Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 1/2013

01.02.2013 | Review Article/State of the Art

A Systematic Review of Protocols for the Three-Dimensional Morphologic Assessment of Abdominal Aortic Aneurysms Using Computed Tomographic Angiography

verfasst von: Tamer M. H. Ghatwary, Benjamin O. Patterson, Alan Karthikesalingam, Robert J. Hinchliffe, Ian M. Loftus, Robert Morgan, Matt M. Thompson, Peter J. E. Holt

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 1/2013

Einloggen, um Zugang zu erhalten

Abstract

The morphology of infrarenal abdominal aortic aneurysms (AAAs) directly influences the perioperative outcome and long-term durability of endovascular aneurysm repair. A variety of methods have been proposed for the characterization of AAA morphology using reconstructed three-dimensional (3D) computed tomography (CT) images. At present, there is lack of consensus as to which of these methods is most applicable to clinical practice or research. The purpose of this review was to evaluate existing protocols that used 3D CT images in the assessment of various aspects of AAA morphology. An electronic search was performed, from January 1996 to the end of October 2010, using the Embase and Medline databases. The literature review conformed to PRISMA statement standards. The literature search identified 604 articles, of which 31 studies met inclusion criteria. Only 15 of 31 studies objectively assessed reproducibility. Existing published protocols were insufficient to define a single evidence-based methodology for preoperative assessment of AAA morphology. Further development and expert consensus are required to establish a standardized and validated protocol to determine precisely how morphology relates to outcomes after endovascular aneurysm repair.
Literatur
1.
Zurück zum Zitat Prinssen M, Verhoeven EL, Buth J et al (2004) A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms. N Engl J Med 351:1607–1618PubMedCrossRef Prinssen M, Verhoeven EL, Buth J et al (2004) A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms. N Engl J Med 351:1607–1618PubMedCrossRef
2.
Zurück zum Zitat Patterson BO, Holt PJ, Hinchliffe R et al (2008) Predicting risk in elective abdominal aortic aneurysm repair: a systematic review of current evidence. Eur J Vasc Endovasc Surg 36:637–645PubMedCrossRef Patterson BO, Holt PJ, Hinchliffe R et al (2008) Predicting risk in elective abdominal aortic aneurysm repair: a systematic review of current evidence. Eur J Vasc Endovasc Surg 36:637–645PubMedCrossRef
3.
Zurück zum Zitat Patterson BO, Holt PJ, Hinchliffe R et al (2010) Existing risk prediction methods for elective abdominal aortic aneurysm repair do not predict short-term outcome following endovascular repair. J Vasc Surg 52:25–30PubMedCrossRef Patterson BO, Holt PJ, Hinchliffe R et al (2010) Existing risk prediction methods for elective abdominal aortic aneurysm repair do not predict short-term outcome following endovascular repair. J Vasc Surg 52:25–30PubMedCrossRef
4.
Zurück zum Zitat Barnes M, Boult M, Maddern G, Fitridge R (2008) A model to predict outcomes for endovascular aneurysm repair using preoperative variables. Eur J Vasc Endovasc Surg 35:571–579PubMedCrossRef Barnes M, Boult M, Maddern G, Fitridge R (2008) A model to predict outcomes for endovascular aneurysm repair using preoperative variables. Eur J Vasc Endovasc Surg 35:571–579PubMedCrossRef
5.
Zurück zum Zitat Karthikesalingam A, Holt PJ, Hinchliffe RJ et al (2010) Risk of reintervention after endovascular aortic aneurysm repair. Br J Surg 97:657–663PubMedCrossRef Karthikesalingam A, Holt PJ, Hinchliffe RJ et al (2010) Risk of reintervention after endovascular aortic aneurysm repair. Br J Surg 97:657–663PubMedCrossRef
6.
Zurück zum Zitat Boult M, Maddern G, Barnes M, Fitridge R (2007) Factors affecting survival after endovascular aneurysm repair: results from a population based audit. Eur J Vasc Endovasc Surg 34:156–162PubMedCrossRef Boult M, Maddern G, Barnes M, Fitridge R (2007) Factors affecting survival after endovascular aneurysm repair: results from a population based audit. Eur J Vasc Endovasc Surg 34:156–162PubMedCrossRef
7.
