Skip to main content
Erschienen in: Endocrine 1/2013

01.02.2013 | Review

Continuous glucose monitoring in type 1 diabetes

verfasst von: Nelly Mauras, Larry Fox, Kimberly Englert, Roy W. Beck

Erschienen in: Endocrine | Ausgabe 1/2013

Einloggen, um Zugang zu erhalten

Abstract

Continuous glucose monitors (CGM), devices that can measure interstitial glucose in “real time,” have become widely available particularly for use in patients with diabetes, and their accuracy and ease of use have greatly improved over the last decade. A number of large and well-controlled clinical trials have firmly established their usefulness in improving metabolic control (as measured by HbA1C) and decreasing time spent in hypoglycemia in adults; however, data have been less robust proving benefit in children and adolescents. Benefits are clearly linked to near-continuous wear. Insulin dosing algorithms based on CGM glucose trends have proven useful in dissecting the large volume of data generated daily by these devices, although these are imperfect tools, particularly in children. The technology is likely to be most useful when integrated with insulin pump delivery systems (sensor augmented). In this review, we concentrate on the analysis of published results of the largest trials in adults and children, including the very young, with diabetes.
Literatur
1.
Zurück zum Zitat S.A. Weinzimer, R.W. Beck, H.P. Chase, L.A. Fox, B.A. Buckingham, W.V. Tamborlane, C. Kollman, J. Coffey, D. Xing, K.J. Ruedy, Diabetes Research in Children Network Study Group, Accuracy of newer-generation home blood glucose meters in a diabetes research in children network (DirecNet) inpatient exercise study. Diabetes Technol. Ther. 7, 675–680 (2005)PubMedCrossRef S.A. Weinzimer, R.W. Beck, H.P. Chase, L.A. Fox, B.A. Buckingham, W.V. Tamborlane, C. Kollman, J. Coffey, D. Xing, K.J. Ruedy, Diabetes Research in Children Network Study Group, Accuracy of newer-generation home blood glucose meters in a diabetes research in children network (DirecNet) inpatient exercise study. Diabetes Technol. Ther. 7, 675–680 (2005)PubMedCrossRef
2.
Zurück zum Zitat J.C. Pickup, S.C. Freeman, A.J. Sutton, Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data. BMJ 343, d3805 (2011)PubMedCrossRef J.C. Pickup, S.C. Freeman, A.J. Sutton, Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data. BMJ 343, d3805 (2011)PubMedCrossRef
3.
Zurück zum Zitat M. Phillip, T. Danne, S. Shalitin, B. Buckingham, L. Laffel, W. Tamborlane, T. Battelino, for the Consensus Forum Participants, Use of continuous glucose monitoring in children and adolescents. Pediatr. Diabetes 13, 215–228 (2012)PubMedCrossRef M. Phillip, T. Danne, S. Shalitin, B. Buckingham, L. Laffel, W. Tamborlane, T. Battelino, for the Consensus Forum Participants, Use of continuous glucose monitoring in children and adolescents. Pediatr. Diabetes 13, 215–228 (2012)PubMedCrossRef
4.
Zurück zum Zitat D.C. Klonoff, B. Buckingham, J.S. Christiansen, V.M. Montori, W.V. Tamborlane, R.A. Vigersky, H. Wolpert, Continuous glucose monitoring: an endocrine society clinical practice guideline. J. Clin. Endocrinol. Metab. 96, 2968–2979 (2011)PubMedCrossRef D.C. Klonoff, B. Buckingham, J.S. Christiansen, V.M. Montori, W.V. Tamborlane, R.A. Vigersky, H. Wolpert, Continuous glucose monitoring: an endocrine society clinical practice guideline. J. Clin. Endocrinol. Metab. 96, 2968–2979 (2011)PubMedCrossRef
5.
