Abstract

Computed tomography fluoroscopy (CT fluoroscopy) enables real-time image control over the entire body with high geometric accuracy and, for the most part, without significant interfering artifacts, resulting in increased target accuracy, reduced intervention times, and improved biopsy specimens [14]. Depending on the procedure being used, higher radiation doses than in conventional CT-supported interventions might occur. Because the radiologist is present in the CT room during the intervention, he is exposed to additional radiation, which is an important aspect. Initial experience with CT fluoroscopically guided interventions is from the work of Katada et al. in 1994 [5] and only relatively few reports on radiation aspects in CT fluoroscopy are found in the literature [1, 2, 611]. To date, there are no reported injuries to patients and radiologists occurring with CT fluoroscopy. The time interval since the wide use of CT fluoroscopy is too short to have data on late effects to the operator using CT fluoroscopy on a daily basis. In addition, the spectrum of CT fluoroscopically guided interventional procedures will expand and more sophisticated procedures requiring longer fluoroscopy times will be performed. Thus, effective exposure reduction is very important. The purpose of our study was to assess the radiation dose to the operator’s hand by using data from phantom measurements. In addition, we investigated the effect of a lead drape on the phantom surface adjacent to the scanning plane, the use of thin radiation protective gloves, and the use of different needle holders.
Literatur
1.
Zurück zum Zitat Paulson, EK, Sheafor, DH, Enterline, DS, et al. 2001CT-fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologistsRadiology220161167CrossRefPubMed Paulson, EK, Sheafor, DH, Enterline, DS,  et al. 2001CT-fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologistsRadiology220161167CrossRefPubMed
2.
Zurück zum Zitat Silverman, SG, Tuncali, K, Adams, DF, et al. 1999CT-fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposureRadiology212673681CrossRefPubMed Silverman, SG, Tuncali, K, Adams, DF,  et al. 1999CT-fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposureRadiology212673681CrossRefPubMed
3.
Zurück zum Zitat Irie T, Kajitani M, Yoshioka H, et al. (2000) CT fluoroscopy for lung needle biopsy: a new device or needle placement and a phantom study. J Vasc Intervent Radiol 11:359–364CrossRef Irie T, Kajitani M, Yoshioka H, et al. (2000) CT fluoroscopy for lung needle biopsy: a new device or needle placement and a phantom study. J Vasc Intervent Radiol 11:359–364CrossRef
4.
Zurück zum Zitat Mey, J, Op Beeck, B, Meysman, M, et al. 2000Real-time CT fluoroscopy: diagnostic and therapeutic applicationsEur J Radiol323240CrossRef Mey, J, Op Beeck, B, Meysman, M,  et al. 2000Real-time CT fluoroscopy: diagnostic and therapeutic applicationsEur J Radiol323240CrossRef
5.
Zurück zum Zitat Katada K, Anno H, Takeshita G, et al. (1994) Development of CT fluoroscopy using fast CT. Nippon Act Radiol 54:1172–1174 Katada K, Anno H, Takeshita G, et al. (1994) Development of CT fluoroscopy using fast CT. Nippon Act Radiol 54:1172–1174
6.
Zurück zum Zitat Kato, R, Katada, K, Anno, H, et al. 1996Radiation dosimetry at CT fluoroscopy: physician’s hand dose and development of needle holdersRadiology201576578CrossRefPubMed Kato, R, Katada, K, Anno, H,  et al. 1996Radiation dosimetry at CT fluoroscopy: physician’s hand dose and development of needle holdersRadiology201576578CrossRefPubMed
7.
Zurück zum Zitat Katada, K, Kato, R, Anno, A, et al. 1996Guidance with real-time CT fluoroscopy: early clinical experienceRadiology200851856CrossRefPubMed Katada, K, Kato, R, Anno, A,  et al. 1996Guidance with real-time CT fluoroscopy: early clinical experienceRadiology200851856CrossRefPubMed