Zurück zum Zitat Parr A, Jayaratne C (2011) Buttner P JG (2010) Comparison of volume and diameter measurement in assessing small abdominal aortic aneurysm expansion examined using computed tomographic angiography. Eur J Radiol 79:42–47PubMedCrossRef Parr A, Jayaratne C (2011) Buttner P JG (2010) Comparison of volume and diameter measurement in assessing small abdominal aortic aneurysm expansion examined using computed tomographic angiography. Eur J Radiol 79:42–47PubMedCrossRef
8.
Zurück zum Zitat Parker MV, O’Donnell SD, Chang AS et al (2005) What imaging studies are necessary for abdominal aortic endograft sizing? A prospective blinded study using conventional computed tomography, aortography, and three-dimensional computed tomography. J Vasc Surg 41:199–205PubMedCrossRef Parker MV, O’Donnell SD, Chang AS et al (2005) What imaging studies are necessary for abdominal aortic endograft sizing? A prospective blinded study using conventional computed tomography, aortography, and three-dimensional computed tomography. J Vasc Surg 41:199–205PubMedCrossRef
9.
Zurück zum Zitat Beebe HG, Kritpracha B (2004) Computed tomography scanning for endograft planning: evolving toward three-dimensional, single source imaging. Semin Vasc Surg 17:126–134PubMedCrossRef Beebe HG, Kritpracha B (2004) Computed tomography scanning for endograft planning: evolving toward three-dimensional, single source imaging. Semin Vasc Surg 17:126–134PubMedCrossRef
10.
Zurück zum Zitat Cayne NS, Veith FJ, Lipsitz EC et al (2004) Variability of maximal aortic aneurysm diameter measurements on CT scan: significance and methods to minimize. J Vasc Surg 39:811–815PubMedCrossRef Cayne NS, Veith FJ, Lipsitz EC et al (2004) Variability of maximal aortic aneurysm diameter measurements on CT scan: significance and methods to minimize. J Vasc Surg 39:811–815PubMedCrossRef
11.
Zurück zum Zitat Velazquez OC, Woo EY, Carpenter JP et al (2004) Decreased use of iliac extensions and reduced graft junctions with software-assisted centerline measurements in selection of endograft components for endovascular aneurysm repair. J Vasc Surg 40:222–227PubMedCrossRef Velazquez OC, Woo EY, Carpenter JP et al (2004) Decreased use of iliac extensions and reduced graft junctions with software-assisted centerline measurements in selection of endograft components for endovascular aneurysm repair. J Vasc Surg 40:222–227PubMedCrossRef
12.
Zurück zum Zitat Chaikof EL, Blankensteijn JD, Harris PL et al (2002) Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg 35:1048–1060PubMedCrossRef Chaikof EL, Blankensteijn JD, Harris PL et al (2002) Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg 35:1048–1060PubMedCrossRef
13.
Zurück zum Zitat Chaikof EL, Fillinger MF, Matsumura JS et al (2002) Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair. J Vasc Surg 35:1061–1066PubMedCrossRef Chaikof EL, Fillinger MF, Matsumura JS et al (2002) Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair. J Vasc Surg 35:1061–1066PubMedCrossRef
14.
Zurück zum Zitat Lutz AM, Willmann JK, Pfammatter T et al (2003) Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool. J Vasc Surg 37:619–627PubMedCrossRef Lutz AM, Willmann JK, Pfammatter T et al (2003) Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool. J Vasc Surg 37:619–627PubMedCrossRef
15.
Zurück zum Zitat Atar E, Belenky A, Hadad M et al (2006) MR angiography for abdominal and thoracic aortic aneurysms: assessment before endovascular repair in patients with impaired renal function. AJR Am J Roentgenol 186:386–393PubMedCrossRef Atar E, Belenky A, Hadad M et al (2006) MR angiography for abdominal and thoracic aortic aneurysms: assessment before endovascular repair in patients with impaired renal function. AJR Am J Roentgenol 186:386–393PubMedCrossRef
16.
Zurück zum Zitat Paslawski M, Krzyzanowski K, Zlomaniec J (2004) Diagnostic value of multiplanar CT reconstructions in the assessment of abdominal aortic aneurysms. Ann Univ Mariae Curie Sklodowska Med 59:91–98PubMed Paslawski M, Krzyzanowski K, Zlomaniec J (2004) Diagnostic value of multiplanar CT reconstructions in the assessment of abdominal aortic aneurysms. Ann Univ Mariae Curie Sklodowska Med 59:91–98PubMed
17.