Zurück zum Zitat Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, W.V. Tamborlane, R.W. Beck, B.W. Bode, B. Buckingham, H.P. Chase, R. Clemons, R. Fiallo-Scharer, L.A. Fox, L.K. Gilliam, I.B. Hirsch, E.S. Huang, C. Kollman, A.J. Kowalski, L. Laffel, J.M. Lawrence, J. Lee, N. Mauras, M. O’Grady, K.J. Ruedy, M. Tansey, E. Tsalikian, S. Weinzimer, D.M. Wilson, H. Wolpert, T. Wysocki, D. Xing, Continuous glucose monitoring and intensive treatment of type 1 diabetes. N. Engl. J. Med. 359, 1464–1476 (2008)PubMedCrossRef Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, W.V. Tamborlane, R.W. Beck, B.W. Bode, B. Buckingham, H.P. Chase, R. Clemons, R. Fiallo-Scharer, L.A. Fox, L.K. Gilliam, I.B. Hirsch, E.S. Huang, C. Kollman, A.J. Kowalski, L. Laffel, J.M. Lawrence, J. Lee, N. Mauras, M. O’Grady, K.J. Ruedy, M. Tansey, E. Tsalikian, S. Weinzimer, D.M. Wilson, H. Wolpert, T. Wysocki, D. Xing, Continuous glucose monitoring and intensive treatment of type 1 diabetes. N. Engl. J. Med. 359, 1464–1476 (2008)PubMedCrossRef
6.
Zurück zum Zitat Diabetes Research In Children Network (DirecNet) Study Group, B. Buckingham, D. Xing, S. Weinzimer, R. Fiallo-Scharer, C. Kollman, N. Mauras, E. Tsalikian, W. Tamborlane, R. Wysocki, K. Ruedy, R. Beck, Use of the DirecNet applied treatment algorithm (data) for diabetes management with a real-time continuous glucose monitor (the freestyle navigator). Pediatr. Diabetes 9, 142–147 (2008)PubMedCrossRef Diabetes Research In Children Network (DirecNet) Study Group, B. Buckingham, D. Xing, S. Weinzimer, R. Fiallo-Scharer, C. Kollman, N. Mauras, E. Tsalikian, W. Tamborlane, R. Wysocki, K. Ruedy, R. Beck, Use of the DirecNet applied treatment algorithm (data) for diabetes management with a real-time continuous glucose monitor (the freestyle navigator). Pediatr. Diabetes 9, 142–147 (2008)PubMedCrossRef
7.
Zurück zum Zitat Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, B. Bode, R.W. Beck, D. Xing, L. Gilliam, I. Hirsch, C. Kollman, L. Laffel, K.J. Ruedy, W.V. Tamborlane, S. Weinzimer, H. Wolpert, Sustained benefit of continuous glucose monitoring on A1c, glucose profiles, and hypoglycemia in adults with type 1 diabetes. Diabetes Care 32, 2047–2049 (2009)PubMedCrossRef Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, B. Bode, R.W. Beck, D. Xing, L. Gilliam, I. Hirsch, C. Kollman, L. Laffel, K.J. Ruedy, W.V. Tamborlane, S. Weinzimer, H. Wolpert, Sustained benefit of continuous glucose monitoring on A1c, glucose profiles, and hypoglycemia in adults with type 1 diabetes. Diabetes Care 32, 2047–2049 (2009)PubMedCrossRef
8.
Zurück zum Zitat R.M. Bergenstal, W.V. Tamborlane, A. Ahmann, J.B. Buse, G. Dailey, S.N. Davis, C. Joyce, T. Peoples, B.A. Perkins, J.B. Welsh, S.M. Willi, M.A. Wood, STAR 3 Study Group, Effectiveness of sensor augmented insulin pump therapy in type 1 diabetes. N. Engl. J. Med. 363, 311–320 (2010)PubMedCrossRef R.M. Bergenstal, W.V. Tamborlane, A. Ahmann, J.B. Buse, G. Dailey, S.N. Davis, C. Joyce, T. Peoples, B.A. Perkins, J.B. Welsh, S.M. Willi, M.A. Wood, STAR 3 Study Group, Effectiveness of sensor augmented insulin pump therapy in type 1 diabetes. N. Engl. J. Med. 363, 311–320 (2010)PubMedCrossRef
9.
Zurück zum Zitat M.L. Misso, K.J. Egberts, M. Page, D. O’Connor, J. Shaw, Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus. Cochr. Datab. Syst. Rev. 1, CD005103 (2010) M.L. Misso, K.J. Egberts, M. Page, D. O’Connor, J. Shaw, Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus. Cochr. Datab. Syst. Rev. 1, CD005103 (2010)
10.
