Skip to main content
Erschienen in: Neuroradiology 11/2005

01.11.2005 | Interventional Neuroradiology

Proximal stent fixation of fractured coils: technical note

verfasst von: Ansgar Schütz, László Solymosi, Giles H. Vince, Martin Bendszus

Erschienen in: Neuroradiology | Ausgabe 11/2005

Einloggen, um Zugang zu erhalten

Abstract

Coil fracture represents a serious device-related complication during coil embolisation of intracranial aneurysms. If the coil cannot be retrieved completely, the loose end floating in the parent vessel can prolapse into the distal part of the vessel and may cause occlusion and brain infarction. We present a new technique in which the loose end of the fractured coil is fixed with a stent at the proximal parent vessel wall. Herniation of the loose coil end to the distal part of the vessel with potential vessel occlusion is therefore prevented. This procedure was technically feasible in all cases and no clinical complications were encountered. We suggest this new technique as a treatment option in cases of fractured coils.
Literatur
1.
Zurück zum Zitat Viñuela F, Duckwiler G, Mawad M (1997) Guglielmi detachable coil embolisation of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86:475–482PubMed Viñuela F, Duckwiler G, Mawad M (1997) Guglielmi detachable coil embolisation of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86:475–482PubMed
2.
Zurück zum Zitat Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J, Holman R (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. Lancet 360:1267–1274CrossRefPubMed Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J, Holman R (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. Lancet 360:1267–1274CrossRefPubMed
3.
Zurück zum Zitat Moret J, Cognard C, Weil A, Castaings L, Rey A (1997) Reconstruction technique in the treatment of wide-neck intracranial aneurysms: long-term angiographic and clinical results. J Neuroradiol 24:30–44PubMed Moret J, Cognard C, Weil A, Castaings L, Rey A (1997) Reconstruction technique in the treatment of wide-neck intracranial aneurysms: long-term angiographic and clinical results. J Neuroradiol 24:30–44PubMed
4.
Zurück zum Zitat Fiorella D, Albuquerque FC, Han P, McDougall CG (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–16CrossRefPubMed Fiorella D, Albuquerque FC, Han P, McDougall CG (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–16CrossRefPubMed
5.
Zurück zum Zitat Rordorf G, Bellon RJ, Budzik RF, Farkas J, Reinking GF, Pergolizzi RS, Ezzeddine M, Norbash AM, Gonzalez RG, Putman CM (2001) Silent thromboembolic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils: prospective study applying diffusion weighted imaging. AJNR Am J Neuroradiol 22:5–10PubMed Rordorf G, Bellon RJ, Budzik RF, Farkas J, Reinking GF, Pergolizzi RS, Ezzeddine M, Norbash AM, Gonzalez RG, Putman CM (2001) Silent thromboembolic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils: prospective study applying diffusion weighted imaging. AJNR Am J Neuroradiol 22:5–10PubMed
6.
Zurück zum Zitat Zoarski GH, Bear HM, Clouston JC, Ragheb J (1997) Endovascular extraction of malpositioned fibered platinum microcoils from the aneurysm sac during endovascular therapy. AJNR Am J Neuroradiol 18:691–695PubMed Zoarski GH, Bear HM, Clouston JC, Ragheb J (1997) Endovascular extraction of malpositioned fibered platinum microcoils from the aneurysm sac during endovascular therapy. AJNR Am J Neuroradiol 18:691–695PubMed
7.
Zurück zum Zitat Standard SC, Chavis TD, Wakhloo AK, Ahuja A, Guterman LR, Hopkins LN (1994) Retrieval of a Guglielmi detachable coil after unraveling and fracture: case report and experimental results. Neurosurgery 35:994–998PubMed Standard SC, Chavis TD, Wakhloo AK, Ahuja A, Guterman LR, Hopkins LN (1994) Retrieval of a Guglielmi detachable coil after unraveling and fracture: case report and experimental results. Neurosurgery 35:994–998PubMed
Metadaten
Titel
Proximal stent fixation of fractured coils: technical note
verfasst von
Ansgar Schütz
László Solymosi
Giles H. Vince
Martin Bendszus
Publikationsdatum
01.11.2005
Erschienen in
Neuroradiology / Ausgabe 11/2005
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-005-1430-4

Weitere Artikel der Ausgabe 11/2005

Neuroradiology 11/2005 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.