Zurück zum Zitat Raman KG, Missig-Carroll N, Richardson T et al (2003) Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38:645–651PubMedCrossRef Raman KG, Missig-Carroll N, Richardson T et al (2003) Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38:645–651PubMedCrossRef
18.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535PubMedCrossRef Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535PubMedCrossRef
19.
Zurück zum Zitat Liberati A, Altman DG, Tetzlaff J et al (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 339:b2700PubMedCrossRef Liberati A, Altman DG, Tetzlaff J et al (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 339:b2700PubMedCrossRef
20.
Zurück zum Zitat Wever JJ, Blankensteijn JD, Broeders IA, Eikelboom BC (1999) Length measurements of the aorta after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 18:481–486PubMedCrossRef Wever JJ, Blankensteijn JD, Broeders IA, Eikelboom BC (1999) Length measurements of the aorta after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 18:481–486PubMedCrossRef
21.
Zurück zum Zitat Wever JJ, Blankensteijn JD, Rijn JCv et al (2000) Inter- and intraobserver variability of CT measurements obtained after endovascular repair of abdominal aortic aneurysms. AJR Am J Roentgenol 175:1279–1282PubMed Wever JJ, Blankensteijn JD, Rijn JCv et al (2000) Inter- and intraobserver variability of CT measurements obtained after endovascular repair of abdominal aortic aneurysms. AJR Am J Roentgenol 175:1279–1282PubMed
22.
Zurück zum Zitat Beebe HG, Kritpracha B, Serres S et al (2000) Endograft planning without preoperative arteriography: a clinical feasibility study. J Endovasc Ther 7:8–15PubMedCrossRef Beebe HG, Kritpracha B, Serres S et al (2000) Endograft planning without preoperative arteriography: a clinical feasibility study. J Endovasc Ther 7:8–15PubMedCrossRef
23.
Zurück zum Zitat Tillich M, Bell RE, Paik DS et al (2001) Iliac arterial injuries after endovascular repair of abdominal aortic aneurysms: correlation with iliac curvature and diameter. Radiology 219:129–136PubMed Tillich M, Bell RE, Paik DS et al (2001) Iliac arterial injuries after endovascular repair of abdominal aortic aneurysms: correlation with iliac curvature and diameter. Radiology 219:129–136PubMed
24.
Zurück zum Zitat Wolf YG, Tillich M, Lee WA et al (2001) Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg 34:509–594CrossRef Wolf YG, Tillich M, Lee WA et al (2001) Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg 34:509–594CrossRef
25.
Zurück zum Zitat Wolf YG, Tillich M, Lee WA et al (2002) Changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 36:305–309PubMedCrossRef Wolf YG, Tillich M, Lee WA et al (2002) Changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 36:305–309PubMedCrossRef
26.
Zurück zum Zitat Filis KA, Arko FR, Rubin GD et al (2002) Aortoiliac angulation and the need for secondary procedures to secure stent graft fixation: which angle is important? Int Angiol 21:349–354PubMed Filis KA, Arko FR, Rubin GD et al (2002) Aortoiliac angulation and the need for secondary procedures to secure stent graft fixation: which angle is important? Int Angiol 21:349–354PubMed
27.
Zurück zum Zitat Aziz I, Lee J, Lee JT et al (2003) Accuracy of three-dimensional simulation in the sizing of aortic endoluminal devices. Ann Vasc Surg 17:129–136PubMedCrossRef Aziz I, Lee J, Lee JT et al (2003) Accuracy of three-dimensional simulation in the sizing of aortic endoluminal devices. Ann Vasc Surg 17:129–136PubMedCrossRef
28.
Zurück zum Zitat Lee JT, Aziz IN, Haukoos JS et al (2003) Volume regression of abdominal aortic aneurysms and its relation to successful endoluminal exclusion. J Vasc Surg 38:1254–1263PubMedCrossRef Lee JT, Aziz IN, Haukoos JS et al (2003) Volume regression of abdominal aortic aneurysms and its relation to successful endoluminal exclusion. J Vasc Surg 38:1254–1263PubMedCrossRef
29.
