Skip to main content
Erschienen in: Abdominal Radiology 11/2017

31.05.2017

Measurement of liver and spleen interstitial volume in patients with systemic amyloid light-chain amyloidosis using equilibrium contrast CT

verfasst von: Jason Yeung, S. Sivarajan, T. A. Treibel, S. Rosmini, M. Fontana, J. D. Gillmore, P. N. Hawkins, S. Punwani, J. C. Moon, S. A. Taylor, S. Bandula

Erschienen in: Abdominal Radiology | Ausgabe 11/2017

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To investigate equilibrium contrast-enhanced CT (EQ-CT) measurement of extracellular volume fraction (ECV) in patients with systemic amyloid light-chain (AL) amyloidosis, testing the hypothesis that ECV becomes elevated in the liver and spleen and ECV correlates with other estimates of organ amyloid burden.

Methods

26 patients with AL amyloidosis underwent EQ-CT, and ECV was measured in the liver and spleen. Patients also underwent serum amyloid P (SAP) component scintigraphy with grading of liver and spleen involvement. Mann–Whitney U test was used to test for a difference between patients with amyloid deposition (SAP grade 1–3) and those without (SAP grade 0). Variation in ECV across SAP grades was assessed using the Kruskal–Wallis test and association between ECV and SAP grades with Spearman correlation.

Results

Mean ECV in the spleen and liver was significantly greater (p < 0.0005) in amyloidotic organs (SAP grade 1–3) [spleen, liver: 0.430, 0.375] compared with healthy tissues [spleen, liver: 0.304, 0.269]. ECV increased with increasing amyloid burden, showing positive correlation with SAP grade in both the liver (r = 0.758) and spleen (r = 0.867).

