The aim of this literature review was to report complications associated with arthroscopic rotator cuff repair (RCR). A computerized search of articles published between 200 and 2009 was performed using MEDLINE and PubMed. We included clinical studies (Level 1–4): (a) investigating patients with rotator cuff tears, managed by a completely arthroscopic RCR technique; (b) reported data about complications. Data about arthroscopic-assisted techniques were excluded. Articles that meet criteria inclusion were analytically examined. Complications were classified into general complications and specific complications related to arthroscopic RCR. We found 414 complications in 2,890 patients; most of them were specific complications related to arthroscopic RCR. Re-rupture was the most frequently encountered complication: re-tear rate ranged between 11.4 and 94%. Stiffness and hardware-related complications were observed in 74 and 12 patients, respectively. Eleven less common complications were also reported: 5 neurovascular, 3 septic, 2 thromboembolic events, and 1 anesthesiological complication. This review stated that arthroscopic RCR is a low-risk surgical procedure. Anatomical failure of the repair is the most common complication encountered in the literature.
Literatur
1.
Zurück zum Zitat Butler DL, Juncosa-Melvin N, Boivin GP, Galloway MT, Shearn JT, Gooch C, Awad H (2008) Functional tissue engineering for tendon repair: a multidisciplinary strategy using mesenchymal stem cells, bioscaffolds, and mechanical stimulation. J Orthop Res 26(1):1–9PubMedCrossRef Butler DL, Juncosa-Melvin N, Boivin GP, Galloway MT, Shearn JT, Gooch C, Awad H (2008) Functional tissue engineering for tendon repair: a multidisciplinary strategy using mesenchymal stem cells, bioscaffolds, and mechanical stimulation. J Orthop Res 26(1):1–9PubMedCrossRef
2.
Zurück zum Zitat Romeo AA, Mazzocca A, Hang DW, Shott S, Bach BR Jr (2004) Shoulder scoring scales for the evaluation of rotator cuff repair. Clin Orthop Relat Res (427):107–114 Romeo AA, Mazzocca A, Hang DW, Shott S, Bach BR Jr (2004) Shoulder scoring scales for the evaluation of rotator cuff repair. Clin Orthop Relat Res (427):107–114
3.
Zurück zum Zitat Galatz LM, Griggs S, Cameron BD, Iannotti JP (2001) Prospective longitudinal analysis of postoperative shoulder function: a ten-year follow-up study of full-thickness rotator cuff tears. J Bone Jt Surg Am 83-A(7):1052–1056 Galatz LM, Griggs S, Cameron BD, Iannotti JP (2001) Prospective longitudinal analysis of postoperative shoulder function: a ten-year follow-up study of full-thickness rotator cuff tears. J Bone Jt Surg Am 83-A(7):1052–1056
4.
Zurück zum Zitat Iannotti JP (1994) Full-thickness rotator cuff tears: factors affecting surgical outcome. J Am Acad Orthop Surg 2(2):87–95PubMed Iannotti JP (1994) Full-thickness rotator cuff tears: factors affecting surgical outcome. J Am Acad Orthop Surg 2(2):87–95PubMed
5.
Zurück zum Zitat Gartsman GM, Khan M, Hammerman SM (1998) Arthroscopic repair of full-thickness tears of the rotator cuff. J Bone Jt Surg Am 80(6):832–840 Gartsman GM, Khan M, Hammerman SM (1998) Arthroscopic repair of full-thickness tears of the rotator cuff. J Bone Jt Surg Am 80(6):832–840
6.
Zurück zum Zitat Gartsman GM, Brinker MR, Khan M (1998) Early effectiveness of arthroscopic repair for full-thickness tears of the rotator cuff: an outcome analysis. J Bone Jt Surg Am 80(1):33–40CrossRef Gartsman GM, Brinker MR, Khan M (1998) Early effectiveness of arthroscopic repair for full-thickness tears of the rotator cuff: an outcome analysis. J Bone Jt Surg Am 80(1):33–40CrossRef
7.