Zurück zum Zitat Wyers MC, Fillinger MF, Schermerhorn ML et al (2003) Endovascular repair of abdominal aortic aneurysm without preoperative arteriography. J Vasc Surg 38:730–738PubMedCrossRef Wyers MC, Fillinger MF, Schermerhorn ML et al (2003) Endovascular repair of abdominal aortic aneurysm without preoperative arteriography. J Vasc Surg 38:730–738PubMedCrossRef
30.
Zurück zum Zitat Kritpracha B, Beebe HG, Comerota AJ (2004) Aortic diameter is an insensitive measurement of early aneurysm expansion after endografting. J Endovasc Ther 11:184–190PubMedCrossRef Kritpracha B, Beebe HG, Comerota AJ (2004) Aortic diameter is an insensitive measurement of early aneurysm expansion after endografting. J Endovasc Ther 11:184–190PubMedCrossRef
31.
Zurück zum Zitat Fillinger M (2006) Three-dimensional analysis of enlarging aneurysms after endovascular abdominal aortic aneurysm repair in the Gore Excluder Pivotal clinical trial. J Vasc Surg 43:888–895PubMedCrossRef Fillinger M (2006) Three-dimensional analysis of enlarging aneurysms after endovascular abdominal aortic aneurysm repair in the Gore Excluder Pivotal clinical trial. J Vasc Surg 43:888–895PubMedCrossRef
32.
Zurück zum Zitat Tournoij E, Slisatkorn W, Prokop M et al (2007) Thrombus and calcium in aortic aneurysm necks: validation of a scoring system in a Dutch cohort study. Vasc Endovasc Surg 41:120–125CrossRef Tournoij E, Slisatkorn W, Prokop M et al (2007) Thrombus and calcium in aortic aneurysm necks: validation of a scoring system in a Dutch cohort study. Vasc Endovasc Surg 41:120–125CrossRef
33.
Zurück zum Zitat Diehm N, Katzen BT, Samuels S et al (2008) Sixty-four-detector CT angiography of infrarenal aortic neck length and angulation: prospective analysis of interobserver variability. J Vasc Interv Radiol 19:1283–1288PubMedCrossRef Diehm N, Katzen BT, Samuels S et al (2008) Sixty-four-detector CT angiography of infrarenal aortic neck length and angulation: prospective analysis of interobserver variability. J Vasc Interv Radiol 19:1283–1288PubMedCrossRef
34.
Zurück zum Zitat van Prehn J, van der Wal MB, Vincken K et al (2008) Intra- and interobserver variability of aortic aneurysm volume measurement with fast CTA postprocessing software. J Endovasc Ther 15:504–510PubMedCrossRef van Prehn J, van der Wal MB, Vincken K et al (2008) Intra- and interobserver variability of aortic aneurysm volume measurement with fast CTA postprocessing software. J Endovasc Ther 15:504–510PubMedCrossRef
35.
Zurück zum Zitat van Keulen JW, van Prehn J, Prokop M et al (2009) Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair. J Endovasc Ther 16:506–513PubMedCrossRef van Keulen JW, van Prehn J, Prokop M et al (2009) Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair. J Endovasc Ther 16:506–513PubMedCrossRef
36.
Zurück zum Zitat Wyss TR, Dick F, England A et al (2009) Three-dimensional imaging core laboratory of the endovascular aneurysm repair trials: validation of methodology. Eur J Vasc Endovasc Surg 38:724–731PubMedCrossRef Wyss TR, Dick F, England A et al (2009) Three-dimensional imaging core laboratory of the endovascular aneurysm repair trials: validation of methodology. Eur J Vasc Endovasc Surg 38:724–731PubMedCrossRef
37.
Zurück zum Zitat van Keulen JW, Moll FL, Tolenaar JL et al (2010) Validation of a new standardized method to measure proximal aneurysm neck angulation. J Vasc Surg 51:821–828PubMedCrossRef van Keulen JW, Moll FL, Tolenaar JL et al (2010) Validation of a new standardized method to measure proximal aneurysm neck angulation. J Vasc Surg 51:821–828PubMedCrossRef
38.
Zurück zum Zitat Diehm N, Baumgartner I, Silvestro A et al (2005) Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: assessment of inter- and intraobserver variation. Vasa 34:255–261PubMedCrossRef Diehm N, Baumgartner I, Silvestro A et al (2005) Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: assessment of inter- and intraobserver variation. Vasa 34:255–261PubMedCrossRef
39.
