Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 2/2011

01.02.2011 | Knee

Loop security and tensile properties of polyblend and traditional suture materials

verfasst von: Mehmet Türker, Önder Kılıçoğlu, Ahmet Salduz, Ergun Bozdağ, Emin Sünbüloğlu

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 2/2011

Einloggen, um Zugang zu erhalten

Abstract

Tensile and knot properties of new generation (polyblend) and traditional suture materials in orthopedic surgery were investigated in standard laboratory conditions. Study focused on Fiberwire No. 5 and 2, Ethibond No. 5, 2 and 00, Orthocord No. 2, MaxBraid No. 2, Prolene No. 0 and 00, PDS No. 0 and 00, and Vicryl No. 2, 0 and 00. A 27-cm suture loop was fastened with 10 knots for ten samples for each type. Test parameters were tensile load to failure, elongation at failure point and knot slippage, and volume of 10-fold knots. Results were compared using ANOVA test. Failure load of No. 5 Fiberwire (625.0 ± 30.0 N) was significantly higher compared to all other suture types. Tensile strengths of MaxBraid No. 2 (287 ± 11 N) was significantly stronger compared to two other No. 2 polyblend sutures types and Ethibond No. 5. Knot slippage of Fiberwire No. 5 (14 ± 1.9 mm) was significantly higher compared to all other suture types. Ethibond No. 2 (0.1 ± 0.3 mm) had the lowest knot slippage. Elongation at the failure point of Fiberwire No. 2 (5%) was significantly lower than all other suture types. Mean calculated knot volume of #5 Fiberwire (73 ± 6.9 mm3) was significantly higher compared to #5 Ethibond (53 ± 4.8 mm3). Results of the study proved presence of significant differences between tensile and knot properties of various suture types and sizes. Loop security of larger diameter sutures is not always higher than thinner sutures. Suture elongation and knot slippage are important failure modes for high-diameter sutures and short-suture loops.
Literatur
1.
Zurück zum Zitat Abbi G, Espinoza L, Odell T, Mahar A, Pedowitz R (2006) Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: very strong sutures can still slip. Arthroscopy 22:38–43CrossRefPubMed Abbi G, Espinoza L, Odell T, Mahar A, Pedowitz R (2006) Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: very strong sutures can still slip. Arthroscopy 22:38–43CrossRefPubMed
2.
Zurück zum Zitat Barber FA, Herbert MA, Beavis RC (2009) Cyclic load and failure behavior of arthroscopic knots and high strength sutures. Arthroscopy 25(2):192–199CrossRefPubMed Barber FA, Herbert MA, Beavis RC (2009) Cyclic load and failure behavior of arthroscopic knots and high strength sutures. Arthroscopy 25(2):192–199CrossRefPubMed
3.
Zurück zum Zitat Barber FA, Herbert MA, Beavis RC, Barrera Oro F (2008) Suture anchor materials, eyelets, and designs: update 2008. Arthroscopy 24:859–867CrossRefPubMed Barber FA, Herbert MA, Beavis RC, Barrera Oro F (2008) Suture anchor materials, eyelets, and designs: update 2008. Arthroscopy 24:859–867CrossRefPubMed
4.
Zurück zum Zitat Benthien RA, Aronow MS, Doran-Diaz V, Sullivan RJ, Naujoks R (2006) Cyclic loading of Achilles tendon repairs: a comparison of polyester and polyblend suture. Foot Ankle Int 27:512–518PubMed Benthien RA, Aronow MS, Doran-Diaz V, Sullivan RJ, Naujoks R (2006) Cyclic loading of Achilles tendon repairs: a comparison of polyester and polyblend suture. Foot Ankle Int 27:512–518PubMed
5.
Zurück zum Zitat Burkhart SS, Wirth MA, Simonick M, Salem D, Athanasiou K (1998) Loop security as a determinant of tissue fixation security. Arthroscopy 14:773–776CrossRefPubMed Burkhart SS, Wirth MA, Simonick M, Salem D, Athanasiou K (1998) Loop security as a determinant of tissue fixation security. Arthroscopy 14:773–776CrossRefPubMed
6.
Zurück zum Zitat Burkhart SS, Wirth MA, Simonick M, Salem D, Lanctot D, Athanasiou K (2000) Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure the knot must be? Arthroscopy 16:202–207CrossRefPubMed Burkhart SS, Wirth MA, Simonick M, Salem D, Lanctot D, Athanasiou K (2000) Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure the knot must be? Arthroscopy 16:202–207CrossRefPubMed
7.
Zurück zum Zitat Elkousy HA, Sekiya JK, Stabile KJ, McMahon PJ (2005) A biomechanical comparison of arthroscopic sliding and sliding-locking knots. Arthroscopy 21:204–210CrossRefPubMed Elkousy HA, Sekiya JK, Stabile KJ, McMahon PJ (2005) A biomechanical comparison of arthroscopic sliding and sliding-locking knots. Arthroscopy 21:204–210CrossRefPubMed
8.
Zurück zum Zitat Gebauer M, Beil FT, Beckmann J, Sarvary AM, Ueblacker P, Ruecker AH, Holste J, Meenen NM (2007) Mechanical evaluation of different techniques for Achilles tendon repair. Arch Orthop Trauma Surg 127:795–799CrossRefPubMed Gebauer M, Beil FT, Beckmann J, Sarvary AM, Ueblacker P, Ruecker AH, Holste J, Meenen NM (2007) Mechanical evaluation of different techniques for Achilles tendon repair. Arch Orthop Trauma Surg 127:795–799CrossRefPubMed
9.