Conclusion

In patients with systemic AL amyloidosis, EQ-CT can demonstrate increased spleen and liver ECV, which is associated with amyloid disease burden.
Literatur
1.
Zurück zum Zitat Gillmore JD, Hawkins PN (2013) Pathophysiology and treatment of systemic amyloidosis. Nat Rev Nephrol 9(10):574–586CrossRefPubMed Gillmore JD, Hawkins PN (2013) Pathophysiology and treatment of systemic amyloidosis. Nat Rev Nephrol 9(10):574–586CrossRefPubMed
2.
Zurück zum Zitat Sattianavagam PT, Hawkins PN, Gillmore JD (2009) Systemic amyloidosis and the gastrointestinal tract. Nat Rev Gastroenterol Hepatol 6(10):608–617CrossRef Sattianavagam PT, Hawkins PN, Gillmore JD (2009) Systemic amyloidosis and the gastrointestinal tract. Nat Rev Gastroenterol Hepatol 6(10):608–617CrossRef
3.
Zurück zum Zitat Lovat LB, Persey MR, Madhoo S, Pepys MB, Hawkins P (1998) The liver in systemic amyloidosis: insights from 123I serum amyloid P component scintigraphy in 484 patients. Gut 42(5):727–734CrossRefPubMedPubMedCentral Lovat LB, Persey MR, Madhoo S, Pepys MB, Hawkins P (1998) The liver in systemic amyloidosis: insights from 123I serum amyloid P component scintigraphy in 484 patients. Gut 42(5):727–734CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Monzawa S, Tsukamoto T, Omata K, et al. (2002) A Case with primary amyloidosis of the liver and spleen: radiologic findings. Eur J Radiol 41(3):237–241CrossRefPubMed Monzawa S, Tsukamoto T, Omata K, et al. (2002) A Case with primary amyloidosis of the liver and spleen: radiologic findings. Eur J Radiol 41(3):237–241CrossRefPubMed
5.
Zurück zum Zitat Sachchithanantham S, Wechalekar AD (2013) Imaging in systemic amyloidosis. Br Med Bull 107(1):41–56CrossRefPubMed Sachchithanantham S, Wechalekar AD (2013) Imaging in systemic amyloidosis. Br Med Bull 107(1):41–56CrossRefPubMed
6.
Zurück zum Zitat Georgiades CS, Neyman EG, Barish MA, Fishman EK (2004) Amyloidosis: review and CT manifestations. Radiographics 24(2):405–416CrossRefPubMed Georgiades CS, Neyman EG, Barish MA, Fishman EK (2004) Amyloidosis: review and CT manifestations. Radiographics 24(2):405–416CrossRefPubMed
7.
Zurück zum Zitat Bandula S, White SJ, Flett AS, et al. (2013) Measurement of myocardial extracellular volume fraction by using equilibrium contrast-enhanced CT: validation against histologic findings. Radiology 269(2):396–403CrossRefPubMed Bandula S, White SJ, Flett AS, et al. (2013) Measurement of myocardial extracellular volume fraction by using equilibrium contrast-enhanced CT: validation against histologic findings. Radiology 269(2):396–403CrossRefPubMed
8.
Zurück zum Zitat Banypersad SM, Sado DM, Flett AS, et al. (2013) Quantification of myocardial extracellular volume fraction in systemic AL amyloidosis: an equilibrium contrast cardiovascular magnetic resonance study. Circulation 6(1):34–39PubMed Banypersad SM, Sado DM, Flett AS, et al. (2013) Quantification of myocardial extracellular volume fraction in systemic AL amyloidosis: an equilibrium contrast cardiovascular magnetic resonance study. Circulation 6(1):34–39PubMed
9.
Zurück zum Zitat Treibel TA, Bandula S, Fontana M, et al. (2015) Extracellular volume quantification by dynamic equilibrium cardiac computed tomography in cardiac amyloidosis. J Cardiovasc Comput Tomogr 9(6):585–592CrossRefPubMedPubMedCentral Treibel TA, Bandula S, Fontana M, et al. (2015) Extracellular volume quantification by dynamic equilibrium cardiac computed tomography in cardiac amyloidosis. J Cardiovasc Comput Tomogr 9(6):585–592CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Bandula S, Punwani S, Rosenberg WM, et al. (2015) Equilibrium contrast-enhanced CT imaging to evaluate hepatic fibrosis: initial validation by comparison with histopathologic sampling. Radiology 275(1):136–143CrossRefPubMed Bandula S, Punwani S, Rosenberg WM, et al. (2015) Equilibrium contrast-enhanced CT imaging to evaluate hepatic fibrosis: initial validation by comparison with histopathologic sampling. Radiology 275(1):136–143CrossRefPubMed
11.
12.
Zurück zum Zitat Zissen MH, Wang ZJ, Yee J, et al. (2013) Contrast-enhanced CT quantification of hepatic fractional extraceullar space: correlation with diffuse liver disease severity. Am J Roentgenol 201(6):1204–1210CrossRef Zissen MH, Wang ZJ, Yee J, et al. (2013) Contrast-enhanced CT quantification of hepatic fractional extraceullar space: correlation with diffuse liver disease severity. Am J Roentgenol 201(6):1204–1210CrossRef
13.