Zurück zum Zitat Manning BJ, Kristmundsson T, Sonesson B, Resch T (2009) Abdominal aortic aneurysm diameter: a comparison of ultrasound measurements with those from standard and three-dimensional computed tomography reconstruction. J Vasc Surg 50:263–268PubMedCrossRef Manning BJ, Kristmundsson T, Sonesson B, Resch T (2009) Abdominal aortic aneurysm diameter: a comparison of ultrasound measurements with those from standard and three-dimensional computed tomography reconstruction. J Vasc Surg 50:263–268PubMedCrossRef
40.
Zurück zum Zitat Dillavou ED, Buck DG, Muluk SC, Makaroun MS (2003) Two-dimensional versus three-dimensional CT scan for aortic measurement. J Endovasc Ther 10:531–538PubMedCrossRef Dillavou ED, Buck DG, Muluk SC, Makaroun MS (2003) Two-dimensional versus three-dimensional CT scan for aortic measurement. J Endovasc Ther 10:531–538PubMedCrossRef
41.
Zurück zum Zitat Prinssen M, Verhoeven EL, Verhagen HJ, Blankensteijn JD (2003) Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements: a blinded comparison. Eur J Vasc Endovasc Surg 26:184–187PubMedCrossRef Prinssen M, Verhoeven EL, Verhagen HJ, Blankensteijn JD (2003) Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements: a blinded comparison. Eur J Vasc Endovasc Surg 26:184–187PubMedCrossRef
42.
Zurück zum Zitat Bargellini I, Cioni R, Petruzzi P et al (2005) Endovascular repair of abdominal aortic aneurysms: analysis of aneurysm volumetric changes at mid-term follow-up. Cardiovasc Intervent Radio 28:426–433CrossRef Bargellini I, Cioni R, Petruzzi P et al (2005) Endovascular repair of abdominal aortic aneurysms: analysis of aneurysm volumetric changes at mid-term follow-up. Cardiovasc Intervent Radio 28:426–433CrossRef
43.
Zurück zum Zitat Higashiura W, Kichikawa K, Sakaguchi S et al (2009) Accuracy of centerline of flow measurement for sizing of the Zenith AAA endovascular graft and predictive factor for risk of inadequate sizing. Cardiovasc Intervent Radiol 32:441–448PubMedCrossRef Higashiura W, Kichikawa K, Sakaguchi S et al (2009) Accuracy of centerline of flow measurement for sizing of the Zenith AAA endovascular graft and predictive factor for risk of inadequate sizing. Cardiovasc Intervent Radiol 32:441–448PubMedCrossRef
44.
Zurück zum Zitat Diehm N, Herrmann P, Dinkel HP, Multidetector CT (2004) angiography versus digital subtraction angiography for aortoiliac length measurements prior to endovascular AAA repair. J Endovasc Ther 11:527–534PubMedCrossRef Diehm N, Herrmann P, Dinkel HP, Multidetector CT (2004) angiography versus digital subtraction angiography for aortoiliac length measurements prior to endovascular AAA repair. J Endovasc Ther 11:527–534PubMedCrossRef
45.
Zurück zum Zitat Whittaker DR, Dwyer J, Fillinger MF (2005) Prediction of altered endograft path during endovascular abdominal aortic aneurysm repair with the Gore Excluder. J Vasc Surg 41:575–583PubMedCrossRef Whittaker DR, Dwyer J, Fillinger MF (2005) Prediction of altered endograft path during endovascular abdominal aortic aneurysm repair with the Gore Excluder. J Vasc Surg 41:575–583PubMedCrossRef
46.
Zurück zum Zitat Kauffmann C, Tang A, Dugas A et al (2011) Clinical validation of a software for quantitative follow-up of abdominal aortic aneurysm maximal diameter and growth by CT angiography. Eur J Radiol 77:502–508PubMedCrossRef Kauffmann C, Tang A, Dugas A et al (2011) Clinical validation of a software for quantitative follow-up of abdominal aortic aneurysm maximal diameter and growth by CT angiography. Eur J Radiol 77:502–508PubMedCrossRef
47.
Zurück zum Zitat Boyle JR, Thompson MM, Vallabhaneni SR et al (2011) Pragmatic minimum reporting standards for endovascular abdominal aortic aneurysm repair. J Endovasc Ther 18:263–271PubMedCrossRef Boyle JR, Thompson MM, Vallabhaneni SR et al (2011) Pragmatic minimum reporting standards for endovascular abdominal aortic aneurysm repair. J Endovasc Ther 18:263–271PubMedCrossRef
48.
