Recently it was shown that the design changes from the ABG-I to ABG-II hip stem resulted in a better, although not significant, proximal bone preservation. Our hypothesis was that by matching patients for preoperative bone quality, statistical power would increase and that the trend of better proximal bone preservation in ABG-II might become significant. Twenty-four ABG-II patients were compared to two different ABG-I groups: (1) 25 patients from our earlier prospective study and (2) a group of 24 patients selected to perfectly match the ABG-II group regarding gender, age and preoperative bone quality. Postoperative changes in periprosthetic bone mineral density (BMD) were quantified at 2 years postoperatively using DEXA scanning. Bone preservation (less BMD loss) was better for the ABG-II than the ABG-I (all two groups) in the proximal zones 1 and 7. In Gruen zone 7, a statistically significant difference was found for group B (p = 0.03). By matching patients for preoperative bone quality and gender, a statistical significant difference was found in proximal bone preservation in favour of ABG-II. In future comparative bone remodelling studies using DEXA, patients should be matched for preoperative bone quality and gender.
Literatur
1.
2.
Zurück zum Zitat Bhandari M, Bajammal S, Guyatt GH, Griffith L, Busse JW, Schunemann H, Einhorn TA (2005) Effect of bisphosphonates on periprosthetic bone mineral density after total joint arthroplasty: a meta-analysis. J Bone Jt Surg, Am Vol 87:293–301CrossRef Bhandari M, Bajammal S, Guyatt GH, Griffith L, Busse JW, Schunemann H, Einhorn TA (2005) Effect of bisphosphonates on periprosthetic bone mineral density after total joint arthroplasty: a meta-analysis. J Bone Jt Surg, Am Vol 87:293–301CrossRef
3.
Zurück zum Zitat Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding: laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 274:79–96PubMed Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding: laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 274:79–96PubMed
4.
Zurück zum Zitat Coathup MJ, Blackburn J, Goodship AE, Cunningham JL, Smith T, Blunn GW (2005) Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components. Biomaterials 26:4161–9PubMedCrossRef Coathup MJ, Blackburn J, Goodship AE, Cunningham JL, Smith T, Blunn GW (2005) Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components. Biomaterials 26:4161–9PubMedCrossRef
5.
Zurück zum Zitat Engh CA, McGovern TF, Bobyn JD, Harris WH (1992) A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Jt Surg, Am Vol 74:1009–20 Engh CA, McGovern TF, Bobyn JD, Harris WH (1992) A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Jt Surg, Am Vol 74:1009–20
6.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res:17–27 Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res:17–27
7.
Zurück zum Zitat Herrera A, Canales V, Anderson J, Garcia-Araujo C, Murcia-Mazon A, Tonino AJ (2004) Seven to 10 years followup of an anatomic hip prosthesis: an international study. Clin Orthop Relat Res:129–37 Herrera A, Canales V, Anderson J, Garcia-Araujo C, Murcia-Mazon A, Tonino AJ (2004) Seven to 10 years followup of an anatomic hip prosthesis: an international study. Clin Orthop Relat Res:129–37
8.
Zurück zum Zitat Mulliken BD, Bourne RB, Rorabeck CH, Nayak N (1996) A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: radiographic evaluation and stability. J Bone Jt Surg, Am Vol 78:1214–25 Mulliken BD, Bourne RB, Rorabeck CH, Nayak N (1996) A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: radiographic evaluation and stability. J Bone Jt Surg, Am Vol 78:1214–25
9.
Zurück zum Zitat Munting E (1996) The contributions and limitations of hydroxyapatite coatings to implant fixation: a histomorphometric study of load bearing implants in dogs. Int Orthop 20:1–6PubMedCrossRef Munting E (1996) The contributions and limitations of hydroxyapatite coatings to implant fixation: a histomorphometric study of load bearing implants in dogs. Int Orthop 20:1–6PubMedCrossRef
10.
Zurück zum Zitat Oosterbos CJ, Rahmy AI, Tonino AJ, Witpeerd W (2004) High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10 years. Acta Orthop Scand 75:127–33PubMedCrossRef Oosterbos CJ, Rahmy AI, Tonino AJ, Witpeerd W (2004) High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10 years. Acta Orthop Scand 75:127–33PubMedCrossRef
11.
Zurück zum Zitat Rahmy A, Tonino AJ, Tan W, ter Riet G (2000) Precision of dual energy X-ray absorptiometry in determining periprosthetic bone mineral density of the hydroxyapatite coated hip prosthesis. Hip Int 10:83–90 Rahmy A, Tonino AJ, Tan W, ter Riet G (2000) Precision of dual energy X-ray absorptiometry in determining periprosthetic bone mineral density of the hydroxyapatite coated hip prosthesis. Hip Int 10:83–90
12.
Zurück zum Zitat Rahmy AI, Gosens T, Blake GM, Tonino A, Fogelman I (2004) Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss. Osteoporos Int 15:281–9PubMedCrossRef Rahmy AI, Gosens T, Blake GM, Tonino A, Fogelman I (2004) Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss. Osteoporos Int 15:281–9PubMedCrossRef
13.
