Skip to main content
Erschienen in: Pediatric Radiology 11/2009

01.11.2009 | Original Article

Reduced artefacts and improved assessment of hyperintense brain lesions with BLADE MR imaging in patients with neurofibromatosis type 1

verfasst von: Thekla von Kalle, Bernd Blank, Claudia Fabig-Moritz, Peter Müller-Abt, Michael Zieger, Katrin Wohlfarth, Peter Winkler

Erschienen in: Pediatric Radiology | Ausgabe 11/2009

Einloggen, um Zugang zu erhalten

Abstract

Background

Assessment of small brain lesions in children is often compromised by pulsation, flow or movement artefacts. MRI with a rotating blade-like k-space covering (BLADE, PROPELLER) can compensate for these artefacts.

Objective

We compared T2-weighted FLAIR images that were acquired with different k-space trajectories (conventional Cartesian and BLADE) to evaluate the impact of BLADE technique on the delineation of small or low-contrast brain lesions.

Materials and methods

The subject group comprised 26 children with neurofibromatosis type 1 (NF 1), who had been routinely scanned at 1.5 T for optic pathway gliomas with both techniques and who had the typical hyperintense brain lesions seen in NF 1. Four experienced radiologists retrospectively compared unlabelled 4-mm axial images with respect to the presence of artefacts, visibility of lesions, quality of contour and contrast.

Results

Both techniques were comparable in depicting hyperintense lesions as small as 2 mm independent of contrast and edge definition. Pulsation and movement artefacts were significantly less common with BLADE k-space trajectory. In 7 of 26 patients (27%), lesions and artefacts were rated as indistinguishable in conventional FLAIR, but not in BLADE FLAIR images.