Zurück zum Zitat J.C. Pickup, A.J. Sutton, Severe hypoglycaemia and glycaemic control in type 1diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion. Diabet. Med. 25, 765–774 (2008)PubMedCrossRef J.C. Pickup, A.J. Sutton, Severe hypoglycaemia and glycaemic control in type 1diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion. Diabet. Med. 25, 765–774 (2008)PubMedCrossRef
11.
Zurück zum Zitat T. Battelino, M. Phillip, N. Bratina, R. Nimri, P. Oskarsson, J. Bolinder, Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes. Diabetes Care 34, 795–800 (2011)PubMedCrossRef T. Battelino, M. Phillip, N. Bratina, R. Nimri, P. Oskarsson, J. Bolinder, Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes. Diabetes Care 34, 795–800 (2011)PubMedCrossRef
12.
Zurück zum Zitat M.A. O’Connell, S. Donath, D.N. O’Neal, P.G. Colman, G.R. Ambler, T.W. Jones, E.A. Davis, F.J. Cameron, Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trial. Diabetologia 52, 1250–1257 (2009)PubMedCrossRef M.A. O’Connell, S. Donath, D.N. O’Neal, P.G. Colman, G.R. Ambler, T.W. Jones, E.A. Davis, F.J. Cameron, Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trial. Diabetologia 52, 1250–1257 (2009)PubMedCrossRef
13.
Zurück zum Zitat C.U. Ludwig-Seibold, M. Holder, B. Rami, K. Raile, B. Heidtmann, R. Holl, Continuous glucose monitoring in children, adolescents, and adults with type 1 diabetes mellitus: analysis from the prospective DPV diabetes documentation and quality management system from Germany and Austria. Pediatr. Diabetes 13, 12–14 (2012)PubMedCrossRef C.U. Ludwig-Seibold, M. Holder, B. Rami, K. Raile, B. Heidtmann, R. Holl, Continuous glucose monitoring in children, adolescents, and adults with type 1 diabetes mellitus: analysis from the prospective DPV diabetes documentation and quality management system from Germany and Austria. Pediatr. Diabetes 13, 12–14 (2012)PubMedCrossRef
14.
Zurück zum Zitat R.H. Slowver, J.B. Welsh, A. Criego, S.A. Weinzimer, S.M. Willi, M.A. Wood, W.V. Tamborlane, Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. Pediatr. Diabetes 13, 6–11 (2012)CrossRef R.H. Slowver, J.B. Welsh, A. Criego, S.A. Weinzimer, S.M. Willi, M.A. Wood, W.V. Tamborlane, Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. Pediatr. Diabetes 13, 6–11 (2012)CrossRef
15.
Zurück zum Zitat A.E. Scaramuzza, D. Iafusco, I. Rabbone, R. Bonfanti, F. Lombardo, R. Schiaffini, P. Buono, S. Toni, V. Cherubini, G.V. Zuccotti, Diabetes Study Group of the Italian Society of Paediatric Endocrinology and Diabetology, Use of integrated real-time continuous glucose monitoring/insulin pump system in children and adolescents with type 1 diabetes: a 3-year follow-up study. Diabetes Technol. Ther. 13, 99–103 (2011)PubMedCrossRef A.E. Scaramuzza, D. Iafusco, I. Rabbone, R. Bonfanti, F. Lombardo, R. Schiaffini, P. Buono, S. Toni, V. Cherubini, G.V. Zuccotti, Diabetes Study Group of the Italian Society of Paediatric Endocrinology and Diabetology, Use of integrated real-time continuous glucose monitoring/insulin pump system in children and adolescents with type 1 diabetes: a 3-year follow-up study. Diabetes Technol. Ther. 13, 99–103 (2011)PubMedCrossRef
16.
Zurück zum Zitat O. Kordonouri, E. Pankowska, B. Rami, T. Kapellen, R. Coutant, R. Hartmann, K. Lange, M. Knip, T. Danne, Sensor-augmented pump therapy from the diagnosis of childhood type 1 diabetes: results of the paediatric onset study (ONSET) after 12 months of treatment. Diabetologia 53, 2487–2495 (2010)PubMedCrossRef O. Kordonouri, E. Pankowska, B. Rami, T. Kapellen, R. Coutant, R. Hartmann, K. Lange, M. Knip, T. Danne, Sensor-augmented pump therapy from the diagnosis of childhood type 1 diabetes: results of the paediatric onset study (ONSET) after 12 months of treatment. Diabetologia 53, 2487–2495 (2010)PubMedCrossRef
