Skip to main content
Erschienen in: Aesthetic Plastic Surgery 5/2012

01.10.2012 | Original Article

Measuring Volumetric Change After Augmentation Mammaplasty Using a Three-Dimensional Scanning Technique: An Innovative Method

verfasst von: Chunjun Liu, Jie Luan, Kai Ji, Jingjing Sun

Erschienen in: Aesthetic Plastic Surgery | Ausgabe 5/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

Measurement of volumetric change after augmentation mammaplasty is of great significance to plastic surgeons. This study aimed to introduce a new method using a three-dimensional (3D) scanning technique to measure volumetric change after augmentation mammaplasty.

Methods

Preoperative 3D scans of 10 breasts were included in the study. A simulated postoperative breast scan was constructed using software. The true value of volumetric change was calculated. Volumetric change was measured and repeated 10 times by the traditional method and the new method. One investigator used the traditional method, and two investigators used the new method. The difference from the true value between the two methods and the intraclass coefficient (ICC) for each method was evaluated. Comparison of agreement with the true value and comparison of agreement using the new method between the two investigators were made using a Bland–Altman analysis.

Results

The mean breast volumetric change was 256.1 ± 61.1 ml for the new method, 281.9 ± 73.7 ml for the traditional method, and 256.0 ± 61.0 ml for the true value. The difference from the true value for the traditional method was significantly greater than for the new method. The ICC was 0.9999 for the new method and 0.993 for the traditional method. Bland–Altman analysis showed a 95 % confidence interval (CI) of −40.9 to 92.7 ml for the traditional method and −0.9 to 1.2 ml for the new method. Comparison of agreement between investigators 1 and 2 showed a 95 % CI of −0.9 to 1.0 ml. The limits of agreement were ±1.0 ml.

Conclusions

The proposed new method can provide excellent accuracy, repeatability, and reproducibility in measuring volumetric change after augmentation mammaplasty using a 3D scanning technique.