Zurück zum Zitat Hersch JC, Sgaglione NA (2000) Arthroscopically assisted mini-open rotator cuff repairs. Functional outcome at 2- to 7-year follow-up. Am J Sports Med 28(3):301–311PubMed Hersch JC, Sgaglione NA (2000) Arthroscopically assisted mini-open rotator cuff repairs. Functional outcome at 2- to 7-year follow-up. Am J Sports Med 28(3):301–311PubMed
8.
Zurück zum Zitat Warner JJ, Tetreault P, Lehtinen J, Zurakowski D (2005) Arthroscopic versus mini-open rotator cuff repair: a cohort comparison study. Arthroscopy 21(3):328–332PubMedCrossRef Warner JJ, Tetreault P, Lehtinen J, Zurakowski D (2005) Arthroscopic versus mini-open rotator cuff repair: a cohort comparison study. Arthroscopy 21(3):328–332PubMedCrossRef
9.
Zurück zum Zitat Wolf EM, Pennington WT, Agrawal V (2004) Arthroscopic rotator cuff repair: 4- to 10-year results. Arthroscopy 20(1):5–12PubMedCrossRef Wolf EM, Pennington WT, Agrawal V (2004) Arthroscopic rotator cuff repair: 4- to 10-year results. Arthroscopy 20(1):5–12PubMedCrossRef
10.
Zurück zum Zitat Tauro JC (2004) Arthroscopic repair of large rotator cuff tears using the interval slide technique. Arthroscopy 20(1):13–21PubMedCrossRef Tauro JC (2004) Arthroscopic repair of large rotator cuff tears using the interval slide technique. Arthroscopy 20(1):13–21PubMedCrossRef
11.
Zurück zum Zitat Bittar ES (2002) Arthroscopic management of massive rotator cuff tears. Arthroscopy 18(9 Suppl 2):104–106PubMed Bittar ES (2002) Arthroscopic management of massive rotator cuff tears. Arthroscopy 18(9 Suppl 2):104–106PubMed
12.
Zurück zum Zitat Brislin KJ, Field LD, Savoie FH 3rd (2007) Complications after arthroscopic rotator cuff repair. Arthroscopy 23(2):124–128PubMedCrossRef Brislin KJ, Field LD, Savoie FH 3rd (2007) Complications after arthroscopic rotator cuff repair. Arthroscopy 23(2):124–128PubMedCrossRef
13.
Zurück zum Zitat Buess E, Steuber KU, Waibl B (2005) Open versus arthroscopic rotator cuff repair: a comparative view of 96 cases. Arthroscopy 21(5):597–604PubMedCrossRef Buess E, Steuber KU, Waibl B (2005) Open versus arthroscopic rotator cuff repair: a comparative view of 96 cases. Arthroscopy 21(5):597–604PubMedCrossRef
14.
15.
Zurück zum Zitat Cummins CA, Murrell GA (2003) Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Should Elb Surg 12(2):128–133CrossRef Cummins CA, Murrell GA (2003) Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Should Elb Surg 12(2):128–133CrossRef
16.
Zurück zum Zitat Huberty DP, Schoolfield JD, Brady PC, Vadala AP, Arrigoni P, Burkhart SS (2009) Incidence and treatment of postoperative stiffness following arthroscopic rotator cuff repair. Arthroscopy 25(8):880–890PubMedCrossRef Huberty DP, Schoolfield JD, Brady PC, Vadala AP, Arrigoni P, Burkhart SS (2009) Incidence and treatment of postoperative stiffness following arthroscopic rotator cuff repair. Arthroscopy 25(8):880–890PubMedCrossRef
17.