Zurück zum Zitat Yoon JH, Lee JM, Klotz E, et al. (2015) Estimation of hepatic extracellular volume fraction using multiphasic liver computed tomography for hepatic fibrosis grading. Invest Radiol 50(4):290–296CrossRefPubMed Yoon JH, Lee JM, Klotz E, et al. (2015) Estimation of hepatic extracellular volume fraction using multiphasic liver computed tomography for hepatic fibrosis grading. Invest Radiol 50(4):290–296CrossRefPubMed
14.
Zurück zum Zitat Bandula S, Banypersad SM, Sado DM, et al. (2013) Measurement of tissue interstitial volume in healthy patients and those with amyloidosis with equilibrium contrast-enhanced MR imaging. Radiology 268(3):858–864CrossRefPubMed Bandula S, Banypersad SM, Sado DM, et al. (2013) Measurement of tissue interstitial volume in healthy patients and those with amyloidosis with equilibrium contrast-enhanced MR imaging. Radiology 268(3):858–864CrossRefPubMed
15.
Zurück zum Zitat Hawkins PN, Lavender JP, Pepys MB (1990) Evaluation of systemic amyloidosis by scintigraphy with 123 I-labelled serum amyloid P component. N Engl J Med 25(7):709–713 Hawkins PN, Lavender JP, Pepys MB (1990) Evaluation of systemic amyloidosis by scintigraphy with 123 I-labelled serum amyloid P component. N Engl J Med 25(7):709–713
16.
Zurück zum Zitat Rydh A, Suhr O, Hietala SO, et al. (1998) Serum amyloid P component scintigraphy in familial amyloid polyneuropathy: regression of visceral amyloid following liver transplantation. Eur J Nucl Med 25(7):2197–2215 Rydh A, Suhr O, Hietala SO, et al. (1998) Serum amyloid P component scintigraphy in familial amyloid polyneuropathy: regression of visceral amyloid following liver transplantation. Eur J Nucl Med 25(7):2197–2215
17.
Zurück zum Zitat Hazenburg BP, van Rijswijk MH, Piers DA, et al. (2006) Diagnostic performance of 123I-labeled serum amyloid P component scintigraphy in patients with amyloidosis. Am J Med 119(4):355 Hazenburg BP, van Rijswijk MH, Piers DA, et al. (2006) Diagnostic performance of 123I-labeled serum amyloid P component scintigraphy in patients with amyloidosis. Am J Med 119(4):355
18.
Zurück zum Zitat White SK, Sado DM, Fontana M, et al. (2013) T1 mapping for myocardial extracellular volume measurement by CMR: bolus only versus primed infusion technique. JACC Cardiovasc Imaging 6(9):955–962CrossRefPubMed White SK, Sado DM, Fontana M, et al. (2013) T1 mapping for myocardial extracellular volume measurement by CMR: bolus only versus primed infusion technique. JACC Cardiovasc Imaging 6(9):955–962CrossRefPubMed
19.
Zurück zum Zitat Chen B, Marin D, Richard S, et al. (2013) Precision of iodine quantification in hepatic CT: effects of iterative reconstruction with various imaging parameters. Am J Roentgenol. 200(5):W475–W482CrossRef Chen B, Marin D, Richard S, et al. (2013) Precision of iodine quantification in hepatic CT: effects of iterative reconstruction with various imaging parameters. Am J Roentgenol. 200(5):W475–W482CrossRef
20.
Zurück zum Zitat Shuman WP, Green DE, Busey JM, et al. (2013) Model-based Iterative reconstruction versus adaptive statistical iterative reconstruction and filtered back projection in liver 64-MDCT: focal lesion detection, lesion conspicuity and image noise. AM J Roentgenol 200(5):1071–1076CrossRef Shuman WP, Green DE, Busey JM, et al. (2013) Model-based Iterative reconstruction versus adaptive statistical iterative reconstruction and filtered back projection in liver 64-MDCT: focal lesion detection, lesion conspicuity and image noise. AM J Roentgenol 200(5):1071–1076CrossRef
21.
Zurück zum Zitat Kase KR, Strom DJ, Thomadsen BR, Suleiman OH, Quinn DM, Miller KL (2009) National Council on Radiation Protection Report no. 160, Ionizing Radiation Exposure of the Population of the United States. National Council on Radiation Protection and Measurements Kase KR, Strom DJ, Thomadsen BR, Suleiman OH, Quinn DM, Miller KL (2009) National Council on Radiation Protection Report no. 160, Ionizing Radiation Exposure of the Population of the United States. National Council on Radiation Protection and Measurements
Metadaten
Titel
Measurement of liver and spleen interstitial volume in patients with systemic amyloid light-chain amyloidosis using equilibrium contrast CT
verfasst von
Jason Yeung
S. Sivarajan
T. A. Treibel
S. Rosmini
M. Fontana
J. D. Gillmore
P. N. Hawkins
S. Punwani
J. C. Moon
S. A. Taylor
S. Bandula
Publikationsdatum
31.05.2017
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 11/2017
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-017-1194-4

Weitere Artikel der Ausgabe 11/2017

Abdominal Radiology 11/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.