17.
Zurück zum Zitat N. Mauras, R. Beck, D. Xing, B. Buckingham, M. Tansey, N.H. White, S.A. Weinzimer, W. Tamborlane, C. Kollman, Diabetes Research in Children Network (DirecNet) Study Group, A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to <10 years. Diabetes Care 35, 204–210 (2012)PubMedCrossRef N. Mauras, R. Beck, D. Xing, B. Buckingham, M. Tansey, N.H. White, S.A. Weinzimer, W. Tamborlane, C. Kollman, Diabetes Research in Children Network (DirecNet) Study Group, A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to <10 years. Diabetes Care 35, 204–210 (2012)PubMedCrossRef
18.
Zurück zum Zitat Diabetes Research in Children Network (DirecNet) Study Group, Youth and parent satisfaction with clinical use of the GlucoWatch G2 Biographer in the management of pediatric type 1 diabetes. Diabetes Care 28, 1929–1935 (2005)CrossRef Diabetes Research in Children Network (DirecNet) Study Group, Youth and parent satisfaction with clinical use of the GlucoWatch G2 Biographer in the management of pediatric type 1 diabetes. Diabetes Care 28, 1929–1935 (2005)CrossRef
19.
Zurück zum Zitat J. Ludvigsson, R. Hanas, Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. Pediatrics 111, 933–938 (2003)PubMedCrossRef J. Ludvigsson, R. Hanas, Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. Pediatrics 111, 933–938 (2003)PubMedCrossRef
20.
Zurück zum Zitat K. Yates, A. Hasnat Milton, K. Dear, G. Ambler, Continuous glucose monitoring-guided insulin adjustment in children and adolescents on near-physiological insulin regimens: a randomized controlled trial. Diabetes Care 29, 1512–1517 (2006)PubMedCrossRef K. Yates, A. Hasnat Milton, K. Dear, G. Ambler, Continuous glucose monitoring-guided insulin adjustment in children and adolescents on near-physiological insulin regimens: a randomized controlled trial. Diabetes Care 29, 1512–1517 (2006)PubMedCrossRef
21.
Zurück zum Zitat F.R. Kaufman, L.C. Gibson, M. Halvorson, S. Carpenter, L.K. Fisher, P. Pitukcheewanont, A pilot study of the continuous glucose monitoring system: clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects. Diabetes Care 24, 2030–2034 (2001)PubMedCrossRef F.R. Kaufman, L.C. Gibson, M. Halvorson, S. Carpenter, L.K. Fisher, P. Pitukcheewanont, A pilot study of the continuous glucose monitoring system: clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects. Diabetes Care 24, 2030–2034 (2001)PubMedCrossRef
22.
Zurück zum Zitat D.T. Golicki, D. Golicka, L. Groele, E. Pankowska, Continuous glucose monitoring system in children with type 1 diabetes mellitus: a systematic review and meta-analysis. Diabetologia 51, 233–240 (2008)PubMedCrossRef D.T. Golicki, D. Golicka, L. Groele, E. Pankowska, Continuous glucose monitoring system in children with type 1 diabetes mellitus: a systematic review and meta-analysis. Diabetologia 51, 233–240 (2008)PubMedCrossRef
23.
Zurück zum Zitat W.H. Lagarde, F.P. Barrows, M.L. Davenport, M. Kang, H.A. Guess, A.S. Calikoglu, Continuous subcutaneous glucose monitoring in children with type 1 diabetes mellitus: a single-blind, randomized, controlled trial. Pediatr. Diabetes 7, 159–164 (2006)PubMedCrossRef W.H. Lagarde, F.P. Barrows, M.L. Davenport, M. Kang, H.A. Guess, A.S. Calikoglu, Continuous subcutaneous glucose monitoring in children with type 1 diabetes mellitus: a single-blind, randomized, controlled trial. Pediatr. Diabetes 7, 159–164 (2006)PubMedCrossRef
