneity of vascular enhancement, the stair-step artifacts, the subjective image noise and the overall subjective image quality. We compared the mean score of image quality, the frequency of marked stair-step artifact and the estimated radiation dose. The mean score of the homogeneity of vascular enhancement and the stair-step artifacts tended to be higher for the patients in the retrospective group than that for the patients in the prospective group, but this did not reach statistical significance. However, marked stair-step artifacts were significantly more frequent in the prospective scan group than that in the retrospective scan group (25.8 vs. 7.6%, respectively, P < 0.01). The mean scores for subjective image noise and the overall image quality were better in the retrospective group than those scores in the prospective group (P < 0.01). The mean estimated effective dose was higher for the retrospective ECG-gated helical scan than that for the prospective non-helical scan (0.79 vs. 0.21 mSv, respectively, P < 0.01). Retrospective ECG-gated helical dual-source CT using aggressive ECG pulsing can be obtained with an acceptable radiation dose and superior image quality, as compared to the prospective ECG-triggering technique, for the evaluation of congenital heart diseases in pediatric patients who are younger than 5 years old.
Literatur
1.
Zurück zum Zitat Hayabuchi Y, Mori K, Kitagawa T et al (2007) Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography. Am Heart J 154(4):783–788CrossRefPubMed Hayabuchi Y, Mori K, Kitagawa T et al (2007) Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography. Am Heart J 154(4):783–788CrossRefPubMed
2.
Zurück zum Zitat Goo HW, Park IS, Ko JK et al (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J Cardiovasc Imaging 21(2–3):347–365CrossRefPubMed Goo HW, Park IS, Ko JK et al (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J Cardiovasc Imaging 21(2–3):347–365CrossRefPubMed
3.
Zurück zum Zitat Greil GF, Schoebinger M, Kuettner A et al (2006) Imaging of aortopulmonary collateral arteries with high-resolution multidetector CT. Pediatr Radiol 36(6):502–509CrossRefPubMed Greil GF, Schoebinger M, Kuettner A et al (2006) Imaging of aortopulmonary collateral arteries with high-resolution multidetector CT. Pediatr Radiol 36(6):502–509CrossRefPubMed
4.
Zurück zum Zitat Oztunc F, Baris S, Adaletli I et al (2009) Coronary events and anatomy after arterial switch operation for transposition of the great arteries: detection by 16-row multislice computed tomography angiography in pediatric patients. Cardiovasc Intervent Radiol 32(2):206–212CrossRefPubMed Oztunc F, Baris S, Adaletli I et al (2009) Coronary events and anatomy after arterial switch operation for transposition of the great arteries: detection by 16-row multislice computed tomography angiography in pediatric patients. Cardiovasc Intervent Radiol 32(2):206–212CrossRefPubMed
5.
Zurück zum Zitat Wang XM, Wu LB, Sun C et al (2007) Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot. Eur J Radiol 64(2):296–301CrossRefPubMed Wang XM, Wu LB, Sun C et al (2007) Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot. Eur J Radiol 64(2):296–301CrossRefPubMed
6.
Zurück zum Zitat Hollingsworth CL, Yoshizumi TT, Frush DP et al (2007) Pediatric cardiac-gated CT angiography: assessment of radiation dose. Am J Roentgenol 189(1):12–18CrossRef Hollingsworth CL, Yoshizumi TT, Frush DP et al (2007) Pediatric cardiac-gated CT angiography: assessment of radiation dose. Am J Roentgenol 189(1):12–18CrossRef
7.
Zurück zum Zitat Hein F, Meyer T, Hadamitzky M et al (2009) Prospective ECG-triggered sequential scan protocol for coronary dual-source CT angiography: initial experience. Int J Cardiovasc Imaging 25(suppl 2):S231–S239CrossRef Hein F, Meyer T, Hadamitzky M et al (2009) Prospective ECG-triggered sequential scan protocol for coronary dual-source CT angiography: initial experience. Int J Cardiovasc Imaging 25(suppl 2):S231–S239CrossRef
8.
Zurück zum Zitat Petersilka M, Bruder H, Krauss B et al (2008) Technical principles of dual source CT. Eur J Radiol 68(3):362–368CrossRefPubMed Petersilka M, Bruder H, Krauss B et al (2008) Technical principles of dual source CT. Eur J Radiol 68(3):362–368CrossRefPubMed
9.
