Skip to main content
Erschienen in: Journal of Medical Systems 1/2011

01.02.2011 | Original Paper

Single Image Signal-to-Noise Ratio Estimation for Magnetic Resonance Images

verfasst von: K. S. Sim, M. A. Lai, C. P. Tso, C. C. Teo

Erschienen in: Journal of Medical Systems | Ausgabe 1/2011

Einloggen, um Zugang zu erhalten

Abstract

A novel technique to quantify the signal-to-noise ratio (SNR) of magnetic resonance images is developed. The image SNR is quantified by estimating the amplitude of the signal spectrum using the autocorrelation function of just one single magnetic resonance image. To test the performance of the quantification, SNR measurement data are fitted to theoretically expected curves. It is shown that the technique can be implemented in a highly efficient way for the magnetic resonance imaging system.
Literatur
1.
Zurück zum Zitat Magnotta, V. A., Friedman, L., and Birn, F., Measurement of signal-to-noise and contrast-to-noise in the fBIRN multicenter imaging study. J. Digit. Imaging. 19 (2)140–147, 2006.CrossRef Magnotta, V. A., Friedman, L., and Birn, F., Measurement of signal-to-noise and contrast-to-noise in the fBIRN multicenter imaging study. J. Digit. Imaging. 19 (2)140–147, 2006.CrossRef
2.
Zurück zum Zitat Boone, J. M., Radiological interpretation, toward quantitative image assessment. Med. Phys. 34 (11)4173–4179, 2007.CrossRef Boone, J. M., Radiological interpretation, toward quantitative image assessment. Med. Phys. 34 (11)4173–4179, 2007.CrossRef
3.
Zurück zum Zitat Dietrich, O., Raya, J. G., Reeder, S. B., Ingrisch, M., Reiser, M. F., and Schoenberg, S. O., Influence of multi-channel combination, parallel imaging, and other reconstruction techniques on MRI noise characteristics. Magn. Reson. Imaging. 26:754–762, 2008.CrossRef Dietrich, O., Raya, J. G., Reeder, S. B., Ingrisch, M., Reiser, M. F., and Schoenberg, S. O., Influence of multi-channel combination, parallel imaging, and other reconstruction techniques on MRI noise characteristics. Magn. Reson. Imaging. 26:754–762, 2008.CrossRef
4.
Zurück zum Zitat Prince, J. L., and Links, J. M., Medical imaging signals and system. Pearson Prentice Hall, New Jersey, 2006. Prince, J. L., and Links, J. M., Medical imaging signals and system. Pearson Prentice Hall, New Jersey, 2006.
5.
Zurück zum Zitat Wieczorek, H., and Goedicke, A., Analytical model for SPECT detector concepts. IEEE Trans. Nucl. Sci. 53 (3)1102–1112, 2006.CrossRef Wieczorek, H., and Goedicke, A., Analytical model for SPECT detector concepts. IEEE Trans. Nucl. Sci. 53 (3)1102–1112, 2006.CrossRef
6.
Zurück zum Zitat Gravier, E., Yang, Y. Y., and Jin, M. W., Tomographic reconstruction of dynamic cardiac image sequences. IEEE Trans. Image Processing. 16 (4)932–942, 2007.CrossRefMathSciNet Gravier, E., Yang, Y. Y., and Jin, M. W., Tomographic reconstruction of dynamic cardiac image sequences. IEEE Trans. Image Processing. 16 (4)932–942, 2007.CrossRefMathSciNet
7.
Zurück zum Zitat Wang, Y., and Lei, T., Statistical analysis of MR imaging and its applications in image modelling. Proc IEEE Int Conf Image Proc Neural Networks. I:866–870, 1994. Wang, Y., and Lei, T., Statistical analysis of MR imaging and its applications in image modelling. Proc IEEE Int Conf Image Proc Neural Networks. I:866–870, 1994.
8.
Zurück zum Zitat Brooks, J. C. W., Beckmann, C. F., Miller, K. L., Wise, R. G., Porro, C. A., Tracey, I., and Jenkinson, M., Physiological noise modelling for spinal functional magnetic resonance imaging studies. Neuroimage. 39 (2)680–692, 2008.CrossRef Brooks, J. C. W., Beckmann, C. F., Miller, K. L., Wise, R. G., Porro, C. A., Tracey, I., and Jenkinson, M., Physiological noise modelling for spinal functional magnetic resonance imaging studies. Neuroimage. 39 (2)680–692, 2008.CrossRef
9.
Zurück zum Zitat Sijbers, J., den Dekker, A. J., Raman, E., and Van Dyck, D., Parameter estimation from magnitude MR images. Int. J. Imaging Syst. Technol. 10 (2)109–114, 1999.CrossRef Sijbers, J., den Dekker, A. J., Raman, E., and Van Dyck, D., Parameter estimation from magnitude MR images. Int. J. Imaging Syst. Technol. 10 (2)109–114, 1999.CrossRef
