Skip to main content
Erschienen in: Pediatric Radiology 9/2014

01.09.2014 | Original Article

Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography

verfasst von: Johannes Boos, Patric Kröpil, Dirk Klee, Philipp Heusch, Lars Schimmöller, Jörg Schaper, Gerald Antoch, Rotem S. Lanzman

Erschienen in: Pediatric Radiology | Ausgabe 9/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Organ-specific dose reduction significantly reduces the radiation exposure of radiosensitive organs.

Objective

The purpose of this study was to assess the impact of a novel organ-specific dose reduction algorithm on image quality of pediatric chest CT.

Materials and methods

We included 28 children (mean age 10.9 ± 4.8 years, range 3–18 years) who had contrast-enhanced chest CT on a 128-row scanner. CT was performed at 100 kV using automated tube current modulation and a novel organ-specific dose-reduction algorithm (XCare™; Siemens, Forchheim, Germany). Seven children had a previous chest CT performed on a 64-row scanner at 100 kV without organ-specific dose reduction. Subjective image quality was assessed using a five-point scale (1-not diagnostic; 5-excellent). Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed in the descending aorta.

Results

Overall mean subjective image quality was 4.1 ± 0.6. In the subgroup of the seven children examined both with and without organ-specific dose reduction, subjective image quality was comparable (score 4.4 ± 0.5 with organ-specific dose reduction vs. 4.4 ± 0.7 without it; P > 0.05). There was no significant difference in mean signal-to-noise ratio and contrast-to-noise ratio with organ-specific dose reduction (38.3 ± 10.1 and 28.5 ± 8.7, respectively) and without the reduction (35.5 ± 8.5 and 26.5 ± 7.8, respectively) (P > 0.05). Volume computed tomography dose index (CTDIvol) and size-specific dose estimates did not differ significantly between acquisitions with the organ-specific dose reduction (1.7 ± 0.8 mGy) and without the reduction (1.7 ± 0.8 mGy) (P > 0.05).