Zurück zum Zitat Murray TF Jr, Lajtai G, Mileski RM, Snyder SJ (2002) Arthroscopic repair of medium to large full-thickness rotator cuff tears: outcome at 2- to 6-year follow-up. J Should Elb Surg 11(1):19–24CrossRef Murray TF Jr, Lajtai G, Mileski RM, Snyder SJ (2002) Arthroscopic repair of medium to large full-thickness rotator cuff tears: outcome at 2- to 6-year follow-up. J Should Elb Surg 11(1):19–24CrossRef
18.
Zurück zum Zitat Wilson F, Hinov V, Adams G (2002) Arthroscopic repair of full-thickness tears of the rotator cuff: 2- to 14-year follow-up. Arthroscopy 18(2):136–144PubMedCrossRef Wilson F, Hinov V, Adams G (2002) Arthroscopic repair of full-thickness tears of the rotator cuff: 2- to 14-year follow-up. Arthroscopy 18(2):136–144PubMedCrossRef
19.
Zurück zum Zitat Youm T, Murray DH, Kubiak EN, Rokito AS, Zuckerman JD (2005) Arthroscopic versus mini-open rotator cuff repair: a comparison of clinical outcomes and patient satisfaction. J Should Elb Surg 14(5):455–459CrossRef Youm T, Murray DH, Kubiak EN, Rokito AS, Zuckerman JD (2005) Arthroscopic versus mini-open rotator cuff repair: a comparison of clinical outcomes and patient satisfaction. J Should Elb Surg 14(5):455–459CrossRef
20.
Zurück zum Zitat Sugaya H, Maeda K, Matsuki K, Moriishi J (2007) Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Jt Surg Am 89(5):953–960CrossRef Sugaya H, Maeda K, Matsuki K, Moriishi J (2007) Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Jt Surg Am 89(5):953–960CrossRef
21.
Zurück zum Zitat Lichtenberg S, Liem D, Magosch P, Habermeyer P (2006) Influence of tendon healing after arthroscopic rotator cuff repair on clinical outcome using single-row Mason-Allen suture technique: a prospective, MRI controlled study. Knee Surg Sports Traumatol Arthrosc 14(11):1200–1206PubMedCrossRef Lichtenberg S, Liem D, Magosch P, Habermeyer P (2006) Influence of tendon healing after arthroscopic rotator cuff repair on clinical outcome using single-row Mason-Allen suture technique: a prospective, MRI controlled study. Knee Surg Sports Traumatol Arthrosc 14(11):1200–1206PubMedCrossRef
22.
Zurück zum Zitat Lafosse L, Jost B, Reiland Y, Audebert S, Toussaint B, Gobezie R (2007) Structural integrity and clinical outcomes after arthroscopic repair of isolated subscapularis tears. J Bone Jt Surg Am 89(6):1184–1193CrossRef Lafosse L, Jost B, Reiland Y, Audebert S, Toussaint B, Gobezie R (2007) Structural integrity and clinical outcomes after arthroscopic repair of isolated subscapularis tears. J Bone Jt Surg Am 89(6):1184–1193CrossRef
23.
Zurück zum Zitat Anderson K, Boothby M, Aschenbrener D, van Holsbeeck M (2006) Outcome and structural integrity after arthroscopic rotator cuff repair using 2 rows of fixation: minimum 2-year follow-up. Am J Sports Med 34(12):1899–1905PubMedCrossRef Anderson K, Boothby M, Aschenbrener D, van Holsbeeck M (2006) Outcome and structural integrity after arthroscopic rotator cuff repair using 2 rows of fixation: minimum 2-year follow-up. Am J Sports Med 34(12):1899–1905PubMedCrossRef
24.
Zurück zum Zitat Bishop J, Klepps S, Lo IK, Bird J, Gladstone JN, Flatow EL (2006) Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Should Elb Surg 15(3):290–299CrossRef Bishop J, Klepps S, Lo IK, Bird J, Gladstone JN, Flatow EL (2006) Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Should Elb Surg 15(3):290–299CrossRef
25.
