Increased rate of observed real-time pulmonary vein isolation with third-generation short-tip cryoballoon

verfasst von: Alexander Pott, Kerstin Petscher, Marvin Messemer, Wolfgang Rottbauer, Tillman Dahme

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 3/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Pulmonary vein isolation (PVI) with the cryoballoon is an established treatment for symptomatic atrial fibrillation. The second-generation cryoballoon increased efficacy in comparison to the first-generation cryoballoon. The third-generation cryoballoon was designed with a shorter distal tip to facilitate real-time recording of pulmonary vein (PV) isolation. Here, we compared the rate of real-time recordings of PVI of the second- and third-generation cryoballoon.

Methods

The incidence of real-time recording of PV isolation and time to PV isolation of the first 37 patients treated with the new third-generation cryoballoon at our center were compared to the last 37 patients treated with the second-generation cryoballoon.

Results

One hundred forty-nine pulmonary veins (PVs) were identified in each group. All PVs were isolated successfully with the second- or third-generation cryoballoon. Real-time registration of PVI occurred in 83 PVs (55.7 %) with the second-generation cryoballoon and in 124 PVs (83.2 %) with the third-generation cryoballoon (p < 0.001). The rate of observed real-time PVI was significantly higher with the third-generation cryoballoon for each individual PV. The time-to-isolation was 44 ± 25 s with the second-generation cryoballoon vs. 42 ± 22 s with the third-generation cryoballoon (p = 0.25). In a short-term clinical follow-up, there was no significant difference in atrial arrhythmia recurrence rates between both groups.