10.
Zurück zum Zitat Sano, R. M., Performance standard for clinical magnetic resonance systems. In: Dixon, R. L. (Ed.), MRI: Acceptance Testing and Quality Control—The Role of the Clinical Medical Physicist Medical Physics, Madison, pp. 185–189, 1988. Sano, R. M., Performance standard for clinical magnetic resonance systems. In: Dixon, R. L. (Ed.), MRI: Acceptance Testing and Quality Control—The Role of the Clinical Medical Physicist Medical Physics, Madison, pp. 185–189, 1988.
11.
Zurück zum Zitat Murphy, B. W., Carson, P. L., Ellis, J. H., Zhang, Y. T., Hyde, R. J., and Chenevert, T. L., Signal-to-noise measures for magnetic resonance imagers. Magn. Reson. Imaging. 11:425–428, 1993.CrossRef Murphy, B. W., Carson, P. L., Ellis, J. H., Zhang, Y. T., Hyde, R. J., and Chenevert, T. L., Signal-to-noise measures for magnetic resonance imagers. Magn. Reson. Imaging. 11:425–428, 1993.CrossRef
12.
Zurück zum Zitat Kaufman, L., Kramer, D. M., Crooks, L. E., and Ortendahl, D. A., Measuring signal-to-noise ratios in MR imaging. Radiology. 173:265–267, 1989. Kaufman, L., Kramer, D. M., Crooks, L. E., and Ortendahl, D. A., Measuring signal-to-noise ratios in MR imaging. Radiology. 173:265–267, 1989.
13.
Zurück zum Zitat Henkelman, R. M., Measurement of signal intensities in the presence of noise in MR images. Med. Phys. 12 (2)232–233, 1985.CrossRef Henkelman, R. M., Measurement of signal intensities in the presence of noise in MR images. Med. Phys. 12 (2)232–233, 1985.CrossRef
14.
Zurück zum Zitat Lenz, F., Electron microscopy in materials science. Academic, London, 1971. Lenz, F., Electron microscopy in materials science. Academic, London, 1971.
15.
Zurück zum Zitat Frank, J., and Al-Ali, L., Signal-to-noise ratio of electron micrographs obtained by cross correlation. Nature. 256:376–379, 1975.CrossRef Frank, J., and Al-Ali, L., Signal-to-noise ratio of electron micrographs obtained by cross correlation. Nature. 256:376–379, 1975.CrossRef
16.
Zurück zum Zitat Reimer, L., Scanning electron microscopy: physics of image formation and microanalysis. Springer, Berlin, 1998. Reimer, L., Scanning electron microscopy: physics of image formation and microanalysis. Springer, Berlin, 1998.
17.
Zurück zum Zitat Sijbers, J., Scheunders, P., Bonnet, N., Van Dyck, D., and Raman, E., Quantification and improvement of the signal-to-noise ratio in a magnetic resonance image acquisition procedure. Magn. Reson. Imaging. 14 (10)1157–1163, 1996.CrossRef Sijbers, J., Scheunders, P., Bonnet, N., Van Dyck, D., and Raman, E., Quantification and improvement of the signal-to-noise ratio in a magnetic resonance image acquisition procedure. Magn. Reson. Imaging. 14 (10)1157–1163, 1996.CrossRef
18.
Zurück zum Zitat Sim, K. S., Chuah, H. T., and Zheng, C., Performance of a mixed Lagrange time delay estimation autoregressive (MLTDEAR) model for single-image signal-to-noise ratio estimation in scanning electron microscopy. J. Microsc. 219 (1)1–17, 2005.CrossRefMathSciNet Sim, K. S., Chuah, H. T., and Zheng, C., Performance of a mixed Lagrange time delay estimation autoregressive (MLTDEAR) model for single-image signal-to-noise ratio estimation in scanning electron microscopy. J. Microsc. 219 (1)1–17, 2005.CrossRefMathSciNet
19.
Zurück zum Zitat Frank, J., A practical resolution criterion in optics and electron microscopy. Optik. 43 (1)25–34, 1975. Frank, J., A practical resolution criterion in optics and electron microscopy. Optik. 43 (1)25–34, 1975.
Metadaten
Titel
Single Image Signal-to-Noise Ratio Estimation for Magnetic Resonance Images
verfasst von
K. S. Sim
M. A. Lai
C. P. Tso
C. C. Teo
Publikationsdatum
01.02.2011
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 1/2011
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-009-9339-9

Weitere Artikel der Ausgabe 1/2011

Journal of Medical Systems 1/2011 Zur Ausgabe