Zurück zum Zitat Ilahi OA, Younas SA, Ho DM, Noble PC (2008) Security of knots tied with Ethibond, Fiberwire, Orthocord and Ultrabraid. Am J Sports Med 36:2407–2414CrossRefPubMed Ilahi OA, Younas SA, Ho DM, Noble PC (2008) Security of knots tied with Ethibond, Fiberwire, Orthocord and Ultrabraid. Am J Sports Med 36:2407–2414CrossRefPubMed
10.
Zurück zum Zitat Jo CH, Lee JH, Kang SB, Lee JH, Han HS, Bae TS, Choi K, Lee C, Lee MC, Yoon KS (2008) Optimal configuration of arthroscopic sliding knots backed up with multiple half-hitches. Knee Surg Sports Traumatol Arthrosc 16:787–793CrossRefPubMed Jo CH, Lee JH, Kang SB, Lee JH, Han HS, Bae TS, Choi K, Lee C, Lee MC, Yoon KS (2008) Optimal configuration of arthroscopic sliding knots backed up with multiple half-hitches. Knee Surg Sports Traumatol Arthrosc 16:787–793CrossRefPubMed
11.
Zurück zum Zitat Lewis N, Quitkin HM (2003) Strength analysis and comparison of the Teno Fix tendon repair system with the two-strand modified Kessler repair in the Achilles tendon. Foot Ankle Int 24:857–860PubMed Lewis N, Quitkin HM (2003) Strength analysis and comparison of the Teno Fix tendon repair system with the two-strand modified Kessler repair in the Achilles tendon. Foot Ankle Int 24:857–860PubMed
12.
Zurück zum Zitat Lieurance RK, Pflaster DS, Abbott D, Nattage WM (2003) Failure characteristics of various arthroscopically tied knots. Clin Orthop Relat Res 408:311–318CrossRefPubMed Lieurance RK, Pflaster DS, Abbott D, Nattage WM (2003) Failure characteristics of various arthroscopically tied knots. Clin Orthop Relat Res 408:311–318CrossRefPubMed
13.
Zurück zum Zitat Lo IKY, Burkhart SS, Chan C, Athanasiou K (2004) Arthroscopic knots: determining the optimal balance of loop security and knot security. Arthroscopy 20:489–502CrossRefPubMed Lo IKY, Burkhart SS, Chan C, Athanasiou K (2004) Arthroscopic knots: determining the optimal balance of loop security and knot security. Arthroscopy 20:489–502CrossRefPubMed
14.
Zurück zum Zitat Loutzenheiser TD, Harryman DT 2nd, Yung SW, France MP, Sidles JA (1995) Optimizing arthroscopic knots. Arthroscopy 11:199–206CrossRefPubMed Loutzenheiser TD, Harryman DT 2nd, Yung SW, France MP, Sidles JA (1995) Optimizing arthroscopic knots. Arthroscopy 11:199–206CrossRefPubMed
15.
Zurück zum Zitat Mahar A, Odell T, Thomas W, Pedowitz R (2002) A biomechanical analysis of a novel arthroscopic suture method compared to standard suture knots and materials for rotator cuff repair. Arthroscopy 23:1162–1166CrossRef Mahar A, Odell T, Thomas W, Pedowitz R (2002) A biomechanical analysis of a novel arthroscopic suture method compared to standard suture knots and materials for rotator cuff repair. Arthroscopy 23:1162–1166CrossRef
16.
Zurück zum Zitat Mahar A, Moezzi D, Serra-Hsu F, Pedowitz R (2002) Comparison and performance characteristics of two suture materials for shoulder arthroscopy. Arthroscopy 22:614.e1–614.e2 Mahar A, Moezzi D, Serra-Hsu F, Pedowitz R (2002) Comparison and performance characteristics of two suture materials for shoulder arthroscopy. Arthroscopy 22:614.e1–614.e2
17.
Zurück zum Zitat McKeon BP, Heming JF, Fulkerson J, Langeland R (2006) The Krackow stitch: a biomechanical evaluation of changing the number of loops versus the number of sutures. Arthroscopy 22:33–37CrossRefPubMed McKeon BP, Heming JF, Fulkerson J, Langeland R (2006) The Krackow stitch: a biomechanical evaluation of changing the number of loops versus the number of sutures. Arthroscopy 22:33–37CrossRefPubMed
18.
Zurück zum Zitat Shah MR, Strauss EJ, Kaplan K, Jazrawi L, Rosen J (2007) Initial loop and knot security of arthroscopic knots using high-strength sutures. Arthroscopy 23:884–888CrossRefPubMed Shah MR, Strauss EJ, Kaplan K, Jazrawi L, Rosen J (2007) Initial loop and knot security of arthroscopic knots using high-strength sutures. Arthroscopy 23:884–888CrossRefPubMed
19.
Zurück zum Zitat Swan KG Jr, Baldini T, McCarty EC (2009) Arthroscopic suture material and knot type: an updated biomechanical analysis. Am J Sports Med 37:1578–1585CrossRefPubMed Swan KG Jr, Baldini T, McCarty EC (2009) Arthroscopic suture material and knot type: an updated biomechanical analysis. Am J Sports Med 37:1578–1585CrossRefPubMed
20.
Zurück zum Zitat Wüst DM, Meyer DC, Favre P, Gerber C (2006) Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures. Arthroscopy 22:1146–1153CrossRefPubMed Wüst DM, Meyer DC, Favre P, Gerber C (2006) Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures. Arthroscopy 22:1146–1153CrossRefPubMed
Metadaten
Titel
Loop security and tensile properties of polyblend and traditional suture materials
verfasst von
Mehmet Türker
Önder Kılıçoğlu
Ahmet Salduz
Ergun Bozdağ
Emin Sünbüloğlu
Publikationsdatum
01.02.2011
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 2/2011
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1186-1

Weitere Artikel der Ausgabe 2/2011

Knee Surgery, Sports Traumatology, Arthroscopy 2/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.