Zurück zum Zitat Lee WA. Endovascular abdominal aortic aneurysm sizing and case planning using the TeraRecon Aquarius workstation. Vasc Endovasc Surg 41:61–77 Lee WA. Endovascular abdominal aortic aneurysm sizing and case planning using the TeraRecon Aquarius workstation. Vasc Endovasc Surg 41:61–77
49.
Zurück zum Zitat Karthikesalingam A, Hinchliffe RJ, Malkawi AH et al (2010) Morphological suitability of patients with aortoiliac aneurysms for endovascular preservation of the internal iliac artery using commercially available iliac branch graft devices. J Endovasc Ther 17:163–171PubMedCrossRef Karthikesalingam A, Hinchliffe RJ, Malkawi AH et al (2010) Morphological suitability of patients with aortoiliac aneurysms for endovascular preservation of the internal iliac artery using commercially available iliac branch graft devices. J Endovasc Ther 17:163–171PubMedCrossRef
50.
Zurück zum Zitat Coenegrachts K, Rigauts H, De Letter J (2003) Prediction of aortoiliac stent graft length: comparison of a semiautomated computed tomography angiography method and calibrated aortography. J Comput Assist Tomogr 27:284–288PubMedCrossRef Coenegrachts K, Rigauts H, De Letter J (2003) Prediction of aortoiliac stent graft length: comparison of a semiautomated computed tomography angiography method and calibrated aortography. J Comput Assist Tomogr 27:284–288PubMedCrossRef
51.
Zurück zum Zitat Young N, Chi KK, Ajaka J et al (2002) Complications with outpatient angiography and interventional procedures. Cardiovasc Intervent Radiol 25:123–126PubMedCrossRef Young N, Chi KK, Ajaka J et al (2002) Complications with outpatient angiography and interventional procedures. Cardiovasc Intervent Radiol 25:123–126PubMedCrossRef
52.
Zurück zum Zitat Rubin GD, Paik DS, Johnston PC, Napel S (1998) Measurement of the aorta and its branches with helical CT. Radiology 206:823–829PubMed Rubin GD, Paik DS, Johnston PC, Napel S (1998) Measurement of the aorta and its branches with helical CT. Radiology 206:823–829PubMed
53.
Zurück zum Zitat Wever JJ, Blankensteijn JD, Th MMWP, Eikelboom BC (2000) Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 20:177–182PubMedCrossRef Wever JJ, Blankensteijn JD, Th MMWP, Eikelboom BC (2000) Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 20:177–182PubMedCrossRef
54.
Zurück zum Zitat Albertini J, Kalliafas S, Travis S et al (2000) Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 19:308–312PubMedCrossRef Albertini J, Kalliafas S, Travis S et al (2000) Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 19:308–312PubMedCrossRef
55.
Zurück zum Zitat Sternbergh WC 3rd, Carter G, York JW et al (2002) Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. J Vasc Surg 35:482–486PubMedCrossRef Sternbergh WC 3rd, Carter G, York JW et al (2002) Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. J Vasc Surg 35:482–486PubMedCrossRef
56.
Zurück zum Zitat Boult M, Babidge W, Maddern G, on behalf of the Audit Reference Group et al (2006) Predictors of success following endovascular aneurysm repair: mid-term results. Eur J Vasc Endovasc Surg 31:123–129PubMedCrossRef Boult M, Babidge W, Maddern G, on behalf of the Audit Reference Group et al (2006) Predictors of success following endovascular aneurysm repair: mid-term results. Eur J Vasc Endovasc Surg 31:123–129PubMedCrossRef
57.
Zurück zum Zitat Choke E, Munneke G, Morgan R et al (2006) Outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile neck anatomy. Cardiovasc Intervent Radiol 29:975–980PubMedCrossRef Choke E, Munneke G, Morgan R et al (2006) Outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile neck anatomy. Cardiovasc Intervent Radiol 29:975–980PubMedCrossRef
58.
Zurück zum Zitat Hobo R, Kievit J, Leurs LJ, Buth J (2007) Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: a EUROSTAR study. J Endovasc Ther 14:1–11PubMedCrossRef Hobo R, Kievit J, Leurs LJ, Buth J (2007) Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: a EUROSTAR study. J Endovasc Ther 14:1–11PubMedCrossRef
59.