Zurück zum Zitat Boileau P, Brassart N, Watkinson DJ, Carles M, Hatzidakis AM, Krishnan SG (2005) Arthroscopic repair of full-thickness tears of the supraspinatus: does the tendon really heal? J Bone Jt Surg Am 87(6):1229–1240CrossRef Boileau P, Brassart N, Watkinson DJ, Carles M, Hatzidakis AM, Krishnan SG (2005) Arthroscopic repair of full-thickness tears of the supraspinatus: does the tendon really heal? J Bone Jt Surg Am 87(6):1229–1240CrossRef
26.
Zurück zum Zitat Bond JL, Dopirak RM, Higgins J, Burns J, Snyder SJ (2008) Arthroscopic replacement of massive, irreparable rotator cuff tears using a GraftJacket allograft: technique and preliminary results. Arthroscopy 24(4):403–409 e401 Bond JL, Dopirak RM, Higgins J, Burns J, Snyder SJ (2008) Arthroscopic replacement of massive, irreparable rotator cuff tears using a GraftJacket allograft: technique and preliminary results. Arthroscopy 24(4):403–409 e401
27.
Zurück zum Zitat Charousset C, Grimberg J, Duranthon LD, Bellaiche L, Petrover D, Kalra K (2008) The time for functional recovery after arthroscopic rotator cuff repair: correlation with tendon healing controlled by computed tomography arthrography. Arthroscopy 24(1):25–33PubMedCrossRef Charousset C, Grimberg J, Duranthon LD, Bellaiche L, Petrover D, Kalra K (2008) The time for functional recovery after arthroscopic rotator cuff repair: correlation with tendon healing controlled by computed tomography arthrography. Arthroscopy 24(1):25–33PubMedCrossRef
28.
Zurück zum Zitat Cole BJ, McCarty LP 3rd, Kang RW, Alford W, Lewis PB, Hayden JK (2007) Arthroscopic rotator cuff repair: prospective functional outcome and repair integrity at minimum 2-year follow-up. J Should Elb Surg 16(5):579–585CrossRef Cole BJ, McCarty LP 3rd, Kang RW, Alford W, Lewis PB, Hayden JK (2007) Arthroscopic rotator cuff repair: prospective functional outcome and repair integrity at minimum 2-year follow-up. J Should Elb Surg 16(5):579–585CrossRef
29.
Zurück zum Zitat DeFranco MJ, Bershadsky B, Ciccone J, Yum JK, Iannotti JP (2007) Functional outcome of arthroscopic rotator cuff repairs: a correlation of anatomic and clinical results. J Should Elb Surg 16(6):759–765CrossRef DeFranco MJ, Bershadsky B, Ciccone J, Yum JK, Iannotti JP (2007) Functional outcome of arthroscopic rotator cuff repairs: a correlation of anatomic and clinical results. J Should Elb Surg 16(6):759–765CrossRef
30.
Zurück zum Zitat Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Jt Surg Am 86-A(2):219–224 Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Jt Surg Am 86-A(2):219–224
31.
Zurück zum Zitat Kamath G, Galatz LM, Keener JD, Teefey S, Middleton W, Yamaguchi K (2009) Tendon integrity and functional outcome after arthroscopic repair of high-grade partial-thickness supraspinatus tears. J Bone Jt Surg Am 91(5):1055–1062CrossRef Kamath G, Galatz LM, Keener JD, Teefey S, Middleton W, Yamaguchi K (2009) Tendon integrity and functional outcome after arthroscopic repair of high-grade partial-thickness supraspinatus tears. J Bone Jt Surg Am 91(5):1055–1062CrossRef
32.
Zurück zum Zitat Lafosse L, Brozska R, Toussaint B, Gobezie R (2007) The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Jt Surg Am 89(7):1533–1541CrossRef Lafosse L, Brozska R, Toussaint B, Gobezie R (2007) The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Jt Surg Am 89(7):1533–1541CrossRef
33.
