Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 1/2008

01.01.2008 | Clinical Investigation

Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation

verfasst von: Sompol Permpongkosol, Richard E. Link, Louis R. Kavoussi, Stephen B. Solomon

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 1/2008

Einloggen, um Zugang zu erhalten

Abstract

During renal cryoablation a low-attenuation area on CT develops around the cryoprobe. Knowledge of the temperature of the growing low-attenuation area can guide therapy and ensure lethal temperatures. Herein, we report thermocouple results and correlating CT images during the development of the low-attenuation “radiographic ice ball.” Five patients who underwent percutaneous CT-guided renal cryoablation were identified who had thermocouples inserted and serial intraprocedural CT images that included images with thermocouple measurements of 0° and sub-0°C. Thermocouples had been percutaneously placed just beyond the edge of the tumors either to ensure adequate cooling or to ensure safety to adjacent critical structures. Renal cryotherapy under CT guidance produced a growing low-attenuation area corresponding to the radiographic ice ball. When the thermocouple measured 0°C, CT images showed the thermocouple tip at the edge of the low-attenuation ice ball. At lower temperatures the tip was within the low-attenuation ice ball. We conclude that knowledge of the temperature at the ice ball edge during cryoablation can be used to predict the extent of tissue necrosis and thus provide an estimate of cryotherapy effectiveness during the procedure. Further work is necessary to establish a firm relationship between the thermal conditions and the zone of damage.
Literatur
1.
Zurück zum Zitat Silverman SG, Tuncali K, Morrison PR (2005) MR imaging-guided percutaneous tumor ablation (1). Acad Radiol 12(9):1100–1109PubMedCrossRef Silverman SG, Tuncali K, Morrison PR (2005) MR imaging-guided percutaneous tumor ablation (1). Acad Radiol 12(9):1100–1109PubMedCrossRef
2.
Zurück zum Zitat Dupas B, Frampas E, Leaute F, Bertrand-Vasseur A, Lerat F (2005) [Complications of fluoroscopy-, ultrasound-, and CT-guided percutaneous interventional procedures]. J Radiol 86(5; Pt 2):586–598PubMed Dupas B, Frampas E, Leaute F, Bertrand-Vasseur A, Lerat F (2005) [Complications of fluoroscopy-, ultrasound-, and CT-guided percutaneous interventional procedures]. J Radiol 86(5; Pt 2):586–598PubMed
3.
Zurück zum Zitat Santambrogio R, Bianchi P, Pasta A, Palmisano A, Montorsi M (2002) Ultrasound-guided interventional procedures of the liver during laparoscopy: technical considerations. Surg Endosc 16(2):349–354PubMedCrossRef Santambrogio R, Bianchi P, Pasta A, Palmisano A, Montorsi M (2002) Ultrasound-guided interventional procedures of the liver during laparoscopy: technical considerations. Surg Endosc 16(2):349–354PubMedCrossRef
4.
Zurück zum Zitat Hinshaw JL, Lee FT Jr (2004) Image-guided ablation of renal cell carcinoma. Magn Reson Imaging Clin N Am 12(3):429–447, viPubMedCrossRef Hinshaw JL, Lee FT Jr (2004) Image-guided ablation of renal cell carcinoma. Magn Reson Imaging Clin N Am 12(3):429–447, viPubMedCrossRef
5.
Zurück zum Zitat Popken F, Seifert JK, Engelmann R, Dutkowski P, Nassir F, Junginger T (2000) Comparison of iceball diameter and temperature distribution achieved with 3-mm accuprobe cryoprobes in porcine and human liver tissue and human colorectal liver metastases in vitro. Cryobiology 40(4):302–310PubMedCrossRef Popken F, Seifert JK, Engelmann R, Dutkowski P, Nassir F, Junginger T (2000) Comparison of iceball diameter and temperature distribution achieved with 3-mm accuprobe cryoprobes in porcine and human liver tissue and human colorectal liver metastases in vitro. Cryobiology 40(4):302–310PubMedCrossRef
6.
Zurück zum Zitat Reiser M, Drukier AK, Ultsch B, Feuerbach S (1983) The use of CT in monitoring cryosurgery. Eur J Radiol 3(2):123–128PubMed Reiser M, Drukier AK, Ultsch B, Feuerbach S (1983) The use of CT in monitoring cryosurgery. Eur J Radiol 3(2):123–128PubMed
7.