Zurück zum Zitat Stolzmann P, Scheffel H, Schertler T et al (2008) Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18(3):592–599CrossRefPubMed Stolzmann P, Scheffel H, Schertler T et al (2008) Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18(3):592–599CrossRefPubMed
11.
Zurück zum Zitat Ben Saad M, Rohnean A, Sigal-Cinqualbre A et al (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39(7):668–676CrossRefPubMed Ben Saad M, Rohnean A, Sigal-Cinqualbre A et al (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39(7):668–676CrossRefPubMed
12.
Zurück zum Zitat Kuettner A, Gehann B, Spolnik J et al (2009) Strategies for dose-optimized imaging in pediatric cardiac dual source CT. Rofo 181(4):339–348PubMed Kuettner A, Gehann B, Spolnik J et al (2009) Strategies for dose-optimized imaging in pediatric cardiac dual source CT. Rofo 181(4):339–348PubMed
13.
Zurück zum Zitat Lerner CB, Frush DP, Boll DT (2008) Evaluation of a coronary-cameral fistula: benefits of coronary dual-source MDCT angiography in children. Pediatr Radiol 38(8):874–878CrossRefPubMed Lerner CB, Frush DP, Boll DT (2008) Evaluation of a coronary-cameral fistula: benefits of coronary dual-source MDCT angiography in children. Pediatr Radiol 38(8):874–878CrossRefPubMed
14.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRefPubMed
15.
Zurück zum Zitat Cademartiri F, Mollet NR, Runza G et al (2006) Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing. Am J Roentgenol 186(3):634–638CrossRef Cademartiri F, Mollet NR, Runza G et al (2006) Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing. Am J Roentgenol 186(3):634–638CrossRef
16.
Zurück zum Zitat Hirai N, Horiguchi J, Fujioka C et al (2008) Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 248(2):424–430CrossRefPubMed Hirai N, Horiguchi J, Fujioka C et al (2008) Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 248(2):424–430CrossRefPubMed
17.
Zurück zum Zitat Arnoldi E, Johnson TR, Rist C et al (2009) Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques. Eur Radiol 19(9):2147–2155CrossRefPubMed Arnoldi E, Johnson TR, Rist C et al (2009) Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques. Eur Radiol 19(9):2147–2155CrossRefPubMed
18.
Zurück zum Zitat Stolzmann P, Leschka S, Scheffel H et al (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249(1):71–80CrossRefPubMed Stolzmann P, Leschka S, Scheffel H et al (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249(1):71–80CrossRefPubMed
19.
Zurück zum Zitat McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243(3):775–784CrossRefPubMed McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243(3):775–784CrossRefPubMed
20.
Zurück zum Zitat Herzog C, Mulvihill DM, Nguyen SA et al (2008) Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. Am J Roentgenol 190(5):1232–1240CrossRef Herzog C, Mulvihill DM, Nguyen SA et al (2008) Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. Am J Roentgenol 190(5):1232–1240CrossRef
21.
Zurück zum Zitat Pages J, Buls N, Osteaux M (2003) CT doses in children: a multicentre study. Br J Radiol 76(911):803–811CrossRefPubMed Pages J, Buls N, Osteaux M (2003) CT doses in children: a multicentre study. Br J Radiol 76(911):803–811CrossRefPubMed
22.
Zurück zum Zitat Poll LW, Cohnen M, Brachten S et al (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (“ECG pulsing”): phantom measurements. Rofo 174(12):1500–1505PubMed Poll LW, Cohnen M, Brachten S et al (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (“ECG pulsing”): phantom measurements. Rofo 174(12):1500–1505PubMed
Metadaten
Titel
Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose
verfasst von
Kwang Nam Jin
Eun-Ah Park
Cheong-il Shin
Whal Lee
Jin Wook Chung
Jae Hyung Park
Publikationsdatum
01.02.2010
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe Sonderheft 1/2010
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-009-9579-2

Weitere Artikel der Sonderheft 1/2010

The International Journal of Cardiovascular Imaging 1/2010 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.