Zurück zum Zitat Levy O, Venkateswaran B, Even T, Ravenscroft M, Copeland S (2008) Mid-term clinical and sonographic outcome of arthroscopic repair of the rotator cuff. J Bone Jt Surg Br 90(10):1341–1347CrossRef Levy O, Venkateswaran B, Even T, Ravenscroft M, Copeland S (2008) Mid-term clinical and sonographic outcome of arthroscopic repair of the rotator cuff. J Bone Jt Surg Br 90(10):1341–1347CrossRef
34.
Zurück zum Zitat Oh JH, Kim SH, Ji HM, Jo KH, Bin SW, Gong HS (2009) Prognostic factors affecting anatomic outcome of rotator cuff repair and correlation with functional outcome. Arthroscopy 25(1):30–39PubMedCrossRef Oh JH, Kim SH, Ji HM, Jo KH, Bin SW, Gong HS (2009) Prognostic factors affecting anatomic outcome of rotator cuff repair and correlation with functional outcome. Arthroscopy 25(1):30–39PubMedCrossRef
35.
Zurück zum Zitat Sugaya H, Maeda K, Matsuki K, Moriishi J (2005) Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy 21(11):1307–1316PubMedCrossRef Sugaya H, Maeda K, Matsuki K, Moriishi J (2005) Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy 21(11):1307–1316PubMedCrossRef
36.
Zurück zum Zitat Verma NN, Dunn W, Adler RS, Cordasco FA, Allen A, MacGillivray J, Craig E, Warren RF, Altchek DW (2006) All-arthroscopic versus mini-open rotator cuff repair: a retrospective review with minimum 2-year follow-up. Arthroscopy 22(6):587–594PubMedCrossRef Verma NN, Dunn W, Adler RS, Cordasco FA, Allen A, MacGillivray J, Craig E, Warren RF, Altchek DW (2006) All-arthroscopic versus mini-open rotator cuff repair: a retrospective review with minimum 2-year follow-up. Arthroscopy 22(6):587–594PubMedCrossRef
37.
Zurück zum Zitat Yoo JC, Ahn JH, Koh KH, Lim KS (2009) Rotator cuff integrity after arthroscopic repair for large tears with less-than-optimal footprint coverage. Arthroscopy 25(10):1093–1100PubMedCrossRef Yoo JC, Ahn JH, Koh KH, Lim KS (2009) Rotator cuff integrity after arthroscopic repair for large tears with less-than-optimal footprint coverage. Arthroscopy 25(10):1093–1100PubMedCrossRef
38.
Zurück zum Zitat Park JY, Chung KT, Yoo MJ (2004) A serial comparison of arthroscopic repairs for partial- and full-thickness rotator cuff tears. Arthroscopy 20(7):705–711PubMedCrossRef Park JY, Chung KT, Yoo MJ (2004) A serial comparison of arthroscopic repairs for partial- and full-thickness rotator cuff tears. Arthroscopy 20(7):705–711PubMedCrossRef
39.
Zurück zum Zitat Severud EL, Ruotolo C, Abbott DD, Nottage WM (2003) All-arthroscopic versus mini-open rotator cuff repair: A long-term retrospective outcome comparison. Arthroscopy 19(3):234–238PubMedCrossRef Severud EL, Ruotolo C, Abbott DD, Nottage WM (2003) All-arthroscopic versus mini-open rotator cuff repair: A long-term retrospective outcome comparison. Arthroscopy 19(3):234–238PubMedCrossRef
40.
Zurück zum Zitat Kelly JD 2nd (2005) Disintegration of an absorbable rotator cuff anchor six weeks after implantation. Arthroscopy 21(4):495–497PubMedCrossRef Kelly JD 2nd (2005) Disintegration of an absorbable rotator cuff anchor six weeks after implantation. Arthroscopy 21(4):495–497PubMedCrossRef
41.
Zurück zum Zitat Barber FA (2007) Biodegradable shoulder anchors have unique modes of failure. Arthroscopy 23(3):316–320PubMedCrossRef Barber FA (2007) Biodegradable shoulder anchors have unique modes of failure. Arthroscopy 23(3):316–320PubMedCrossRef
42.
