Skip to main content
Erschienen in: Skeletal Radiology 9/2014

01.09.2014 | Scientific Article

Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures

verfasst von: Pedro Augusto Gondim Teixeira, Jean-Baptiste Meyer, Cedric Baumann, Ariane Raymond, François Sirveaux, Henry Coudane, Alain Blum

Erschienen in: Skeletal Radiology | Ausgabe 9/2014

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To compare the image quality of CT with iterative reconstruction alone and in association with projection-based single-energy metal artifact reduction (SEMAR) for the visualization of specific periarticular soft tissue structures in patients with hip prostheses.

Methods

CT studies from 48 consecutive patients with a hip prosthesis (24 unilateral and 24 bilateral) were retrospectively reconstructed using two different methods: iterative reconstruction (IR) alone and IR associated with SEMAR. The influence of metallic artifacts on the identification of various periarticular structures was evaluated subjectively by two readers. The image quality was compared in patients with unilateral and bilateral prostheses.

Results

Visualization of periprosthetic soft tissue was significantly improved by the SEMAR algorithm (p < 0.0001). When SEMAR was associated with IR, the gluteus minimus and medius tendons, obturator internus muscle, prostate/uterus and bladder could be seen with medium or high confidence. There were no significant differences in image quality between patients with unilateral or bilateral prosthesis when SEMAR was used (p > 0.2). This algorithm increased the detection of periarticular masses by 30 %.