Conclusion

BLADE imaging significantly improved the depiction of lesions in T2-W FLAIR images due to artefact reduction especially in the posterior fossa.
Literatur
1.
Zurück zum Zitat Forbes KP, Pipe JG, Bird CR et al (2001) PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion. J Magn Reson Imaging 14:215–222CrossRefPubMed Forbes KP, Pipe JG, Bird CR et al (2001) PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion. J Magn Reson Imaging 14:215–222CrossRefPubMed
2.
Zurück zum Zitat Penzkofer AK, Pfluger T, Pochmann Y et al (2002) MR imaging of the brain in pediatric patients: diagnostic value of HASTE sequences. AJR 179:509–514PubMed Penzkofer AK, Pfluger T, Pochmann Y et al (2002) MR imaging of the brain in pediatric patients: diagnostic value of HASTE sequences. AJR 179:509–514PubMed
3.
Zurück zum Zitat Alibek S, Adamietz B, Cavallaro A et al (2008) Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? Acad Radiol 15:986–995CrossRefPubMed Alibek S, Adamietz B, Cavallaro A et al (2008) Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? Acad Radiol 15:986–995CrossRefPubMed
4.
Zurück zum Zitat Runge VM, Wood ML, Kaufman DM et al (1988) The straight and narrow path to good head and spine MRI. Radiographics 8:507–531PubMed Runge VM, Wood ML, Kaufman DM et al (1988) The straight and narrow path to good head and spine MRI. Radiographics 8:507–531PubMed
5.
Zurück zum Zitat Kallmes DF, Hui FK, Mugler JP III (2001) Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience. Radiographics 221:251–255 Kallmes DF, Hui FK, Mugler JP III (2001) Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience. Radiographics 221:251–255
6.
Zurück zum Zitat Naganawa S, Satake H, Iwano S et al (2008) Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence. Eur Radiol 18:337–342CrossRefPubMed Naganawa S, Satake H, Iwano S et al (2008) Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence. Eur Radiol 18:337–342CrossRefPubMed
7.
Zurück zum Zitat Forbes KP, Pipe JG, Karis JP et al (2002) Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging. Radiology 225:551–555CrossRefPubMed Forbes KP, Pipe JG, Karis JP et al (2002) Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging. Radiology 225:551–555CrossRefPubMed
8.
Zurück zum Zitat Wintersperger BJ, Runge VM, Biswas J et al (2006) Brain magnetic resonance imaging at 3 Tesla using BLADE compared with standard rectilinear data sampling. Invest Radio 41:586–592CrossRef Wintersperger BJ, Runge VM, Biswas J et al (2006) Brain magnetic resonance imaging at 3 Tesla using BLADE compared with standard rectilinear data sampling. Invest Radio 41:586–592CrossRef
9.
Zurück zum Zitat Forbes KP, Pipe JG, Karis JP et al (2003) Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. AJNR 24:794–798PubMed Forbes KP, Pipe JG, Karis JP et al (2003) Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. AJNR 24:794–798PubMed
10.
Zurück zum Zitat Gill DS, Hyman SL, Steinberg A et al (2006) Age-related findings on MRI in neurofibromatosis type 1. Pediatr Radiol 36:1048–1056CrossRefPubMed Gill DS, Hyman SL, Steinberg A et al (2006) Age-related findings on MRI in neurofibromatosis type 1. Pediatr Radiol 36:1048–1056CrossRefPubMed
11.
Zurück zum Zitat Pipe JG (1999) Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 42:963–969CrossRefPubMed Pipe JG (1999) Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 42:963–969CrossRefPubMed
12.
Zurück zum Zitat Fleiss JL (1981) Statististical methods for rates and proportions, 2nd edn. Wiley, New York, p 432 Fleiss JL (1981) Statististical methods for rates and proportions, 2nd edn. Wiley, New York, p 432
13.
Zurück zum Zitat Altman DG (1991) Practical statistics for medical research, 1st edn. Chapman and Hall, London, p 404 Altman DG (1991) Practical statistics for medical research, 1st edn. Chapman and Hall, London, p 404
14.
Zurück zum Zitat Böck JC, Neumann K, Sander B et al (1991) [Prepontine artifacts due to cerebrospinal fluid pulsation in the T2-weighted coronal MR picture. Clinical significance, frequency and a technique for artefact suppression.] RoFo 154:202-205 Böck JC, Neumann K, Sander B et al (1991) [Prepontine artifacts due to cerebrospinal fluid pulsation in the T2-weighted coronal MR picture. Clinical significance, frequency and a technique for artefact suppression.] RoFo 154:202-205
15.
Zurück zum Zitat Maclaren JR, Bones PJ, Millane RP et al (2008) MRI with TRELLIS: a novel approach to motion correction. Magn Res Imaging 26:474–483CrossRef Maclaren JR, Bones PJ, Millane RP et al (2008) MRI with TRELLIS: a novel approach to motion correction. Magn Res Imaging 26:474–483CrossRef
16.
Zurück zum Zitat Iskandar BJ, Sansone JM, Medow J et al (2004) The use of quick-brain magnetic resonance imaging in the evaluation of shunt-treated hydrocephalus. J Neurosurg 101:147–151PubMed Iskandar BJ, Sansone JM, Medow J et al (2004) The use of quick-brain magnetic resonance imaging in the evaluation of shunt-treated hydrocephalus. J Neurosurg 101:147–151PubMed
17.
Zurück zum Zitat Ba-Ssalamaha A, Schick S, Heimberger K et al (2000) Ultrafast magnetic resonance imaging of the brain. Magn Reson Imaging 18:237–243CrossRefPubMed Ba-Ssalamaha A, Schick S, Heimberger K et al (2000) Ultrafast magnetic resonance imaging of the brain. Magn Reson Imaging 18:237–243CrossRefPubMed
Metadaten
Titel
Reduced artefacts and improved assessment of hyperintense brain lesions with BLADE MR imaging in patients with neurofibromatosis type 1
verfasst von
Thekla von Kalle
Bernd Blank
Claudia Fabig-Moritz
Peter Müller-Abt
Michael Zieger
Katrin Wohlfarth
Peter Winkler
Publikationsdatum
01.11.2009
Verlag
Springer-Verlag
Erschienen in
Pediatric Radiology / Ausgabe 11/2009
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-009-1370-y

Weitere Artikel der Ausgabe 11/2009

Pediatric Radiology 11/2009 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.