Level of Evidence I

This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.​springer.​com/​00266.
Literatur
1.
Zurück zum Zitat Galdino GM, Nahabedian M, Chiaramonte M et al (2002) Clinical applications of three-dimensional photography in breast surgery. Plast Reconstr Surg 110:58–70PubMedCrossRef Galdino GM, Nahabedian M, Chiaramonte M et al (2002) Clinical applications of three-dimensional photography in breast surgery. Plast Reconstr Surg 110:58–70PubMedCrossRef
2.
Zurück zum Zitat Losken A, Seify H, Denson DD et al (2005) Validating three-dimensional imaging of the breast. Ann Plast Surg 54:471–476PubMedCrossRef Losken A, Seify H, Denson DD et al (2005) Validating three-dimensional imaging of the breast. Ann Plast Surg 54:471–476PubMedCrossRef
3.
Zurück zum Zitat Tepper OM, Small K, Rudolph L et al (2006) Virtual 3-dimensional modeling as a valuable adjunct to aesthetic and reconstructive breast surgery. Am J Surg 192:548–551PubMedCrossRef Tepper OM, Small K, Rudolph L et al (2006) Virtual 3-dimensional modeling as a valuable adjunct to aesthetic and reconstructive breast surgery. Am J Surg 192:548–551PubMedCrossRef
4.
Zurück zum Zitat Kovacs L, Eder M, Hollweck R et al (2006) New aspects of breast volume measurement using 3-dimensional surface imaging. Ann Plast Surg 57:602–610PubMedCrossRef Kovacs L, Eder M, Hollweck R et al (2006) New aspects of breast volume measurement using 3-dimensional surface imaging. Ann Plast Surg 57:602–610PubMedCrossRef
5.
Zurück zum Zitat Kovacs L, Eder M, Hollweck R et al (2007) Comparison between breast volume measurement using 3D surface imaging and classical techniques. Breast 16:137–145PubMedCrossRef Kovacs L, Eder M, Hollweck R et al (2007) Comparison between breast volume measurement using 3D surface imaging and classical techniques. Breast 16:137–145PubMedCrossRef
6.
Zurück zum Zitat Tepper OM, Karp NS, Small K et al (2008) Three-dimensional imaging provides valuable clinical data to aid in unilateral tissue expander-implant breast reconstruction. Breast J 14:543–550PubMedCrossRef Tepper OM, Karp NS, Small K et al (2008) Three-dimensional imaging provides valuable clinical data to aid in unilateral tissue expander-implant breast reconstruction. Breast J 14:543–550PubMedCrossRef
7.
Zurück zum Zitat Tepper OM, Small KH, Unger JG et al (2009) 3D analysis of breast augmentation defines operative changes and their relationship to implant dimensions. Ann Plast Surg 62:570–575PubMedCrossRef Tepper OM, Small KH, Unger JG et al (2009) 3D analysis of breast augmentation defines operative changes and their relationship to implant dimensions. Ann Plast Surg 62:570–575PubMedCrossRef
8.
Zurück zum Zitat Eder M, Waldenfels FV, Sichtermann M et al (2011) Three-dimensional evaluation of breast contour and volume changes following subpectoral augmentation mammaplasty over 6 months. J Plast Reconstr Aesthet Surg 64(9):1152–1160PubMedCrossRef Eder M, Waldenfels FV, Sichtermann M et al (2011) Three-dimensional evaluation of breast contour and volume changes following subpectoral augmentation mammaplasty over 6 months. J Plast Reconstr Aesthet Surg 64(9):1152–1160PubMedCrossRef
9.
Zurück zum Zitat Henseler H, Khambay BS, Bowman A et al (2011) Investigation into accuracy and reproducibility of a 3D breast imaging system using multiple stereo cameras. J Plast Reconstr Aesthet Surg 64:577–582PubMedCrossRef Henseler H, Khambay BS, Bowman A et al (2011) Investigation into accuracy and reproducibility of a 3D breast imaging system using multiple stereo cameras. J Plast Reconstr Aesthet Surg 64:577–582PubMedCrossRef
10.
Zurück zum Zitat Liu C, Luan J, Mu L et al (2010) The role of three-dimensional scanning technique in evaluation of breast asymmetry in breast augmentation: a 100-case study. Plast Reconstr Surg 126:2125–2132 Liu C, Luan J, Mu L et al (2010) The role of three-dimensional scanning technique in evaluation of breast asymmetry in breast augmentation: a 100-case study. Plast Reconstr Surg 126:2125–2132
11.
Zurück zum Zitat Besl PJ, McKay ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14:239–256CrossRef Besl PJ, McKay ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14:239–256CrossRef
12.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327:307–310CrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327:307–310CrossRef
13.
Zurück zum Zitat Hall-Findlay EJ (2010) The three breast dimensions: analysis and effecting change. Plast Reconstr Surg 125:1632–1642PubMedCrossRef Hall-Findlay EJ (2010) The three breast dimensions: analysis and effecting change. Plast Reconstr Surg 125:1632–1642PubMedCrossRef
14.
Zurück zum Zitat Elfadl D, Garimella V, Mahapatra TK et al (2010) Lipomodelling of the breast: a review. Breast 19:202–209PubMedCrossRef Elfadl D, Garimella V, Mahapatra TK et al (2010) Lipomodelling of the breast: a review. Breast 19:202–209PubMedCrossRef
Metadaten
Titel
Measuring Volumetric Change After Augmentation Mammaplasty Using a Three-Dimensional Scanning Technique: An Innovative Method
verfasst von
Chunjun Liu
Jie Luan
Kai Ji
Jingjing Sun
Publikationsdatum
01.10.2012
Verlag
Springer-Verlag
Erschienen in
Aesthetic Plastic Surgery / Ausgabe 5/2012
Print ISSN: 0364-216X
Elektronische ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-012-9944-8

Weitere Artikel der Ausgabe 5/2012

Aesthetic Plastic Surgery 5/2012 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.