Conclusion

SEMAR significantly improves the image quality of periarticular soft-tissue structures in patients with hip prostheses.
Literatur
2.
Zurück zum Zitat Roth TD, Maertz NA, Parr JA, Buckwalter KA, Choplin RH. CT of the hip prosthesis: appearance of components, fixation, and complications. Radiogr Rev Publ Radiol Soc North Am Inc. 2012;32:1089–107. Roth TD, Maertz NA, Parr JA, Buckwalter KA, Choplin RH. CT of the hip prosthesis: appearance of components, fixation, and complications. Radiogr Rev Publ Radiol Soc North Am Inc. 2012;32:1089–107.
3.
Zurück zum Zitat Cahir JG, Toms AP, Marshall TJ, Wimhurst J, Nolan J. CT and MRI of hip arthroplasty. Clin Radiol. 2007;62:1163–71. discussion 1172–1173.PubMedCrossRef Cahir JG, Toms AP, Marshall TJ, Wimhurst J, Nolan J. CT and MRI of hip arthroplasty. Clin Radiol. 2007;62:1163–71. discussion 1172–1173.PubMedCrossRef
4.
Zurück zum Zitat Choplin RH, Henley CN, Edds EM, Capello W, Rankin JL, Buckwalter KA. Total hip arthroplasty in patients with bone deficiency of the acetabulum. Radiogr Rev Publ Radiol Soc North Am Inc. 2008;28:771–86. Choplin RH, Henley CN, Edds EM, Capello W, Rankin JL, Buckwalter KA. Total hip arthroplasty in patients with bone deficiency of the acetabulum. Radiogr Rev Publ Radiol Soc North Am Inc. 2008;28:771–86.
5.
Zurück zum Zitat Bremer AK, Kalberer F, Pfirrmann CWA, Dora C. Soft-tissue changes in hip abductor muscles and tendons after total hip replacement: comparison between the direct anterior and the transgluteal approaches. J Bone Joint Surg (Br). 2011;93:886–9.CrossRef Bremer AK, Kalberer F, Pfirrmann CWA, Dora C. Soft-tissue changes in hip abductor muscles and tendons after total hip replacement: comparison between the direct anterior and the transgluteal approaches. J Bone Joint Surg (Br). 2011;93:886–9.CrossRef
6.
Zurück zum Zitat Henderson RA, Lachiewicz PF. Groin pain after replacement of the hip: aetiology, evaluation and treatment. J Bone Joint Surg (Br). 2012;94:145–51.CrossRef Henderson RA, Lachiewicz PF. Groin pain after replacement of the hip: aetiology, evaluation and treatment. J Bone Joint Surg (Br). 2012;94:145–51.CrossRef
7.
Zurück zum Zitat Park JH, Hozack B, Kim P, Norton R, Mandel S, Restrepo C, et al. Common peroneal nerve palsy following total hip arthroplasty: prognostic factors for recovery. J Bone Joint Surg Am. 2013;95:e551–5.PubMedCrossRef Park JH, Hozack B, Kim P, Norton R, Mandel S, Restrepo C, et al. Common peroneal nerve palsy following total hip arthroplasty: prognostic factors for recovery. J Bone Joint Surg Am. 2013;95:e551–5.PubMedCrossRef
8.
Zurück zum Zitat Douis H, Dunlop DJ, Pearson AM, O’Hara JN, James SLJ. The role of ultrasound in the assessment of post-operative complications following hip arthroplasty. Skeletal Radiol. 2012;41:1035–46.PubMedCrossRef Douis H, Dunlop DJ, Pearson AM, O’Hara JN, James SLJ. The role of ultrasound in the assessment of post-operative complications following hip arthroplasty. Skeletal Radiol. 2012;41:1035–46.PubMedCrossRef
9.
Zurück zum Zitat Long SS, Surrey D, Nazarian LN. Common sonographic findings in the painful hip after hip arthroplasty. J Ultrasound Med Off J Am Inst Ultrasound Med. 2012;31:301–12. Long SS, Surrey D, Nazarian LN. Common sonographic findings in the painful hip after hip arthroplasty. J Ultrasound Med Off J Am Inst Ultrasound Med. 2012;31:301–12.
10.
Zurück zum Zitat Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants. Radiology. 1987;164:576–7.PubMedCrossRef Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants. Radiology. 1987;164:576–7.PubMedCrossRef
11.
Zurück zum Zitat Morsbach F, Bickelhaupt S, Wanner GA, Krauss A, Schmidt B, Alkadhi H. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions. Radiology. 2013;268:237–44.PubMedCrossRef Morsbach F, Bickelhaupt S, Wanner GA, Krauss A, Schmidt B, Alkadhi H. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions. Radiology. 2013;268:237–44.PubMedCrossRef
12.
Zurück zum Zitat Lee YH, Park KK, Song H-T, Kim S, Suh J-S. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software. Eur Radiol. 2012;22:1331–40.PubMedCrossRef Lee YH, Park KK, Song H-T, Kim S, Suh J-S. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software. Eur Radiol. 2012;22:1331–40.PubMedCrossRef
13.
Zurück zum Zitat Yu L, Leng S, McCollough CH. Dual-energy CT-based monochromatic imaging. AJR Am J Roentgenol. 2012;199:S9–15.PubMedCrossRef Yu L, Leng S, McCollough CH. Dual-energy CT-based monochromatic imaging. AJR Am J Roentgenol. 2012;199:S9–15.PubMedCrossRef
14.
Zurück zum Zitat Brook OR, Gourtsoyianni S, Brook A, Mahadevan A, Wilcox C, Raptopoulos V. Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers. Radiology. 2012;263:696–705.PubMedCrossRef Brook OR, Gourtsoyianni S, Brook A, Mahadevan A, Wilcox C, Raptopoulos V. Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers. Radiology. 2012;263:696–705.PubMedCrossRef