24.
Zurück zum Zitat H.P. Chase, L.M. Kim, S.L. Owen, T.A. MacKenzie, G.J. Klingensmith, R. Murtfeldt, S.K. Garg, Continuous glucose monitoring in children with type 1 diabetes. Pediatrics 107, 222–226 (2001)PubMedCrossRef H.P. Chase, L.M. Kim, S.L. Owen, T.A. MacKenzie, G.J. Klingensmith, R. Murtfeldt, S.K. Garg, Continuous glucose monitoring in children with type 1 diabetes. Pediatrics 107, 222–226 (2001)PubMedCrossRef
25.
Zurück zum Zitat Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, Prolonged nocturnal hypoglycemia is common during 12 months of continuous glucose monitoring in children and adults with type 1 diabetes. Diabetes Care 33, 1004–1008 (2010)CrossRef Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, Prolonged nocturnal hypoglycemia is common during 12 months of continuous glucose monitoring in children and adults with type 1 diabetes. Diabetes Care 33, 1004–1008 (2010)CrossRef
26.
Zurück zum Zitat P. Adolfsson, S. Nilsson, B. Lindblad, Continuous glucose monitoring system during physical exercise in adolescents with type 1 diabetes. Acta Paediatr. 100, 1603–1609 (2011)PubMedCrossRef P. Adolfsson, S. Nilsson, B. Lindblad, Continuous glucose monitoring system during physical exercise in adolescents with type 1 diabetes. Acta Paediatr. 100, 1603–1609 (2011)PubMedCrossRef
27.
Zurück zum Zitat Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, The effect of continuous glucose monitoring in well controlled type 1 diabetes. Diabetes Care 32, 1378–1383 (2009)CrossRef Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, The effect of continuous glucose monitoring in well controlled type 1 diabetes. Diabetes Care 32, 1378–1383 (2009)CrossRef
28.
Zurück zum Zitat Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, R.W. Beck, J.M. Lawrence, L. Laffel, T. Wysocki, D. Xing, E.S. Huang, B. Ives, C. Kollman, J. Lee, K.J. Ruedy, W.V. Tamborlane, Quality-of-life measures in children and adults with type 1 diabetes: juvenile diabetes research foundation continuous glucose monitoring randomized trial. Diabetes Care 33, 2175–2177 (2010)PubMedCrossRef Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, R.W. Beck, J.M. Lawrence, L. Laffel, T. Wysocki, D. Xing, E.S. Huang, B. Ives, C. Kollman, J. Lee, K.J. Ruedy, W.V. Tamborlane, Quality-of-life measures in children and adults with type 1 diabetes: juvenile diabetes research foundation continuous glucose monitoring randomized trial. Diabetes Care 33, 2175–2177 (2010)PubMedCrossRef
29.
Zurück zum Zitat JDRF CGM Study Group, JDRF randomized clinical trial to assess the efficacy of real-time continuous glucose monitoring in the management of type 1 diabetes: research design and methods. Diabetes Technol. Ther. 10, 310–321 (2008)CrossRef JDRF CGM Study Group, JDRF randomized clinical trial to assess the efficacy of real-time continuous glucose monitoring in the management of type 1 diabetes: research design and methods. Diabetes Technol. Ther. 10, 310–321 (2008)CrossRef
30.
Zurück zum Zitat K. McLachlan, A. Jenkins, D. O’Neal, The role of continuous glucose monitoring in clinical decision-making in diabetes in pregnancy. Aust. N. Z. J. Obstet. Gynaecol. 47, 186–190 (2007)PubMedCrossRef K. McLachlan, A. Jenkins, D. O’Neal, The role of continuous glucose monitoring in clinical decision-making in diabetes in pregnancy. Aust. N. Z. J. Obstet. Gynaecol. 47, 186–190 (2007)PubMedCrossRef
31.