Zurück zum Zitat Fulton JJ, Farber MA, Sanchez LA et al (2006) Effect of challenging neck anatomy on mid-term migration rates in AneuRx endografts. J Vasc Surg 44:932–937PubMedCrossRef Fulton JJ, Farber MA, Sanchez LA et al (2006) Effect of challenging neck anatomy on mid-term migration rates in AneuRx endografts. J Vasc Surg 44:932–937PubMedCrossRef
60.
Zurück zum Zitat Perdikides T, Georgiadis GS, Avgerinos ED et al (2009) The Aorfix stent-graft to treat infrarenal abdominal aortic aneurysms with angulated necks and/or tortuous iliac arteries: midterm results. J Endovasc Ther 16:567–576PubMedCrossRef Perdikides T, Georgiadis GS, Avgerinos ED et al (2009) The Aorfix stent-graft to treat infrarenal abdominal aortic aneurysms with angulated necks and/or tortuous iliac arteries: midterm results. J Endovasc Ther 16:567–576PubMedCrossRef
61.
Zurück zum Zitat Dillavou ED, Muluk SC, Rhee RY et al (2003) Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair? J Vasc Surg 38:657–663PubMedCrossRef Dillavou ED, Muluk SC, Rhee RY et al (2003) Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair? J Vasc Surg 38:657–663PubMedCrossRef
62.
Zurück zum Zitat Bowman JN, Silverberg D, Ellozy S et al (2010) The role of anatomic factors in predicting success of endovascular repair of thoracic aortic aneurysms. Vasc Endovasc Surg 44:101–104CrossRef Bowman JN, Silverberg D, Ellozy S et al (2010) The role of anatomic factors in predicting success of endovascular repair of thoracic aortic aneurysms. Vasc Endovasc Surg 44:101–104CrossRef
63.
Zurück zum Zitat Jayalath RW, Mangan SH, Golledge J (2005) Aortic calcification. Eur J Vasc Endovasc Surg 30:476–488PubMedCrossRef Jayalath RW, Mangan SH, Golledge J (2005) Aortic calcification. Eur J Vasc Endovasc Surg 30:476–488PubMedCrossRef
64.
Zurück zum Zitat Bowden DJ, Aitken SR, Wilkinson IB, Dixon AK (2009) Interobserver variability in the measurement of abdominal aortic calcification using unenhanced CT. Br J Radiol 82(973):69–72PubMedCrossRef Bowden DJ, Aitken SR, Wilkinson IB, Dixon AK (2009) Interobserver variability in the measurement of abdominal aortic calcification using unenhanced CT. Br J Radiol 82(973):69–72PubMedCrossRef
65.
Zurück zum Zitat Jayalath RW, Jackson P, Golledge J (2006) Quantification of abdominal aortic calcification on CT. Arterioscler Thromb Vasc Biol 26:429–430PubMedCrossRef Jayalath RW, Jackson P, Golledge J (2006) Quantification of abdominal aortic calcification on CT. Arterioscler Thromb Vasc Biol 26:429–430PubMedCrossRef
66.
Zurück zum Zitat Filis KA, Arko FR, Rubin GD, Zarins CK (2003) Three-dimensional CT evaluation for endovascular abdominal aortic aneurysm repair. Quantitative assessment of the infrarenal aortic neck. Acta Chir Belg 103:81–86PubMed Filis KA, Arko FR, Rubin GD, Zarins CK (2003) Three-dimensional CT evaluation for endovascular abdominal aortic aneurysm repair. Quantitative assessment of the infrarenal aortic neck. Acta Chir Belg 103:81–86PubMed
Metadaten
Titel
A Systematic Review of Protocols for the Three-Dimensional Morphologic Assessment of Abdominal Aortic Aneurysms Using Computed Tomographic Angiography
verfasst von
Tamer M. H. Ghatwary
Benjamin O. Patterson
Alan Karthikesalingam
Robert J. Hinchliffe
Ian M. Loftus
Robert Morgan
Matt M. Thompson
Peter J. E. Holt
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 1/2013
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-011-0296-6

Weitere Artikel der Ausgabe 1/2013

CardioVascular and Interventional Radiology 1/2013 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.