15.
Zurück zum Zitat Yang Z, Silver MD, Noshi Y. Effective Data-domain Noise and Streak Reduction for X-Ray CT. 11th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, Potsdam, Germany; 2011. Yang Z, Silver MD, Noshi Y. Effective Data-domain Noise and Streak Reduction for X-Ray CT. 11th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, Potsdam, Germany; 2011.
16.
Zurück zum Zitat Yang Z, Zamyatin A, Akino N. Adaptive Weighted Anisotropic Diffusion For Computed Tomography Denoising. 11 th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, Potsdam, Germany; 2011. Yang Z, Zamyatin A, Akino N. Adaptive Weighted Anisotropic Diffusion For Computed Tomography Denoising. 11 th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, Potsdam, Germany; 2011.
17.
Zurück zum Zitat Chang Y-B, Xu D, Zamyatin A. Metal Artifact Reduction Algorithm for Single Energy and Dual Energy CT scans. 2012 I.E. Nucl. Sci. Symp. Med. Imaging Conf. Rec. 16/112012;3426–9. Chang Y-B, Xu D, Zamyatin A. Metal Artifact Reduction Algorithm for Single Energy and Dual Energy CT scans. 2012 I.E. Nucl. Sci. Symp. Med. Imaging Conf. Rec. 16/112012;3426–9.
18.
Zurück zum Zitat Bal M, Spies L. Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Med Phys. 2006;33:2852–9.PubMedCrossRef Bal M, Spies L. Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Med Phys. 2006;33:2852–9.PubMedCrossRef
19.
Zurück zum Zitat Joseph PM. An improved algorithm for re projecting rays through pixel images. IEEE Trans Med Imaging. 1982;1:192–6.PubMedCrossRef Joseph PM. An improved algorithm for re projecting rays through pixel images. IEEE Trans Med Imaging. 1982;1:192–6.PubMedCrossRef
20.
Zurück zum Zitat Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN. Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am. 2009;91:1882–9.PubMedCrossRef Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN. Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am. 2009;91:1882–9.PubMedCrossRef
21.
Zurück zum Zitat Gervaise A, Osemont B, Lecocq S, Noel A, Micard E, Felblinger J, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT. Eur Radiol. 2012;22:295–301.PubMedCrossRef Gervaise A, Osemont B, Lecocq S, Noel A, Micard E, Felblinger J, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT. Eur Radiol. 2012;22:295–301.PubMedCrossRef
22.
Zurück zum Zitat Lee YH, Park KK, Song H-T, Kim S, Suh J-S. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software. Eur Radiol. 2012;22:1331–40.PubMedCrossRef Lee YH, Park KK, Song H-T, Kim S, Suh J-S. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software. Eur Radiol. 2012;22:1331–40.PubMedCrossRef
23.
Zurück zum Zitat Malan DF, Botha CP, Kraaij G, Joemai RMS, van der Heide HJL, Nelissen RGHH, et al. Measuring femoral lesions despite CT metal artefacts: a cadaveric study. Skeletal Radiol. 2012;41:547–55.PubMedCentralPubMedCrossRef Malan DF, Botha CP, Kraaij G, Joemai RMS, van der Heide HJL, Nelissen RGHH, et al. Measuring femoral lesions despite CT metal artefacts: a cadaveric study. Skeletal Radiol. 2012;41:547–55.PubMedCentralPubMedCrossRef
24.
Zurück zum Zitat Verburg JM, Seco J. CT metal artifact reduction method correcting for beam hardening and missing projections. Phys Med Biol. 2012;57:2803–18.PubMedCrossRef Verburg JM, Seco J. CT metal artifact reduction method correcting for beam hardening and missing projections. Phys Med Biol. 2012;57:2803–18.PubMedCrossRef
25.
Zurück zum Zitat Yu L, Li H, Mueller J, Kofler JM, Liu X, Primak AN, et al. Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results. Invest Radiol. 2009;44:691–6.PubMedCentralPubMedCrossRef Yu L, Li H, Mueller J, Kofler JM, Liu X, Primak AN, et al. Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results. Invest Radiol. 2009;44:691–6.PubMedCentralPubMedCrossRef
26.
Zurück zum Zitat Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys. 2011;38:6371–9.PubMedCentralPubMedCrossRef Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys. 2011;38:6371–9.PubMedCentralPubMedCrossRef
27.
Zurück zum Zitat Vrtiska TJ, Takahashi N, Fletcher JG, Hartman RP, Yu L, Kawashima A. Genitourinary applications of dual-energy CT. AJR Am J Roentgenol. 2010;194:1434–42.PubMedCrossRef Vrtiska TJ, Takahashi N, Fletcher JG, Hartman RP, Yu L, Kawashima A. Genitourinary applications of dual-energy CT. AJR Am J Roentgenol. 2010;194:1434–42.PubMedCrossRef
Metadaten
Titel
Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures
verfasst von
Pedro Augusto Gondim Teixeira
Jean-Baptiste Meyer
Cedric Baumann
Ariane Raymond
François Sirveaux
Henry Coudane
Alain Blum
Publikationsdatum
01.09.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Skeletal Radiology / Ausgabe 9/2014
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-014-1923-5

Weitere Artikel der Ausgabe 9/2014

Skeletal Radiology 9/2014 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.