Zurück zum Zitat H.R. Murphy, G. Rayman, K. Duffield, K.S. Lewis, S. Kelly, B. Johal, D. Fowler, R.C. Temple, Changes in the glycemic profiles of women with type 1 and type 2 diabetes during pregnancy. Diabetes Care 30, 2785–2791 (2007)PubMedCrossRef H.R. Murphy, G. Rayman, K. Duffield, K.S. Lewis, S. Kelly, B. Johal, D. Fowler, R.C. Temple, Changes in the glycemic profiles of women with type 1 and type 2 diabetes during pregnancy. Diabetes Care 30, 2785–2791 (2007)PubMedCrossRef
32.
Zurück zum Zitat E. Stenninger, A. Lindqvist, J. Aman, I. Ostlund, E. Schvarcz, Continuous subcutaneous glucose monitoring system in diabetic mothers during labour and postnatal glucose adaptation of their infants. Diabet. Med. 25, 450–454 (2008)PubMedCrossRef E. Stenninger, A. Lindqvist, J. Aman, I. Ostlund, E. Schvarcz, Continuous subcutaneous glucose monitoring system in diabetic mothers during labour and postnatal glucose adaptation of their infants. Diabet. Med. 25, 450–454 (2008)PubMedCrossRef
33.
Zurück zum Zitat M.G. Dalfra, G. Sartore, G. Di Cianni, G. Mello, C. Lencioni, S. Ottanelli, J. Sposato, F. Valgimigli, C. Scuffi, M. Scalese, A. Lapolla, Glucose variability in diabetic pregnancy. Diabetes Technol. Ther. 13, 853–859 (2011)PubMedCrossRef M.G. Dalfra, G. Sartore, G. Di Cianni, G. Mello, C. Lencioni, S. Ottanelli, J. Sposato, F. Valgimigli, C. Scuffi, M. Scalese, A. Lapolla, Glucose variability in diabetic pregnancy. Diabetes Technol. Ther. 13, 853–859 (2011)PubMedCrossRef
34.
Zurück zum Zitat H.R. Murphy, G. Rayman, K. Lewis, S. Kelly, B. Johal, K. Duffield, D. Fowler, P.J. Campbell, R.C. Temple, Effectiveness of continuous glucose monitoring in pregnant women with diabetes: a randomized clinical trial. BMJ 337, a1680 (2008)PubMedCrossRef H.R. Murphy, G. Rayman, K. Lewis, S. Kelly, B. Johal, K. Duffield, D. Fowler, P.J. Campbell, R.C. Temple, Effectiveness of continuous glucose monitoring in pregnant women with diabetes: a randomized clinical trial. BMJ 337, a1680 (2008)PubMedCrossRef
35.
Zurück zum Zitat A.L. Secher, A.B. Madsen, L. Ringholm, C. Barfred, E. Stage, H.U. Andersen, P. Damm, E.R. Mathiesen, Patient satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy in women with diabetes. Diabet. Med. 29, 272–277 (2012)PubMedCrossRef A.L. Secher, A.B. Madsen, L. Ringholm, C. Barfred, E. Stage, H.U. Andersen, P. Damm, E.R. Mathiesen, Patient satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy in women with diabetes. Diabet. Med. 29, 272–277 (2012)PubMedCrossRef
36.
Zurück zum Zitat G. Petrovski, C. Dimitrovski, M. Bogoev, T. Milenkovic, I. Ahmeti, I. Bitovska, Is there a difference in pregnancy and glycemic outcome in patients with type 1 diabetes on insulin pump with constant or intermittent glucose monitoring? A pilot study. Diabetes Technol. Ther. 13, 1109–1113 (2011)PubMedCrossRef G. Petrovski, C. Dimitrovski, M. Bogoev, T. Milenkovic, I. Ahmeti, I. Bitovska, Is there a difference in pregnancy and glycemic outcome in patients with type 1 diabetes on insulin pump with constant or intermittent glucose monitoring? A pilot study. Diabetes Technol. Ther. 13, 1109–1113 (2011)PubMedCrossRef
37.
Zurück zum Zitat L. Messer, K. Ruedy, D. Xing, J. Coffey, K. Englert, K. Caswell, B. Ives, for the Diabetes Research in Children Network (DirecNet) Study Group, Educating families on real time continuous glucose monitoring: the DirecNet Navigator pilot study experience. Diabetes Educ. 35, 124–135 (2009)PubMedCrossRef L. Messer, K. Ruedy, D. Xing, J. Coffey, K. Englert, K. Caswell, B. Ives, for the Diabetes Research in Children Network (DirecNet) Study Group, Educating families on real time continuous glucose monitoring: the DirecNet Navigator pilot study experience. Diabetes Educ. 35, 124–135 (2009)PubMedCrossRef