Zurück zum Zitat Burns JP, Snyder SJ (2008) Arthroscopic rotator cuff repair in patients younger than fifty years of age. J Should Elb Surg 17(1):90–96CrossRef Burns JP, Snyder SJ (2008) Arthroscopic rotator cuff repair in patients younger than fifty years of age. J Should Elb Surg 17(1):90–96CrossRef
43.
Zurück zum Zitat Henn RF 3rd, Kang L, Tashjian RZ, Green A (2008) Patients with workers’ compensation claims have worse outcomes after rotator cuff repair. J Bone Jt Surg Am 90(10):2105–2113CrossRef Henn RF 3rd, Kang L, Tashjian RZ, Green A (2008) Patients with workers’ compensation claims have worse outcomes after rotator cuff repair. J Bone Jt Surg Am 90(10):2105–2113CrossRef
44.
Zurück zum Zitat Liem D, Bartl C, Lichtenberg S, Magosch P, Habermeyer P (2007) Clinical outcome and tendon integrity of arthroscopic versus mini-open supraspinatus tendon repair: a magnetic resonance imaging-controlled matched-pair analysis. Arthroscopy 23(5):514–521PubMedCrossRef Liem D, Bartl C, Lichtenberg S, Magosch P, Habermeyer P (2007) Clinical outcome and tendon integrity of arthroscopic versus mini-open supraspinatus tendon repair: a magnetic resonance imaging-controlled matched-pair analysis. Arthroscopy 23(5):514–521PubMedCrossRef
45.
Zurück zum Zitat Tauro JC (2006) Stiffness and rotator cuff tears: incidence, arthroscopic findings, and treatment results. Arthroscopy 22(6):581–586PubMedCrossRef Tauro JC (2006) Stiffness and rotator cuff tears: incidence, arthroscopic findings, and treatment results. Arthroscopy 22(6):581–586PubMedCrossRef
46.
Zurück zum Zitat McBirnie JM, Miniaci A, Miniaci SL (2005) Arthroscopic repair of full-thickness rotator cuff tears using bioabsorbable tacks. Arthroscopy 21(12):1421–1427PubMedCrossRef McBirnie JM, Miniaci A, Miniaci SL (2005) Arthroscopic repair of full-thickness rotator cuff tears using bioabsorbable tacks. Arthroscopy 21(12):1421–1427PubMedCrossRef
47.
Zurück zum Zitat Barber FA, Herbert MA, Click JN (1997) Internal fixation strength of suture anchors–update 1997. Arthroscopy 13(3):355–362PubMedCrossRef Barber FA, Herbert MA, Click JN (1997) Internal fixation strength of suture anchors–update 1997. Arthroscopy 13(3):355–362PubMedCrossRef
48.
Zurück zum Zitat Cortes ZE, Hammerman SM, Gartsman GM (2007) Pulmonary embolism after shoulder arthroscopy: could patient positioning and traction make a difference? J Should Elb Surg 16(2):e16–e17CrossRef Cortes ZE, Hammerman SM, Gartsman GM (2007) Pulmonary embolism after shoulder arthroscopy: could patient positioning and traction make a difference? J Should Elb Surg 16(2):e16–e17CrossRef
49.
Zurück zum Zitat Krishnan SG, Harkins DC, Schiffern SC, Pennington SD, Burkhead WZ (2008) Arthroscopic repair of full-thickness tears of the rotator cuff in patients younger than 40 years. Arthroscopy 24(3):324–328PubMedCrossRef Krishnan SG, Harkins DC, Schiffern SC, Pennington SD, Burkhead WZ (2008) Arthroscopic repair of full-thickness tears of the rotator cuff in patients younger than 40 years. Arthroscopy 24(3):324–328PubMedCrossRef
50.