8.
Zurück zum Zitat Irie T, Kajitani M, Yuji I (2001) CT fluoroscopy-guided intervention: marked reduction of scatter radiation dose to the physician’s hand by use of a lead plate and improved I-I device. SCVIR 12:1417–1421 Irie T, Kajitani M, Yuji I (2001) CT fluoroscopy-guided intervention: marked reduction of scatter radiation dose to the physician’s hand by use of a lead plate and improved I-I device. SCVIR 12:1417–1421
9.
Zurück zum Zitat Teeuwisse WM, Geleijns J, Broerse JJ, et al. (2001) Patient and staff dose during CT guided biopsy, drainage and coagulation. Br J Radiol 74:720–726CrossRefPubMed Teeuwisse WM, Geleijns J, Broerse JJ, et al. (2001) Patient and staff dose during CT guided biopsy, drainage and coagulation. Br J Radiol 74:720–726CrossRefPubMed
10.
Zurück zum Zitat Nawfel, RD, Judy, PF, Silverman, SG, et al. 2000Personnel exposure during CT fluoroscopy-guided interventional proceduresRadiology216180184CrossRefPubMed Nawfel, RD, Judy, PF, Silverman, SG,  et al. 2000Personnel exposure during CT fluoroscopy-guided interventional proceduresRadiology216180184CrossRefPubMed
11.
Zurück zum Zitat Gianfelice D, Lepanto L, Perreault P, et al. (2000) Effect of the learning on procedure times and radiation exposure for fluoroscopy-guided percutaneous biopsy procedures. J Vasc Intervent Radiol 11:1217–1221CrossRef Gianfelice D, Lepanto L, Perreault P, et al. (2000) Effect of the learning on procedure times and radiation exposure for fluoroscopy-guided percutaneous biopsy procedures. J Vasc Intervent Radiol 11:1217–1221CrossRef
12.
Zurück zum Zitat Kleinschmidt, C 2001EGS-Ray, ein Programm zur Visualisierung von Monte-Carlo-Rechnungen in der StrahlenphysikZ Med Phys11119123CrossRefPubMed Kleinschmidt, C 2001EGS-Ray, ein Programm zur Visualisierung von Monte-Carlo-Rechnungen in der StrahlenphysikZ Med Phys11119123CrossRefPubMed
13.
Zurück zum Zitat Morin, RL, Gerber, TC, McCollough, CH 2003Radiation dose in computed tomography of the heartCirculation107917922CrossRefPubMed Morin, RL, Gerber, TC, McCollough, CH 2003Radiation dose in computed tomography of the heartCirculation107917922CrossRefPubMed
14.
Zurück zum Zitat Froelich JJ, Saar B, Hoppe M, et al. (1998) Real-time CT fluoroscopy for guidance of percutaneous drainage procedures. J Vasc Intervent Radiol 9:735–740CrossRef Froelich JJ, Saar B, Hoppe M, et al. (1998) Real-time CT fluoroscopy for guidance of percutaneous drainage procedures. J Vasc Intervent Radiol 9:735–740CrossRef
15.
Zurück zum Zitat Daly B, Krebs TL, Wong-You-Cheong JJ, et al. (1999) Percutaneous abdominal and pelvic interventional procedures using CT-fluoroscopic guidance. J Vasc Intervent Radiol 173:637–644 Daly B, Krebs TL, Wong-You-Cheong JJ, et al. (1999) Percutaneous abdominal and pelvic interventional procedures using CT-fluoroscopic guidance. J Vasc Intervent Radiol 173:637–644
16.
Zurück zum Zitat Mack, MG, Straub, R, Eichler, K, et al. 2001Nadelhalter zur Reduktion der Strahlenbelastung für den Untersucher bei einer CT-gesteuerten PunktionRadiologe41927929CrossRefPubMed Mack, MG, Straub, R, Eichler, K,  et al. 2001Nadelhalter zur Reduktion der Strahlenbelastung für den Untersucher bei einer CT-gesteuerten PunktionRadiologe41927929CrossRefPubMed
Metadaten
Titel
Radiation Dose to the Radiologist’s Hand During Continuous CT Fluoroscopy-Guided Interventions
verfasst von
Beate M. Stoeckelhuber
Thorsten Leibecke
Edda Schulz
Uwe H. Melchert
Claudia U. Bergmann-Koester
Thomas Helmberger
Joerg Gellissen
Publikationsdatum
01.06.2005
Verlag
Springer US
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 5/2005
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-005-0104-2

Weitere Artikel der Ausgabe 5/2005

CardioVascular and Interventional Radiology 5/2005 Zur Ausgabe

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.