38.
Zurück zum Zitat M.J. Rice, D.B. Coursin, Continuous measurement of glucose: facts and challenges. Anesthesiology 116, 199–204 (2012)PubMedCrossRef M.J. Rice, D.B. Coursin, Continuous measurement of glucose: facts and challenges. Anesthesiology 116, 199–204 (2012)PubMedCrossRef
39.
Zurück zum Zitat G. McGarraugh, R. Brazg, R. Weinstein, Freestyle navigator continuous glucose monitoring system with trustart algorithm, a 1-h warm-up time. J. Diabetes Sci. Technol. 5, 99–106 (2011) G. McGarraugh, R. Brazg, R. Weinstein, Freestyle navigator continuous glucose monitoring system with trustart algorithm, a 1-h warm-up time. J. Diabetes Sci. Technol. 5, 99–106 (2011)
41.
Zurück zum Zitat E. Tsalikian, L. Fox, S. Weinzimer, B. Buckingham, N.H. White, R. Beck, C. Kollman, D. Xing, K. Ruedy, Diabetes Research in Children Network (DirecNet) Study Group. Feasibility of prolonged continuous glucose monitoring in toddlers with type 1 diabetes. Pediatr. Diabetes 13, 294–300 (2012)CrossRef E. Tsalikian, L. Fox, S. Weinzimer, B. Buckingham, N.H. White, R. Beck, C. Kollman, D. Xing, K. Ruedy, Diabetes Research in Children Network (DirecNet) Study Group. Feasibility of prolonged continuous glucose monitoring in toddlers with type 1 diabetes. Pediatr. Diabetes 13, 294–300 (2012)CrossRef
42.
Zurück zum Zitat P. Choudhary, J. Shin, Y. Wang, M.L. Evans, P.J. Hammond, D. Kerr, J.A. Shaw, J.C. Pickup, S.A. Amiel, Insulin pump therapy with automated insulin suspension in response to hypoglycemia. Diabetes Care 34, 2023–2025 (2011)PubMedCrossRef P. Choudhary, J. Shin, Y. Wang, M.L. Evans, P.J. Hammond, D. Kerr, J.A. Shaw, J.C. Pickup, S.A. Amiel, Insulin pump therapy with automated insulin suspension in response to hypoglycemia. Diabetes Care 34, 2023–2025 (2011)PubMedCrossRef
43.
Zurück zum Zitat J. Mastrototaro, J. Shin, A. Marcus, G. Sulur, for the STAR 1 Clinical Trial Investigators, The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. Diabetes Technol. Ther. 10, 385–390 (2008)PubMedCrossRef J. Mastrototaro, J. Shin, A. Marcus, G. Sulur, for the STAR 1 Clinical Trial Investigators, The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. Diabetes Technol. Ther. 10, 385–390 (2008)PubMedCrossRef
44.
Zurück zum Zitat DexCom Seven Plus®: User Guide (2010) DexCom Seven Plus®: User Guide (2010)
45.
Zurück zum Zitat Medtronic MiniMed iPro2® CGM: User Guide (2010) Medtronic MiniMed iPro2® CGM: User Guide (2010)
46.
Zurück zum Zitat Animas® Vibe Insulin Pump and CGM System: User Guide (2011) Animas® Vibe Insulin Pump and CGM System: User Guide (2011)
47.
Zurück zum Zitat D.B. Keenan, J.J. Mastrototaro, H. Zisser, K.A. Cooper, G. Raghavendhar, S.W. Lee, J. Yusi, T.S. Bailey, R.L. Brazg, R.V. Shah, Accuracy of the Enlite 6-day glucose sensor with guardian and veo calibration algorithms. Diabetes Technol. Ther. 14, 225–231 (2012)PubMedCrossRef D.B. Keenan, J.J. Mastrototaro, H. Zisser, K.A. Cooper, G. Raghavendhar, S.W. Lee, J. Yusi, T.S. Bailey, R.L. Brazg, R.V. Shah, Accuracy of the Enlite 6-day glucose sensor with guardian and veo calibration algorithms. Diabetes Technol. Ther. 14, 225–231 (2012)PubMedCrossRef
Metadaten
Titel
Continuous glucose monitoring in type 1 diabetes
verfasst von
Nelly Mauras
Larry Fox
Kimberly Englert
Roy W. Beck
Publikationsdatum
01.02.2013
Verlag
Springer US
Erschienen in
Endocrine / Ausgabe 1/2013
Print ISSN: 1355-008X
Elektronische ISSN: 1559-0100
DOI
https://doi.org/10.1007/s12020-012-9765-1