Zurück zum Zitat Bryant L, Shnier R, Bryant C, Murrell GA (2002) A comparison of clinical estimation, ultrasonography, magnetic resonance imaging, and arthroscopy in determining the size of rotator cuff tears. J Should Elb Surg 11(3):219–224CrossRef Bryant L, Shnier R, Bryant C, Murrell GA (2002) A comparison of clinical estimation, ultrasonography, magnetic resonance imaging, and arthroscopy in determining the size of rotator cuff tears. J Should Elb Surg 11(3):219–224CrossRef
51.
Zurück zum Zitat Teefey SA, Rubin DA, Middleton WD, Hildebolt CF, Leibold RA, Yamaguchi K (2004) Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases. J Bone Jt Surg Am 86-A(4):708–716 Teefey SA, Rubin DA, Middleton WD, Hildebolt CF, Leibold RA, Yamaguchi K (2004) Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases. J Bone Jt Surg Am 86-A(4):708–716
52.
Zurück zum Zitat Barber FA, Herbert MA, Coons DA, Boothby MH (2006) Sutures and suture anchors–update 2006. Arthroscopy 22(10):1063 e1061–1069 Barber FA, Herbert MA, Coons DA, Boothby MH (2006) Sutures and suture anchors–update 2006. Arthroscopy 22(10):1063 e1061–1069
53.
Zurück zum Zitat Barber FA, Herbert MA, Richards DP (2003) Sutures, suture anchors: update 2003. Arthroscopy 19(9):985–990PubMedCrossRef Barber FA, Herbert MA, Richards DP (2003) Sutures, suture anchors: update 2003. Arthroscopy 19(9):985–990PubMedCrossRef
54.
Zurück zum Zitat Shea KP, O’Keefe RM Jr, Fulkerson JP (1992) Comparison of initial pull-out strength of arthroscopic suture and staple Bankart repair techniques. Arthroscopy 8(2):179–182PubMedCrossRef Shea KP, O’Keefe RM Jr, Fulkerson JP (1992) Comparison of initial pull-out strength of arthroscopic suture and staple Bankart repair techniques. Arthroscopy 8(2):179–182PubMedCrossRef
55.
Zurück zum Zitat Dejong ES, DeBerardino TM, Brooks DE, Judson K (2004) In vivo comparison of a metal versus a biodegradable suture anchor. Arthroscopy 20(5):511–516PubMedCrossRef Dejong ES, DeBerardino TM, Brooks DE, Judson K (2004) In vivo comparison of a metal versus a biodegradable suture anchor. Arthroscopy 20(5):511–516PubMedCrossRef
56.
Zurück zum Zitat Randelli P, Castagna A, Cabitza F, Cabitza P, Arrigoni P, Denti M (2010) Infectious and thromboembolic complications of arthroscopic shoulder surgery. J Should Elb Surg 19(1):97–101CrossRef Randelli P, Castagna A, Cabitza F, Cabitza P, Arrigoni P, Denti M (2010) Infectious and thromboembolic complications of arthroscopic shoulder surgery. J Should Elb Surg 19(1):97–101CrossRef
57.
Zurück zum Zitat Burkhart SS, Danaceau SM, Pearce CE Jr (2001) Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair. Arthroscopy 17(9):905–912PubMedCrossRef Burkhart SS, Danaceau SM, Pearce CE Jr (2001) Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair. Arthroscopy 17(9):905–912PubMedCrossRef
Metadaten
Titel
Complications associated with arthroscopic rotator cuff repair: a literature review
verfasst von
P. Randelli
P. Spennacchio
V. Ragone
P. Arrigoni
A. Casella
P. Cabitza
Publikationsdatum
01.06.2012
Verlag
Springer Milan
Erschienen in
MUSCULOSKELETAL SURGERY / Ausgabe 1/2012
Print ISSN: 2035-5106
Elektronische ISSN: 2035-5114
DOI
https://doi.org/10.1007/s12306-011-0175-y

Weitere Artikel der Ausgabe 1/2012

MUSCULOSKELETAL SURGERY 1/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.