Conclusions

The third-generation cryoballoon facilitates real-time recording of PV isolation with significantly higher rates of observed time-to-isolation. The time to PV isolation is not different between second- and third-generation cryoballoon.
Literatur
1.
Zurück zum Zitat Kuck KH, Brugada J, Furnkranz A, Metzner A, Ouyang F, Chun KR et al. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N Engl J Med 2016;374(23):2235–45. Kuck KH, Brugada J, Furnkranz A, Metzner A, Ouyang F, Chun KR et al. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N Engl J Med 2016;374(23):2235–45.
2.
Zurück zum Zitat Luik A, Radzewitz A, Kieser M, Walter M, Bramlage P, Hormann P, et al. Cryoballoon versus open irrigated radiofrequency ablation in patients with paroxysmal atrial fibrillation: The prospective, randomized, controlled, noninferiority freezeAF study. Circulation. 2015;132(14):1311–9.CrossRefPubMedPubMedCentral Luik A, Radzewitz A, Kieser M, Walter M, Bramlage P, Hormann P, et al. Cryoballoon versus open irrigated radiofrequency ablation in patients with paroxysmal atrial fibrillation: The prospective, randomized, controlled, noninferiority freezeAF study. Circulation. 2015;132(14):1311–9.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG, et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. J Am Coll Cardiol. 2013;61(16):1713–23.CrossRefPubMed Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG, et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. J Am Coll Cardiol. 2013;61(16):1713–23.CrossRefPubMed
4.
Zurück zum Zitat Aryana A, Morkoch S, Bailey S, Lim HW, Sara R, d’Avila A, et al. Acute procedural and cryoballoon characteristics from cryoablation of atrial fibrillation using the first- and second-generation cryoballoon: a retrospective comparative study with follow-up outcomes. J Interv Card Electrophysiol. 2014;41(2):177–86.CrossRefPubMed Aryana A, Morkoch S, Bailey S, Lim HW, Sara R, d’Avila A, et al. Acute procedural and cryoballoon characteristics from cryoablation of atrial fibrillation using the first- and second-generation cryoballoon: a retrospective comparative study with follow-up outcomes. J Interv Card Electrophysiol. 2014;41(2):177–86.CrossRefPubMed
5.
Zurück zum Zitat Aytemir K, Gurses KM, Yalcin MU, Kocyigit D, Dural M, Evranos B, et al. Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoondagger. Europace. 2015;17(3):379–87.CrossRefPubMed Aytemir K, Gurses KM, Yalcin MU, Kocyigit D, Dural M, Evranos B, et al. Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoondagger. Europace. 2015;17(3):379–87.CrossRefPubMed
6.
Zurück zum Zitat Chierchia GB, Di Giovanni G, Ciconte G, de Asmundis C, Conte G, Sieira-Moret J, et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace. 2014;16(5):639–44.CrossRefPubMed Chierchia GB, Di Giovanni G, Ciconte G, de Asmundis C, Conte G, Sieira-Moret J, et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace. 2014;16(5):639–44.CrossRefPubMed
7.
Zurück zum Zitat Di Giovanni G, Wauters K, Chierchia GB, Sieira J, Levinstein M, Conte G, et al. One-year follow-up after single procedure Cryoballoon ablation: a comparison between the first and second generation balloon. J Cardiovasc Electrophysiol. 2014;25(8):834–9.CrossRefPubMed Di Giovanni G, Wauters K, Chierchia GB, Sieira J, Levinstein M, Conte G, et al. One-year follow-up after single procedure Cryoballoon ablation: a comparison between the first and second generation balloon. J Cardiovasc Electrophysiol. 2014;25(8):834–9.CrossRefPubMed
8.
Zurück zum Zitat Furnkranz A, Bordignon S, Dugo D, Perotta L, Gunawardene M, Schulte-Hahn B, et al. Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 2014;25(8):840–4.CrossRefPubMed Furnkranz A, Bordignon S, Dugo D, Perotta L, Gunawardene M, Schulte-Hahn B, et al. Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 2014;25(8):840–4.CrossRefPubMed
9.
Zurück zum Zitat Jourda F, Providencia R, Marijon E, Bouzeman A, Hireche H, Khoueiry Z, et al. Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation-a prospective evaluation. Europace. 2015;17(2):225–31.CrossRefPubMed Jourda F, Providencia R, Marijon E, Bouzeman A, Hireche H, Khoueiry Z, et al. Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation-a prospective evaluation. Europace. 2015;17(2):225–31.CrossRefPubMed
10.
Zurück zum Zitat Metzner A, Reissmann B, Rausch P, Mathew S, Wohlmuth P, Tilz R, et al. One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circ Arrhythm Electrophysiol. 2014;7(2):288–92.CrossRefPubMed Metzner A, Reissmann B, Rausch P, Mathew S, Wohlmuth P, Tilz R, et al. One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circ Arrhythm Electrophysiol. 2014;7(2):288–92.CrossRefPubMed
11.
Zurück zum Zitat Pandya B, Sheikh A, Spagnola J, Bekheit S, Lafferty J, Kowalski M. Safety and efficacy of second-generation versus first-generation cryoballoons for treatment of atrial fibrillation: a meta-analysis of current evidence. J Interv Card Electrophysiol. 2016;45(1):49–56.CrossRefPubMed Pandya B, Sheikh A, Spagnola J, Bekheit S, Lafferty J, Kowalski M. Safety and efficacy of second-generation versus first-generation cryoballoons for treatment of atrial fibrillation: a meta-analysis of current evidence. J Interv Card Electrophysiol. 2016;45(1):49–56.CrossRefPubMed