Weitere Artikel der Ausgabe 1/2013

Endocrine 1/2013 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Costims – das nächste heiße Ding in der Krebstherapie?

28.05.2024 Onkologische Immuntherapie Nachrichten

„Kalte“ Tumoren werden heiß – CD28-kostimulatorische Antikörper sollen dies ermöglichen. Am besten könnten diese in Kombination mit BiTEs und Checkpointhemmern wirken. Erste klinische Studien laufen bereits.

Perioperative Checkpointhemmer-Therapie verbessert NSCLC-Prognose

28.05.2024 NSCLC Nachrichten

Eine perioperative Therapie mit Nivolumab reduziert das Risiko für Rezidive und Todesfälle bei operablem NSCLC im Vergleich zu einer alleinigen neoadjuvanten Chemotherapie um über 40%. Darauf deuten die Resultate der Phase-3-Studie CheckMate 77T.

Positiver FIT: Die Ursache liegt nicht immer im Dickdarm

27.05.2024 Blut im Stuhl Nachrichten

Immunchemischer Stuhltest positiv, Koloskopie negativ – in solchen Fällen kann die Blutungsquelle auch weiter proximal sitzen. Ein Forschungsteam hat nachgesehen, wie häufig und in welchen Lokalisationen das der Fall ist.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.