Conclusion

Organ-specific dose reduction does not have an impact on image quality of pediatric chest CT and can therefore be used in clinical practice to reduce radiation dose of radiosensitive organs such as breast and thyroid gland.
Literatur
1.
Zurück zum Zitat Brenner DF, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284PubMedCrossRef Brenner DF, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284PubMedCrossRef
2.
Zurück zum Zitat National Research Council (NRC) (2006) Health risks from exposure to low levels of ionizing radiation (BEIR VII)—phase 2. The National Academies Press, Washington DC National Research Council (NRC) (2006) Health risks from exposure to low levels of ionizing radiation (BEIR VII)—phase 2. The National Academies Press, Washington DC
3.
Zurück zum Zitat Stephen AE, Segev DL, Ryan DP et al (2003) The diagnosis of acute appendicitis in a pediatric population: to CT or not to CT. J Pediatr Surg 38:367–371PubMedCrossRef Stephen AE, Segev DL, Ryan DP et al (2003) The diagnosis of acute appendicitis in a pediatric population: to CT or not to CT. J Pediatr Surg 38:367–371PubMedCrossRef
4.
Zurück zum Zitat Smyth MD, Narayan P, Tubbs RS et al (2008) Cumulative diagnostic radiation exposure in children with ventriculoperitoneal shunts: a review. Childs Nerv Syst 24:493–497PubMedCrossRef Smyth MD, Narayan P, Tubbs RS et al (2008) Cumulative diagnostic radiation exposure in children with ventriculoperitoneal shunts: a review. Childs Nerv Syst 24:493–497PubMedCrossRef
5.
Zurück zum Zitat Mandiwanza T, Saidlear C, Caird J et al (2013) The open fontanelle: a window to less radiation. Childs Nerv Syst 29:1177–1181CrossRef Mandiwanza T, Saidlear C, Caird J et al (2013) The open fontanelle: a window to less radiation. Childs Nerv Syst 29:1177–1181CrossRef
6.
Zurück zum Zitat Bernhard-Ströl C, Hachenberger C, Trugenberger-Schnabel A et al. (2012) Environmental radioactivity and radiation exposure in 2010. German Federal Ministry for the Environment, Nature Conservation, Building and Nuclear Safety. German government briefing Bernhard-Ströl C, Hachenberger C, Trugenberger-Schnabel A et al. (2012) Environmental radioactivity and radiation exposure in 2010. German Federal Ministry for the Environment, Nature Conservation, Building and Nuclear Safety. German government briefing
7.
Zurück zum Zitat Smith-Bindman R, Miglioretti DL, Johnson E et al (2012) Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996–2010. JAMA 307:2400–2409PubMedCrossRef Smith-Bindman R, Miglioretti DL, Johnson E et al (2012) Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996–2010. JAMA 307:2400–2409PubMedCrossRef
8.
Zurück zum Zitat Bakshi S, Radhakrishnan V, Sharma P et al (2012) Pediatric nonlymphoblastic non-Hodgkin lymphoma: baseline, interim, and posttreatment PET/CT versus contrast-enhanced CT for evaluation – a prospective study. Radiology 262:956–968 Bakshi S, Radhakrishnan V, Sharma P et al (2012) Pediatric nonlymphoblastic non-Hodgkin lymphoma: baseline, interim, and posttreatment PET/CT versus contrast-enhanced CT for evaluation – a prospective study. Radiology 262:956–968
9.
Zurück zum Zitat Furth C, Denecke T, Steffen I et al (2006) Correlative imaging strategies implementing CT, MRI, and PET for staging of childhood Hodgkin disease. J Pediatr Hematol Oncol 28:501–512PubMedCrossRef Furth C, Denecke T, Steffen I et al (2006) Correlative imaging strategies implementing CT, MRI, and PET for staging of childhood Hodgkin disease. J Pediatr Hematol Oncol 28:501–512PubMedCrossRef
10.
Zurück zum Zitat Szolar DH, Zebedin D, Unger B et al (1999) Radiologic staging of renal cell carcinoma. Radiologe 39:584–590PubMedCrossRef Szolar DH, Zebedin D, Unger B et al (1999) Radiologic staging of renal cell carcinoma. Radiologe 39:584–590PubMedCrossRef
11.
Zurück zum Zitat Tiddens HA (2006) Chest computed tomography scans should be considered as a routine investigaion in cystic fibrosis. Paediatr Respir Rev 7:202–208PubMed Tiddens HA (2006) Chest computed tomography scans should be considered as a routine investigaion in cystic fibrosis. Paediatr Respir Rev 7:202–208PubMed
12.
Zurück zum Zitat Strauss KJ, Goske MJ, Kaste SC et al (2010) Image Gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol 194:868–873PubMedCrossRef Strauss KJ, Goske MJ, Kaste SC et al (2010) Image Gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol 194:868–873PubMedCrossRef
13.
Zurück zum Zitat Duan X, Wang J, Christner JA et al. (2011) Dose reduction to anterior surfaces with organ-based tube-current modulation: evaluation of performance in a phantom study. AJR 197:689–695 Duan X, Wang J, Christner JA et al. (2011) Dose reduction to anterior surfaces with organ-based tube-current modulation: evaluation of performance in a phantom study. AJR 197:689–695
14.
Zurück zum Zitat Ketelsen D, Buchgeister M, Fenchel M et al (2012) Automated computed tomography dose-saving algorithm to protect radiosensitive tissues. Investig Radiol 47:148–152CrossRef Ketelsen D, Buchgeister M, Fenchel M et al (2012) Automated computed tomography dose-saving algorithm to protect radiosensitive tissues. Investig Radiol 47:148–152CrossRef
15.