12.
Zurück zum Zitat Aryana A, Mugnai G, Singh SM, Pujara DK, de Asmundis C, Singh SK, et al. Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation. Heart Rhythm. 2016;13(2):424–32.CrossRefPubMed Aryana A, Mugnai G, Singh SM, Pujara DK, de Asmundis C, Singh SK, et al. Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation. Heart Rhythm. 2016;13(2):424–32.CrossRefPubMed
13.
Zurück zum Zitat Ciconte G, Mugnai G, Sieira J, Velagic V, Saitoh Y, Irfan G, et al. On the quest for the best freeze: predictors of late pulmonary vein reconnections after second-generation cryoballoon ablation. Circ Arrhythm Electrophysiol. 2015;8(6):1359–65.PubMed Ciconte G, Mugnai G, Sieira J, Velagic V, Saitoh Y, Irfan G, et al. On the quest for the best freeze: predictors of late pulmonary vein reconnections after second-generation cryoballoon ablation. Circ Arrhythm Electrophysiol. 2015;8(6):1359–65.PubMed
14.
Zurück zum Zitat Ciconte G, Velagic V, Mugnai G, Saitoh Y, Irfan G, Hunuk B, et al. Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures. Europace. 2016;18(1):71–7.CrossRefPubMed Ciconte G, Velagic V, Mugnai G, Saitoh Y, Irfan G, Hunuk B, et al. Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures. Europace. 2016;18(1):71–7.CrossRefPubMed
15.
Zurück zum Zitat Lakhani M, Saiful F, Parikh V, Goyal N, Bekheit S, Kowalski M. Recordings of diaphragmatic electromyograms during cryoballoon ablation for atrial fibrillation accurately predict phrenic nerve injury. Heart Rhythm. 2014;11(3):369–74.CrossRefPubMed Lakhani M, Saiful F, Parikh V, Goyal N, Bekheit S, Kowalski M. Recordings of diaphragmatic electromyograms during cryoballoon ablation for atrial fibrillation accurately predict phrenic nerve injury. Heart Rhythm. 2014;11(3):369–74.CrossRefPubMed
16.
Zurück zum Zitat Mondesert B, Andrade JG, Khairy P, Guerra PG, Dyrda K, Macle L, et al. Clinical experience with a novel electromyographic approach to preventing phrenic nerve injury during cryoballoon ablation in atrial fibrillation. Circ Arrhythm Electrophysiol. 2014;7(4):605–11.CrossRefPubMed Mondesert B, Andrade JG, Khairy P, Guerra PG, Dyrda K, Macle L, et al. Clinical experience with a novel electromyographic approach to preventing phrenic nerve injury during cryoballoon ablation in atrial fibrillation. Circ Arrhythm Electrophysiol. 2014;7(4):605–11.CrossRefPubMed
17.
Zurück zum Zitat Furnkranz A, Bologna F, Bordignon S, Perrotta L, Dugo D, Schmidt B, Chun JK. Procedural characteristics of pulmonary vein isolation using the novel third-generation cryoballoon. Europace. 2016, [Epub ahead of print]. Furnkranz A, Bologna F, Bordignon S, Perrotta L, Dugo D, Schmidt B, Chun JK. Procedural characteristics of pulmonary vein isolation using the novel third-generation cryoballoon. Europace. 2016, [Epub ahead of print].
18.
Zurück zum Zitat Heeger CH, Wissner E, Mathew S, Hayashi K, Sohns C, Reissmann B et al. Short tip-big difference? First-in-man experience and procedural efficacy of pulmonary vein isolation using the third-generation cryoballoon. Clin Res Cardiol. 2015;105(6):482–8. Heeger CH, Wissner E, Mathew S, Hayashi K, Sohns C, Reissmann B et al. Short tip-big difference? First-in-man experience and procedural efficacy of pulmonary vein isolation using the third-generation cryoballoon. Clin Res Cardiol. 2015;105(6):482–8.
19.
Zurück zum Zitat Mugnai G, de Asmundis C, Hunuk B, Stroker E, Moran D, Hacioglu E et al. Improved visualisation of real-time recordings during third generation cryoballoon ablation: a comparison between the novel short-tip and the second generation device. J Interv Card Electrophysiol. 2016, [Epub ahead of print]. Mugnai G, de Asmundis C, Hunuk B, Stroker E, Moran D, Hacioglu E et al. Improved visualisation of real-time recordings during third generation cryoballoon ablation: a comparison between the novel short-tip and the second generation device. J Interv Card Electrophysiol. 2016, [Epub ahead of print].
Metadaten
Titel
Increased rate of observed real-time pulmonary vein isolation with third-generation short-tip cryoballoon
verfasst von
Alexander Pott
Kerstin Petscher
Marvin Messemer
Wolfgang Rottbauer
Tillman Dahme
Publikationsdatum
23.07.2016
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 3/2016
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-016-0160-3

Weitere Artikel der Ausgabe 3/2016

Journal of Interventional Cardiac Electrophysiology 3/2016 Zur Ausgabe

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Semaglutid bei Herzinsuffizienz: Wie erklärt sich die Wirksamkeit?

17.05.2024 Herzinsuffizienz Nachrichten

Bei adipösen Patienten mit Herzinsuffizienz des HFpEF-Phänotyps ist Semaglutid von symptomatischem Nutzen. Resultiert dieser Benefit allein aus der Gewichtsreduktion oder auch aus spezifischen Effekten auf die Herzinsuffizienz-Pathogenese? Eine neue Analyse gibt Aufschluss.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.