Zurück zum Zitat Rewcastle JC, Sandison GA, Hahn LJ, Saliken JC, McKinnon JG, Donnelly BJ (1998) A model for the time-dependent thermal distribution within an iceball surrounding a cryoprobe. Phys Med Biol 43(12):3519–3534PubMedCrossRef Rewcastle JC, Sandison GA, Hahn LJ, Saliken JC, McKinnon JG, Donnelly BJ (1998) A model for the time-dependent thermal distribution within an iceball surrounding a cryoprobe. Phys Med Biol 43(12):3519–3534PubMedCrossRef
8.
Zurück zum Zitat Sandison GA, Loye MP, Rewcastle JC, Hahn LJ, Saliken JC, McKinnon JG, Donnelly BJ (1998) X-Ray CT monitoring of iceball growth and thermal distribution during cryosurgery. Phys Med Biol 43(11):3309–3324PubMedCrossRef Sandison GA, Loye MP, Rewcastle JC, Hahn LJ, Saliken JC, McKinnon JG, Donnelly BJ (1998) X-Ray CT monitoring of iceball growth and thermal distribution during cryosurgery. Phys Med Biol 43(11):3309–3324PubMedCrossRef
9.
Zurück zum Zitat Gupta A, Allaf ME, Kavoussi LR, Jarrett TW, Chan DY, Su LM, Solomon SB (2006) Computerized tomography guided percutaneous renal cryoablation with the patient under conscious sedation: initial clinical experience. J Urol 175(2):447–452, discussion 452–443PubMedCrossRef Gupta A, Allaf ME, Kavoussi LR, Jarrett TW, Chan DY, Su LM, Solomon SB (2006) Computerized tomography guided percutaneous renal cryoablation with the patient under conscious sedation: initial clinical experience. J Urol 175(2):447–452, discussion 452–443PubMedCrossRef
10.
Zurück zum Zitat Chosy SG, Nakada SY, Lee FT Jr, Warner TF (1998) Monitoring renal cryosurgery: predictors of tissue necrosis in swine. J Urol 159(4):1370–1374PubMedCrossRef Chosy SG, Nakada SY, Lee FT Jr, Warner TF (1998) Monitoring renal cryosurgery: predictors of tissue necrosis in swine. J Urol 159(4):1370–1374PubMedCrossRef
11.
Zurück zum Zitat Campbell SC, Krishnamurthi V, Chow G, Hale J, Myles J, Novick AC (1998) Renal cryosurgery: experimental evaluation of treatment parameters. Urology 52(1):29–33, discussion 33–24PubMedCrossRef Campbell SC, Krishnamurthi V, Chow G, Hale J, Myles J, Novick AC (1998) Renal cryosurgery: experimental evaluation of treatment parameters. Urology 52(1):29–33, discussion 33–24PubMedCrossRef
12.
Zurück zum Zitat Goldberg SN, Grassi CJ, Cardella JF, et al. (2005) Image-guided tumor ablation: standardization of terminology and reporting criteria. Radiology 235(3):728–739PubMedCrossRef Goldberg SN, Grassi CJ, Cardella JF, et al. (2005) Image-guided tumor ablation: standardization of terminology and reporting criteria. Radiology 235(3):728–739PubMedCrossRef
13.
Zurück zum Zitat Jang TL, Wang R, Kim SC, Troe T, Pins MR, Nadler RB (2005) Histopathology of human renal tumors after laparoscopic renal cryosurgery. J Urol 173(3):720–724PubMedCrossRef Jang TL, Wang R, Kim SC, Troe T, Pins MR, Nadler RB (2005) Histopathology of human renal tumors after laparoscopic renal cryosurgery. J Urol 173(3):720–724PubMedCrossRef
14.
Zurück zum Zitat Harada J, Mogami T (2004) [Minimally invasive therapy under image guidance—emphasizing MRI-guided cryotherapy]. Rinsho Byori 52(2):145–151PubMed Harada J, Mogami T (2004) [Minimally invasive therapy under image guidance—emphasizing MRI-guided cryotherapy]. Rinsho Byori 52(2):145–151PubMed
15.
Zurück zum Zitat Gilbert JC, Rubinsky B, Wong ST, Brennan KM, Pease GR, Leung PP (1997) Temperature determination in the frozen region during cryosurgery of rabbit liver using MR image analysis. Magn Reson Imaging 15(6):657–667PubMedCrossRef Gilbert JC, Rubinsky B, Wong ST, Brennan KM, Pease GR, Leung PP (1997) Temperature determination in the frozen region during cryosurgery of rabbit liver using MR image analysis. Magn Reson Imaging 15(6):657–667PubMedCrossRef
16.
Zurück zum Zitat Ladd AP, Rescorla FJ, Baust JG, Callahan M, Davis M, Grosfeld JL (1999) Cryosurgical effects on growing vessels. Am Surg 65(7):677–682PubMed Ladd AP, Rescorla FJ, Baust JG, Callahan M, Davis M, Grosfeld JL (1999) Cryosurgical effects on growing vessels. Am Surg 65(7):677–682PubMed
Metadaten
Titel
Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation
verfasst von
Sompol Permpongkosol
Richard E. Link
Louis R. Kavoussi
Stephen B. Solomon
Publikationsdatum
01.01.2008
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 1/2008
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-007-9220-5

Weitere Artikel der Ausgabe 1/2008

CardioVascular and Interventional Radiology 1/2008 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.