Zurück zum Zitat Brady SL, Kaufman RA (2012) Investigation of Amercan Association of Physicists in Medicine report 204: size-specific dose estimates for pediatric CT implementation. Radiology 265:832–840PubMedCrossRef Brady SL, Kaufman RA (2012) Investigation of Amercan Association of Physicists in Medicine report 204: size-specific dose estimates for pediatric CT implementation. Radiology 265:832–840PubMedCrossRef
16.
Zurück zum Zitat Lee SH, Kim MJ, Yoon CS et al (2012) Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: an intra-individual comparison. Eur J Radiol 81:938–943CrossRef Lee SH, Kim MJ, Yoon CS et al (2012) Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: an intra-individual comparison. Eur J Radiol 81:938–943CrossRef
17.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–17 Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–17
19.
Zurück zum Zitat Pearce MS, Salotti JA, Little MP et al (2012) Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505PubMedCentralPubMedCrossRef Pearce MS, Salotti JA, Little MP et al (2012) Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505PubMedCentralPubMedCrossRef
21.
Zurück zum Zitat Vazquez JL, Pombar MA, Pumar JM et al (2013) Optimised low-dose multidetector CT protocol for children with cranial deformity. Eur Radiol 23:2279–2287PubMedCrossRef Vazquez JL, Pombar MA, Pumar JM et al (2013) Optimised low-dose multidetector CT protocol for children with cranial deformity. Eur Radiol 23:2279–2287PubMedCrossRef
22.
Zurück zum Zitat Eller A, May MS, Scharf M et al (2012) Attenuation-based automatic kilovolt selection in abdominal computed tomography: effects on radiation exposure and image quality. Investig Radiol 47:559–565CrossRef Eller A, May MS, Scharf M et al (2012) Attenuation-based automatic kilovolt selection in abdominal computed tomography: effects on radiation exposure and image quality. Investig Radiol 47:559–565CrossRef
23.
Zurück zum Zitat Vollmar SV, Kalender WA (2008) Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations. Eur Radiol 18:1674–1682PubMedCrossRef Vollmar SV, Kalender WA (2008) Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations. Eur Radiol 18:1674–1682PubMedCrossRef
24.
Zurück zum Zitat Kim YK, Sung YM, Choi JH et al (2013) Reduced radiation exposure of the female breast during low-dose chest CT using organ-based tube current modulation and a bismuth shield: comparison of image quality and radiation dose. AJR Am J Roentgenol 200:537–544PubMedCrossRef Kim YK, Sung YM, Choi JH et al (2013) Reduced radiation exposure of the female breast during low-dose chest CT using organ-based tube current modulation and a bismuth shield: comparison of image quality and radiation dose. AJR Am J Roentgenol 200:537–544PubMedCrossRef
25.
Zurück zum Zitat Servaes S, Zhu X (2013) The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging. Pediatr Radiol 43:1287–1294PubMedCrossRef Servaes S, Zhu X (2013) The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging. Pediatr Radiol 43:1287–1294PubMedCrossRef
26.
Zurück zum Zitat Schimmöller L, Lanzman RS, Heusch P et al (2013) Impact of organ-specific dose reduction on the image quality of head and neck CT angiography. Eur Radiol 23:1503–1509PubMedCrossRef Schimmöller L, Lanzman RS, Heusch P et al (2013) Impact of organ-specific dose reduction on the image quality of head and neck CT angiography. Eur Radiol 23:1503–1509PubMedCrossRef
27.
Zurück zum Zitat Strauss KJ, Goske MJ (2011) Estimated pediatric radiation dose during CT. Pediatr Radiol 41:S472–S482CrossRef Strauss KJ, Goske MJ (2011) Estimated pediatric radiation dose during CT. Pediatr Radiol 41:S472–S482CrossRef
28.
Zurück zum Zitat Reimann AJ, Davison C, Bjarnason T et al (2012) Organ-based computed tomographic (CT) radiation dose reduction to the lenses: impact on image quality for CT of the head. J Comput Assist Tomogr 36:334–338PubMedCrossRef Reimann AJ, Davison C, Bjarnason T et al (2012) Organ-based computed tomographic (CT) radiation dose reduction to the lenses: impact on image quality for CT of the head. J Comput Assist Tomogr 36:334–338PubMedCrossRef
29.
Zurück zum Zitat Siegel MJ, Ramirez-Giraldo JC, Holdebolt C et al (2013) Automated low-kilovoltage selection in pediatric computed tomography angiography, phantom study evaluation effects on radiation dose and image quality. Investig Radiol 48:584–589CrossRef Siegel MJ, Ramirez-Giraldo JC, Holdebolt C et al (2013) Automated low-kilovoltage selection in pediatric computed tomography angiography, phantom study evaluation effects on radiation dose and image quality. Investig Radiol 48:584–589CrossRef
30.
Zurück zum Zitat Schwarz F, Grandl K, Arnoldi A et al (2013) Lowering radiation exposure in CT angiography using automated tube potential selection and optimized iodine delivery rate. AJR Am J Roentgenol 200:W628–W634PubMedCrossRef Schwarz F, Grandl K, Arnoldi A et al (2013) Lowering radiation exposure in CT angiography using automated tube potential selection and optimized iodine delivery rate. AJR Am J Roentgenol 200:W628–W634PubMedCrossRef
Metadaten
Titel
Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
verfasst von
Johannes Boos
Patric Kröpil
Dirk Klee
Philipp Heusch
Lars Schimmöller
Jörg Schaper
Gerald Antoch
Rotem S. Lanzman
Publikationsdatum
01.09.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 9/2014
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-014-2950-z

Weitere Artikel der Ausgabe 9/2014

Pediatric Radiology 9/2014 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.