Zurück zum Zitat Rosenthall L, Bobyn JD, Tanzer M (1999) Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling. Int Orthop 23:325–9PubMedCrossRef Rosenthall L, Bobyn JD, Tanzer M (1999) Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling. Int Orthop 23:325–9PubMedCrossRef
14.
Zurück zum Zitat Rossi P, Sibelli P, Fumero S, Crua E (1995) Short-term results of hydroxyapatite-coated primary total hip arthroplasty. Clin Orthop Relat Res:98–102 Rossi P, Sibelli P, Fumero S, Crua E (1995) Short-term results of hydroxyapatite-coated primary total hip arthroplasty. Clin Orthop Relat Res:98–102
15.
Zurück zum Zitat Theis JC, Beadel G (2003) Changes in proximal femoral bone mineral density around a hydroxyapatite-coated hip joint arthroplasty. J Orthop Surg (Hong Kong) 11:48–52 Theis JC, Beadel G (2003) Changes in proximal femoral bone mineral density around a hydroxyapatite-coated hip joint arthroplasty. J Orthop Surg (Hong Kong) 11:48–52
16.
Zurück zum Zitat Tonino AJ, Rahmy AI (2000) The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study: The International ABG Study Group. J Arthroplast 15:274–82CrossRef Tonino AJ, Rahmy AI (2000) The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study: The International ABG Study Group. J Arthroplast 15:274–82CrossRef
17.
Zurück zum Zitat Tonino AJ, Therin M, Doyle C (1999) Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem. J Bone Jt Surg, Br Vol 81:148–54CrossRef Tonino AJ, Therin M, Doyle C (1999) Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem. J Bone Jt Surg, Br Vol 81:148–54CrossRef
18.
Zurück zum Zitat van der Wal BC, Rahmy AIA, Grimm B, Blake GM, Heyligers IC, Tonino AJ (2006) The influence of implant design on periprosthetic bone remodelling of two types of uncemented HA-coated hip stems: a two-year follow-up study using DEXA. Hip Int 16:8–17 van der Wal BC, Rahmy AIA, Grimm B, Blake GM, Heyligers IC, Tonino AJ (2006) The influence of implant design on periprosthetic bone remodelling of two types of uncemented HA-coated hip stems: a two-year follow-up study using DEXA. Hip Int 16:8–17
19.
Zurück zum Zitat van der Wal BC, Vischjager M, Grimm B, Heyligers IC, Tonino AJ (2005) Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems. Int Orthop 29:235–40PubMedCrossRef van der Wal BC, Vischjager M, Grimm B, Heyligers IC, Tonino AJ (2005) Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems. Int Orthop 29:235–40PubMedCrossRef
20.
Zurück zum Zitat Venesmaa PK, Kroger HP, Jurvelin JS, Miettinen HJ, Suomalainen OT, Alhava EM (2003) Periprosthetic bone loss after cemented total hip arthroplasty: a prospective 5-year dual energy radiographic absorptiometry study of 15 patients. Acta Orthop Scand 74:31–6PubMedCrossRef Venesmaa PK, Kroger HP, Jurvelin JS, Miettinen HJ, Suomalainen OT, Alhava EM (2003) Periprosthetic bone loss after cemented total hip arthroplasty: a prospective 5-year dual energy radiographic absorptiometry study of 15 patients. Acta Orthop Scand 74:31–6PubMedCrossRef
21.
Zurück zum Zitat Wan Z, Dorr LD (1996) Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant. J Arthroplast 11:718–25CrossRef Wan Z, Dorr LD (1996) Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant. J Arthroplast 11:718–25CrossRef
22.
Zurück zum Zitat Wick M, Lester DK (2004) Radiological changes in second- and third-generation Zweymuller stems. J Bone Jt Surg, Br Vol 86:1108–14CrossRef Wick M, Lester DK (2004) Radiological changes in second- and third-generation Zweymuller stems. J Bone Jt Surg, Br Vol 86:1108–14CrossRef
23.
Zurück zum Zitat Wixson RL, Stulberg SD, Van Flandern GJ, Puri L (1997) Maintenance of proximal bone mass with an uncemented femoral stem analysis with dual-energy x-ray absorptiometry. J Arthroplast 12:365–72CrossRef Wixson RL, Stulberg SD, Van Flandern GJ, Puri L (1997) Maintenance of proximal bone mass with an uncemented femoral stem analysis with dual-energy x-ray absorptiometry. J Arthroplast 12:365–72CrossRef
Metadaten
Titel
Preoperative bone quality as a factor in dual-energy X-ray absorptiometry analysis comparing bone remodelling between two implant types
verfasst von
Bart Cornelis Hendrikus van der Wal
Ali Rahmy
Bernd Grimm
Ide Heyligers
Alphons Tonino
Publikationsdatum
01.02.2008
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 1/2008
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0279-4

Weitere Artikel der Ausgabe 1/2008

International Orthopaedics 1/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.